0
50
100
150
200
250
-40-20020406080
Load Current (mA)
LCA220 I(F) = 5 mA
0
50
100
150
200
250
300
350
400
450
500
-40-200 20406080
MOSFET Breakdown Voltage (Volts)
LCA220
I(F) = 0 mA
-60%
-35%
-10%
15%
40%
65%
90%
115%
140%
-40-20020406080
Change in On Resistance (%)
Normalized to 25 ˚ C
LCA220 I(F) = 5 mA
I(L) = 50 mA
-60%
-10%
40%
90%
140%
190%
240%
-40-20020406080
Change in Turn On Time (%)
Normalized to 25 ˚ C
LCA220 I(F) = 5 mA
I(L) = 50 mA
-110%
-60%
-10%
40%
90%
140%
-40 -20 0 20 40 60 80
Change in Turn Off Time (%)
Normalized to 25 ˚ C
LCA220
I(F) = 5 mA
I(L) = 50 mA
0
1000
2000
3000
4000
5000
0 5 10 15 20 25 30 35 40 45 50 55
Turn On Time (
µSec.)
LCA220
T = 25 deg. C
I(L) = 50 mA
30
40
50
60
70
80
90
0 5 10 15 20 25 30 35 40 45 50 55
Turn Off Time (µSec.)
LCA220
T = 25 deg. C
I(L) = 50 mA
Photomos / 2 FORM A
A. Load Current vs. Ambient Temperature B. Output MOSFET BV vs. Ambient Temperature
C. On-Resistance vs. Ambient Temperature
D. On Time vs. Ambient Temperature E. Turn Off Time vs. Ambient Temperature
F. Turn On Time vs. LED Forward Current G. Turn Off Time vs. LED Forward Current
Temperature (Deg C) Temperature (Deg C)
Temperature (Deg C)
Temperature (Deg C) Temperature (Deg C)
LED Forward Current (mA) LED Forward Current (mA)
Page 2 of 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com
WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506