SPECIFICATION
100W Constant Current Mode LED Driver HVGC-100 series
File Name:HVGC-100-SPEC 2018-09-30
MODEL
RATED CURRENT
RATED POWER
OUTPUT CURRENT ADJ. RANGE
SET UP TIME Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER TEMPERATURE
OVER VOLTAGE
Adjustable for A/AB-Type only (via built-in potentiometer)
47 ~ 63Hz
0.38A / 347VAC 0.28A / 480VAC
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
186.1K hrs min. MIL-HDBK-217F (25 )℃
236*68*38.8mm (L*W*H)
ENVIRONMENT
SAFETY &
EMC
PROTECTION
300 ~ 320V
Shut down o/p voltage, recovers automatically after temperature goes down
Shut down o/p voltage with auto-recovery or re-power on to recovery
SHORT CIRCUIT
91%
HVGC-100-350 HVGC-100-700
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020
Constant current limiting, recovers automatically after fault condition is removed
<0.75mA / 480VAC
210 ~ 350mA 420 ~ 700mA
350mA
99.75W
29 ~ 285V
1.18Kg; 12pcs/15.2Kg/0.74CUFT
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
UL8750 CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13, approved;
,
EAC TP TC 004 IP65 or IP67,
design refer to UL60950-1, TUV EN60950-1
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
91%
150 ~ 160V
700mA
99.4W
15 ~ 142V
EMC IMMUNITY
EMC EMISSION
CURRENT TOLERANCE ±5.0%
Compliance to EN55015, EN61000-3-2 Class C ( 50%) ; EN61000-3-3, FCC Part 15 Subpart, EAC TP TC 020≧@ load
COLD START 25A(t =900 s measured at 50% I ) at 480VAC;
width peak Per NEMA 410
μ
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 480VAC
CONSTANT CURRENT REGION
Note.2
CURRENT RIPPLE Note.5 5.0% max. @rated current
500ms, 80ms /230VAC, 347VAC, 480VAC
180 ~ 528VAC 254VDC ~ 747VDC
(Please refer to "STATIC CHARACTERISTIC" section)
VOLTAGE RANGE Note.3
PF 0.9 /230VAC, PF 0.9 /277VAC full load≧≧≧≧8 8 , PF 0.97/347VAC, PF 0.93/480VAC @
(Please refer to " " )POWER FACTOR (PF) CHARACTERISTIC section
THD< 20%(@ load 50%/230VAC, 277VAC, 347VAC; @ load 75%/480VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
Tcase=-40 ~ +90 (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)℃
MAX. CASE TEMP. Tcase=+90℃
WORKING TEMP.
1. All parameters NOT specially mentioned are measured at 347VAC input, rated current and 25 of ambient temperature.℃
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
4. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
5. It is measured 50% ~ 100% of maximum voltage under rated power delivery.
6. The is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by thedriver
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED can only be used behind a switch without permanently
driver
connected to the mains.
8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.℃
9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
10. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
11. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf