LM224K
,
LM224KA
,
LM324
,
LM324A
,
LM324K
,
LM324KA
,
LM2902
LM124
,
LM124A
,
LM224
,
LM224A
,
LM2902V
,
LM2902K
,
LM2902KV
,
LM2902KAV
SLOS066W –SEPTEMBER 1975–REVISED MARCH 2015
www.ti.com
6.6 Electrical Characteristics for LM2902 and LM2902V
at specified free-air temperature, VCC = 5 V (unless otherwise noted) LM2902 LM2902V
PARAMETER TEST CONDITIONS(1) TA(2) UNIT
MIN TYP(3) MAX MIN TYP(3) MAX
25°C 3 7 3 7
Non-A-suffix
VCC = 5 V to MAX, devices Full range 10 10
VIO Input offset voltage VIC = VICRmin, mV
25°C 1 2
A-suffix
VO= 1.4 V devices Full range 4
ΔVIO/ΔT Input offset voltage temperature drift RS= 0 ΩFul range 7 μV/°C
25°C 2 50 2 50
IIO Input offset current VO= 1.4 V nA
Full range 300 150
ΔIIO/ΔT Input offset voltage temperature drift Ful range 10 pA/°C
25°C –20 –250 –20 –250
IIB Input bias current VO= 1.4 V nA
Full range –500 –500
0 to 0 to
25°C VCC – 1.5 VCC – 1.5
VICR Common-mode input voltage range VCC = 5 V to MAX V
0 to 0 to
Full range VCC – 2 VCC – 2
RL= 2 kΩ25°C
RL= 10 kΩ25°C VCC – 1.5 VCC – 1.5
VOH High-level output voltage V
RL= 2 kΩFull range 22 26
VCC = MAX RL≥10 kΩFull range 23 24 27
VOL Low-level output voltage RL≤10 kΩFull range 5 20 5 20 mV
VCC = 15 V, 25°C 25 100 25 100
Large-signal differential voltage
AVD VO= 1 V to 11 V, V/mV
amplification Full range 15 15
RL≥2 kΩ
CMRR Common-mode rejection ratio VIC = VICRmin 25°C 50 80 60 80 dB
Supply-voltage rejection ratio
kSVR 25°C 50 100 60 100 dB
(ΔVCC /ΔVIO)
VO1/ VO2 Crosstalk attenuation f = 1 kHz to 20 kHz 25°C 120 120 dB
VCC = 15 V, 25°C –20 –30 –60 –20 –30 –60
VID = 1 V, Source Full range –10 –10
VO= 0 mA
IOOutput current VCC = 15 V, 25°C 10 20 10 20
VID = –1 V, Sink Full range 5 5
VO= 15 V
VID = –1 V, VO= 200 mV 25°C 30 12 40 μA
IOS Short-circuit output current VCC at 5 V, VO= 0, GND at –5 V 25°C ±40 ±60 ±40 ±60 mA
VO= 2.5 V, no load Full range 0.7 1.2 0.7 1.2
ICC Supply current (four amplifiers) mA
VCC = MAX, VO= 0.5 VCC,Full range 1.4 3 1.4 3
no load
(1) All characteristics are measured under open-loop conditions, with zero common-mode input voltage, unless otherwise specified. MAX
VCC for testing purposes is 26 V for LM2902 and 32 V for LM2902V.
(2) Full range is –40°C to 125°C for LM2902.
(3) All typical values are at TA= 25°C.
6.7 Electrical Characteristics for LMx24A and LM324KA
at specified free-air temperature, VCC = 5 V (unless otherwise noted)
LM124A LM224A LM324A, LM324KA
PARAMETER TEST CONDITIONS(1) TA(2) UNIT
MIN TYP(3) MAX MIN TYP(3) MAX MIN TYP(3) MAX
VCC = 5 V to 30 V, 25°C 2 2 3 2 3
Input offset
VIO VIC = VICRmin, mV
voltage Full range 4 4 5
VO= 1.4 V
25°C 10 2 15 2 30
Input offset
IIO VO= 1.4 V nA
current Full range 30 30 75
25°C –50 –15 –80 –15 –100
Input bias
IIB VO= 1.4 V nA
current Full range –100 –100 –200
(1) All characteristics are measured under open-loop conditions, with zero common-mode input voltage, unless otherwise specified.
(2) Full range is –55°C to 125°C for LM124A, –25°C to 85°C for LM224A, and 0°C to 70°C for LM324A.
(3) All typical values are at TA= 25°C.
6Submit Documentation Feedback Copyright © 1975–2015, Texas Instruments Incorporated
Product Folder Links: LM224K LM224KA LM324 LM324A LM324K LM324KA LM2902 LM124 LM124A LM224
LM224A LM2902V LM2902K LM2902KV LM2902KAV