Note1. Rated Current = (Rated Dissipation)/(Rated Resistance)
Note2. Rated Voltage = (Rated Dissipation)
´
(Rated Resistance). (d.c. or a.c. r.m.s. Voltage)
Ambient Temperature (
°
C)
Percentage of the rated dissipation(%)
Note3. Other nominal resistances values are also available, please contact KAMAYA for further information.
Description Requirements
D
R
£±
1%
No visible damage, legible marking
D
R
£±
5% No visible damage
D
R
£±
5% No visible damage
See Ratings Table
In accordance with Clause 4.17.4.5
D
R
£±
1%
D
R
£±
1% No visible damage
D
R
£±
5%
No visible damage, legible marking
D
R
£±
5% No visible damage
No visible damage
D
R
£±
1%
Test Methods
Clause 4.7
No breakdown or flashover
R
³
1G ohm
Clause 4.13
Clause 4.23
Clause 4.25.1
Clause 4.8
Clause 4.17
Clause 4.18
Clause 4.19
Clause 4.24
Clause 4.25.3
Clause 4.32
Clause 4.33
RLC10,16 100Va.c.,60s
RLC20
~
63 500Va.c.,60s
The applied voltage shall be 2.5 times of Rated
Voltage, or equivalent current 2s.
Dry/Damp heat(12
+
12h cycle), first cycle/
Cold/Damp heat(12
+
12h cycle), remaining
cycle./ D.C.Load.
Rated current, 1.5h "ON", 0.5h "OFF", 70
°
C, 1,000h.
Measuring temperature :
+
20
°
C/
+
125
°
C/
+
20
°
C
235
°
C, 2s
After immersion into the flux, the immersion into solder
shall be carried out in Solder bath at 260
°
C for 5s.
5 cycles between
-
55
°
C and
+
125
°
C.
40
°
C, 95%R.H., 56 days, test a) of Clause 4.24.2.1
125
°
C, no-load, 1,000h.
5N, 10s
RLC10~35 Amount of bend : 3 mm
RLC50, 63 Amount of bend : 1 mm
Bend strength of the face plating
Voltage proof
Overload
Climatic sequence
Endurance at 70
°
C
Variation of resistance with temperature
Solderability
Resistance to soldering heat
Rapid change of temperature
Damp test, steady state
Endurance at the upper category temperature
Adhesion
FIXED THICK FILM CHIP RESISTORS; RECTANGULAR TYPE & LOW OHM
RLC
KAMAYA OHM
RLC16
RLC10
100m3.3
100m3.3
0.25
0.125
RLC20
50m3.3
0.33
RLC32
0.5
RLC35
0.66
RLC50
0.75
RLC63
1.0
470m3.3
200m430m
50m180m
F, G, J
F, G, J
F, G, J
500
100
55
125
!
The derated values of dissipation for temperatures in excess of
70
°
C shall be indicated by the following Curve.
100
0
55 125
70
0.27 1.58
0.19 1.11
0.31 2.56
0.38 3.16
0.44 3.63
0.47 3.87
0.55 4.47
100
0200
0250
50m
51m
56m
60m
62m
65m
68m
70m
R050
R051
R056
R060
R062
R065
R068
R070
75mR075
80mR080
" #
55/125/56
Lower Category Temperature
-
55
°
C
Upper Category Temperature
+
125
°
C
Duration of the Damp heat, Steady-State Test
56 days
470m3.3
200m430m
100m180m
F, G, J
F, G, J
F, G, J
100
0200
0250
240m430m
100m220m
0300
J
F, J
470m3.3
0200
F, G, J
1005
(0402)
1608
(0603)
2012
(0805)
3216
(1206)
3225
(1210)
5025
(2010)
6332
(2512)
Style
Rated Dissipation
at 70
°
C
W
Rated Current
Range
A
Rated
Resistance
Range
Combinations of Rated Resistance Range,Temperature
Coefficient of Resistance and Tolerance on Rated Resistance
Rated Resistance
Range Temperature Coefficient
of Resistance 10-6/
°
C
Tolerance on
Rated Resistance
Isolation
Voltage
V
Category Temperature
Range
°
C
Area of recommended operation
Size
(Inch)
Metric
Resistance Code
82m
90m
91m
100m
110m
120m
130m
150m
R082
R090
R091
R100
R110
R120
R130
R150
160mR160
180mR180
Resistance Code
200m
220m
240m
250m
270m
300m
330m
360m
R200
R220
R240
R250
R270
R300
R330
R360
390mR390
400mR400
Resistance Code
430m
470m
500m
510m
560m
600m
620m
650m
R430
R470
R500
R510
R560
R600
R620
R650
680mR680
700mR700
Resistance Code
750m
800m
820m
900m
910m
1.0
1.1
1.2
R750
R800
R820
R900
R910
1R00
1R10
1R20
1.31R30
1.51R50
Resistance Code
1.6
1.8
2.0
2.2
2.4
2.7
3.0
3.3
1R60
1R80
2R00
2R20
2R40
2R70
3R00
3R30
Resistance Code