NON/NOS, 600/250Vac Class K5 & H NON (250V) 18-600A, General Purpose Fuses Dimensions - in All Diameters 0.008 10.38" ( 0.094) 2" (0.031) 2.59" 0.56" ( 0.008) 1/8 to 30A 450 to 600A 3" (0.031) 8.63" ( 0.094) 2.06" 0.81" ( 0.008) Description: Basic protection 250V NON Class K5 and H general purpose, non-current-limiting, one-time fuses. 35 to 60A 5.88" ( 0.062) Catalog Symbol: NON-(amp) Features: -- 125Vdc (18-100A) * Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low * NON one-time fuses do not have any appreciable degree of timedelay and thus should not be specified in circuits where large transients or motor overloads occur. Use Bussmann advanced protection FUSETRONTM FRN-R or ultimate protection Low-PeakTM LPN-RK dual-element, time-delay fuses. * For general purpose circuits, size at amp rating of circuit * For motor circuits, size at 300% to 400% according to the NEC(R) motor ampacity tables 430.247 to 430.250, per 430.6(A)(1) Amps -- 8-600A 1 IR -- 50kA Vac RMS Sym. (18-60A) -- 10kA Vac RMS Sym. (65-600A) -- 50kA Vdc (18-60A) -- 10kA Vdc (65-100A) Agency Information: CE, UL Listed, Class K5 (18-60A), Std. 248-9, Class H (65-600A), Std. 248-6 (125Vdc 18-100A), UL Guide JDDZ, File E4274 Recommended Fuse Blocks CSA Certified, Class 1421-01, File 53787 (18-12A, 65-600A) For CSA Certified 15-60A, see PON Data Sheet # 4126. Catalog Numbers (amps) NON-3 NON-3210 NON-4 NON-5 NON-6 NON-614 NON-7 NON-8 NON-9 NON-10 NON-12 NON-15 NON-20 NON-25 NON-30 NON-35 NON-40 NON-45 NON-50 NON-60 Carton Quantity and Weight 0713 1.56" 110 to 200A 70 to 100A Volts -- 250Vac Amp Rating 1 8-30 35-60 65-100 110-200 225-400 450-600 7.13" ( 0.062) 1.06" Ratings: NON-18 NON-12 NON-34 NON-810 NON-1 NON-114 NON-112 NON-1610 NON-2 NON-212 225 to 400A Carton Qty. 10 10 5 1 1 1 BU-SB13738 NON-65 NON-70 NON-75 NON-80 NON-90 NON-100 NON-110 NON-125 NON-150 NON-175 NON-200 NON-225 NON-250 NON-300 NON-350 NON-400 NON-450 NON-500 NON-600 Fuse Amps 0-30 35-60 70-100 110-200 225-400 450-600 1-Pole H25030-1 H25060-1 HM25100-1CR HM25200-1CR HM25400-1CR HM25600-1CR 2-Pole H25030-2 H25060-2 HM25100-2CR HM25200-2CR HM25400-2CR HM25600-2CR 3-Pole H25030-3 H25060-3 HM25100-3CR HM25200-3CR HM25400-3CR HM25600-3CR For additional information on 250 volt fuse blocks, see Data Sheet # 1112 (H250) and product brochure # 3192 (HM Series). Fuse Reducers For Class R Fuses Equipment Fuse Clips 60A 100A 200A 200A 400A Desired Fuse (Case) Size 30A 30A 60A 60A 100A 100A 200A Catalog Numbers (Pairs) 250V NO.263 NO.213 NO.216 NO.226 NO.2621 NO.2641 NO.2642 For additional information on Class K5 & H fuse reducers, see Data Sheet # 1118. Page 1 of 4 Data Sheet # 1030 NON/NOS, 600/250Vac Class K5 & H NON (250V) 18-600A, General Purpose Fuses 600A 400A 200A 60A 100A 30A 35A 300 15A 20A Time-Current Curves - Average Melt AMP RATING 100 TIME IN SECONDS 10 1 CURRENT IN AMPS 0713 BU-SB13738 Page 2 of 4 10,000 1,000 20 0.01 100 0.1 Data Sheet # 1030 NON/NOS, 600/250Vac Class K5 & H NOS (600V), 1-600A, General Purpose Fuses Dimensions - in All Diameters 0.008 13.38" ( 0.094) 5" ( 0.031) 0.81" ( 0.008) 1 to 30A 3.13" 450 to 600A 5.5" ( 0.031) 11.63" ( 0.094) 2.59" 1.06" ( 0.008) 35 to 60A 110 to 200A Features: Volts -- 600Vac Amps -- 1-600A IR -- 50kA Vac RMS Sym. (1-60A) -- 10kA Vac RMS Sym. (70-600A) Agency Information: CE, UL Listed, Class K5 (1-60A), Std. 248-9, Class H (70-600A), Std. 248-6, UL Guide JDDZ, File E4273 CSA Certified, Class 1421-01, File 53787 NOS-9 NOS-10 NOS-12 NOS-15 NOS-20 NOS-25 NOS-30 NOS-35 NOS-40 NOS-45 NOS-50 NOS-60 NOS-70 NOS-75 NOS-80 NOS-90 NOS-100 NOS-110 NOS-125 NOS-150 NOS-175 NOS-200 NOS-225 NOS-250 NOS 600V Carton Quantity and Weight Carton Qty. 10 10 5 1 1 1 * Protect lighting, heating and other circuits not subject to temporary surges and where available short-circuit currents are relatively low * NOS one-time fuses do not have any appreciable degree of timedelay and thus should not be specified in circuits where large transients or motor overloads occur. Use Bussmann advanced protection FUSETRONTM LPS-R or ultimate protection Low-PeakTM LPS-RK dual-element, time-delay fuses. * For general purpose circuits, size at amp rating of circuit * For motor circuits, size at 300% to 400% according to the NEC(R) motor ampacity tables 430.247 to 430.250, per 430.6(A)(1) Recommended Fuse Blocks Catalog Numbers (amps) Amp Rating 1-30 35-60 70-100 110-200 225-400 450-600 1.84" 1.34" 70 to 100A Ratings: NOS-1 NOS-2 NOS-3 NOS-4 NOS-5 NOS-6 NOS-7 NOS-8 9.63" ( 0.062) 7.9" ( 0.062) Description: Basic protection 600V NOS Class K5 and H general purpose, non-current-limiting, one-time fuses. Catalog Symbol: NOS-(amp) 225 to 400A NON-300 NOS-350 NOS-400 NOS-450 NOS-500 NOS-600 Fuse Amps 0-30 35-60 70-100 110-200 225-400 450-600 1-Pole H60030-1 H60060-1 HM60100-1CR HM60200-1CR HM60400-1CR HM60600-1CR 2-Pole H60030-2 H60060-2 HM60100-2CR HM60200-2CR HM60400-2CR HM60600-2CR 3-Pole H60030-3 H60060-3 HM60100-3CR HM60200-3CR HM60400-3CR HM60600-3CR For additional information on 600 volt fuse blocks, see Data Sheet # 1112 (H) and product brochure # 3192 (HM Series). Fuse Reducers For Class R Fuses Equipment Fuse Clips 60A 100A 200A 200A 400A Desired Fuse (Case) Size 30A 30A 60A 60A 100A 100A 200A Catalog Numbers (Pairs) 250V NO.663 NO.216 NO.616 NO.626 NO.2621 NO.2641 NO.2642 For additional information on Class R fuse reducers, see Data Sheet # 1118. The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 0713 BU-SB13738 Page 3 of 4 Data Sheet # 1030 NON/NOS Class K5 & H, 600/250Vac NOS (600V), 1-600A, General Purpose Fuses 600A 400A 200A 100A 60A 30A 35A 300 15A 20A Time-Current Curves - Average Melt AMP RATING 100 TIME IN SECONDS 10 1 0.1 0.08 0.06 0.04 0.03 CURRENT IN AMPS 10,000 1,000 20 0.01 100 0.02 The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 0713 BU-SB13738 Page 4 of 4 Data Sheet # 1030