Panel Mount Solid State Relays - AC Output
H12
25-125Amp
480/600 Vac
SCR AC Switch Output
1200 Volt Blocking
High voltage relays use IC driven circuits for switching loads up to 660 VAC. All
models come with 1200 Volts blocking standard. Types CA, CD and WD are
snubberless and feature low off-state leakage. UL 508A SCCR Approved, consult
Crydom for actual ratings.
Line Load Control Control Must Surge
Voltage Current Voltage Current Release Current
Range Range Range @ 5Vdc Voltage 1-Cycle
Vrms Arms Vdc mA Vdc Apk
H12WD4825 48-660 .15-25 4-32 15 1.0 250
UL, VDE
H12WD4850 48-660 .15-50 4-32 15 1.0 625
UL, CSA, VDE
H12WD4875 48-660 .15-75 4-32 15 1.0 1000
VDE
H12WD4890 48-660 .15-90 4-32 15 1.0 1200
UL, CSA, VDE
H12WD48125 48-660 .15-125 4-32 15 1.0 1750
UL, cUL
H12D4825 48-530 .15-25 4-32 15 1.0 250
UL, cUL, VDE
H12D4850 48-530 .15-50 4-32 15 1.0 625
UL, CSA, VDE
H12D4875 48-530 .15-75 4-32 15 1.0 1000
VDE
H12D4890 48-530 .15-90 4-32 15 1.0 1200
UL, CSA, VDE
H12CD4825 48-660 .15-25 4-15 15 1.0 250
UL, CSA, VDE
H12CD4850 48-660 .15-50 4-15 15 1.0 625
UL, CSA, VDE
H12CD4890 48-660 .15-90 4-15 15 1.0 1200
UL, CSA, VDE
Line Load Control Control Must Surge
Voltage Current Voltage Current Release Current
Range Range Range
@120Vrms
Voltage 1-Cycle
Vrms Arms Vrms mA Vrms Apk
H12CA4825 48-660 .15-25 90-140 15 10.0 250
UL, CSA, VDE
H12CA4850 48-660 .15-50 90-140 15 10.0 625
UL, CSA, VDE
H12CA4890 48-660 .15-90 90-140 15 10.0 1200
UL, CSA, VDE
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
Random turn-on, phase controllable (-10 suffix)
CWD, CWA
10-125Amp
120/240/480/600 Vac
SCR AC Switch Output
Integrated IP20 Fingerproof Cover
EMC Compliant Design
The CW series offers a SCR AC switch output featuring low off-state leakage (1mA,
snubberless), zero cross or random turn-on (-10) switching and a wide operating
range (28-280Vrms) for optimum performance at 120V ac and 240Vac line voltages.
High thermal ratings with reduced power dissipation result in reduced heat sink
requirements for optimum performance. Additional features include;
integrated,
removable finger-proof cover, LED status indication and user-friendly connectors. UL 508A
SCCR Approved, consult Crydom for actual ratings.
Line Load Control Control Must Surge
Voltage Current Voltage Current Release Current
Range Range Range @ 12Vdc Voltage 1-Cycle
Vrms Arms Vdc mA Vdc Apk
CWD2410 24-280 .15-10 3-32 10 1.0 400
UL, CSA, VDE
CWD2425 24-280 .15-25 3-32 10 1.0 600
UL, CSA, VDE
CWD2450 24-280 .15-50 3-32 10 1.0 850
UL, CSA, VDE
CWD2490 24-280 .25-90 3-32 10 1.0 1350
UL, CSA, VDE
CWD24125 24-280 .25-125 3-32 10 1.0 2000
UL, CSA, VDE
CWD4810 48-660 .15-10 4-32 10 1.0 400
UL, CSA, VDE
CWD4825 48-660 .15-25 4-32 10 1.0 600
UL, CSA, VDE
CWD4850 48-660 .15-50 4-32 10 1.0 850
UL, CSA, VDE
CWD4890 48-660 .25-90 4-32 10 1.0 1350
UL, CSA, VDE
CWD48125 48-660 .25-125 4-32 10 1.0 2000
UL, cUL
Line Load Control Control Must Surge
Voltage Current Voltage Current Release Current
Range Range Range @120Vrms Voltage 1-Cycle
Vrms Arms Vrms mA Vrms Apk
CWA2410 24-280 .15-10 90-280 6.0 10.0 400
UL, CSA, VDE
CWA2425 24-280 .15-25 90-280 6.0 10.0 600
UL, CSA, VDE
CWA2450 24-280 .15-50 90-280 6.0 10.0 850
UL, CSA, VDE
CWA2490 24-280 .25-90 90-280 6.0 10.0 1350
UL, CSA, VDE
CWA24125 24-280 .25-125 90-280 6.0 10.0 2000
UL, CSA, VDE
CWA4810 48-660 .15-10 90-280 6.0 10.0 400
UL, CSA, VDE
CWA4825 48-660 .15-25 90-280 6.0 10.0 600
UL, CSA, VDE
CWA4850 48-660 .15-50 90-280 6.0 10.0 850
UL, CSA, VDE
CWA4890 48-660 .25-90 90-280 6.0 10.0 1350
UL, CSA, VDE
CWA48125 48-660 .25-125 90-280 6.0 10.0 2000
UL, cUL
Operating Temperature Range: -40˚C to 80˚C , isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
24 Vac input versions available (E suffix)
HD, HA
12-125Amp
480Vac
Zero Voltage or Random Turn-on
Ultra Low Control Current
Crydom's HD (DC control) and HA (AC control) relays incorporate the same
proven technologies as our Series 1. All models come with 1200 volts blocking as
standard and are available in either zero-cross or random turn-on and phase
controllable (-10) switching versions.
Line Load Control Control Must Surge
Voltage Current Voltage Current Release Current
Range Range Range @ 5Vdc Voltage 1-Cycle
Vrms Arms Vdc mA Vdc Apk
HD4812 48-530 .04-12 3-32 2.0 1.0 140
UL, CSA, VDE
HD4825 48-530 .04-25 3-32 2.0 1.0 250
UL, CSA, VDE
HD4850 48-530 .04-50 3-32 2.0 1.0 625
UL, CSA, VDE
HD4875 48-530 .04-75 3-32 2.0 1.0 1000
UL, CSA, VDE
HD4890 48-530 .04-90 3-32 2.0 1.0 1200
UL, CSA, VDE
HD48110 48-530 .15-110 3-32 2.0 1.0 1500
UL, cUL
HD48125 48-530 .15-125 3-32 2.0 1.0 1750
UL, cUL
Line Load Control Control Must Surge
Voltage Current Voltage Current Release Current
Range Range Range @120Vrms Voltage 1-Cycle
Vrms Arms Vrms mA Vrms Apk
HA4812 48-530 .04-12 90-280 2.0 10.0 140
UL, CSA, VDE
HA4825 48-530 .04-25 90-280 2.0 10.0 250
UL, CSA, VDE
HA4850 48-530 .04-50 90-280 2.0 10.0 625
UL, CSA, VDE
HA4875 48-530 .04-75 90-280 2.0 10.0 1000
UL, CSA, VDE
HA4890 48-530 .04-90 90-280 2.0 10.0 1200
UL, CSA, VDE
HA48110 48-530 .15-110 90-280 2.0 10.0 1500
UL, cUL
HA48125 48-530 .15-125 90-280 2.0 10.0 1750
UL, cUL
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
24 Vac input versions available (E suffix)
SMR, SMR-6
25-90Amp
120/240/480 Vac
SCR AC Switch Output
Versatile System Monitoring SSR
LED Status Indicators, Alarm Output
The SMR system monitoring SSR’s offer a wide range of built-in fault condition
alarms to the end-user. Loss of voltage, open circuit load, relay damage and loss
of DC supply are constantly monitored. LED status indicators complete the
package for early detection of equipment problems. SMR-6 models offer the user
the capability to configure the relay with either inverting or non-inverting control
and alarm. The alarm circuit can sink or source up to 100mA.
Line Load Control Control Alarm Surge
Voltage Current Voltage Current Output Current
Range Range Range @ 12Vdc Current 1-Cycle
Vrms Arms Vdc mA mA (max.) Apk
SMR2425 60-280 .04-25 8-32 6 100 250 UL, CSA, VDE
SMR2450 60-280 .04-50 8-32 6 100 625 UL, CSA, VDE
SMR2490 60-280 .04-90 8-32 6 100 1200 UL, CSA, VDE
SMR2425-6 60-280 .04-25 8-32 6 100 250 UL, CSA, VDE
SMR2450-6 60-280 .04-50 8-32 6 100 625 UL, CSA, VDE
SMR2490-6 60-280 .04-90 8-32 6 100 120 UL, CSA, VDE
SMR4825-6 96-530 .04-25 8-32 6 100 250 CSA, VDE
SMR4850-6 96-530 .04-50 8-32 6 100 625 CSA, VDE
SMR4890-6 96-530 .04-90 8-32 6 100 1200 CSA, VDE
Operating Temperature Range: -40˚C to 80˚C, Isolation Voltage: 4000 Vrms, Minimum Off-State dv/dt: 500V/μsec
Panel Mount
9
Other Crydom products and competitive part number cross-reference available at: www.crydom.com