129
This data sheet contains the MIL-PRF-39006 ratings for which AVX is
a qualied approved supplier. This will be continually updated as the
qualication expands. For COTS-Plus equivalent ratings please refer to the
TWC data sheet located on the website.
This design is an axial leaded tubular case. It includes a welded tantalum
can and header assembly that provides a hermetic seal to withstand harsh
environments. The 1000 hour failure rates of 1%, 0.1% and 0.01% correspond
to “M”, “P”, and “R” respectively. For details on testing conditions please refer
to MIL-PRF-39006.
OUTLINE DIMENSIONS
CASE DIMENSIONS: millimeters (inches)
DLA
Case
Size
AVX
Case
Size
L
+0.79 (0.031)
-0.41 (0.016)
D
Basic Case
±0.41 (0.016)
D
Insulated Case
Max
E
±6.35 (0.250)
T1 A11.51 (0.453) 4.78 (0.188) 5.56 (0.219) 38.10 (1.500)
T2 B16.28 (0.641) 7.14 (0.281) 7.92 (0.312) 57.15 (2.250)
T3 D 19.46 (0.766) 9.52 (0.375) 10.31 (0.406) 57.15 (2.250)
T4 E26.97 (1.062) 9.52 (0.375) 10.31 (0.406) 57.15 (2.250)
Currently qualified M39006 ratings include T2-T4 case sizes:
M Level
Reliability Dashes
P Level
Reliability Dashes
R Level
Reliability Dashes
M39006/22 6V-100V 6V-100V 6V-100V
M39006/25 6V-100V 6V-100V 6V-100V
M39006/30 6V-100V 6V-100V 6V-100V
M39006/31 6V-100V 6V-100V 6V-100V
Terminal welded
to case (T)
Case
+ -
F 6.35 (0.250)
W 0.64 +0.05
(.025 +.002)
T 2.380 (.094)
FD
EW
LE
VOLTAGE RATINGS (Operating Temperature -55ºC to 125ºC)
Voltage (DC)
Rated Voltage: (Vr) 85ºC 68 10 15 25 30 50 60 75 100 125
Derated Voltage: (Vc) 125ºC 4 5 610 15 20 30 40 50 65 85
Surge Voltage: (Vs) 85ºC 6.9 9.2 11.5 17.3 28.8 34.5 57.5 69 86.3 115 144
TWC Series
MIL-PRF-39006 Series – Military Conventional Wet Tantalum
011918
130
RIPPLE CURRENT MULTIPLIERS vs. Frequency, temperature and applied voltage1/ 2/ 3/
HOW TO ORDER MILITARY M39006 PART NUMBER:
M39006 /22 –0081
Type / Military
Designator
Specification
Sheet
Number
Dash
Number
Not RoHS Compliant
Frequency of
Applied
Ripple Current
120Hz 800Hz 1kHz
Ambient Still Air
Temperature (ºC) ≤55 85 105 125 ≤55 85 105 125 ≤55 85 105 125
% of
85ºC
Rated
Peak
Voltage
100% 0.60 0.39 0.71 0.43 0.72 0.45
90% 0.60 0.46 0.71 0.55 _ 0.72 0.55
80% 0.60 0.52 0.35 0.71 0.62 0.42 0.72 0.62 0.42
70% 0.60 0.58 0.44 0.71 0.69 0.52 0.72 0.70 0.52
66-2/3% 0.60 0.60 0.46 0.27 0.71 0.71 0.55 0.32 0.72 0.72 0.55 0.32
Frequency of
Applied
Ripple Current
10kHz 40kHz 100kHz
Ambient Still Air
Temperature (ºC) ≤55 85 105 125 ≤55 85 105 125 ≤55 85 105 125
% of
85ºC
Rated
Peak
Voltage
100% 0.88 0.55 1.00 0.63 1.10 0.69
90% 0.88 0.67 1.00 0.77 _ 1.10 0.85
80% 0.88 0.76 0.52 1.00 0.87 0.59 1.10 0.96 0.65
70% 0.88 0.85 0.64 1.00 0.97 0.73 1.10 1.07 0.80
66-2/3% 0.88 0.88 0.68 0.40 1.00 1.00 0.77 0.45 1.10 1.10 0.85 0.50
1/ At 125ºC the rated voltage of the capacitors decreases to 66 2/3 of the 85ºC rated voltage.
2/ The peak of the applied ac ripple voltage plus the applied dc voltage must not exceed the dc voltage rating of the capacitors.
3/ The ripple current listed in the parametric tables represents a rating calculated by using a maximum internal temperature rise (ΔT) at
50°C at 40 kHz at 85°C ambient temperature, with a maximum peak rated voltage of 66.67 percent of the 85°C peak voltage rating.
011918
TWC Series
MIL-PRF-39006 Series – Military Conventional Wet Tantalum
131
M39006 /22 RATINGS AND DASH NUMBER REFERENCE
M39006/22 Dashes
Tolerance ±
(%)
Cap
(μF)
25°C
at 120Hz
DC Rated
Voltage
(V)
at
85ºC
DC Leakage (μA) DF
max
(%)
ESR
max
(Ohms) at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
Maximum Capacitance
Change (%)
AC Ripple
(mA rms)
85ºC
at
40kHz
Case
Size
M
Level
P
Level
R
Level +25ºC
+85ºC
&
+125ºC -55ºC +85ºC +125ºC
-0007 -0227 -0447 20
140 61321 1.99 40 -40 14 16 1200 T2-0008 -0228 -0448 10
-0009 -0229 -0449 5
-0010 -0230 -0450 20
270 61 6.5 45 2.21 25 -44 17.5 20 1375 T2-0011 -0231 -0451 10
-0012 -0232 -0452 5
-0013 -0233 -0453 20
330 6 2 7.9 36 1.45 20 -44 14 16 1800 T3-0014 -0234 -0454 10
-0015 -0235 -0455 5
-0016 -0236 -0456 20
560 62 13 55 1.3 25 -64 17.5 20 1900 T3-0017 -0237 -0457 10
-0018 -0238 -0458 5
-0019 -0239 -0459 20 1200 6 3 14 90 1 20 -80 25 25 2265 T4
-0020 -0240 -0460 10
-0027 -0247 -0467 20
120 8 1 2 20 2.21 50 -44 17.5 20 1220 T2-0028 -0248 -0468 10
-0029 -0249 -0469 5
-0030 -0250 -0470 20
220 8 1 7 37 2.23 30 -44 17.5 20 1370 T2-0031 -0251 -0471 10
-0032 -0252 -0472 5
-0033 -0253 -0473 20
290 8 2 634 1.56 25 -64 17.5 20 1770 T3-0034 -0254 -0474 10
-0035 -0255 -0475 5
-0036 -0256 -0476 20
430 8 2 14 46 1.42 25 -64 17.5 20 1825 T3-0037 -0257 -0477 10
-0038 -0258 -0478 5
-0039 -0259 -0479 20 850 8 4 16 60 0.94 22 -80 25 25 2330 T4
-0040 -0260 -0480 10
-0047 -0267 -0487 20
100 10 1 4 15 1.99 60 -36 14 16 1200 T2-0048 -0268 -0488 10
-0049 -0269 -0489 5
-0050 -0270 -0490 20
180 10 1 7 30 2.21 40 -36 14 16 1.365 T2-0051 -0271 -0491 10
-0052 -0272 -0492 5
-0053 -0273 -0493 20
250 10 2 10 30 1.59 30 -40 14 16 1720 T3-0054 -0274 -0494 10
-0055 -0275 -0495 5
-0056 -0276 -0496 20
390 10 2 16 44 1.5 25 -64 17.5 20 1800 T3-0057 -0277 -0497 10
-0058 -0278 -0498 5
-0059 -0279 -0499 20 750 10 4 16 50 0.88 23 -80 25 25 2360 T4
-0060 -0280 -0500 10
-0067 -0287 -0507 20
70 15 1 4 13 2.46 75 -28 14 16 1150 T2-0068 -0288 -0508 10
-0069 -0289 -0509 5
-0070 -0290 -0510 20
120 15 1 7 18 1.99 50 -28 17.5 20 1450 T2-0071 -0291 -0511 10
-0072 -0292 -0512 5
-0073 -0293 -0513 20
170 15 2 10 25 1.95 35 -32 14 16 1480 T3-0074 -0294 -0514 10
-0075 -0295 -0515 5
-0076 -0296 -0516 20
270 15 2 16 32 1.57 30 -56 17.5 20 1740 T3-0077 -0297 -0517 10
-0078 -0298 -0518 5
-0079 -0299 -0519 20 540 15 624 40 0.98 23 -80 25 25 2330 T4
-0080 -0300 -0520 10
-0087 -0307 -0527 20
50 25 1 2 11 2.92 70 -28 13 15 1130 T2-0088 -0308 -0528 10
-0089 -0309 -0529 5
-0090 -0310 -0530 20
100 25 1 10 15 1.99 50 -28 13 15 1435 T2-0091 -0311 -0531 10
-0092 -0312 -0532 5
-0093 -0313 -0533 20
120 25 2 621 2.32 38 -32 13 15 1450 T3-0094 -0314 -0534 10
-0095 -0315 -0535 5
-0096 -0316 -0536 20
180 25 2 18 26 1.92 32 -48 13 15 1525 T3-0097 -0317 -0537 10
-0098 -0318 -0538 5
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
011918
TWC Series
MIL-PRF-39006 Series – Military Conventional Wet Tantalum
132
M39006/22 Dashes
Tolerance ±
(%)
Cap
(μF)
25°C
at 120Hz
DC Rated
Voltage
(V)
at
85ºC
DC Leakage (μA) DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
Maximum Capacitance
Change (%)
AC Ripple
(mA rms)
85ºC
at
40kHz
Case
Size
M
Level
P
Level
R
Level +25ºC
+85ºC
&
+125ºC -55ºC +85ºC +125ºC
-0099 -0319 -0539 20 350 25 7 28 35 1.33 24 -70 25 25 1970 T4
-0100 -0320 -0540 10
-0107 -0327 -0547 20
40 30 1 5 10 3.32 65 -24 10.5 12 1120 T2-0108 -0328 -0548 10
-0109 -0329 -0549 5
-0110 -0330 -0550 20
68 30 1 8 13 2.54 60 -24 13 15 1285 T2-0111 -0331 -0551 10
-0112 -0332 -0552 5
-0113 -0333 -0553 20
100 30 2 12 17 2.26 40 -28 10.5 12 1450 T3-0114 -0334 -0554 10
-0115 -0335 -0555 5
-0116 -0336 -0556 20
150 30 2 18 23 2.03 35 -48 13 15 1525 T3-0117 -0337 -0557 10
-0118 -0338 -0558 5
-0119 -0339 -0559 20 300 30 8 32 31 1.37 25 -60 25 25 1950 T4
-0120 -0340 -0560 10
-0127 -0347 -0567 20
25 50 1 5 8 4.25 95 -20 10.5 12 1005 T2-0128 -0348 -0568 10
-0129 -0349 -0569 5
-0130 -0350 -0570 20
47 50 1 911 3.11 70 -28 13 15 1155 T2-0131 -0351 -0571 10
-0132 -0352 -0572 5
-0133 -0353 -0573 20
60 50 2 12 12 2.65 45 -16 10.5 12 1335 T3-0134 -0354 -0574 10
-0135 -0355 -0575 5
-0136 -0356 -0576 20
82 50 2 16 15 2.43 45 -32 13 15 1400 T3-0137 -0357 -0577 10
-0138 -0358 -0578 5
-0139 -0359 -0579 20 160 50 8 32 17 1.41 27 -50 25 25 1900 T4
-0140 -0360 -0580 10
-0147 -0367 -0587 20
20 60 1 5 7 4.64 105 -16 10.5 12 930 T2-0148 -0368 -0588 10
-0149 -0369 -0589 5
-0150 -0370 -0590 20
39 60 1910 3.4 90 -28 10.5 12 1110 T2-0151 -0371 -0591 10
-0152 -0372 -0592 5
-0153 -0373 -0593 20
50 60 2 12 10 2.65 50 -16 10.5 12 1330 T3-0154 -0374 -0594 10
-0155 -0375 -0595 5
-0156 -0376 -0596 20
68 60 2 16 13 2.54 50 -32 10.5 12 1365 T3-0157 -0377 -0597 10
-0158 -0378 -0598 5
-0159 -0379 -0599 20 140 60 8 32 16 1.52 28 -40 20 20 1850 T4
-0160 -0380 -0600 10
-0167 -0387 -0607 20
15 75 1 5 65.31 150 -16 8 9890 T2-0168 -0388 -0608 10
-0169 -0389 -0609 5
-0170 -0390 -0610 20
33 75 1 10 10 4.02 90 -24 10.5 15 1000 T2-0171 -0391 -0611 10
-0172 -0392 -0612 5
-0173 -0393 -0613 20
40 75 2 12 92.99 60 -16 10.5 12 1250 T3-0174 -0394 -0614 10
-0175 -0395 -0615 5
-0176 -0396 -0616 20
56 75 2 17 11 2.61 60 -28 10.5 15 1335 T3-0177 -0397 -0617 10
-0178 -0398 -0618 5
-0179 -0399 -0619 20 110 75 9 36 12 1.45 29 -35 20 20 1850 T4
-0180 -0400 -0620 10
-0187 -0407 -0627 20
11 100 1 4 5 6.03 200 -16 8 8 835 T2-0188 -0408 -0628 10
-0189 -0409 -0629 5
-0190 -0410 -0630 20
22 100 1 97.5 4.52 100 -16 8 8 965 T2-0191 -0411 -0631 10
-0192 -0412 -0632 5
-0193 -0413 -0633 20
30 100 2 12 7 3.1 80 -16 8 8 1240 T3-0194 -0414 -0634 10
-0195 -0415 -0635 5
-0196 -0416 -0636 20
43 100 2 17 8.5 2.62 70 -20 8 8 1335 T3-0197 -0417 -0637 10
-0198 -0418 -0638 5
-0199 -0419 -0639 20 86 100 9 36 10 1.54 30 -25 15 15 1800 T4
-0200 -0420 -0640 10
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
011918
TWC Series
MIL-PRF-39006 Series – Military Conventional Wet Tantalum
133
M39006/25 Dashes
Tolerance ±
(%)
Cap
(μF)
25°C
at
120Hz
DC Rated
Voltage
(V)
at
85ºC
DC Leakage (μA)
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
Maximum Capacitance
Change (%)
AC Ripple
(mA rms)
85ºC
at
40kHz
Case
Size
M
Level
P
Level
R
Level +25ºC
+85ºC
&
+125ºC -55ºC +85ºC +125ºC
-0003 -0091 -0179 20 820 6 3 14 155 2.51 18 -88 16 20 1500 T2
-0004 -0092 -0180 10
-0005 -0093 -0181 20 1500 65 20 172 1.52 18 -90 20 25 1900 T3
-0006 -0094 -0182 10
-0007 -0095 -0183 20 2200 6 6 24 170 1.03 13 -90 25 30 2300 T4
-0008 -0096 -0184 10
-0011 -0099 -0187 20 680 8 314 130 2.54 22 -83 16 20 1500 T2
-0012 -0100 -0188 10
-0013 -0101 -0189 20 1500 8 5 20 170 1.5 18 -90 20 25 1900 T3
-0014 -0102 -0190 10
-0015 -0103 -0191 20 1800 8 7 25 138 1.02 14 -90 25 30 2300 T4
-0016 -0104 -0192 10
-0019 -0107 -0195 20 560 10 316 106 2.51 27 -77 16 20 1450 T2
-0020 -0108 -0196 10
-0021 -0109 -0197 20 1200 10 5 20 137 1.51 18 -88 20 25 1850 T3
-0022 -0110 -0198 10
-0023 -0111 -0199 20 1500 10 7 25 114 1.01 15 -88 25 30 2300 T4
-0024 -0112 -0200 10
-0027 -0115 -0203 20 390 15 316 74 2.52 31 -66 16 20 1450 T2
-0028 -0116 -0204 10
-0029 -0117 -0205 20 820 15 624 111 1.8 22 -77 20 25 1800 T3
-0030 -0118 -0206 10
-0031 -0119 -0207 20 1000 15 8 32 92 1.22 17 -77 25 30 2300 T4
-0032 -0120 -0208 10
-0035 -0123 -0211 20 270 25 316 55 2.7 33 -62 13 16 1400 T2
-0036 -0124 -0212 10
-0037 -0125 -0213 20 560 25 7 28 76 1.8 24 -72 20 25 1750 T3
-0038 -0126 -0214 10
-0039 -0127 -0215 20 680 25 8 32 63 1.23 19 -72 25 30 2100 T4
-0040 -0128 -0216 10
-0043 -0131 -0219 20 220 30 3 16 42 2.53 36 -60 13 16 1200 T2
-0044 -0132 -0220 10
-0045 -0133 -0221 20 470 30 8 32 64 1.81 25 -65 20 25 1500 T3
-0046 -0134 -0222 10
-0047 -0135 -0223 20 560 30 9 36 55 1.3 20 -65 25 30 2000 T4
-0048 -0136 -0224 10
-0051 -0139 -0227 20 120 50 4 24 22.5 2.49 49 -42 12 15 1200 T2
-0052 -0140 -0228 10
-0053 -0141 -0229 20 270 50 8 32 37 1.82 29 -46 20 25 1450 T3
-0054 -0142 -0230 10
-0055 -0143 -0231 20 330 50 9 36 38 1.53 22 -46 25 30 1900 T4
-0056 -0144 -0232 10
-0059 -0147 -0235 20 100 60 4 20 19 2.52 54 -36 12 15 1100 T2
-0060 -0148 -0236 10
-0061 -0149 -0237 20 220 60 8 32 30 1.81 29 -40 16 20 1400 T3
-0062 -0150 -0238 10
-0063 -0151 -0239 20 270 60 9 36 27 1.33 23 -45 20 25 1850 T4
-0064 -0152 -0240 10
-0067 -0155 -0243 20 82 75 4 24 15.2 2.46 63 -30 12 15 1000 T2
-0068 -0156 -0244 10
-0069 -0157 -0245 20 180 75 9 36 24.4 2.23 30 -35 16 20 1300 T3
-0070 -0158 -0246 10
-0071 -0159 -0247 20 220 75 10 40 37 1.8 24 -40 20 25 1800 T4
-0072 -0160 -0248 10
-0075 -0163 -0251 20 39 100 5 24 10.4 3.54 80 -20 12 15 1300 T2
-0076 -0164 -0252 10
-0077 -0165 -0253 20 68 100 10 40 11.3 2.21 40 -30 14 16 1600 T3
-0078 -0166 -0254 10
-0079 -0167 -0255 20 120 100 12 48 25 2.76 30 -35 15 17 2000 T4
-0080 -0168 -0256 10
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
M39006 /25 RATINGS AND DASH NUMBER REFERENCE
071119
TWC Series
MIL-PRF-39006 Series – Military Conventional Wet Tantalum
134
M39006/30 Dashes
Tolerance ±
(%)
Cap
(μF)
25°C
at
120Hz
DC Rated
Voltage
(V)
at
85ºC
DC Leakage (μA) DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
Maximum Capacitance
Change (%)
AC Ripple
(mA rms)
85ºC
at
40kHz
Case
Size
M
Level
P
Level
R
Level +25ºC
+85ºC
&
+125ºC -55ºC +85ºC +125ºC
-0007 -0227 -0447 20
140 6 1 3 10.5 0.99 40 -40 14 16 1200 T2
-0008 -0228 -0448 10
-0009 -0229 -0449 5
-0010 -0230 -0450 20
270 61 6.5 22.5 1.11 25 -44 17.5 20 1375 T2-0011 -0231 -0451 10
-0012 -0232 -0452 5
-0013 -0233 -0453 20
330 6 2 7.9 18 0.73 20 -44 14 16 1800 T3-0014 -0234 -0454 10
-0015 -0235 -0455 5
-0016 -0236 -0456 20
560 62 13 27.5 0.65 25 -64 17.5 20 1900 T3
-0017 -0237 -0457 10
-0018 -0238 -0458 5
-0019 -0239 -0459 20 1200 6 3 14 45 0.5 20 -80 25 25 2265 T4
-0020 -0240 -0460 10
-0027 -0247 -0467 20
120 8 1 2 10 1.11 50 -44 17.5 20 1220 T2
-0028 -0248 -0468 10
-0029 -0249 -0469 5
-0030 -0250 -0470 20
220 8 1 7 18.5 1.12 30 -44 17.5 20 1370 T2-0031 -0251 -0471 10
-0032 -0252 -0472 5
-0033 -0253 -0473 20
290 8 2 617 0.78 25 -64 17.5 20 1770 T3-0034 -0254 -0474 10
-0035 -0255 -0475 5
-0036 -0256 -0476 20
430 8 2 14 23 0.71 25 -64 17.5 20 1825 T3-0037 -0257 -0477 10
-0038 -0258 -0478 5
-0039 -0259 -0479 20 850 8 4 16 30 0.47 22 -80 25 25 2330 T4
-0040 -0260 -0480 10
-0047 -0267 -0487 20
100 10 1 4 7.5 0.99 60 -36 14 16 1200 T2-0048 -0268 -0488 10
-0049 -0269 -0489 5
-0050 -0270 -0490 20
180 10 1 7 15 1.11 40 -36 14 16 1.365 T2-0051 -0271 -0491 10
-0052 -0272 -0492 5
-0053 -0273 -0493 20
250 10 2 10 15 0.8 30 -40 14 16 1720 T3-0054 -0274 -0494 10
-0055 -0275 -0495 5
-0056 -0276 -0496 20
390 10 2 16 22 0.75 25 -64 17.5 20 1800 T3-0057 -0277 -0497 10
-0058 -0278 -0498 5
-0059 -0279 -0499 20 750 10 4 16 25 0.44 23 -80 25 25 2360 T4
-0060 -0280 -0500 10
-0067 -0287 -0507 20
70 15 1 4 6.5 1.23 75 -28 14 16 1150 T2-0068 -0288 -0508 10
-0069 -0289 -0509 5
-0070 -0290 -0510 20
120 15 1 7 90.99 50 -28 17.5 20 1450 T2-0071 -0291 -0511 10
-0072 -0292 -0512 5
-0073 -0293 -0513 20
170 15 2 10 12.5 0.98 35 -32 14 16 1480 T3-0074 -0294 -0514 10
-0075 -0295 -0515 5
-0076 -0296 -0516 20
270 15 2 16 16 0.79 30 -56 17.5 20 1740 T3-0077 -0297 -0517 10
-0078 -0298 -0518 5
-0079 -0299 -0519 20 540 15 624 20 0.49 23 -80 25 25 2330 T4
-0080 -0300 -0520 10
-0087 -0307 -0527 20 50 25 1 2 5.5 1.46 70 -28 13 15 1130 T2
-0088 -0308 -0528 10
-0089 -0309 -0529 5
-0090 -0310 -0530 20
100 25 1 10 7.5 0.99 50 -28 13 15 1435 T2-0091 -0311 -0531 10
-0092 -0312 -0532 5
-0093 -0313 -0533 20
120 25 2 610.5 1.16 38 -32 13 15 1450 T3-0094 -0314 -0534 10
-0095 -0315 -0535 5
-0096 -0316 -0536 20
180 25 2 18 13 0.96 32 -48 13 15 1525 T3
-0097 -0317 -0537 10
-0098 -0318 -0538 5
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
M39006 /30 RATINGS AND DASH NUMBER REFERENCE
071119
TWC Series
MIL-PRF-39006 Series – Military Conventional Wet Tantalum
135
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
M39006/30 Dashes
Tolerance ±
(%)
Cap
(μF)
25°C
at 120Hz
DC Rated
Voltage
(V)
at
85ºC
DC Leakage (μA) DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
Maximum Capacitance
Change (%)
AC Ripple
(mA rms)
85ºC
at
40kHz
Case
Size
M
Level
P
Level
R
Level +25ºC
+85ºC
&
+125ºC -55ºC +85ºC +125ºC
-0099 -0319 -0539 20 350 25 7 28 17.5 0.67 24 -70 25 25 1970 T4
-0100 -0320 -0540 10
-0107 -0327 -0547 20
40 30 1 5 5 1.66 65 -24 10.5 12 1120 T2-0108 -0328 -0548 10
-0109 -0329 -0549 5
-0110 -0330 -0550 20
68 30 1 8 6.5 1.27 60 -24 13 15 1285 T2-0111 -0331 -0551 10
-0112 -0332 -0552 5
-0113 -0333 -0553 20
100 30 2 12 8.5 1.13 40 -28 10.5 12 1450 T3-0114 -0334 -0554 10
-0115 -0335 -0555 5
-0116 -0336 -0556 20
150 30 2 18 11.5 1.02 35 -48 13 15 1525 T3-0117 -0337 -0557 10
-0118 -0338 -0558 5
-0119 -0339 -0559 20 300 30 8 32 15.5 0.69 25 -60 25 25 1950 T4
-0120 -0340 -0560 10
-0127 -0347 -0567 20
25 50 1 5 4 2.13 95 -20 10.5 12 1005 T2-0128 -0348 -0568 10
-0129 -0349 -0569 5
-0130 -0350 -0570 20
47 50 1 95.5 1.56 70 -28 13 15 1155 T2-0131 -0351 -0571 10
-0132 -0352 -0572 5
-0133 -0353 -0573 20
60 50 2 12 61.33 45 -16 10.5 12 1335 T3-0134 -0354 -0574 10
-0135 -0355 -0575 5
-0136 -0356 -0576 20
82 50 2 16 7.5 1.22 45 -32 13 15 1400 T3-0137 -0357 -0577 10
-0138 -0358 -0578 5
-0139 -0359 -0579 20 160 50 8 32 8.5 0.71 27 -50 25 25 1900 T4
-0140 -0360 -0580 10
-0147 -0367 -0587 20
20 60 1 5 3.5 2.32 105 -16 10.5 12 930 T2-0148 -0368 -0588 10
-0149 -0369 -0589 5
-0150 -0370 -0590 20
39 60 195 1.7 90 -28 10.5 12 1110 T2-0151 -0371 -0591 10
-0152 -0372 -0592 5
-0153 -0373 -0593 20
50 60 2 12 5 1.33 50 -16 10.5 12 1330 T3-0154 -0374 -0594 10
-0155 -0375 -0595 5
-0156 -0376 -0596 20
68 60 2 16 6.5 1.27 50 -32 10.5 12 1365 T3-0157 -0377 -0597 10
-0158 -0378 -0598 5
-0159 -0379 -0599 20 140 60 8 32 8 0.76 28 -40 20 20 1850 T4
-0160 -0380 -0600 10
-0167 -0387 -0607 20
15 75 1 5 32.66 150 -16 8 9890 T2-0168 -0388 -0608 10
-0169 -0389 -0609 5
-0170 -0390 -0610 20
33 75 1 10 5 2.01 90 -24 10.5 15 1000 T2-0171 -0391 -0611 10
-0172 -0392 -0612 5
-0173 -0393 -0613 20
40 75 2 12 4.5 1.5 60 -16 10.5 12 1250 T3-0174 -0394 -0614 10
-0175 -0395 -0615 5
-0176 -0396 -0616 20
56 75 2 17 5.5 1.31 60 -28 10.5 15 1335 T3-0177 -0397 -0617 10
-0178 -0398 -0618 5
-0179 -0399 -0619 20 110 75 9 36 6 0.73 29 -35 20 20 1850 T4
-0180 -0400 -0620 10
-0187 -0407 -0627 20
11 100 1 4 2.5 3.02 200 -16 8 8 835 T2-0188 -0408 -0628 10
-0189 -0409 -0629 5
-0190 -0410 -0630 20
22 100 1 93.75 2.26 100 -16 8 8 965 T2-0191 -0411 -0631 10
-0192 -0412 -0632 5
-0193 -0413 -0633 20
30 100 2 12 3.5 1.55 80 -16 8 8 1240 T3-0194 -0414 -0634 10
-0195 -0415 -0635 5
-0196 -0416 -0636 20
43 100 2 17 4.25 1.31 70 -20 8 8 1335 T3-0197 -0417 -0637 10
-0198 -0418 -0638 5
-0199 -0419 -0639 20 86 100 9 36 5 0.77 30 -25 15 15 1800 T4
-0200 -0420 -0640 10
071119
TWC Series
MIL-PRF-39006 Series – Military Conventional Wet Tantalum
136
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
M39006 /31 RATINGS AND DASH NUMBER REFERENCE
M39006/31 Dashes
Tolerance
± (%)
Cap
(μF)
25°C
at
120Hz
DC Rated
Voltage
(V)
at
85ºC
DC Leakage (μA)
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
Impedance
max
(Ohms)
-55ºC at
120Hz
Maximum Capacitance
Change (%)
AC Ripple
(mA rms)
85ºC
at
40kHz
Case
Size
M
Level
P
Level
R
Level +25ºC
+85ºC
&
+125ºC -55ºC +85ºC +125ºC
-0003 -0091 -0179 20 820 6 3 14 77.5 1.26 18 -88 16 20 1500 T2
-0004 -0092 -0180 10
-0005 -0093 -0181 20 1500 65 20 86 0.76 18 -90 20 25 1900 T3
-0006 -0094 -0182 10
-0007 -0095 -0183 20 2200 6 6 24 85 0.52 13 -90 25 30 2300 T4
-0008 -0096 -0184 10
-0011 -0099 -0187 20 680 8 314 65 1.27 22 -83 16 20 1500 T2
-0012 -0100 -0188 10
-0013 -0101 -0189 20 1500 8 5 20 85 0.75 18 -90 20 25 1900 T3
-0014 -0102 -0190 10
-0015 -0103 -0191 20 1800 8 7 25 69 0.51 14 -90 25 30 2300 T4
-0016 -0104 -0192 10
-0019 -0107 -0195 20 560 10 316 53 1.26 27 -77 16 20 1450 T2
-0020 -0108 -0196 10
-0021 -0109 -0197 20 1200 10 5 20 68.5 0.76 18 -88 20 25 1850 T3
-0022 -0110 -0198 10
-0023 -0111 -0199 20 1500 10 7 25 57 0.51 15 -88 25 30 2300 T4
-0024 -0112 -0200 10
-0027 -0115 -0203 20 390 15 316 37 1.26 31 -66 16 20 1450 T2
-0028 -0116 -0204 10
-0029 -0117 -0205 20 820 15 624 55.5 0.9 22 -77 20 25 1800 T3
-0030 -0118 -0206 10
-0031 -0119 -0207 20 1000 15 8 32 46 0.61 17 -77 25 30 2300 T4
-0032 -0120 -0208 10
-0035 -0123 -0211 20 270 25 316 27.5 1.35 33 -62 13 16 1400 T2
-0036 -0124 -0212 10
-0037 -0125 -0213 20 560 25 7 28 38 0.9 24 -72 20 25 1750 T3
-0038 -0126 -0214 10
-0039 -0127 -0215 20 680 25 8 32 31.5 0.62 19 -72 25 30 2100 T4
-0040 -0128 -0216 10
-0043 -0131 -0219 20 220 30 3 16 21 1.27 36 -60 13 16 1200 T2
-0044 -0132 -0220 10
-0045 -0133 -0221 20 470 30 8 32 32 0.91 25 -65 20 25 1500 T3
-0046 -0134 -0222 10
-0047 -0135 -0223 20 560 30 9 36 27.5 0.65 20 -65 25 30 2000 T4
-0048 -0136 -0224 10
-0051 -0139 -0227 20 120 50 4 24 11.3 1.25 49 -42 12 15 1200 T2
-0052 -0140 -0228 10
-0053 -0141 -0229 20 270 50 8 32 18.5 0.91 29 -46 20 25 1450 T3
-0054 -0142 -0230 10
-0055 -0143 -0231 20 330 50 9 36 19 0.77 22 -46 25 30 1900 T4
-0056 -0144 -0232 10
-0059 -0147 -0235 20 100 60 4 20 9.5 1.26 54 -36 12 15 1100 T2
-0060 -0148 -0236 10
-0061 -0149 -0237 20 220 60 8 32 15 0.91 29 -40 16 20 1400 T3
-0062 -0150 -0238 10
-0063 -0151 -0239 20 270 60 9 36 13.5 0.67 23 -45 20 25 1850 T4
-0064 -0152 -0240 10
-0067 -0155 -0243 20 82 75 4 24 7.6 1.23 63 -30 12 15 1000 T2
-0068 -0156 -0244 10
-0069 -0157 -0245 20 180 75 9 36 12.2 0.9 30 -35 16 20 1300 T3
-0070 -0158 -0246 10
-0071 -0159 -0247 20 220 75 10 40 18.5 1.12 24 -40 20 25 1800 T4
-0072 -0160 -0248 10
-0075 -0163 -0251 20 39 100 5 24 5.2 1.77 80 -20 12 15 1300 T2
-0076 -0164 -0252 10
-0077 -0165 -0253 20 68 100 10 40 5.65 1.11 40 -30 14 16 1600 T3
-0078 -0166 -0254 10
-0079 -0167 -0255 20 120 100 12 48 12.5 1.38 30 -35 15 17 2000 T4
-0080 -0168 -0256 10
071119
TWC Series
MIL-PRF-39006 Series – Military Conventional Wet Tantalum