RAC
AC/DC Converter
www.recom-power.com REV.: 3/2019 PA-1
Features
Regulated
Converter
Wide input range 85-305VAC
Standby mode optimized (eco design Lot 6)
High efficiency over the entire load range
Operating temperature range: -40°C to +90°C
Overvoltage and overcurrent protected
EMC compliant without external components
Encapsulated module with pins or wired
Description
The RAC05-K/277 series are multipurpose 5 watt AC/DC power supplies for enhanced mains input
conditions from 90VAC up to 305VAC with an extra wide operating temperature range from -40°C to
+90°C. These modules are designed to supply worldwide applications in automation, Industry 4.0, IoT,
household and smart buildings. For worldwide use they come with international safety certifications for
industrial, domestic and ITE as well as household standards. With both PCB-mount and wired packages,
fully protected outputs, and EMC class B emissions compliance without any external components, these
are the easiest to use modular power solutions in the industry.
E224736
RAC05-__ SK/277/W
Model Numbering
Ordering Examples:
RAC05-05SK/277 5 Watt 5Vout Single Output THT version
RAC05-24SK/277 5 Watt 24Vout Single Output THT version
RAC05-05SK/277/W 5 Watt 5Vout Single Output Wired version
RAC05-12SK/277/W 5 Watt 12Vout Single Output Wired version
Single
nom. Output Power
Output Voltage
5 Watt
Single
Output
RAC05-K/277
Selection Guide
Part Input Output Output Efficiency Max. Capacitive
Number Voltage Range Voltage Current typ (1) Load
(2)
[VAC] [VDC] [mA] [%] [µF]
RAC05-3.3SK/277 85-305 3.3 1510 77 10000
RAC05-05SK/277 85-305 5 1000 80 8000
RAC05-12SK/277 85-305 12 416 83 1500
RAC05-15SK/277 85-305 15 330 83 1000
RAC05-24SK/277 85-305 24 210 84 330
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load
Wired
Notes:
Note3: add suffix „W“ for wired version
without suffix, standard THT version
ERP
compliant
LOT6
UL62368-1 certified
EN62368-1 certified
IEC/EN60335-1 certified
EN62233 certified
IEC/EN61558-1 certified
IEC/EN61558-2-16 certified
EN55032 compliant
EN55014-1(-2) compliant
CB Report
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/277
Series
www.recom-power.com REV.: 3/2019 PA-2
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Internal Input Filter Pi type
Input Voltage Range (4,5) nom. Vin = 277VAC 85VAC
120VDC
277VAC 305VAC
430VDC
Input Current
115VAC
230VAC
277VAC
150mA
100mA
75mA
Inrush Current cold start at +25°C
115VAC
230VAC
277VAC
15A
30A
35A
No Load Power Consumption 100mW
Input Frequency Range 47Hz 63Hz
ErP Lot 6 Standby Mode Conformity
(Output Load Capability) Input Power= 0.5W
1.0W
0.34W
0.70W
Minimum Load 0%
Power Factor
115VAC
230VAC
277VAC
0.60
0.45
0.40
Start-up Time 20ms
Rise Time 10ms
Hold-up Time
115VAC
230VAC
277VAC
20ms
60ms
80ms
Internal Operating Frequency 100% load at nominal Vin 130kHz
Output Ripple and Noise (6) 20MHz BW 3.3, 5Vout
others
60mVp-p
1% of Vout
Notes:
Note4: The products were submitted for safety files at AC-Input operation
Note5: Refer to „Line Derating“
Note6: Measurements are made with a 0.1µF MLCC & 10µF E-cap in parallel across output. (low ESR)
Efficiency vs. Load
RAC05-05SK/277 RAC05-12SK/277
0 10 20 30 40 50 60 70 80 90
100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
115VAC
230VAC
277VAC
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Efficiency [%]
Output Load [%]
115VAC
230VAC
277VAC
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/277
Series
www.recom-power.com REV.: 3/2019 PA-3
REGULATIONS
Parameter Condition Value
Output Accuracy ±1.0% typ.
Line Regulation low line to high line, full load
±0.5% typ.
Load Regulation (7) 10% to 100% load 1.0% typ.
Transient Response 25% load step change 4.0% max.
recovery time 500µs typ.
PROTECTIONS
Parameter Type Value
Input Fuse (8) internal T1A, slow blow
Short Circuit Protection (SCP) below 100mWhiccup, automatic restart
Over Voltage Protection (OVP) 125% - 195%, latch of mode
Over Voltage Category OVC
II
Over Current Protection (OCP) 125% - 195%, hiccup mode
Class of Equipment Class
II
Isolation Voltage (safety certified) (9)
I/P to O/P 1 minute 4.2kVAC
Isolation Resistance Isolation Voltage 500VDC 1G
W
min.
Isolation Capacitance 100pF max.
Insulation Grade reinforced
Leakage Current 0.25mA max.
continued on next page
Deviation vs. Load
(at 115VAC, 230VAC, 277VAC)
1
0.5
0
-0.5
-1
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
1
0.5
0
-0.5
-1
Deviation [%]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
RAC05-05SK/277 RAC05-12SK/277
Notes:
Note8: Refer to local safety regulations if input over-current protection is also required
Note9: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Notes:
Note7: Operation below 10% load will not harm the converter, but specifications may not be met
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/277
Series
www.recom-power.com REV.: 3/2019 PA-4
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range @ natural convection 0.1m/s
full load
3.3Vout -40°C to +70°C
5, 12Vout -40°C to +75°C
15, 24Vout -40°C to +80°C
refer to „Derating Graph“ 3.3Vout -40°C to +85°C
all others -40°C to +90°C
Maximum Case Temperature +95°C
Temperature Coefficient 0.05%/K
Operating Altitude (10) 5000m
Operating Humidity non-condensing 5% - 95% RH max.
Pollution Degree PD2
Vibration according to MIL-STD-202G 10-500Hz, 2G 10min./1cycle, period 60min. each along x,y,z axis
MTBF according to MIL-HDBK-217F, G.B. +25°C >450 x 103 hours
Design Lifetime
230VAC +25°C
+70°C
125 x 103 hours
23 x 103 hours
277VAC +25°C
+70°C
105 x 103 hours
18 x 103 hours
Peak Load Capability Pout [%]
t
1
t
2
P
p
P
nom
P
r
Time [s]
Pnom = please refer to derating graph
PP = 1.2 x Pnom
t1 30s
t2 2 x t1
Pnom = nom. output power [W]
PP = peak output power [W]
Pr = recovery power [W]
t1 = peak time [s]
t2 = recovery time [s]
Peak Load Calculation
Notes:
Note10: Recognized by UL for safe operation up to 5000m. High altitude operation may impact the performance and lifetime.
Contact RECOM tech support for advice
Practical Example:
Pr =Pnom x (t1 + t2) - PP x t1
t2
Pr =5W (30s + 60s) - (6W x 30s) = 4.5W
60s
-40 -15 10 35 60 85
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
70
110
90
75
80
3.3VDC
5, 12VDC
15, 24VDC
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
80
60
40
90
70
50
30
20
10
0
85 90 305
Line Derating
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/277
Series
www.recom-power.com REV.: 3/2019 PA-5
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Audio/Video, information and communication technology equipment - Part 1: Safety
requirements E491408-A6004-UL UL62368-1, 2nd Edition, 2014-12-01
CAN/CSA-C22.2 No. 62368-1-14, 2nd Edt., 2014-12
Audio/Video, information and communication technology equipment -
Part 1: Safety requirements (CB Scheme) E491408-A6007-CB-1
IEC62368-1:2014 2nd Edition
Audio/Video, information and communication technology equipment -
Part 1: Safety requirements (LVD) EN62368-1:2014 + A11:2017
Household and similar electrical appliances - Safety -
Part 1: General requirements LCS190308001CS
IEC60335-1:2010 + A2:2016 + C1:2016, 5th Edt.
EN60335-1:2012 + A13:2017
Measurement methods for electromagnetic fields of household appliances and similar
apparatus with regard to human exposure EN62233:2008
Safety of power transformers, power supplies, reactors and similar products for sup-
ply voltages up to 1100 V (CB Scheme)
50230493 001
IEC61558-1:2005 2nd Edition + A1:2009
Safety of power transformers, power supplies, reactors and similar products for sup-
ply voltages up to 1100 V Part 2: Particular requirements (CB Scheme) IEC61558-2-16:2009 1st Edition + A1:2013
Safety of power transformers, power supplies, reactors and similar products for sup-
ply voltages up to 1100 V EN61558-1:2005 + A1:2009
Safety of power transformers, power supplies, reactors and similar products for sup-
ply voltages up to 1100 V Part 2: Particular requirements
EN61558-2-16:2009 + A1:2013
RoHS2 RoHS-2011/65/EU + AM-2015/863
EMC Compliance Conditions Standard / Criterion
Low-voltage power supplies DC output - Part 3: Electromagnetic compatibility
EN61204-3: 2018, Class B
Electromagnetic compatibility of multimedia equipment - Emission requirements
(11)
EN55032:2015, Class B
Electromagnetic compatibility - Requirements for household appliances, electric tools
and similar apparatus - Part 1: Emission
EN55014-1:2006 + A2:2011
I
nformation technology equipment - Immunity characteristics - Limits and methods of measurement
EN55024:2010 + A1:2015
Electromagnetic compatibility - Requirements for household appliances, electric tools
and similar apparatus - Part 2: Immunity
EN55014-2:2015
ESD Electrostatic discharge immunity test
Air: ±2, 4, 8kV
Contact: ±2, 4kV EN61000-4-2: 2009, Criteria B
Radiated, radio-frequency, electromagnetic field immunity test
10V/m, 80MHz-1GHz
3V/m, 1.4GHz-2GHz
1V/m, 2GHz-2.7GHz
EN61000-4-3: 2006 + A1, 2009, Criteria A
Fast Transient and Burst Immunity
AC and DC Port: ±2kV EN61000-4-4: 2012, Criteria B
Surge Immunity
AC In Port (L-N): ±1kV
DC Output Port: ±0.5kV EN61000-4-5: 2014 +A1:2017, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields
AC and DC Port: 10V EN61000-4-6: 2014, Criteria A
Power Magnetic Field Immunity
50Hz, 30A/m EN61000-4-8: 2010, Criteria A
Voltage Dips and Interruptions
Voltage Dips: 30%
Voltage Dips: 60%
Voltage Dips: 100%
Interruptions: >95%
EN61000-4-11:2004 + A1:2017, Criteria C
EN61000-4-11:2004 + A1:2017, Criteria C
EN61000-4-11:2014 + A1:2017, Criteria B
EN61000-4-11: 2014 + A1:2017,Criteria C
Voltage Fluctuations and Flicker in Public Low-Voltage Systems <=16A per phase
EN61000-3-3: 2013
Limitations on the amount of electromagnetic interference allowed from digital and electronic devices
FCC 47 CFR Part 15 Supbart B, Class B
Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the Range of 9 kHz to 40 GHz ANSI C63.4-2014, Class B
Notes:
Note11: If output is connected to GND, please contact RECOM tech support for advice
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/277
Series
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
case, baseplate
potting
PCB
plastic, (UL94 V-0)
silicone, (UL94 V-0)
FR4, (UL94 V-0)
Dimension (LxWxH) THT/wired 31.7 x 26.7 x 21.8mm
Weight THT
wired
31.5g typ.
37.0g typ.
continued on next page
www.recom-power.com REV.: 3/2019 PA-6
Dimension Drawing THT (mm)
Pin Connections
Pin # Single
1 VAC in (N)
5 VAC in (L)
7 +Vout
9 -Vout
Tolerance: xx.x= ±0.8mm
xx.xx= ±0.25mm
Ø0.80+0.10 / -0.05
embossed logo
26.7
31.7
21.8
26.1 31.1
Bottom View
4.0
±1.0
1
5
9
7
20.00
5.85
20.00
10.85 10.00
3.35
Top View
1
5
9
7
Recommended Footprint Details
Dimension Drawing Wired (mm)
Wired information
# Function Wire color Type AWG
1 VAC in (N) blue UL-1015 18
5 VAC in (L) brown UL-1015 18
7 +Vout red UL-1015 18
9 -Vout black UL-1015 18
Tolerance: xx.x= ±0.8mm
xx.xx= ±0.25mm
embossed logo
26.7
31.7
21.8100.0 ±10.04.50
26.1 31.1
Bottom View
1
5
9
7
Ø2.7
2.50
5 ±2
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RAC05-K/277
Series
www.recom-power.com REV.: 3/2019 PA-7
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.
PACKAGING INFORMATION
Parameter Type Value
Packaging Dimension (LxWxH) THT
wired
tube
tray
466.0 x 30.4 x 29.3mm
468.0 x 198.0 x 46.0mm
Packaging Quantity THT
wired
12pcs
24pcs
Storage Temperature Range -40°C to +85°C
Storage Humidity non-condensing 20% to 90% RH max.