4
Bi-Directional Solid State Relay C60 Series
OPTICALLY ISOLATED 0.5 to 2.5 A
ELECTRICAL SPECIFICATIONS
(25
°
C UNLESS OTHERWISE SPECIFIED)
Part Number Relay Description
C60 Solid State Relay, Terminals for Through Hole Mount
SC60 Solid State Relay, Terminals For Surface Mount
INPUT (CONTROL) SPECIFICATIONS (See Note 1)
Parameter Min Max Units
Control Voltage Range (See Figure 1) 1.1 1.5 Vdc
Input Current (See Figure 1 and Notes 1, 7) 50 mA
Input Current (Guaranteed On), (See Figure 4 and Note 7) 5.0 mA
Turn-Off Voltage (Guaranteed Off) 0.8 Vdc
Re verse Voltage Protection -6 Vdc
OUTPUT (LOAD) SPECIFICATIONS (See Figure 2 And Note 2)
Part Number DC Bi-Directional
Parameter Min Max Min Max Units
Load Voltage Rating
C60-10 60
±
60
Vdc
C60-20 100
±
100
C60-30 200
±
200
C60-40 400
±
400
Output Current Rating
C60-10 2.5
±
1.25
Adc
C60-20 1.5
±
0.75
C60-30 1.0
±
0.50
C60-40 0.5
±
0.25
On Resistance
(See Note 6)
C60-10 0.07 0.28
Ohms
C60-20 0.2 0.7
C60-30 0.45 1.8
C60-40 1.0 4.0
Leakage Current at Maximum Voltage 2.0 1.0
µ
Adc
Turn-On Time @ 10 mA
(See Figure 4 and Note 7) C60-10 4.0 4.0 ms
C60-20,-30,-40 3.0 3.0
Turn-Off Time C60-10 4.0 4.0 ms
C60-20,-30,-40 3.0 3.0
Output Capacitance
C60-10 1000 500
pF
C60-20 500 250
C60-30 400 200
C60-40 400 200
Isolation (Input to Output) 10
9
10
9
Ohms
Dielectric Strength 1500 1500 Vac
Capacitance (Input to Output) 3.0 3.0 pF
Junction Temperature (T
J
)125 125
°
C
FEATURES/BENEFITS
Power FET output with Very
Low On Resistance - Virtually
no offset with very low
leakage and voltage drop.
Optical Isolation - Isolates
control elements from load
transients. Eliminates ground
loops and signal ground
noise.
Three Terminal Output -
Output FETs can be
paralleled externally to
change current load rating.
Floating Output - Allows for
high and low side switching.
Switches High Voltages and
Currents - Voltages to 400
Vdc. Current to 2.5 Adc.
Bi-directional, DC, or AC.
High Noise Immunity -
Control circuit cannot be
triggered by output switching
noise.
6 Pin Mini-DIP Package -
Standard or surface mount
available.
DESCRIPTION
The C60 series solid state relay
is an advanced design capable
of s witching v ery heavy loads in
a ph ysically small 6 pin mini DIP
package. These relays have a
power FET output that ensures
low On resistance, no offset
voltage and low leakage
current. They are versatile and
can be used to switch AC, Bi-
directional or DC loads. Optical
isolation ensures complete
protection of signal lines,
power and ground bus and
control circuits from switching
BL
OC
K DIA
G
RAM
564
123
INPUT OUTPUT
3
CHARACTERISTIC CURVES
C60 Series
CONTROL CURRENT VS. VOLTAGE
25
20
15
10
5
0.9 1.0 1.1 1.2 1.3 1.4 1.5
VOLTS
NOTES:
1. Series resistor is required to limit input current to 50 mA maximum.
4. Loads may be connected to positive or negative referenced power
supplies. Inductive loads must be diode suppressed.
5. Continuous load current is rated under the conditions of still air and
mounted on a printed circuit board.
R
On
= R
(25˚C)
x e
0.006 (T
J
- 25˚C)
2. The input current is 10 mA for all tests unless otherwise specified.
3. The surge current is non repetitive for a maximum duration of 20 ms
(See Figure 3).
6. To calculate ON Resistance for a given junction temperature calculate
the new R
On
using the equation shown below:
7. Turn On Time can be controlled with input control current. Calculate a
new turn-on time:
t
On
=(t
Specification Limit
)(10 mA/I
In
)
MECHANICAL SPECIFICATION
+
-
+
-
A) BI-DIRECTIONAL/AC CONFIGURATION (SEE NOTE 4)
B) DC CONFIGURATION (SEE NOTE 4)
R
S
R
SLOAD
LOAD
LOAD
LOAD
5
6
4
1
2
3
5
6
4
1
2
3
AC/
±
DC
AC/
±
DC
+DC
- DC
- 40˚C25˚C85˚C
CURRENT (mA)
FIGURE 1
5.0
4.0
3.0
2.0
1.0
0510152025
C60 - 10
C60 - 20,-30,-40
TURN ON TIME (ms)
INPUT CURRENT (mA)
TYPICAL TURN-ON TIME VS. INPUT CURRENT
FIGURE 4
0
8. Load voltage rating should be derated 10% at -40˚C
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 1996 TELEDYNE RELAYS Solid State Products1/96
WIRING CONFIGURATIONS
20.0
-20 4010 70
JUNCTION TEMPERATURE ˚C
4.0
8.0
12.0
16.0
SURGE CURRENT VS. JUNCTION TEMPERATURE
SURGE CURRENT (A)
FIGURE 3 (SEE NOTE 3)
0855525-5
C60-10
C60-20
10.0
2.0
4.0
6.0
8.0
0
C60-40
C60-30
BI-DIRECTIONAL
DC
-20
020 40 60 80
1.25
0.25
0.50
0.75
1.00
2.5
2.0
1.5
1.0
0.5
AMBIENT TEMPERATURE ˚CBI-DIRECTIONAL
MAXIMUM LOAD CURRENT VS. TEMPERATURE
0
0
FIGURE 2
100
OUTPUT CURRENT (A)
DC
C60-20
C60-30
C60-40
C60-10
SC
60 -
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
Tolerances (unless otherwise specified)
Operating Temperature Range: -40
°
C to 85
°
C
Storage Temperature Range: -40
°
C to 100
°
C
Case: 6 pin dual In line, filled epoxy.
Weight: 1 gm. maximum
654
321 0.195
(4.95)
0.390 (9.91)
0.250
(6.35)
DATE CODE
0.290
(7.37)
SURFACE MOUNT LAND PATTERN
0.065 (1.65) Min
0.025 (0.64)
Min
0.100
(2.54)
0.200
(5.08)
0.010
(0.25)
0.175
(4.45)
0.018
0.XX =
±
0.010 (
±
0.25)
0.03
0.010
10
°
±
5
°
0.150 Min
0.100
0.085 (2.16)
0.300
0.020 Min
(0.762)
(0.76)
(0.051)
(2.54)
(0.46)
0.XXX =
±
0.005 (
±
0.13)
C
60 -
0.200
564
123
PIN 1
INDEX
(5.08)
(0.25)