cui.com
date 09/15/2016 │ page 2 of 4CUI Inc │ SERIES: SMI5-USB │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current at 115/230 Vac 0.2 A
leakage current 0.02 mA
no load power consumption
at 115/230 Vac, 60/50 Hz
Level VI
CoC Tier 2
0.075
0.075
W
W
OUTPUT
parameter conditions/description min typ max units
line regulation ±5 %
load regulation ±5 %
turn on time 3 s
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection 10 Vdc
over current protection output shut down, auto recovery 1.5 A
short circuit protection
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output at 10 mA for 1 minute 3,000
4,242
Vac
Vdc
safety approvals UL/cUL, GS, RCM, CCC, PSE
EMI/EMC FCCPart15BClassB,CE
MTBF as per Telcordia SR-332 Issue 2, at 115/230 Vac,
full load, 0 ~ 40°C 50,000 hours
RoHS 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 40 °C
storage temperature -20 60 °C
operating humidity non-condensing 20 85 %
storage humidity non-condensing 5 95 %
For more information, please visit the product page | For information on related products, view Dc Power Connectors