1SS361LPH4
Document number: DS35237 Rev. 3 - 2 1 of 4
www.diodes.com August 2011
© Diodes Incorporated
1SS361LPH4
NEW PRODUCT
SURFACE MOUNT SWITCHING DIODE
Features
Fast Switching Speed
Ultra-Small Leadless Surface Mount Package (1.0 x 0.6mm)
Ultra-Low Profile Package (0.4mm)
Low Forward Voltage (Typ of 0.9V)
Fast Reverse Recovery (Typ of 2 ns)
Low Capacitance (Typ of 0.63pF)
Lead Free By Design/RoHS Compliant (Note 1)
"Green" Device (Note 2)
Mechanical Data
Case: DFN1006H4-2
Case Material: Molded Plastic, "Green" Molding Compound.
UL Flammability Classification Rating 94V-0
Moisture Sensitivity: Level 1 per J-STD-020
Terminal Connections: Cathode Bar
Terminals: Finish - NiPdAu over Copper leadframe. Solderable
per MIL-STD-202, Method 208
Weight: 0.0009 grams (approximate)
Ordering Information (Note 3)
Part Number Case Packaging
1SS361LPH4-7B DFN1006H4-2 10,000/Tape & Reel
Notes: 1. No purposefully added lead.
2. Diodes Inc.'s "Green" policy can be found on our website at http://www.diodes.com.
3. For packaging details, go to our website at http://www.diodes.com.
Marking Information
Bottom View
DFN1006H4-2
6Z = Product Type Marking Code
Bar Denotes Cathode Side
6Z
1SS361LPH4
Document number: DS35237 Rev. 3 - 2 2 of 4
www.diodes.com August 2011
© Diodes Incorporated
1SS361LPH4
NEW PRODUCT
Maximum Ratings @TA = 25°C unless otherwise specified
Characteristic Symbol Value Unit
Non-Repetitive Peak Reverse Voltage VRM 85 V
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
VRRM
VRWM
VR 80 V
RMS Reverse Voltage VR
(
RMS
)
57 V
Forward Continuous Current IFM 300 mA
Average Rectified Output Current IO 100 mA
Non-Repetitive Peak Forward Surge Current @ t = 1.0us IFSM 2.0 A
Thermal Characteristics
Characteristic Symbol Value Unit
Power Dissipation (Note 4) PD 300 mW
Thermal Resistance Junction to Ambient Air (Note 4) R
θ
JA 417 °C/W
Operating and Storage Temperature Range TJ, TSTG -55 to +150 °C
Electrical Characteristics @TA = 25°C unless otherwise specified
Characteristic Symbol Min Typ Max Unit Test Condition
Reverse Breakdown Voltage (Note 5) V
(
BR
)
R 80 V IR = 100μA
Forward Voltage VF 0.61
0.73
0.90
0.715
0.855
1.20 V IF = 1.0mA
IF = 10mA
IF = 100mA
Leakage Current (Note 5) IR 0.1
0.5 μA
μA VR = 30V
VR = 80V
Total Capacitance CT 0.63 3.0 pF
VR = 0, f = 1.0MHz
Reverse Recovery Time trr 2.0 4.0 ns
IF = IR = 10mA,
Irr = 0.1 x IR, RL = 100Ω
Notes: 4. Part mounted on FR-4 PC board with recommended pad layout, which can be found on our website at http://www.diodes.com.
5. Short duration pulse test used to minimize self-heating effect.
00 255075100125150
P
,
P
O
WE
R
DISSI
P
A
T
I
O
N (mW)
D
T , AMBIENT TEMPERAT URE (°C)
Fig. 1 Power Derating Curve, Total Package
A
50
100
150
200
250
300
350
Note 4
I , INSTANT ANEOUS FORWARD CURRENT (mA)
F
V , INSTANT ANEOUS FORWARD VOLTAGE (mV)
Fig. 2 T ypical Forward Characteristics
F
0.1
1
10
100
1000
0 200 400 600 800 1000 1200 1400 1600
1SS361LPH4
Document number: DS35237 Rev. 3 - 2 3 of 4
www.diodes.com August 2011
© Diodes Incorporated
1SS361LPH4
NEW PRODUCT
0.1
1
10
100
1000
10000
100000
0 1020304050607080
V , INSTANTANEOUS REVERSE VOLTAGE (V)
Fig. 3 Typical Reverse Characteristics
R
I , INSTANTANEOUS REVERSE CURRENT (nA)
R
V , DC REVERSE VOLTAGE (V)
Fig. 4 Total Capacitance vs. Reverse Voltage
R
C , TOTAL CAPACITANCE (pF)
T
0
0.2
0.4
0.6
0.8
1
0.1 1 10 100
f=1MHz
Package Outline Dimensions
Suggested Pad Layout
DFN1006H4-2
Dim Min Max Typ
A 0.34 0.4 0.37
A1 0 0.05 0.03
b 0.45 0.55 0.50
D 0.95 1.075 1.00
E 0.55 0.675 0.60
E 0.40
L 0.20 0.30 0.25
R 0.05 0.15 0.10
All Dimensions in mm
Dimensions Value (in mm)
Z 1.1
G 0.3
X 0.7
Y 0.4
C 0.7
L
Eb
R
e
D
A1
A
Z
X
C
G
Y
1SS361LPH4
Document number: DS35237 Rev. 3 - 2 4 of 4
www.diodes.com August 2011
© Diodes Incorporated
1SS361LPH4
NEW PRODUCT
IMPORTANT NOTICE
DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
(AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION).
Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes
without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the
application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or
trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume
all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated
website, harmless against all damages.
Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel.
Should Customers purchase or use Diodes Incorporated p roducts for any unintended or una uthorized application, Customers shall indemnify and
hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or
indirectly, any claim of personal injury or death associated with such unintended or unauthorized application.
Products described herein may be covered by one or more United States, international or foreign p atents pending. Product names and markings
noted herein may also be covered by one or more United States, international or foreign trademarks.
LIFE SUPPORT
Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express
written approval of the Chief Executive Officer of Diodes Incorporated. As used herein:
A. Life support devices or systems are devices or systems which:
1. are intended to implant into the body, or
2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the
labeling can be reasonably expected to result in significant injury to the user.
B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or to affect its safety or effectiveness.
Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their pro ducts and an y
use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related
information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its
representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems.
Copyright © 2011, Diodes Incorporated
www.diodes.com