DRQ-12/50-L48 Series www.murata-ps.com 600W Digital Fully Regulated Intermediate DC-DC Bus Converter PRODUCT OVERVIEW Typical unit Typic FEATURES Fixed DC outputs, 12V @ 50A Advanced Bus Converter industry standard quarter-brick with digital PMBusTM interface Optional five pin version (DOSA compatible pinouts) 44-60 VDC input range The DRQ 600W series provides a fully regulated, digitally controlled DC output in a 1/4-brick format that will support the evolving Advanced Bus Converter (ABC) industry standard footprint for isolated v bboard mounted power modules. The DRQ series ssupports advances in power conversion technology iincluding a digital interface supporting the PMBus protocol for communications to power modules. p The DRQ series offers high output current (up to 550 Amps) in an industry standard "quarter brick" ppackage. The DRQ series is an isolated, regulated, 600W-12Vout quarter brick that has an input range of 44-60Vdc with a typical efficiency of 96%. The DRQ-12/50-L48 is ideal for intermediate bus applications. A digitally controlled version is also available with the Advanced Bus Converter (ABC) pinout. Advanced automated surface mount assembly and planar magnetics deliver galvanic isolation rated at 2250 Vdc for functional insulation. Target markets include Networking Equipment, Power over Ethernet applications, Wireless Networking Equipment, Telecommunications Equipment, Wireless pre-amplifiers, Industrial and test equipment, 12V Fan trays and applications requiring a regulated 12V output. A wealth of self-protection features include input undervoltage lockout and overtemperature shutdown; over current protection using the "hiccup" autorestart technique, provides indefinite shortcircuit protection, along with output OVP. The DRQ series is certified to safety standards UL/IEC/CSA 60950-1, 2nd edition. It meets RFI/EMI conducted emission compliance to EN55022, CISPR22 with an external filter. Load sharing option Baseplate & heatsink options APPLICATIONS 96% typical efficiency Embedded systems, datacom and telecom installations, wireless base stations Disk farms, data centers and cellular repeater sites 2250 VDC isolation Certified to UL 60950-1, CSA-C22.2 No. 60950-1, 2nd edition safety approvals Extensive self-protection, OVP, input undervoltage, current limiting and thermal shutdown F1 Remote sensor systems, dedicated controllers Instrumentation systems, R&D platforms, automated test fixtures Data concentrators, voice forwarding and speech processing systems +Vin (1) +Vout (8) Barrier External DC Power Source On/Off Control (2) Open = On Controller and Power Reference and Error Amplifier logic) -Vin (3) -Vout (4) Figure 1. Connection Diagram (without digital interface) Typical topology is shown. Murata Power Solutions recommends an external fuse. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 1 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter PERFORMANCE SPECIFICATIONS SUMMARY AND ORDERING GUIDE Output Root Model DRQ-12/50-L48 Input R/N (mV IOUT pk-pk) VOUT (Amps, Power (Volts) max.) (Watts) Typ. Max. 12 50 600 150 200 Regulation (mV, max.) Line Load 100 120 IIN full VIN Nom. Range IIN no load (Volts) (Volts) load (mA) (Amps) Please refer to the part number structure for additional ordering information and options. All specifications are typical at nominal line voltage and full load, +25C unless otherwise noted. See 48 44-60 150 13.02 Efficiency Min. Typ. 95% 96% Dimensions with heat sink (inches) (mm) 2.3 x 1.45 x 1.1 58.4 x 36.8 x 27.94 detailed specifications. Output capacitors are 1 F || 10 F. These caps are necessary for our test equipment and may not be needed for your application. PART NUMBER STRUCTURE DRQ - 12 / 50 - L48 N B S A Lx - C RoHS Hazardous Materials compliance C = RoHS-6 (does not claim EU RoHS exemption 7b-lead in solder), standard Digital Regulated Quarter-brick Pin length option Blank = Standard pin length 0.180 in. (4.6 mm) L1 = 0.110 in. (2.79 mm) L2 = 0.145 in. (3.68 mm) Nominal Output Voltage A = PMBusTM (ABC 16-pin pinout) Blank = No PMBusTM (DOSA 5-pin pinout) Maximum Rated Output Current in Amps Input Voltage Range: L48 = 44-60 Volts (48V nominal) S = Load-Sharing option Baseplate or Integrated Heat Sink (optional) B = Baseplate installed K = Integrated Heat Sink On/Off Control Logic N = Negative logic To Be Discontinued * P = Positive logic Special quantity order is required; samples available with standard pin length only. Some model number combinations may not be available. See website or contact your local Murata sales representative. Complete Model Number Example: DRQ-12/50-L48NKL1-C Negative On/Off logic, Integrated Heat Sink installed, 0.110 pin length, RoHS-6 compliance To Be Discontinued * NOTE: The following products are To Be Discontinued. DRQ-12/50-L48PBA-C DRQ-12/50-L48PBAL2-C DRQ-12/50-L48PB-C DRQ-12/50-L48PBL2-C DRQ-12/50-L48PBSA-C DRQ-12/50-L48PBSAL2-C DRQ-12/50-L48PBS-C DRQ-12/50-L48PBSL2-C DRQ-12/50-L48PKA-C DRQ-12/50-L48PKAL2-C DRQ-12/50-L48PK-C DRQ-12/50-L48PKL2-C DRQ-12/50-L48PKSA-C DRQ-12/50-L48PKSAL2-C DRQ-12/50-L48PKS-C DRQ-12/50-L48PKSL2-C www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 2 of 26 * Last Time Buy date is 3/31/2019. Please click here to view the Discontinuance Notification. DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter FUNCTIONAL SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS Input Voltage, Continuous Isolation Voltage On/Off Remote Control Output Power Conditions Minimum Typical/Nominal 0 Input to output, continuous Power on, referred to -Vin 0 0 Maximum Units 60 2250 13.5 612 Vdc Vdc Vdc W Current-limited, no damage, short-circuit 0 50 A protected Storage Temperature Range Vin = Zero (no power) -55 125 C Absolute maximums are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied or recommended. Output Current INPUT Operating voltage range Recommended External Fuse Start-up threshold Undervoltage shutdown Overvoltage Shutdown Overvoltage Recover Internal Filter Type Input current Full Load Conditions Low Line Inrush Transient Short Circuit Input Current No Load Input Current Shut-Down Input Current (Off, UV, OT) Reflected (back) ripple current Pre-biased startup Conditions 44 Fast blow Rising input voltage Falling input voltage 41 39 64 62 Vin = nominal Vin = minimum 48 25 42 40 66 64 Pi 13.02 14.2 0.15 0.05 150 10 100 Monotonic Iout = minimum, unit = ON Measured at input with specified filter External output voltage < Vset 60 43 41 68 66 Vdc A Vdc Vdc Vdc Vdc 14.02 14.28 0.30 0.1 200 20 180 A A A2-Sec. A mA mA mA, p-p GENERAL and SAFETY Efficiency Isolation Isolation Voltage Isolation Voltage Isolation Voltage Insulation Safety Rating Isolation Resistance Isolation Capacitance Safety Calculated MTBF Vin = 48V, full load Vin = min., full load 95 95.5 96 96 Input to output, continuous Input to baseplate, continuous Output to baseplate, continuous % % 2250 1500 1500 functional 10 1500 Certified to UL-60950-1, CSA-C22.2 No. 609501, IEC 60950-1, 2nd edition Per Telcordia SR332, issue 2, class 3, method 1, ground fixed, Tambient = +25C Vdc Vdc Vdc M pF Yes Hours x 106 3.2 DYNAMIC CHARACTERISTICS Fix Frequency Control Vin Startup delay time Enable startup delay time Rise Time Dynamic Load Response Dynamic Load Peak Deviation 150 25 3 15 Power on to Vout regulated Remote ON to Vout regulated 50-75-50% load step, settling time to within 1% of Vout (Cout=3300F) same as above 30 5 20 KHz mS mS mS 200 250 Sec 250 300 mV FEATURES and OPTIONS Remote On/Off Control "N" suffix: Negative Logic, ON state Negative Logic, OFF state Control Pin Shutdown Current Control Pin On Current "P" suffix: Positive Logic, ON state Positive Logic, OFF state Control Pin Shutdown Current Control Pin On Current ON = Ground pin or external voltage OFF = Pin open or external voltage Open collector/drain -0.1 3.5 0.8 13.5 5 1 V V mA mA ON = Pin open or external voltage OFF = Ground pin or external voltage Open collector/drain 3.5 0 13.5 0.8 1 5 V V mA mA www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 3 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter FUNCTIONAL SPECIFICATIONS, (CONT.) OUTPUT Total Output Power Voltage Nominal Output Voltage Setting Accuracy Output Voltage Overvoltage Protection Current Output Current Range Minimum Load Current Limit Inception Short Circuit Short Circuit Current Short Circuit Duration (remove short for recovery) Short circuit protection method Regulation Line Regulation Load Regulation Ripple and Noise Temperature Coefficient Maximum Capacitive Loading Conditions Minimum Typical/Nominal Maximum Units 0 600 612 W 11.76 -2 11.95 13.8 12 12.24 2 12.05 15.6 Vdc % of Vnom Vdc Vdc 50 A 58 60 A Hiccup technique, autorecovery within 1.25% of Vout 0.4 1 A Output shorted to ground, no damage Continuous 100 120 200 0.02 10,000 mV mV mV pk-pk % of Vout./C F No trim, all conditions At 50% load, no trim @Vin=48V, Iout=0, Ta=+25C Via magnetic feedback 14.4 0 90% of Vout, after warmup 56 Current limiting 40 40 150 Iout = min. to max. 5 Hz- 20 MHz BW At all outputs Low ESR MECHANICAL (Through Hole Models) Outline Dimensions with heat sink (Please refer to outline drawing) Outline Dimensions with baseplate (Please refer to outline drawing) Weight with heat sink 2.3 x 1.45 x 1.1 58.4 x 36.83 x 27.94 2.3 x 1.45 x .052 58.4x 36.83x 13.2 3.38 96 2.63 74.5 0.04 & 0.062 1.016 & 1.575 Copper alloy 98.4-299 4.7-19.6 LxWxH LxWxH Weight with baseplate Through Hole Pin Diameter Through Hole Pin Material TH Pin Plating Metal and Thickness Nickel subplate Gold overplate Inches mm Inches mm Ounces Grams Ounces Grams Inches mm -inches -inches ENVIRONMENTAL Operating Ambient Temperature Range Operating Case Temperature Storage Temperature Thermal Protection/Shutdown Electromagnetic Interference Conducted, EN55022/CISPR22 RoHS rating See Derating No derating Vin = Zero (no power) Measured in center External filter is required -40 -40 -55 85 110 125 135 B RoHS-6 C C C C Class Notes Unless otherwise noted, all specifications apply at Vin = nominal, nominal output voltage and full output load. General conditions are near sea level altitude, no base plate installed and natural convection airflow unless otherwise specified. All models are tested and specified with external parallel 1 F and 10 F output capacitors (see Technical Notes). All capacitors are low-ESR types wired close to the converter. These capacitors are necessary for our test equipment and may not be needed in the user's application. Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth. Input filtering is Cin = 33 F/100V, Cbus = 220F/100V and Lbus = 12 H. All models are stable and regulate to specification under no load. The Remote On/Off Control is referred to -Vin. Regulation specifications describe the output voltage changes as the line voltage or load current is varied from its nominal or midpoint value to either extreme. The load step is 25% of full load current. Output Ripple and Noise is measured with Cout = 1 F || 10 F, 20 MHz oscilloscope bandwidth and full resistive load. www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 4 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter PERFORMANCE DATA Efficiency vs. Line Voltage and Load Current @ +25C 98 96 Efficiency (%) 94 VIN = 44V VIN = 48V VIN = 60V 92 90 88 86 84 5 10 15 20 25 30 35 40 45 Load Current (Amps) Maximum Current Temperature Derating at sea level (Vin = 48V, airflow from -Vin to +Vin, with heat sink) 60 60 50 50 Output Current (Amps) Output Current (Amps) Maximum Current Temperature Derating at sea level (Vin = 44V, airflow from -Vin to +Vin, with heat sink) 40 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 30 20 10 40 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 30 20 10 0 0 40 50 60 70 80 85 40 50 Ambient Temperature (C) 70 80 85 Maximum Current Temperature Derating at sea level (Vin = 60V, airflow from -Vin to +Vin, with heat sink) 60 60 50 50 Output Current (Amps) Output Current (Amps) Maximum Current Temperature Derating at sea level (Vin = 54V, airflow from -Vin to +Vin, with heat sink) 40 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 30 60 Ambient Temperature (C) 20 10 40 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 30 20 10 0 0 40 50 60 70 Ambient Temperature (C) 80 85 40 50 60 70 80 85 Ambient Temperature (C) www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 5 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter Transverse Longitudinal Maximum Current Temperature Derating at sea level (Vin = 44V, airflow from -Vin to +Vin, with baseplate) Maximum Current Temperature Derating at sea level (Vin = 44V, airflow from Vin to Vout, with baseplate) 60 60 55 55 50 50 45 45 Output Current (Amps) Output Current (Amps) PERFORMANCE DATA 40 35 30 25 20 15 10 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 2.5 m/s (500 LFM) 3.0 m/s (600 LFM) 40 35 30 25 20 15 10 5 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 2.5 m/s (500 LFM) 3.0 m/s (600 LFM) 5 0 0 40 45 50 55 60 65 70 75 80 85 40 45 50 55 Ambient Temperature (C) 55 50 50 45 45 Output Current (Amps) Output Current (Amps) 60 55 40 35 30 15 10 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 2.5 m/s (500 LFM) 3.0 m/s (600 LFM) 75 80 85 80 85 80 85 40 35 30 25 20 15 10 5 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 2.5 m/s (500 LFM) 3.0 m/s (600 LFM) 5 0 0 40 45 50 55 60 65 70 75 80 85 40 45 50 55 Ambient Temperature (C) 55 50 50 45 45 Output Current (Amps) 60 55 40 35 30 20 15 10 65 70 75 Maximum Current Temperature Derating at sea level (Vin = 60V, airflow from Vin to Vout, with baseplate) 60 25 60 Ambient Temperature (C) Maximum Current Temperature Derating at sea level (Vin = 60V, airflow from -Vin to +Vin, with baseplate) Output Current (Amps) 70 Maximum Current Temperature Derating at sea level (Vin = 48V, airflow from Vin to Vout, with baseplate) 60 20 65 Ambient Temperature (C) Maximum Current Temperature Derating at sea level (Vin = 48V, airflow from -Vin to +Vin, with baseplate) 25 60 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 2.5 m/s (500 LFM) 3.0 m/s (600 LFM) 40 35 30 25 20 15 10 5 5 0 0.5 m/s (100 LFM) 1.0 m/s (200 LFM) 1.5 m/s (300 LFM) 2.0 m/s (400 LFM) 2.5 m/s (500 LFM) 3.0 m/s (600 LFM) 0 40 45 50 55 60 65 Ambient Temperature (C) 70 75 80 85 40 45 50 55 60 65 70 75 Ambient Temperature (C) www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 6 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter PERFORMANCE DATA Enable Startup Delay (Vin = 48V, Iout = 50A, Cout = 10000F, Ta = +25C) Ch2 = Vout, Ch4 = Enable. Startup Delay (Vin = 48V, Iout = 50A, Cout = 10000F, Ta = +25C) Ch1 = Vin, Ch2 = Vout. Stepload Transient Response (Vin = 48V, Iout = 50-75-50% of Iout, Cload = 1000F) Stepload Transient Response (Vin = 48V, Iout = 25-75-25% of Iout, Cload = 1000F) Output Ripple & Noise (Vin = 48V, Iout = 0A, Cout = 1F || 10F, Ta = +25C) Output Ripple & Noise (Vin = 48V, Iout = 50A, Cout = 1F || 10F, Ta = +25C) www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 7 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter PERFORMANCE DATA Output v. Input Voltage @ 50% Load 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 VIN OFF VIN ON Output Voltage 12 10 VIN OFF 8 VIN ON 6 4 2 39.0 39.4 39.8 40.2 40.6 41.0 41.4 41.8 42.2 42.6 43.0 43.4 43.8 0 39.0 39.4 39.8 40.2 40.6 41.0 41.4 41.8 42.2 42.6 43.0 43.4 43.8 Output Voltage Output v. Input Voltage @ No Load 13 12 11 10 9 8 7 6 5 4 3 2 1 0 VIN OFF VIN ON 39.0 39.4 39.8 40.2 40.6 41.0 41.4 41.8 42.2 42.6 43.0 43.4 43.8 Output Voltage Output v. Input Voltage @ Full Load www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 8 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter ABC (PMBUS) MECHANICAL SPECIFICATIONS WITH HEAT SINK [36.8] 1.45 NOTES: UNLESS OTHERWISE SPECIFIED: 1: ALL DIMENSIONS ARE IN INCHES [MILLIMETERS]; 2: ALL TOLERANCES: x.xxin, 0.02in (x.xmm, 0.5mm) x.xxxin, 0.01in (x.xxmm, 0.25mm) 3: COMPONENTS WILL VARY BETWEEN MODELS 4: STANDARD PIN LENGTH: 0.180 Inch FOR PIN LENGTH OPTIONS, SEE PART NUMBER STRUCTURE. 1.10 [28.0]Max [58.4] 2.30 L SEE NOTE 4 PIN S 1-3,: I 0.040 0.0015 (1.016 0.038 ) Shoulde r: I 0.076 0.005 (1.930.13) PIN S 4,8: I 0.062 0.0015 (1.575 0.038 ) Shoul de r: I 0.098 0.005 (2.490.13) 0.010 minimum clearance between standoffs and highest component [10.80] 0.425 [50.80] 2.000 ISOMETRIC VIEW 5 2 6 7 8 9 10 11 12 13 14 15 1 16 PIN SIDE VIEW [10.80] 0.425 4 [15.24] 0.600 [15.24] 0.600 0.079 [2.0] Pin SQ 0.02 [0.50] 0.079 [2.0] INPUT/OUTPUT CONNECTIONS Designation Function 1 +VIN Positive Input 2 On/Off 1 Control Primary On/Off Control 3 No Pin No Pin 4 -VIN Negative Input 5 -VOUT Negative Output 6 +S Positive Remote Sense 7 -S Negative Remote Sense 8 SA0 Address Pin 0 9 SA1 Address Pin 1 10 SCL PMBus Clock 11 SDA PMBus Data 12 PG Power Good Output 13 DGND PMBus Ground 14 SMBALERT PMBus Alert Signal 15 On/Off 2 Control Secondary On/Off Control 16 +VOUT Positive Output Dimensions are in inches (mm) shown for ref. only. Third Angle Projection Tolerances (unless otherwise specified): .XX 0.02 (0.5) .XXX 0.010 (0.25) Angles 2 www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 9 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter ABC (PMBUS) MECHANICAL SPECIFICATIONS WITH BASEPLATE [26.16] 1.030 NOTES: UNLESS OTHERWISE SPECIFIED: 1: M3 SCREW USED TO BOLT UNIT'S BASEPLATE TO OTHER SURFACES (SUCH AS HEATSINK) MUST NOT EXCEED 0.11''(2.8mm) DEPTH BELOW THE SURFACE OF BASEPLATE 2: APPLIED TORQUE PER SCREW SHOULD NOT EXCEED 5.3In-lb (0.6Nm); 3: ALL DIMENSIONS ARE IN INCHES [MILIMETERS]; 4: ALL TOLERANCES: x.xxin, 0.02in (x.xmm, 0.5mm) x.xxxin, 0.01in (x.xxmm, 0.25mm) 5: COMPONENTS WILL VARY BETWEEN MODELS 6: STANDARD PIN LENGTH: 0.180 Inch FOR PIN LENGTH OPTIONS, SEE PART NUMBER STRUCTURE. M3 THREAD TYP 3PL [5.59] 0.220 [47.24] 1.860 [13.2] 0.52 Max [36.8] 1.45 [5.33] 0.210 [58.4] 2.30 WITH BASEPLATE OPTION L SEE NOTE 6 PINS 1-3: I0.0400.0015(1.0160.038) Shoulder: I0.0760.005(1.930.13) PINS 4,8: I0.0620.0015(1.5750.038) Shoulder: I0.0980.005(2.490.13) 0.010 minimum clearance between standoffs and highest component [50.80] 2.000 4 5 2 6 8 10 12 14 7 9 11 13 15 16 1 [15.24] 0.600 [15.24] 0.600 0.079 [2.0] Pin [0.50] SQ 0.02 PIN SIDE VIEW 0.079 [2.0] ISOMETRIC VIEWCONNECTIONS INPUT/OUTPUT Designation Function 1 +VIN Positive Input 2 On/Off 1 Control Primary On/Off Control 3 No Pin No Pin 4 -VIN Negative Input 5 -VOUT Negative Output 6 +S Positive Remote Sense 7 -S Negative Remote Sense 8 SA0 Address Pin 0 9 SA1 Address Pin 1 10 SCL PMBus Clock 11 SDA PMBus Data 12 PG Power Good Output 13 DGND PMBus Ground 14 SMBALERT PMBus Alert Signal 15 On/Off 2 Control Secondary On/Off Control 16 +VOUT Positive Output Dimensions are in inches (mm) shown for ref. only. Third Angle Projection Tolerances (unless otherwise specified): .XX 0.02 (0.5) .XXX 0.010 (0.25) Angles 2 www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 10 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter ABC (PMBUS) RECOMMENDED FOOTPRINT (2x) 0.120 3.05 MIN FOR PIN SHOULDERS 2.32 0.02 58.93 0.50 (3x) 0.100 2.54 MIN FOR PIN SHOULDERS 2.000 0.010 50.80 0.25 (2x) 0.082 0.005 2.08 0.13 CL (10x) 1 14 12 10 8 6 2 4 15 13 11 9 7 CL 5 (4x) (3x) 0.060 0.005 1.52 0.13 1.000 0.010 25.40 0.25 0.457 0.010 11.62 0.25 16 0.079 0.010 2 0.25 0.300 0.010 7.62 0.25 0.600 0.010 15.24 0.25 1.47 0.02 37.34 0.50 0.051 0.005 1.30 0.13 0.079 0.010 2 0.25 1.961 0.010 49.80 0.25 TOP VIEW www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 11 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter [36.8] 1.45 MECHANICAL SPECIFICATIONS (NO PMBUS) WITH HEAT SINK [58.4] 2.30 L [28] 1.10 Max SEE NOTE 4 NOTES: UNLESS OTHERWISE SPECIFIED: 1: ALL DIMENSIONS ARE IN INCHES [MILLIMETERS]; 2: ALL TOLERANCES: x.xxin, 0.02in (x.xmm, 0.5mm) x.xxxin, 0.01in (x.xxmm, 0.25mm) 3: COMPONENTS WILL VARY BETWEEN MODELS 4: STANDARD PIN LENGTH: 0.180 Inch FOR PIN LENGTH OPTIONS, SEE PART NUMBER STRUCTURE. 5: DOSA 5 PIN COMPATIBLE PIN S 1-3,: I 0.040 0.0015 (1.016 0.038 ) Shoulde r: I 0.076 0.005 (1.93 0.13 ) PIN S 4,8: I 0.062 0.0015 (1.575 0.038 ) Shoul de r: I 0.098 0.005 (2.49 0.13 ) 0.010 minimum clearance between standoffs and highest component 4 2 [10.80] 0.425 3 [15.24] 0.600 [15.24] 0.600 [10.80] 0.425 [50.80] 2.000 1 8 PIN SIDE VIEW ISOMETRIC VIEW Dimensions are in inches (mm) shown for ref. only. Third Angle Projection Tolerances (unless otherwise specified): .XX 0.02 (0.5) .XXX 0.010 (0.25) Angles 2 I/O Connections Pin 1 2 3 4 8 Function +Vin Remote On/Off Control -Vin -Vout +Vout www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 12 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter MECHANICAL SPECIFICATIONS (NO PMBUS) WITH BASEPLATE [36.8] 1.45 [26.16] 1.030 [5.33] 0.210 [58.4] 2.30 NOTES: UNLESS OTHERWISE SPECIFIED: 1: M3 SCREW USED TO BOLT UNIT'S BASEPLATE TO OTHER SURFACES (SUCH AS HEATSINK) MUST NOT EXCEED 0.11''(2.8mm) DEPTH BELOW THE SURFACE OF BASEPLATE 2: APPLIED TORQUE PER SCREW SHOULD NOT EXCEED 5.3In-lb (0.6Nm); 3: ALL DIMENSIONS ARE IN INCHES [MILIMETERS]; 4: ALL TOLERANCES: x.xxin, 0.02in (x.xmm, 0.5mm) x.xxxin, 0.01in (x.xxmm, 0.25mm) 5: COMPONENTS WILL VARY BETWEEN MODELS 6: STANDARD PIN LENGTH: 0.180 Inch FOR PIN LENGTH OPTIONS, SEE PART NUMBER STRUCTURE. M3 THREAD TYP 3PL [47.24] 1.860 7: DOSA 5 PIN COMPATIBLE [13.2] 0.52 Max [5.59] 0.220 WITH BASEPLATE OPTION L SEE NOTE 6 PINS 1-3: I0.0400.0015(1.0160.038) Shoulder: I0.0760.005(1.930.13) PINS 4,8: I0.0620.0015(1.5750.038) Shoulder: I0.0980.005(2.490.13) 0.010 minimum clearance between standoffs and highest component [50.80] 2.000 4 [15.24] 0.600 [15.24] 0.600 3 2 1 8 PIN SIDE VIEW ISOMETRIC VIEW Dimensions are in inches (mm) shown for ref. only. Third Angle Projection Tolerances (unless otherwise specified): .XX 0.02 (0.5) .XXX 0.010 (0.25) Angles 2 I/O Connections Pin 1 2 3 4 8 Function +Vin Remote On/Off Control -Vin -Vout +Vout www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 13 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter RECOMMENDED FOOTPRINT (NO PMBUS) (3x) 0.100 2.54 MIN FOR PIN SHOULDERS 2.32 0.02 58.93 0.50 (2x) 2.000 0.010 50.80 0.25 0.082 0.005 2.08 0.13 0.300 0.010 7.62 0.25 0.600 0.010 15.24 0.25 1.47 0.02 37.34 0.50 CL 1 8 2 CL 3 4 (2x) (3x) 0.060 0.005 1.52 0.13 0.120 3.05 MIN FOR PIN SHOULDERS 1.000 0.010 25.40 0.25 TOP VIEW www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 14 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter STANDARD PACKAGING BASEPLATE VERSION 9.92 (251.97) REF HEATSINK VERSION 9.92 (251.97) REF Each static dissipative polyethylene foam tray accommodates 12 converters in a 3 x 4 array. 0.88 (22.35) REF Each static dissipative polyethylene foam tray accommodates 15 converters in a 3 x 5 array. 4.25 (108) .25 closed height 2.75 (69.85) .25 closed height 11.00 (279.4) .25 10.50 (266.7) .25 10.0 (254) .25 Carton accommodates two (2) trays yielding 30 converters per carton 10.0 (254) .25 Carton accommodates two (2) trays yielding 24 converters per carton Dimensions are in inches (mm) shown for ref. only. Third Angle Projection Tolerances (unless otherwise specified): .XX 0.02 (0.5) .XXX 0.010 (0.25) Angles 2 www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 15 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter TECHNICAL NOTES Power Management Overview The module includes a wide range of readable and configurable power management features that are easy to implement with a minimum of external components. Furthermore, the module includes protection features that continuously protect the load from damage due to unexpected system faults. The SMBALERT pin alerts the host if there is a fault in the module. The following product parameters can continuously be monitored by a host: Vout, Iout, Vin, Temperature, and Power Good. The module is distributed with a default configuration suitable for a wide range operation in terms of Vin, Vout, and load. All power management functions can be reconfigured using the PMBus interface. The product provides a PMBus digital interface that enables the user to configure many aspects of the device operation as well as monitor the input and output parameters. Please contact our FAE for special configurations. Soft-start Power Up The default rise time of the ramp up is 20 ms. When starting by applying input voltage the control circuit boot-up time adds an additional 10 ms delay. The soft-start power up of the module can be reconfigured using the PMBus interface. Over Voltage Protection (OVP) The module includes over voltage limiting circuitry for protection of the load. The default OVP limit is 20% above the nominal output voltage. If the output voltage surpasses the OVP limit, the module can respond in different ways. The default response from an over voltage fault is to immediately shut down. The device will continuously check for the presence of the fault condition, and when the fault condition no longer exists the device will be re-enabled. The OVP fault level and fault response can be reconfigured using the PMBus interface. PMBus Interface This module offers a PMBus digital interface that enables the user to configure many characteristics of the device operation as well as to monitor the input and output voltages, output current and device temperature. The module can be used with any standard two-wire I2C or SMBus host device. In addition, the module is compatible with PMBus version 1.2 and includes an SMBALERT line to help alleviate bandwidth limitations related to continuous fault monitoring. The module supports 100 kHz and 400 kHz bus clock frequency only. Monitoring via PMBus A system controller (host device) can monitor a wide variety of parameters through the PMBus interface. The controller can monitor fault conditions by monitoring the SMBALERT pin, which will be asserted when any number of pre-configured fault or warning conditions occur. The system controller can also continuously monitor any number of power conversion parameters including but not limited to the following: * Input voltage * Output voltage * Output current * Module temperature Software Tools for Design and Production For these modules, Murata-PS provides software for configuring and monitoring via the PMBus interface. For more information please contact your local Murata-PS representative. Click here for Application Note AN-63, Digital DC-DC Evaluation Board User Guide. Click here for Application Note AN-64, Murata Power Brick GUI User Guide. Over Current Protection (OCP, Current limit) The module includes current limiting circuitry for protection at continuous over load. The default setting for the product is hicup mode. The current limit could be configured by simply setting the IOUT_OC_FAULT_LIMIT to be greater than the IOUT_OC_WARN_LIMIT. The maximum value that the current limit could be set is 50A. Power Good The module provides Power Good (PG) flag in the Status Word register that indicates the output voltage is within a specified tolerance of its target level and no fault condition exists. The Power Good pin default logic is negative and it can be configured by MFR_PGOOD_POLARITY. www.murata-ps.com/support MDC_DRQ-12/50-L48NK.B03 Page 16 of 26 DRQ-12/50-L48 Series 600W Digital Fully Regulated Intermediate DC-DC Bus Converter PMBus Addressing Figure 2 and the accompanying table display the recommended resistor values for hard-wiring PMBus addresses (1% tolerance resistors recommended): The address is set in the form of two octal (0 to 7) digits, with each pin setting one digit. The resistor values for each digit is shown below. The SA0 and SA1 pins can be configured with a resistor to GND according to the following equation. PMBus Address = 8 x (SA0value) + (SA1 value) If the calculated PMBus address is 0d, 11d or 12d, PMBus address 119d is assigned instead. From a system point of view, the user shall also be aware of further limitations of the addresses as stated in the PMBus Specification. It is not recommended to keep the SA0 and SA1 pins left open. SA0 SA1 R1 R0 Figure 2. Schematic of Connection of Address Resistors PMBus Commands The products are designed to be PMBus compliant. The following tables list the implemented PMBus read commands. For more detailed information see "PMBus Power System Management Protocol Specification, Part I - General Requirements, Transport and Electrical Interface" and "PMBus Power System Management Protocol, Part II - Command Language." Digit (SA0, SA1 index) Resistor Value [k] 0 1 2 3 4 5 6 7 10 22 33 47 68 100 150 220 OVERALL CMD Command Name SMBus Transaction Type: Writing Data SMBus Transaction Type: Reading Data 01h 02h 03h 10h 11h 12h 15h 16h 19h 20h 21h 22h 25h 26h 28h 40h 41h OPERATION2 ON_OFF_CONFIG3 CLEAR_FAULTS WRITE_PROTECT STORE_DEFAULT_ALL4 RESTORE_DEFAULT_ALL4 STORE_USER_ALL4 RESTORE_USER_ALL4 CAPABILITY VOUT_MODE VOUT_COMMAND VOUT_TRIM VOUT_MARGIN_HIGH VOUT_MARGIN_LOW VOUT_DROOP VOUT_OV_FAULT_LIMIT VOUT_OV_FAULT_RESPONSE5 Write Byte Write Byte Send byte Write Byte Send byte Send byte Send byte Send byte N/A N/A Write Word Write Word Write Word Write Word Write Word12 Write Word Write Byte Read Byte Read Byte N/A Read Byte N/A N/A N/A N/A Read Byte Read Byte Read Word Read Word Read Word Read Word Read Word Read Word Read Byte 1 1 0 1 0 0 0 0 1 1 2 2 2 2 2 2 1 0x80 0x1D N/A 0x00 N/A N/A N/A N/A 0xB0 0x17 12.000 0 13.199 8.100 0/1213 14.199 0xB8 42h VOUT_OV_WARN_LIMIT Write Word Read Word 2 46h 47h 4Ah 4Fh 50h 51h 55h 56h IOUT_OC_FAULT_LIMIT IOUT_OC_FAULT_RESPONSE6 IOUT_OC_WARN_LIMIT OT_FAULT_LIMIT OT_FAULT_RESPONSE5 OT_WARN_LIMIT VIN_OV_FAULT_LIMIT VIN_OV_FAULT_RESPONSE7 Write Word Write Byte Write Word Write Word Write Byte Write Word Write Word Write Byte Read Word Read Byte Read Word Read Word Read Byte Read Word Read Word Read Byte 57h VIN_OV_WARN_LIMIT Write Word Read Word 58h VIN_UV_WARN_LIMIT Write Word Read Word 2 42.00 32.00 75.00 59h 5Ah VIN_UV_FAULT_LIMIT VIN_UV_FAULT_RESPONSE7 Write Word Write Byte Read Word Read Byte 2 1 40.00 0xF8 32.00 75.00 Number of Data Default Value Bytes Lower Limit Upper Limit 8.100 13.200 Cross check Unit 8.1<=Vout<=13.215 >VOUT_MARGIN_LOW =8.100 >VOUT_OV_WARN_LIMIT V V V V m V A 8.100 8.100 0 8.100 13.199 13.200 100 15.600 13.500 8.100 15.600 2 1 2 2 1 2 2 1 59.00 0xF8 56.00 135 0xB8 115 66.50 0xF8 0.00 65.00 VOUT_COMMAND >IOUT_OC_WARN_LIMIT 0.00 30 65.00 145 OT_WARN_LIMIT A C 30 32.00 145 110.00 VIN_OV_WARN_LIMIT C V 2 64.50 32.00 110.00 VIN_UV_WARN_LIMIT VIN_UV_FAULT_LIMIT POWER_GOOD_OFF