Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1701LC Multi-Conductor - Enhanced Category 5e Bonded-Pair Cable For more Information please call 1-800-Belden1 General Description: CAT5e+ (350MHz), 4-Bonded-Pairs, U/UTP-Unshielded, Limited Combustible FHC 25/50, Plenum-CMP, Premise Horizontal Cable, 24 AWG Solid Bare Copper Conductors, FEP Insulation, FEP Jacket. Usage (Overall) Suitable Applications: Premise Horizontal Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422, Noisy Environments Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 4 24 Solid BC - Bare Copper Total Number of Conductors: 8 Insulation Insulation Material: Insulation Trade Name Insulation Material Teflon(R) FEP - Fluorinated Ethylene Propylene Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Teflon FEP - Fluorinated Ethylene Propylene Outer Jacket Diameter: Nom. Dia. (mm) 4.750 Pair Pair Color Code Chart: Number Color 1 White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown Mechanical Characteristics (Overall) Operating Temperature Range: -40C To +150C Bulk Cable Weight: 37.205 Kg/Km Max. Recommended Pulling Tension: 177.928 N Min. Bend Radius/Minor Axis: 25.400 mm Min. Bend/Installation: 48.260 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP, FHC 25/50 NEC Articles: 800 CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes Other Standards: ISO/IEC 11801 ed 2.1 (2008) Class D Page 1 of 3 01-09-2015 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1701LC Multi-Conductor - Enhanced Category 5e Bonded-Pair Cable EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Telecommunications Standards: Category 5e - TIA 568.C.2 Other Specification: NEMA WC-63.1 Category 5e, UL Verified to Category 5e Applicable Patents: Country www.belden.com/p Flame Test UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6), UL723 (NFPA 255) CSA Flame Test: FT6 Plenum/Non-Plenum Plenum (Y/N): Yes Plenum Number: 1701A Non-Plenum Number: 1700A Electrical Characteristics (Overall) Nom. Mutual Capacitance: Capacitance (pF/m) 49.215 Maximum Capacitance Unbalance (pF/100 m): 66 Nominal Velocity of Propagation: VP (%) 72 Maximum Delay: Delay (ns/100 m) 510 Max. Delay Skew: Delay Skew (ns/100 m) 25 Maximum Conductor DC Resistance: DCR @ 20C (Ohm/100 m) 9 Max. Operating Voltage - UL: Voltage 300 V RMS Maximum DCR Unbalanced: DCR Unbalance @ 20C (%) 3 Electrical Characteristics-Premise (Overall) Premise Cable Electrical Table 1: Freq. (MHz) Max. Attenuation (dB/100 m) Min. NEXT (dB) Min. PSNEXT (dB) Min. ACR (dB) Min. PSACR (dB) Min RL (dB) 1 2.0 65.3 65.3 63.3 63.3 20.0 4 4.0 56.3 56.3 52.3 52.3 23.0 8 5.7 51.8 51.8 46.1 46.1 24.5 10 6.4 50.3 50.3 43.9 43.9 25.0 16 8.1 47.3 47.3 39.1 39.1 25.0 20 9.2 45.8 45.8 35.2 35.2 25.0 25 10.3 44.3 44.3 34.1 34.1 24.3 31.25 11.6 42.9 42.9 31.3 31.3 23.6 62.5 16.8 38.4 38.4 21.6 21.6 21.5 100 21.7 35.3 35.3 17.1 17.1 20.1 Page 2 of 3 01-09-2015 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1701LC Multi-Conductor - Enhanced Category 5e Bonded-Pair Cable 155 27.7 32.5 32.5 4.7 4.7 19.0 200 32.0 30.8 30.8 3.0 3.0 19.0 250 36.4 29.3 29.3 >0 >0 18.0 300 40.5 28.2 28.2 18.0 310 41.3 27.9 27.9 18.0 350 44.3 27.2 27.2 17.0 Premise Cable Electrical Table 2: Freq. (MHz) Input (Unfitted) Imp. (Ohms) Fitted Impedance Min. ELFEXT (dB) Min. PSELFEXT (dB) 1 100 12 105 10 63.8 60.8 4 100 12 100 10 51.7 48.8 8 100 12 100 10 45.7 42.7 10 100 12 100 10 43.8 40.8 16 100 12 100 10 39.7 36.7 20 100 12 100 10 37.7 34.7 25 100 15 100 10 35.8 32.8 31.25 100 15 100 10 33.9 30.9 62.5 100 15 100 10 27.8 24.9 100 100 15 100 10 23.8 20.8 155 100 18 100 10 19.9 16.9 200 100 18 100 10 17.7 14.7 250 100 20 100 10 15.8 12.8 300 100 20 100 10 14.2 11.2 310 100 20 100 10 13.9 10.9 350 100 22 100 10 12.9 9.9 Notes (Overall) Notes: Belden IBDN. Jacket sequentially marked at 2 ft. intervals. Third party verified to ANSI/TIA-568-C.2, Category 5e. Put Ups and Colors: Item # Putup Ship Weight Color 1701LC 006U1000 1,000 FT 23.000 LB BLUE, LIGHT 1701LC 0061000 1,000 FT 24.000 LB BLUE, LIGHT 1701LC 009U1000 1,000 FT 23.000 LB WHITE 1701LC 0091000 1,000 FT 24.000 LB WHITE Notes Item Desc CAT5E+ 4PRB U/UTP LC BOX C CAT5E+ 4PRB U/UTP LC REEL CAT5E+ 4PRB U/UTP LC BOX C CAT5E+ 4PRB U/UTP LC REEL Notes: C = CRATE REEL PUT-UP. Revision Number: 5 Revision Date: 03-10-2014 (c) 2015 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 01-09-2015