WaveSurfer® MXs-B and MSO MXs-B Oscilloscopes
200 MHz 1 GHz
WaveSurfer® MXs-B
200 MHz, 400 MHz, 600 MHz
and 1 GHz Bandwidths
Up to 10 GS/s Sample Rate
16 Mpts/Ch Memory,
32 Mpts Interleaved
Fast Processing of Long
Memory and Math
Responsive User Interface
WaveStream™ Fast
Viewing Mode
WaveScan™ – Advanced
Search and Find
LabNotebook Documentation
and Report Generation
10.4” Touch Screen Display
LXI Compliant
MSO MXs-B
All the great features of the
WaveSurfer MXs-B plus:
18 Digital Channels
Max. Digital Signal Speed
of 250 MHz
Analog and Digital Cross
Pattern Triggering
The WaveSurfer® MXs-B and MSO MXs-B oscilloscopes pack
high performance hardware, powerful waveform processing
and advanced math, measurement and debug tools into a
compact form factor with a large touch screen display and
intuitive user interface.
With up to 10 GS/s sample rate and
32 Mpts of memory WaveSurfer can
capture large amounts of data at
very high sample rates. Other
oscilloscopes offer long memory but
they bog down trying to process or
display it. WaveSurfer handles large
amounts of data quickly providing
fast processing of long memory even
when using math and measurement
functions. The software responds
immediately to the user inputs even
while processing data.
System debug often requires more
than analog channels. The MSO
MXs-B delivers 18 digital channels
which can capture digital signals of
up to 250 MHz. The MSO MXs-B
offer analog and digital cross-trig-
gering plus measurement tools to
help debug digital busses. Teledyne
LeCroy’s WaveScan search and find
tool will scan both analog and digital
channels for anamolies plus scan
multiple digital lines for a parallel
bus pattern.
Key Features
2
TOUCH SCREEN SIMPLICITY
New Surfer image
Don’t waste time searching through a complex menu
structure to find the proper setting. Configuring the Wave-
Surfer is simple thanks to the intuitive touch screen user
interface. Everything on the screen is interactive. To adjust
channel, timebase, or trigger settings, simply touch the
associated descriptor box and the appropriate menu is
opened. Measurements can be touched to adjust their
settings and cursors can be positioned precisely by touch-
ing and dragging them to the proper location. A box can be
drawn around a portion of a waveform to create a zoom of
that waveform. Even waveform offset and delay can be
adjusted simply by touching and dragging the waveform.
3
Embedded Controller Design
and Debug
Save time when working with embed-
ded controllers by adding high-perfor-
mance mixed signal capability with the
MSO MXs-B. Capture digital signals up
to 250 MHz with up to 10 Mpts/Ch
memory, 1 GS/s and 18 channels.
Quickly and easily isolate specific
serial data events with optional I2C,
SPI, UART, RS-232, USB 1.0/1.1/2.0,
USB2-HSIC, 10/100Base T ENET, Audio
(I2S, LJ, RJ, TDM), MIL-STD-1553,
ARINC 429, MIPI D-PHY, DigRF, CAN,
LIN, FlexRay™, SENT, Manchester, and
NRZ trigger and decode options.
TOUCH SCREEN SIMPLICITY
Advanced Math and Measure
Use automatic measurement param-
eters with statistics and histicons
as well as math functions to under-
stand every waveform detail.
WaveStream Fast Viewing
Mode
WaveStream provides a vibrant,
intensity graded (256 levels) display
with a fast update to closely
simulate the look and feel of an
analog oscilloscope.
ADVANCED TOOLS FOR WAVEFORM ANALYSIS
Simple Power Measurements
Measure and analyze operating
characteristics of power conversion
devices and circuits.
LabNotebook Documentation
and Report Generation Tool
Save all results and data with a
single button press and create
custom reports with LabNotebook.
WaveScan Advanced Search
and Find Tool
Quickly search waveforms for
runts, glitches or other anomalies
with WaveScan.
Sequence Mode Acquisition
Capture many fast pulses in
quick succession or events sepa-
rated by long periods of time.
4
The WaveSurfer MXs-B and MSO
MXs-B oscilloscopes makes everyday
testing simpler and easier. The intuitive
user interface and streamlined front
panel make it easy to turn on the
oscilloscope and start making measure-
ments. The interface is designed so
that all the common measurements
and functions are just one touch away.
1. Only 15 cm (6”) Deep
The most space-efficient oscilloscope for your
bench from 200 MHz to 1 GHz.
2. Local Language User Interface
Select from 10 language preferences. Add a front
panel overlay with your local language.
3. Bright 10.4” Display
You’ll never use a small display oscilloscope again.
A fantastic viewing angle makes it easy to view.
INTUITIVE USER INTERFACE TO FIND PROBLEMS FASTER
4
3
2
1
5
4. “Push” Knobs
Trigger level, delay, and offset knobs all provide
shortcuts to common actions when pushed.
5. Zoom Control Knobs
Navigate zoom or math traces with the
multiplexed horizontal knobs.
6. WaveStream Fast Viewing Mode
Provides a lively, analog-like feel similar to a phosphor
trace. Adjust “trace” intensity with the front panel
control, or toggle between WaveStream and
real-time modes.
7. Dedicated Cursor Knobs
Select type of cursor, position them on your
signal, and read values without ever opening
a menu.
8. Touch Screen with Built-in Stylus
The most time-efficient user interface is even
easier to use with a built-in stylus.
INTUITIVE USER INTERFACE TO FIND PROBLEMS FASTER
Document and Share:
Quickly save all files with LabNotebook
Create custom reports with LabNotebook
Save to internal hard drive or network drive
Print to a USB printer
Save to USB memory stick
Connect with LAN or GPIB
View data on a PC with free WaveStudio utility
5
4
5
7
8
6
6
IDENTIFY AND ISOLATE PROBLEMS FASTER
WaveScan Advanced Search
WaveScan provides powerful isolation capabilities that hard-
ware triggers can’t provide. WaveScan provides the ability
to locate unusual events in a single capture (i.e., capture and
search), or “scan” for an event in many acquisitions over a
long period of time. Select from more than 20 search modes
to find events on any analog or digital channel or search for
a pattern across multiple digital channels.
Since the scanning “modes” are not
simply copies of the hardware trig gers,
the utility and capa bility is much higher.
For instance, there is no “frequency”
trigger in any oscilloscope, yet
WaveScan allows for “frequency”
to be quickly “scanned.” This allows
the user to accumulate a data set of
unusual events that are separated by
hours or days, enabling faster debug-
ging. When used in multiple acquisi-
tions, WaveScan builds on the
traditional Teledyne LeCroy strength
of fast processing of data. A Teledyne
LeCroy X-Stream oscilloscope will
quickly scan millions of events look-
ing for unusual occurrences, and do it
much faster and more efficiently than
other oscilloscopes can.
Advanced Waveform Capture
with Sequence Mode
Use Sequence mode to store up to
5,000 triggered events as “segments”
into memory. This can be ideal when
capturing many fast pulses in quick
succession or when capturing events
separated by long time periods.
Sequence mode provides timestamps
for each acquisition and minimizes
dead-time between triggers to less
than 1 μ s. Combine Sequence mode
with advanced triggers to isolate rare
events over time and analyze afterwards.
WaveStream Fast
Viewing Mode
WaveStream provides a vibrant,
intensity graded (256 levels) display
with fast update rate to simulate the
look and feel of an analog oscilloscope.
WaveStream is helpful for seeing
jitter or identifying unusual events.
With sampling rate as high as 10 GS/s
WaveStream is an excellent runt
or glitch finder.
7
IDENTIFY AND ISOLATE PROBLEMS FASTER LABNOTEBOOK
A UniqUe Tool for DocUmenTATion AnD reporT GenerATion
The LabNotebook feature of WaveSurfer MXs-B and MSO MXs-B provides a report generation
tool to save and document all your work. Saving all displayed waveforms, relevant settings,
and screen images is all done through LabNotebook, eliminating the need to navigate multiple
menus to save all these files independently.
The touch screen and stylus
allow for easy annotation
of the screen. LabNotebook
allows you to add freehand
text and graphics in multiple
colors along with printed
text and arrows to help identify
important parts of your
waveforms and measurements.
Annotated screen captures can
be included in custom reports.
V/div
T/div
Memory Length
Sample Rate
Measurement
Math
WAVEFORM
OSCILLOSCOPE SET UP
SCREEN DUMP
PRINTER
HARD DRIVE
USB DRIVE
EMAIL
D
o
c
u
m
e
n
t
Y
o
u
r
W
o
r
k
O
n
e
-
t
o
u
c
h
F
u
n
c
t
i
o
n
a
l
i
t
y
S
a
v
e
Y
o
u
r
W
o
r
k
R
e
c
a
l
l
J
o
b
s
Easy report generation helps you
share your findings and communicate
important results.
LabNotebook adds a simple way to
report your work and save all essential
waveforms, settings, and screen images.
Quickly save all the
necessary files with
LabNotebook in a
single button press.
Recall your settings
from any report
by using the
Flashback capability.
FLASHBACK
FLASHBACK
FLASHBACK
LABNOTEBOOK
8
High-performance Mixed
Signal Capabilities
Embedded controller design and debug
involves capturing and viewing a
number of different types of signals.
These signals are typically a mix of
analog, digital, and serial data wave-
forms from a combination of analog
sensors, microcontrollers and peripheral
devices. With the ability to capture digital
signals with speeds up to 250 MHz
and long memory of 10 Mpts/Ch the
MSO MXs-B provides unmatched
mixed signal performance. The
MSO MXs-B is the ideal tool for testing
embedded systems with 8-bit micro-
controllers or slower digital signals.
With 18 digital inputs each with
250 MHz max. input frequency and
10 Mpts/Ch memory, the MSO MXs-B
is an outstanding value and provides
a complete set of tools for embedded
system testing.
Extensive Triggering
The MSO MXs-B has extensive digital
trigger capabilities. Normal oscilloscope
triggers will operate on digital inputs.
Cross-pattern triggering allows for sim-
ple or complex trigger patterns to be
setup with any combination of analog
and digital channels. Event triggering
can be configured to arm on an analog
signal and trigger on a digital pattern.
Quick Mixed Signal Setup,
Easy-to-use
Unlike a traditional Logic Analyzer, the
MSO MXs-B is easy to use. A simple
connection links the oscilloscope with
the digital inputs so users can start
viewing signals and begin debugging
quickly. In addition, all standard
oscilloscope tools are readily
accessible. Signal debug is simple,
using standard oscilloscope tools,
such as cursors, measurement
parameters, and zooming.
EMBEDDED CONTROLLER DESIGN AND DEBUG
Teledyne LeCroy’s versatile MSO MXs-B mixed signal oscilloscope combines the powerful
WaveSurfer MXs-B with the flexibility of digital inputs using the MS-250. In addition, the
many triggering and decoding options turn the MSO MXs-B into an all-in-one analog, digital,
and serial data trigger, acquisition, and debug machine.
9
View decoded protocol information on top of physical layer waveforms and trigger on
protocol specific messages.
Powerful Serial Data Triggers
The serial data trigger will quickly
isolate events on a bus eliminating
the need to set manual triggers and
hoping to catch the right information.
Trigger conditions can be entered in
binary or hexadecimal formats and
conditional trigger capabilities even
allow triggering on a range of differ-
ent events.
Intuitive, Color-Coded
Decode Overlay
Protocol decoding is shown directly
on the waveform with an intuitive,
color-coded overlay and presented in
binary, hex or ASCII. Decoding on the
MSO MXs-B is fast even with long
memory and zooming in to the
waveform shows precise byte by
byte decoding.
Table Summary and
Search/Zoom
To further simplify the debug process
all decoded data can be displayed in a
table below the waveform grid.
Selecting an entry in the table with
the touch screen will display just that
event. Additionally, built-in search
functionality will find specific de-
coded values.
SERIAL TRIGGER AND DECODE OPTIONS
Supported Serial Data
Protocols
I2C, SPI, UART
CAN, LIN, FlexRay™, SENT
Ethernet 10/100BaseT,
USB 1.0/1.1/2.0, USB 2.0-HSIC
Audio (I2S, LJ, RJ, TDM)
MIL-STD-1553, ARINC 429
MIPI D-PHY, DigRF 3G, DigRF v4
Manchester, NRZ
Debugging serial data busses can be confusing and time consuming. The serial data and
decode options for MSO MXs-B provide time saving tools for serial bus debug and validation.
10
Power Analyzer Automates Switching Device Loss Measurements
Quickly measure and analyze the operating characteristics of power conver-
sion devices and circuits with the Power Analyzer option. Critical power
switching device measurements, control loop modulation analysis, and line
power harmonic testing are all simplified with a dedicated user interface and
automatic measurements. Areas of turn-on, turn-off, and conduction loss are
all identified with color-coded waveform overlays for faster analysis.
Power Analyzer provides quick and easy setup of voltage and current inputs
and makes measurements as simple as the push of a button. Tools are pro-
vided to help reduce sources of measurement errors and the measurement
parameters provide details of single cycle or average device power losses.
Beyond the advanced power loss measurement capabilities, the Power
Analyzer modulation analysis capabilities provide insight to under-
stand control loop response to critical events
such as a power supply’s soft start perfor-
mance or step response to line and load
changes. The Line Power Analysis tool
allows simple and quick pre-compliance
testing to EN 61000-3-2.
POWER
Key Features
Automatic switching device
measurements
Color coded overlay to identify
power losses
Control loop and time domain
response analysis
Line power and harmonics tests
to IEC 61000-3-2
Total harmonic distortion table
shows frequency contribution
B-H Curve shows magnetic
device saturation
11
BROAD RANGE OF PROBING SOLUTIONS
WaveSurfer MXs-B and MSO MXs-B support a broad range of probes for a variety of applications.
ZS Series High Impedance
Active Probes
ZS2500, ZS1500, ZS1000,
ZS2500-QUADPAK,
ZS1500-QUADPAK,
ZS1000-QUADPAK
The ZS Series probes provide high impedance and an
extensive set of probe tips and ground accessories to
handle a wide range of probing scenarios. The high
1 MΩ input resistance and low 0.9 pF input capacitance
mean this probe is ideal for all frequencies. The ZS Series
probes provide full system bandwidth for all Teledyne
LeCroy oscilloscopes having bandwidths of 1 GHz
and lower.
Differential Probes
(200 MHz – 1.5 GHz)
ZD1500, ZD1000, ZD500,
ZD200
High bandwidth, excellent common-mode rejection ratio
(CMRR) and low noise make these active differential
probes ideal for applications such as automotive
development (e.g. FlexRay) and failure analysis, as well
as wireless and data communication design. The ProBus
interface allows sensitivity, offset and common-mode
range to be displayed on the oscilloscope screen.
High Voltage
Differential Probes
ADP305, ADP300, AP031
Low cost active differential probes are intended for
measuring higher voltages. The differential techniques
employed permit measurements to be taken at two
points in a circuit without reference to the ground,
allowing the oscilloscope to be safely grounded without
the use of opto-isolators or isolating transformers.
High Voltage
Passive Probes
PPE1.2KV, PPE20KV,
PPE2KV, PPE4KV, PPE5KV,
PPE6KV
The PPE Series includes five fixed-attenuation probes
covering a range from 2 kV to 20 kV, and one switchable
probe providing ÷10/÷100 attenuation for voltage inputs
up to 1.2 kV. All fixed-attenuation, standard probes
automatically rescale compatible Teledyne LeCroy
oscilloscopes for the appropriate attenuation of the probe.
Current Probes
CP031, CP030, AP015,
CP150, CP500, DCS015
Available current probes reach bandwidths of 100 MHz,
peak currents of 700 A and sensitivities of 10 mA/div. Use
multiple current probes to make measurements on three-
phase systems or a single current probe with a voltage
probe to make instantaneous power measurements.
Teledyne LeCroy current probes enable the design and
testing of switching power supplies, motor drives, electric
vehicles, and uninterruptible power supplies.
12
SPECIFICATIONS
WaveSurfer WaveSurfer WaveSurfer WaveSurfer WaveSurfer WaveSurfer
Analog Channels 24MXs-B 44MXs-B 42MXs-B 64MXs-B 62MXs-B 104MXs-B
– Vertical MSO 44MXs-B MSO 64MXs-B MSO 104MXs-B
Bandwidth (@ 50 Ω) 200 MHz 400 MHz 400 MHz 600 MHz 600 MHz 1 GHz
Rise Time 1.75 ns 875 ps 875 ps 525 ps 525 ps 350 ps
Input Channels 4 4 2 4 2 4
Vertical Resolution 8 bits
Vertical Sensitivity (V/div) 2 mV/div–10 V/div (1 MΩ); 2 mV/div–1 V/div (50 Ω)
Vertical (DC Gain) ±1.0% of full scale (typical); ±1.5% of full scale 10 mV/div (warranted)
Accuracy
BW Limit 20 MHz 20 MHz, 200 MHz
Maximum Input Voltage 50 Ω: 5 Vrms, 1 MΩ: 400 V max. (DC + Peak AC 5 kHz) 50 Ω: 5 Vrms
1 MΩ: 250 V max.
(DC + Peak AC
10 kHz)
Input Coupling AC, DC, GND (DC and GND for 50 Ω)
Input Impedance 1 MΩ || 16 pF, or 50 Ω
Analog Channels
– Acquisition
Sample Rate 2.5 GS/s 5 GS/s 5 GS/s
(Single-shot) (10 GS/s Interleaved)
Sample Rate 50 GS/s
(Repetitive)
Record Length 16 Mpts/Ch (all channels), 32 Mpts (interleaved)
Capture Time Up to 3.2 ms at full sample rate on all four channels
Acquisition Modes Real Time, Roll, RIS (Random Interleaved Sampling), WaveStream (Fast Viewing Mode), Sequence (Segmented Memory
up to 5,000 segments with 1μ
s intersegment time)
Time Base Range 200 ps/div–1000 s/div (roll mode from 500 ms/div–1000 s/div)
Time Base Accuracy 5 ppm @ 25 °C (typical) ( 10 ppm @ 5–40 °C)
Digital Channels
– Vertical
Input Channels 18 (D0–D17) 18 (D0–D17) 18 (D0–D17)
Input Impedance 100 kΩ || 5.0 pF 100 kΩ || 5.0 pF 100 kΩ || 5.0 pF
Maximum Input Voltage ±30 V non-destruct ±30 V non-destruct ±30 V non-destruct
Threshold Groupings D0–D8, D9–D17 D0–D8, D9–D17 D0–D8, D9–D17
Threshold Selections TTL, ECL, CMOS, TTL, ECL, CMOS, TTL, ECL, CMOS,
PECL, LVDS, PECL, LVDS, PECL, LVDS,
User Defined User Defined User Defined
Digital Channels
– Acquisition
Sample Rate 1 GS/s 1 GS/s 1 GS/s
Record Length 10 Mpts/Ch 10 Mpts/Ch 10 Mpts/Ch
Minimum Detectable 2 ns 2 ns 2 ns
Pulse Width
Maximum Input 250 MHz 250 MHz 250 MHz
Frequency
13
SPECIFICATIONS
WaveSurfer WaveSurfer WaveSurfer WaveSurfer WaveSurfer WaveSurfer
24MXs-B 44MXs-B 42MXs-B 64MXs-B 62MXs-B 104MXs-B
Trigger System MSO 44MXs-B MSO 64MXs-B MSO 104MXs-B
Trigger Modes Normal, Auto, Single, and Stop
Trigger Sources Any input channel, External, Ext/10, or line; slope and level unique to each source (except for line trigger)
Trigger Coupling DC, AC, HFRej, LFRej
Pre-trigger Delay 0–100% of full scale
Post-trigger Delay 0–10,000 divisions
Trigger Hold-off 1 ns to 20 s or 1 to 1,000,000,000 events
Internal Trigger ±4.1 div from center
Level Range
External Trigger Range EXT/10 ±4V; EXT ±400 mV
Trigger Types Edge, Glitch, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV–720p, 1080i, 1080p), Runt, Slew Rate, Interval
(signal or Pattern), Dropout, Qualified (State or Edge)
Probes
Standard Probes One PP009 (5 mm) per channel One PP011 (5 mm)
per channel
Probing System BNC and Teledyne LeCroy ProBus for Active voltage, current and differential probes
Measure, Zoom, and Math Tools
Measurement Up to 6 of the following parameters can be calculated at one time on any waveform: Amplitude, Area, Base (Low), Delay,
Parameters Duty, Fall Time (90%–10%), Fall Time (80%–20%), Frequency, Maximum, Mean, Minimum, Overshoot+, Overshoot-,
Period, Peak-Peak, Phase, Rise Time (10%–90%), Rise Time (20%–80%), RMS, Skew, Standard Deviation, Top (High),
Width+, Width-. Measurements can be gated.
Zooming Use front panel QuickZoom button, or use touch screen or mouse to draw a box around the zoom area.
Math Functions Functions include Sum, Difference, Product, Ratio, Absolute Value, Averaging (summed and continuous), Derivative,
Envelope, Enhanced Resolution (to 11-bits), Floor, Integral, Invert, Reciprocal, Rescale (change scale and units), Roof,
Square, Square Root and FFT (up to 1 Mpts with power spectrum output and rectangular, VonHann, and FlatTop
windows). 1 math function may be defined at a time, 2 functions may be chained together.
Display System
Display Type Color, 10.4” TFT-LCD Touch Screen
Display Resolution SVGA: 800 x 600 pixels
Connectivity
Ethernet Port 10/100/1000Base-T Ethernet interface (RJ-45 connector)
USB Ports (5) USB Ports
GPIB Port (Optional) Supports IEEE – 488.2 (Optional External Adapter)
External Monitor Port Standard 15-pin D-Type SVGA-compatible DB-15 connector
Remote Control Via Windows Automation, or via Teledyne LeCroy Remote Command Set
Network Communication VXI-11 or VICP, LXI Class C Compliant
Standard
Physical
Dimensions (HWD) 260 mm x 340 mm x 152 mm Excluding accessories and projections (10.25” x 13.4” x 6”)
Net Weight 7.26 kg. (16.0 lbs.)
14
ORDERING INFORMATION
Product Description Product Code
WaveSurfer MXs-B Oscilloscopes
200 MHz, 2.5 GS/s, 4 Ch, 16 Mpts/Ch DSO WaveSurfer 24MXs-B
with 10.4” Color Touch Screen Display.
32 Mpts Interleaved
400 MHz, 5 GS/s, 2 Ch, 16 Mpts/Ch DSO WaveSurfer 42MXs-B
with 10.4” Color Touch Screen Display.
32 Mpts Interleaved
400 MHz, 5 GS/s, 4 Ch, 16 Mpts/Ch DSO WaveSurfer 44MXs-B
with 10.4” Color Touch Screen Display.
32 Mpts Interleaved
600 MHz,5 GS/s, 2 Ch, 16 Mpts/Ch DSO WaveSurfer 62MXs-B
with 10.4” Color Touch Screen Display.
10 GS/s, 32 Mpts Interleaved
600 MHz,5 GS/s, 4 Ch, 16 Mpts/Ch DSO WaveSurfer 64MXs-B
with 10.4” Color Touch Screen Display.
10 GS/s, 32 Mpts Interleaved
1 GHz, 5 GS/s, 4 Ch, 16 Mpts/Ch DSO WaveSurfer 104MXs-B
with 10.4” Color Touch Screen Display.
10 GS/s, 32 Mpts Interleaved
MSO MXs-B Mixed Signal Oscilloscopes
400 MHz, 5 GS/s, 4+18 Ch, 16 Mpts/Ch MSO with MSO 44MXs-B
10.4” Color Touch Screen Display. 32 Mpts Interleaved
600 MHz, 5 GS/s, 4+18 Ch, 16 Mpts/Ch MSO MSO 64MXs-B
with 10.4” Color Touch Screen Display.
10 GS/s, 32 Mpts Interleaved
1 GHz, 5 GS/s, 4+18 Ch, 16 Mpts/Ch MSO MSO 104MXs-B
with 10.4” Color Touch Screen Display.
10 GS/s, 32 Mpts Interleaved
Included with Standard Configuration
(WaveSurfer MXs-B and MSO MXs-B)
÷10, 500 MHz, 10 MΩ Passive Probe (Total of 1 Per Channel),
Getting
Started Manual and Quick Reference Guide, Standard Ports: Ethernet, USB
2.0 (5), SVGA Video Out, Audio In/Out, Protective Front Cover, Anti-virus
Software (Trial Version), Standard Commercial Calibration and Performance
Certificate, 3-year Warranty
Included with MSO MXs-B
MS-250 Mixed Signal Oscilloscope Module, 18 Channel Digital Lead Set,
Teledyne LeCroy Bus and USB2.0 Cables (1.3 m), Ground Extenders
(Qty. 20), Flexible Ground Leads (Qty. 5), Carrying Case, Operator’s Manual
and Quick Reference Guide
Product Description Product Code
General Accessories
Keyboard Accessory WSXs-KYBD
Optical Mouse Accessory WSXs-MOUSE
External GPIB Accessory USB2-GPIB
Hard Carrying Case WSXs-HARDCASE
Soft Carrying Case WSXs-SOFTCASE
Rack Mount Accessory WSXs-RACK
Accessory Pouch WSXs-POUCH
Mounting Accessory
Clamp Mounting Stand WSXs-MS-CLAMP
Local Language Overlays
German Front Panel Overlay WSXs-A-FP-GERMAN
French Front Panel Overlay WSXs-A-FP-FRENCH
Italian Front Panel Overlay WSXs-A-FP-ITALIAN
Spanish Front Panel Overlay WSXs-A-FP-SPANISH
Japanese Front Panel Overlay WSXs-A-FP-JAPANESE
Korean Front Panel Overlay WSXs-A-FP-KOREAN
Chinese (Tr) Front Panel Overlay WSXs-A-FP-CHNES-TR
Chinese (Simp) Front Panel Overlay WSXs-A-FP-CHNES-SI
Russian Front Panel Overlay WSXs-A-FP-RUSSIAN
Serial Data Options
ARINC 429 Symbolic Decode Option WSXs-ARINC429bus DSymbolic
Audiobus Trigger and Decode Option WSXs-Audiobus TD
for I2S, LJ, RJ, and TDM
CAN, LIN and FlexRay Trigger and Decode Option WSXs-AUTO
CAN TD Trigger and Decode Option WSXs-CANbus TD
D-PHY Decode Option
WSXs
-DPHYbus D
DigRF 3G Decode Option WSXs-DigRF3Gbus D
DigRF v4 Decode Option WSXs-DigRFv4bus D
ENET Decode Option WSXs-ENETbus D
FlexRay Trigger and Decode Option WSXs-FlexRaybus TD
I2C, SPI and UART Trigger and Decode Option WSXs-EMB
I2C Bus Trigger and Decode Option WSXs-I2Cbus TD
LIN Trigger and Decode Option WSXs-LINbus TD
Manchester Decode Option WSXs-Manchesterbus D
MIL-STD-1553 Trigger and Decode Option WSXs-1553 TD
NRZ Decode Option WSXs-NRZbus D
SENT Decode Option WSXs-SENTbus D
SPI Bus Trigger and Decode Option WSXs-SPIbus TD
UART and RS-232 Trigger and Decode Option WSXs-UART-RS232bus TD
USB 2.0 Decode Option
WSXs
-USB2bus D
USB2-HSIC Decode Option WSXs-USB2-HSICbus D
15
ORDERING INFORMATION
Product Description Product Code
Mixed Signal Solutions
500 MHz, 18 Channels, 2 GS/s, 50 Mpts/ch Mixed
MS-500
Signal Oscilloscope Option
250 MHz,36 Ch,1 GS/s,25 Mpts/ch (500MHz,18 Ch,2 GS/s, MS-500-36
50 Mpts/ch Interleaved) Mixed Signal Option
250 MHz, 18 Channels, 1 GS/s, 10 Mpts/ch Mixed Signal MS-250
Oscilloscope Option
MSO MXs-B Accessories
Large Gripper Probe Set for 0.10 Inch (2.54 mm) PK400-1
Pin Pitch. Includes 10 Probes with Color-coded Leads
Medium Gripper Probe Set for 0.04 Inch (1.0 mm) PK400-2
Pin Pitch. Includes 10 Probes with Color-coded Leads
Small Gripper Probe Set for 0.008 Inch (0.2 mm) PK400-3
Pin Pitch. Includes 10 Probes with Color-coded Leads
18-pin 3M Interface Cable MSO-3M MSO-3M
(Mates with 3M Part Number 2520-6002)
36 Channel Mictor Connector MSO-Mictor
(Includes 1 MSO-MICTOR-SHROUD)
Product Description Product Code
Probes and Amplifiers*
Set of 4 ZS1500, 1.5 GHz, 0.9 pF, 1 M
Ω
ZS1500-QUADPAK
High Impedance Active Probe
Set of 4 ZS1000, 1 GHz, 0.9 pF, 1 M
Ω
ZS1000-QUADPAK
High Impedance Active Probe
200 MHz, 3.5 pF, 1 M
Ω
Active Differential Probe ZD200
500 MHz, 1.0 pF, 1 M
Ω
Active Differential Probe ZD500
1 GHz, 1.0 pF, 1 M
Ω
Active Differential Probe ZD1000
1.5 GHz, 1.0 pF, 1 M
Ω
Active Differential Probe ZD1500
30 A; 100 MHz Current Probe – AC/DC; 30
Arms
; 50 Apeak Pulse CP031
30 A; 50 MHz Current Probe – AC/DC;
30
Arms
; 50 Apeak Pulse
CP030
30 A; 50 MHz Current Probe
AC/DC;
30
Arms
; 50 Apeak Pulse
AP015
150 A; 10 MHz Current Probe – AC/DC; 150 Arms; 500
Apeak
Pulse CP150
500 A; 2 MHz Current Probe – AC/DC; 500 Arms; 700
Apeak
Pulse CP500
1,400 V, 100 MHz High-Voltage Differential Probe ADP305
1,400 V, 20 MHz High-Voltage Differential Probe ADP300
1 Ch, 100 MHz Differential Amplifier DA1855A
with Precision Voltage Source
* A wide variety of other passive, active, and differential probes are also available.
Consult Teledyne LeCroy for more information.
WSMXs-B-MSO-MXs-B-DS-29jul13
Customer Service
Teledyne LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event
you experience difficulties, our digital oscilloscopes are fully warranted for three years, and our probes are warranted
for one year.
This warranty includes:
No charge for return shipping
Long-term 7-year support
Upgrade to latest software at no charge
© 2011 Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice.
Product or brand names are trademarks or requested trademarks of their respective holders.
Local sales offices are located throughout the world.
Visit our website to find the most convenient location.
1-800-5-LeCroy
teledynelecroy.com
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Teledyne LeCroy:
MSO 104MXs-B MSO 44MXs-B MSO 64MXs-B WaveSurfer 104MXs-B WaveSurfer 24MXs-B WaveSurfer 42MXs-
B WaveSurfer 44MXs-B WaveSurfer 62MXs-B WaveSurfer 64MXs-B WSXS-A-FP-GERMAN WSXS-A-FP-KOREAN
WSXS-A-FP-CHNES-SI WSXS-A-FP-CHNES-TR WSXS-A-FP-FRENCH WSXS-A-FP-RUSSIAN WSXS-A-FP-
JAPANESE WSXS-A-FP-SPANISH WSXS-A-FP-ITALIAN