Bi-Directional Solid State Relay C60 Series OPTICALLY ISOLATED 0.5 to 2.5 A Part Number Relay Description C60 Solid State Relay, Terminals for Through Hole Mount SC60 Solid State Relay, Terminals For Surface Mount ELECTRICAL SPECIFICATIONS (25C UNLESS OTHERWISE SPECIFIED) FEATURES/BENEFITS INPUT (CONTROL) SPECIFICATIONS (See Note 1) Parameter Min Max Units Control Voltage Range (See Figure 1) 1.1 1.5 Vdc 50 mA Input Current (See Figure 1 and Notes 1, 7) Input Current (Guaranteed On), (See Figure 4 and Note 7) 5.0 mA Turn-Off Voltage (Guaranteed Off) 0.8 Vdc Reverse Voltage Protection -6 Vdc OUTPUT (LOAD) SPECIFICATIONS (See Figure 2 And Note 2) Part Number Parameter DC Min Load Voltage Rating Output Current Rating On Resistance (See Note 6) Turn-Off Time Max Min Max C60-10 60 60 C60-20 100 100 C60-30 200 200 C60-40 400 400 C60-10 2.5 1.25 C60-20 1.5 0.75 C60-30 1.0 0.50 C60-40 0.5 0.25 C60-10 0.07 0.28 C60-20 0.2 0.7 C60-30 0.45 1.8 C60-40 1.0 4.0 2.0 1.0 C60-10 4.0 4.0 C60-20,-30,-40 3.0 3.0 C60-10 4.0 4.0 C60-20,-30,-40 3.0 3.0 C60-10 1000 500 C60-20 500 250 C60-30 400 200 C60-40 400 200 Leakage Current at Maximum Voltage Turn-On Time @ 10 mA (See Figure 4 and Note 7) Bi-Directional Output Capacitance Units * Power FET output with Very Low On Resistance - Virtually no offset with very low leakage and voltage drop. * Optical Isolation - Isolates control elements from load transients. Eliminates ground loops and signal ground noise. * Three Terminal Output Output FETs can be paralleled externally to change current load rating. * Floating Output - Allows for high and low side switching. Vdc Adc * Switches High Voltages and Currents - Voltages to 400 Vdc. Current to 2.5 Adc. Bi-directional, DC, or AC. * High Noise Immunity Control circuit cannot be triggered by output switching noise. * 6 Pin Mini-DIP Package Standard or surface mount available. DESCRIPTION Ohms Adc ms ms pF The C60 series solid state relay is an advanced design capable of switching very heavy loads in a physically small 6 pin mini DIP package. These relays have a power FET output that ensures low On resistance, no offset voltage and low leakage current. They are versatile and can be used to switch AC, Bidirectional or DC loads. Optical isolation ensures complete protection of signal lines, power and ground bus and control circuits from switching BLOCK DIAGRAM Ohms Dielectric Strength 1500 1500 Vac INPUT Junction Temperature (TJ) 125 125 C 4 pF 5 3.0 3 3.0 2 4 Capacitance (Input to Output) 6 109 1 Isolation (Input to Output) 109 OUTPUT C60 Series CHARACTERISTIC CURVES 1.25 2.5 OUTPUT CURRENT (A) 25 CURRENT (mA) 20 15 85C 25C - 40C 10 5 1.00 2.0 C60-10 0.75 1.5 C60-20 0.50 1.0 C60-30 0.25 0.5 C60-40 0 0.9 1.0 1.1 1.2 1.3 1.4 0 1.5 0 -20 VOLTS CONTROL CURRENT VS. VOLTAGE FIGURE 1 20 40 60 80 0 BI-DIRECTIONAL AMBIENT TEMPERATURE C DC MAXIMUM LOAD CURRENT VS. TEMPERATURE 100 FIGURE 2 5.0 20.0 10.0 C60-10 TURN ON TIME (ms) SURGE CURRENT (A) 16.0 8.0 12.0 6.0 C60-20 8.0 4.0 C60-30 4.0 2.0 0 4.0 3.0 2.0 C60 - 10 C60 - 20,-30,-40 1.0 C60-40 0 0 -20 -5 25 55 10 40 70 BI-DIRECTIONAL JUNCTION TEMPERATURE C SURGE CURRENT VS. JUNCTION TEMPERATURE DC 5 85 10 RS DATE CODE 4 0.250 (6.35) 1 6 2 5 3 4 + 0.065 (1.65) Min SC 60 - 0.290 (7.37) 2 LOAD AC/DC LOAD AC/DC 0.200 (5.08) 0.025 (0.64) Min 0.100 (2.54) 1 25 WIRING CONFIGURATIONS MECHANICAL SPECIFICATION 5 20 TYPICAL TURN-ON TIME VS. INPUT CURRENT FIGURE 4 FIGURE 3 (SEE NOTE 3) 6 15 INPUT CURRENT (mA) 3 A) BI-DIRECTIONAL/AC CONFIGURATION (SEE NOTE 4) 0.195 (4.95) 0.390 (9.91) SURFACE MOUNT LAND PATTERN RS 0.175 (4.45) 0.010 (0.25) 0.03 (0.76) 1 6 2 5 3 4 + - 0.018 (0.46) LOAD +DC LOAD - DC 0.300 (0.762) B) DC CONFIGURATION (SEE NOTE 4) 0.085 (2.16) 0.020 Min (0.051) NOTES: 0.150 Min 10 5 0.100 (2.54) 0.200 (5.08) 6 5 PIN 1 INDEX 0.010 (0.25) 4 * Operating Temperature Range: -40 C to 85C * Storage Temperature Range: -40 C to 100C * Weight: 1 gm. maximum * Case: 6 pin dual In line, filled epoxy. C 60 1 2 3 DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS) Tolerances (unless otherwise specified) 0.XX = 0.010 ( 0.25) 0.XXX = 0.005 ( 0.13) 1/96 1. Series resistor is required to limit input current to 50 mA maximum. 2. The input current is 10 mA for all tests unless otherwise specified. 3. The surge current is non repetitive for a maximum duration of 20 ms (See Figure 3). 4. Loads may be connected to positive or negative referenced power supplies. Inductive loads must be diode suppressed. 5. Continuous load current is rated under the conditions of still air and mounted on a printed circuit board. 6. To calculate ON Resistance for a given junction temperature calculate the new ROn using the equation shown below: R On = R(25C) x e0.006 (TJ - 25C) 7. Turn On Time can be controlled with input control current. Calculate a new turn-on time: tOn =(t Specification Limit)(10 mA/IIn) 8. Load voltage rating should be derated 10% at -40C (c) 1996 TELEDYNE RELAYS Solid State Products SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 3