R Short Barrel Inductive Prox E2E 2-WIRE AC Short Barrel 2-Wire AC Prox Sensors Meet IP67 H Thick nickel-plated brass barrel has wrench flats for easy installation H Solid potted internal circuitry withstands shocks and water washdown to IP67 H High visibility indicator H Choose prewired models with or without short-circuit protection and connector models Ordering Information J PREWIRED SENSORS WITHOUT SHORT-CIRCUIT PROTECTION yp Type Size Shielded M8 M12 M18 Sensing g distance 1.5 mm 2 mm 5 mm M30 Unshielded M8 M12 M18 10 mm 2 mm 5 mm 10 mm M30 Part number NO NC E2E-X1R5Y1 E2E-X1R5Y2 E2E-X2Y1-US E2E-X2Y2-US E2E-X5Y1-US E2E-X5Y2-US E2E-X10Y1-US E2E-X10Y2-US E2E-X2MY1-US E2E-X2MY2-US E2E-X5MY1-US E2E-X5MY2-US E2E-X10MY1-US E2E-X10MY2-US E2E-X18MY1-US E2E-X18MY2-US 18 mm *Note: A different oscillating frequency is available to prevent mutual interference. Add a "5" to the part number (e.g., E2E-X5Y15-US). 2 E2E 2-WIRE AC E2E 2-WIRE AC J PREWIRED SENSORS WITH SHORT-CIRCUIT PROTECTION Type yp Size Shielded M18 Sensing g distance M30 Unshielded M18 5 mm 10 mm 10 mm M30 Part number NO NC E2E-X5Y1-53-US E2E-X5Y2-53-US E2E-X10Y1-53-US E2E-X10Y2-53-US E2E-X10MY1-53-US E2E-X10MY2-53-US E2E-X18MY1-53-US E2E-X18MY2-53-US 18 mm J SENSORS WITH BUILT-IN CONNECTORS Connector Type yp Size 4-pin connector (M12) See Note 1. Shielded M12 M18 2 mm 5 mm M30 Unshielded M12 Part number Sensing g distance 10 mm 5 mm M18 10 mm M30 NO NC E2E-X2Y1-M1 E2E-X2Y2-M1 E2E-X5Y1-M1 E2E-X5Y2-M1 E2E-X10Y1-M1 E2E-X10Y2-M1 E2E-X5MY1-M1 E2E-X5MY2-M1 E2E-X10MY1-M1 E2E-X10MY2-M1 E2E-X18MY1-M1 E2E-X18MY2-M1 E2E-X2Y1-M4 E2E-X2Y2-M4 E2E-X5Y1-M4 E2E-X5Y2-M4 E2E-X10Y1-M4 E2E-X10Y2-M4 E2E-X5MY1-M4 E2E-X5MY2-M4 E2E-X10MY1-M4 E2E-X10MY2-M4 E2E-X18MY1-M4 E2E-X18MY2-M4 18 mm 3-pin connector (M12) See Note 2. Shielded M12 M18 M30 Unshielded M12 M18 2 mm 5 mm 10 mm 5 mm 10 mm M30 18 mm Note: 1. Use Omron's Y96E-44jAj connector cordsets. 2. Use Omron's Y96E-33jAj connector cordsets. J ACCESSORIES Description Part number Mounting brackets Fits M8 size sensors Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors Y92E-B8 Y92E-B12 Y92E-B18 Y92E-B30 Silicone rubber covers for shielded sensors Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors Y92E-E12-2 Y92E-E18-2 Y92E-E30-2 Connector cordsets See Y96E Connector Cordsets data sheet for details 3 E2E 2-WIRE AC E2E 2-WIRE AC J REPLACEMENT PARTS Description Part number Mounting hardware including one pair of metal nuts and one washer Fits M8 size sensors Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors M8-MHWS M12-MHWS M18-MHWS M30-MHWS Specifications j) J SENSORS WITHOUT SHORT-CIRCUIT PROTECTION (E2E-XjYj Part number E2E-X1R5Yj Size M8 Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Sensing distance 1.5 mm (0.06 in) 10% 2 mm (0.08 in) 10% 2 mm (0.08 in) 10% 5 mm (0.20 in) 10% 5 mm (0.20 in) 10% 10 mm (0.39 in) 10% 10 mm (0.39 in) 10% 18 mm (0.71 in) 10% Supply voltage (operating voltage range) (See note 1) 24 to 240 VAC, 50/60 Hz (20 to 264 VAC) Current consumption 1.7 mA max. Sensing object Magnetic metals (refer to Engineering Data for non-magnetic metals) Setting distance 0 to 1.2 mm (0 to 0.05 in) 0 to 1.6 mm (0 to 0.06 in) 0 to 1.6 mm (0 to 0.06 in) 0 to 4.0 mm (0 to 0.16 in) 0 to 4.0 mm (0 to 0.16 in) 0 to 8.0 mm (0 to 0.31 in) 0 to 8.0 mm (0 to 0.31 in) 0 to 14.0 mm (0 to 0.55 in) Standard object (mild steel) 8 x 8 x 1 mm (0.31 x 0.31 x 0.04 in) 12 x 12 x 1 mm (0.47 x 0.47 x 0.04 in) 12 x 12 x 1 mm (0.47 x 0.47 x 0.04 in) 15 x 15 x 1 mm (0.59 x 0.59 x 0.04 in) 18 x 18 x 1 mm (0.71 x 0.71 x 0.04 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) 54 x 54 x 1 mm (2.13 x 2.13 x 0.04 in) Differential travel 10% max. of sensing distance Response frequency 25 Hz Operation (with sensing object approaching) Y1 models: Load ON Y2 models: Load OFF Control output (switching capacity) 5 to 100 mA max. Indicator Operation indicator (red LED) Ambient temperature (See note 2) Operating: --25C to 70C (--13F to 158F) with no icing Ambient humidity Operating: 35% to 95% Temperature influence 15% max. of sensing distance at 23C in temperature range of --40C to 85C (--40F to 185F) 10% max. of sensing distance at 23C in temperature range of --25C to 70C (--13F to 158F) Voltage influence 1% max. of sensing distance in rated voltage range 15% Residual voltage Refer to Engineering Data Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case Dielectric strength 4,000 VAC for 1 min between current carry parts and case (2,000 VAC for M8 types) Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z directions Shock resistance 500 m/s2 (approx. 50G) for 10 times each in X, Y, and Z axes Enclosure rating IEC IP67 NEMA 1, 4, 6, 12, 13 E2E-X2MYj E2E-X2Yj -US E2E-X5MY j -US M12 E2E-X5Y j -US E2E-X10MY j -US M18 5 to 200 mA max. E2E-X10Y j -US E2E-X18MY j -US M30 5 to 300 mA max. Operating: --40C to 85C (--40F to 185F) with no icing 1,000 m/s2 (approx. 50G) for 10 times each in X, Y, and Z axes 500 m/s2 (approx. 50G) for E2E-X5M Note: 1. When using an M18 or M30 size E2E at an ambient temperature between 70C and 85C (158F and 185F), make sure that the E2E has a control output of 200 mA maximum. 2. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is --25C to 85C (--13F to 185F). (This table continues on the next page.) 4 E2E 2-WIRE AC E2E 2-WIRE AC Specifications Table -- continued from previous page Part number Approvals pp Weight g Material E2E-X1R5Y j E2E-X2MY j E2E-X2YjUS E2E-X5MYj -US E2E-X5YjUS UL -- Recognized, File Number E76675 CSA -- Certified, File Number LR45951 Prewired Approx. 45 g Connector --- Body Stainless steel Sensing face PBT Approx. 120 g Approx. 25 g E2E-X10MY j -US E2E-X10Y j -US Approx. 160 g Approx. 270 g Approx. 45 g Approx. 125 g E2E-X18MY j -US Approx. 124 g Brass J SENSORS WITH SHORT-CIRCUIT PROTECTION (E2E-Xj jYj j-53-US) Part number Bodyy E2E-X5Yj-53-US Size M18 Type Shielded E2E-X10MYj-53-US E2E-X10Yj-53-US E2E-X18MYj-53-US M30 Unshielded Shielded Unshielded Supply voltage 90 to 140 VAC, 50/60 Hz Effective maximum detecting distance (with standard target) 5 mm (0.20 in) 10% 10 mm (0.40 in) 10% 18 mm (0.71 in) 10% Usable detecting range (with standard target) 0 to 4 mm (0 to 0.16 in) 0 to 8 mm (0 to 0.31 in) 0 to 14 mm (0 to 0.55 in) Standard target size (mild steel, L x W x H) 18 x 18 x 1 mm (0.71 x 0.71 x 0.04 in) 30 x 30 x 1 mm (1.18 x 1.18 x 0.04 in) 54 x 54 x 1 mm (2.13 x 2.13 x 0.04 in) Differential travel 10% max. of effective detecting distance Control output p AC solid state Type SCR-NO (E2E-XjjjY1-jj-jj) SCR-NC (E2E-XjjjY2-jj-jj) Max. load 300 mA Min. load 5 mA Max. offstate leakage current 1.5 mA (See "Leakage Current Characteristics" graph in Engineering Data.) Max. on-state voltage drop (See "Leakage Current Characteristics" graph in Engineering Data.) Response frequency 25 Hz Circuit protection Output short-circuit Provided Weld field immunity Not provided RFI immunity Not provided Indicators Materials Target present (red LED) Housing Nickel-plated brass Sensing face Plastic Cable sheath Plastic Mounting Connections Two lock washers and M18 nuts included. Bracket Y92E-B18 optional. Prewired Weight with cable Enclosure ratings Approvals pp Two lock washers and M30 nuts included. Bracket Y92E-B30 optional. 2-conductor cable, 2 m (6.56 ft) length Approx. 160 g (5.6 oz.) Approx. 270 g (9.5 oz.) UL 1 NEMA 1, 4, 6, 12, 13 IEC 144 IP67 UL Recognized, File Number E76675 CSA Certified, File Number LR45951 Ambient operating temperature -25 to 70C (-13 to 158F) Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude Shock Approx. 100 G's 5 E2E 2-WIRE AC E2E 2-WIRE AC Operation J OUTPUT CIRCUITS Sensors without Short-Circuit Protection (E2E-XjYj) AC 2-wire Models E2E -XjYj AC 2 -wire Models E2E-XjYj Brown 1 (or 3) Load Sensing object Main circuit Red indicator Yes No Lit Not lit Control output Blue 2 (or 4) ON OFF Sensors with Short-Circuit Protection (E2E-XjYj-US-53) White (Brown) Load Prox. switch main circuit Black (Blue) Note: IEC colors are shown in parenthesis With Short-Circuit Protection E2E-XjY1-53 NO E2E-XjY2-53 NC Load Shorted Normal Shorted Normal Target Present Absent Present Absent Output ON OFF ON OFF Output operation indicator ON OFF ON OFF Short-Circuit Indication The LED dims when the load is shorted and the load output immediately turns off and remains off until the short-circuit protection is reset. Resetting Short-Circuit Protection Before the short-circuit protection can be reset, the short must be repaired. We recommend turning the power off before repairing the short. If this approach is taken, no further action is required to reset the short-circuit protection. If the short must be repaired with power on, the following resetting steps are required: For NO sensors, the target must be removed to reset the short-circuit protection. For NC sensors, the target must be presented then removed to reset the short-circuit protection. 6 E2E 2-WIRE AC E2E 2-WIRE AC Engineering Data J OPERATING RANGE (TYPICAL) Shielded Models Sensing distance X (mm) Sensing distance X (mm) E2E -XjYj E2Ej--X10j E2Ej-X2j E2Ej-X1R5j E2Ej--X5j Y (mm) Y (mm) Unshielded Models Sensing distance X (mm) Sensing distance X (mm) E2E -XjMYj E2Ej-X5Mj E2Ej-X18Mj E2Ej-X10Mj E2Ej-X2Mj Y (mm) Y (mm) J LEAKAGE CURRENT (TYPICAL) E2E-XjYj-53-US Proximity Sensor (when OFF) Leakage current (mA) Leakage current (mA) E2E -XjYj Protective resistance AC power supply Supply voltage (V) Supply voltage (V) 7 E2E 2-WIRE AC E2E 2-WIRE AC J RESIDUAL OUTPUT VOLTAGE (TYPICAL) E2E -XjYj Residual output voltage Proximity Sensor 24 VAC Residual load voltage Proximity Sensor 100 VAC Residual load voltage Load current (mA) Residual load voltage (V) Residual output voltage Residual load voltage (V) Residual load voltage (V) Residual output voltage Proximity Sensor 200 VAC Residual load voltage Load current (mA) Load current (mA) J SENSING DISTANCE VS. SENSING OBJECT (TYPICAL) E2E-X2Yj E2E -X1R5Yj E2E-X5Yj t = 1 mm Stainless steel (SUS304) Brass Aluminum Side length of target d (mm) Stainless steel (SUS304) t = 1 mm Brass Aluminum Side length of target d (mm) E2E -X10Yj Mild steel Sensing distance (mm) Mild steel Mild steel Sensing distance (mm) Sensing distance (mm) t = 1 mm Stainless steel (SUS304) Brass Aluminum Side length of target d (mm) E2E-X2MYj E2E-X5MYj t = 1 mm Brass t = 1 mm Aluminum Side length of target d (mm) Stainless steel (SUS304) Brass t = 1 mm Copper Aluminum Side length of target d (mm) 8 Sensing distance (mm) Stainless steel (SUS304) Mild steel Sensing distance (mm) Sensing distance (mm) Mild steel Mild steel Stainless steel (SUS304) Brass Aluminum Side length of target d (mm) E2E 2-WIRE AC E2E 2-WIRE AC J SENSING DISTANCE VS. SENSING OBJECT (TYPICAL) -- CONTINUED E2E -X10MY E2E-X18MYj t = 1 mm Stainless steel (SUS304) Brass t = 1 mm Mild steel Sensing distance (mm) Sensing distance (mm) Mild steel Aluminum Stainless steel (SUS304) Brass Aluminum Side length of target d (mm) Side length of target d (mm) Models with Short Circuit Protection (E2E-XjYj-53-US) Size of target d [mm (inch)] E2E-X18Mjj E2E-X10MIron Size of target d [mm (inch)] 9 Sensing distance X [mm (inch)] E2E-X10Mjj Sensing distance X [mm (inch)] Sensing distance X [mm (inch)] E2E-X5jj, E2E-X10jj Size of target d [mm (inch)] E2E 2-WIRE AC E2E 2-WIRE AC Dimensions J DRAWING LOCATOR Type Prewired without short-circuit protection Shielded Unshielded Prewired with short-circuit protection 4-pin p connector (M12) Shielded Unshielded Shielded Unshielded 3-pin p MicroChange g connector (M12) Shielded Unshielded Part number Figure number M8 E2E-X1R5Yj 1 M12 E2E-X2Yj 3 M18 E2E-X5Yj 5 M30 E2E-X10Yj 7 M8 E2E-X2MYj 2 M12 E2E-X5MYj 4 M18 E2E-X10MYj 6 M30 E2E-X18MYj 8 M18 E2E-X5Yj-53-US 9 M30 E2E-X10Yj-53-US 11 M18 E2E-X10MYj-53-US 10 M30 E2E-X18MYj-53-US 12 M12 E2E-X2Y-j-M1 13 M18 E2E-X5Y1-M1 15 M30 E2E-X10Y-j-M1 17 M12 E2E-X5MY-j-M1 14 M18 E2E-X10MY-j-M1 16 M30 E2E-X18MY-j-M1 18 M12 E2E-X2Y-j-M4 13 M18 E2E-X5Y-j-M4 15 M30 E2E-X10Y-j-M4 17 M12 E2E-X5MY-j-M4 14 M18 E2E-X10MY-j-M4 16 M30 E2E-X18MY-j-M4 18 10 E2E 2-WIRE AC E2E 2-WIRE AC Unit: mm (inch) Prewired Models (Shielded) Fig.1: Prewired Models (Unshielded) E2E -X1R5Yj Fig. 2: 40 (1.57) 15 dia. (0.59) E2E-X2MYj 40 (1.57) 15 dia. (0.59) 36 (1.42) 36 (1.42) 6 (0.24) Operation indicator M8 x 1 Two clamping nut Toothed washer Fig. 3: 21 dia. (0.83) Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 2 cores Standard length: 2 m E2E -X2Yj Fig. 4: 43 (1.69) 7 (0.28) Fig. 6: 43 (1.69) 38 (1.50) 14.8 dia. M18 x 1 Round vinyl-insulated cable 6 dia. (0.12 dia. x 45), 2/3 cores 6 dia. (0.08 dia. x 6/17) robotics cable models Standard length: 2m Operation indicator Two clamping nut Toothed washer Fig. 8: 48 (1.89) 43 (1.69) 42 dia. (1.65) Operation indicator Two clamping Round vinyl-insulated cable nut 4 dia. (0.08 dia. x 60), Toothed washer 2 cores Standard length: 2 m M12 x 1 43 (1.69) 10 (0.39) E2E -X10Yj 43 (1.69) 38 (1.50) E2E-X10MYj 29 dia. (1.14) 38 (1.50) Operation indicator Two clamping nut Toothed washer Fig. 7: 9 dia. E2E -X5Yj M18 x 1 E2E-X5MYj 21 dia. (0.83) 38 (1.50) 29 dia. (1.14) Standard length: 2 m Toothed washer Operation indicator M12 x 1 Two clamping nut Round vinyl-insulated cable Toothed washer 4 dia. (0.08 dia. x 60), 2 cores Standard length: 2 m Fig. 5: Operation indicator Two clamping Round vinyl-insulated cable nut 4 dia. (0.08 dia. x 60), 2 cores 6.1 dia. M8 x 1 Round vinyl-insulated Cable 6 dia. (0.12 dia. x 45), 2/3 cores 6 dia. (0.08 dia. x 6/17) robotics cable models Standard length: 2m E2E-X18MYj 42 dia. (1.65) 48 (1.89) 43 (1.69) 13 (0.51) Operation indicator Round vinyl-insulated Two clamping nut Cable 6 dia. (0.12 dia. Toothed washer x 45), 2/3 cores 6 dia. (0.08 dia. x 6/17) robotics cable models Standard length: 2m M30 x 1.5 11 26.8 dia. M30 x 1.5 Operation indicator Two clamping Toothed washer nut Round vinyl-insulated Cable 6 dia. (0.12 dia. x 45), 2/3 cores 6 dia. (0.08 dia. x 6/17) robotics cable models Standard length: 2m E2E 2-WIRE AC E2E 2-WIRE AC J PRE-WIRED MODELS WITH SHORT-CIRCUIT PROTECTION Shielded Unshielded Fig. 9: E2E-X5Yj-53-US 24 (0.945) across flats M18 4 (0.16) P=1.0 18.5 dia. (0.728) Cable: 6 (0.24) dia. 2 m (6.56 ft) 40 (1.57) 47 (1.85) M18 P=1.0 Fig. 12 5 (0.20) M30 P=1.5 (0.06) E2E-X18MYj-53-US 36 (1.417) across flats Indicator Indicator 30.5 dia (1.201) Cable: 6 (0.24) dia. 2 m (6.56 ft) 38 (1.50) 38 (1.50) 50 (1.97) 57 (2.24) 57 (2.24) Connector Models (Shielded) Connector Models (Unshielded) E2E -X2Y1-M1 53 (2.09) 38 (1.50) Fig. 14: E2E-X5MYj-M1 21 dia. (0.83) 7 (0.28) M12 x 1 Operation indicator M12 x 1 53 (2.09) 38 (1.50) M12 x 1 9 dia. Operation indicator M12 x 1 Two clamping nut Toothed washer Fig. 15: E2E-X5Y1-M1 Fig. 16: 53 (2.09) 38 (1.50) 29 dia. (1.14) 53 (2.09) 10 (0.39) Operation indicator Two clamping nut Toothed washer E2E-X10MYj-M1 29 dia. (1.14) M12 x 1 M18 x 1 Cable: 6 (0.24) dia. 2 m (6.56 ft) 13 (0.51) 50 (1.97) 21 dia. (0.83) Cable: 6 (0.24) dia. 2 m (6.56 ft) 10 (0.39) 29 (1.14) 40 (1.57) 47 (1.85) 30.5 dia (1.201) Fig. 13: Indicator 18.5 dia. (0.728) E2E-X10Yj-53-US 36 (1.417) across flats E2E-X10MYj-53-US 24 (0.945) across flats Indicator 29 (1.14) Fig. 11: Fig.10: 38 (1.50 ) M12 x 1 Operation indicator 14.8 dia. Two clamping nut Toothed washer M18 x 1 12 Two clamping nut Toothed washer E2E 2-WIRE AC E2E 2-WIRE AC Connector Models (Shielded), continued Fig.17: Connector Models (Unshielded), continued E2E -X10Y1-M1 Fig. 18: 58 (2.28) 43 (1.69) 42 dia. (1.65) E2E-X18MYj-M1 58 (2.28) 42 dia. (1.65) 13 (0.51) 43 (1.69) M12 x 1 M30 x 1.5 M12 x 1 26.8 dia. Operation indicator Two clamping nut Operation indicator M30 x 1.5 Toothed washer Two clamping nut Toothed washer J MOUNTING HOLES F Dimensions M8 M12 M18 M30 F (mm) 8.5+0.5/0 dia. 12.5+0.5/0 dia. 18.5+0.5/0 dia. 30.5+0.5/0 dia. Installation J PIN ARRANGEMENT E2E-XjYj-M1 AC 2-wire Models Output configuration Applicable models NO E2E-XjY1-M1 Pin arrangement Load Load Note: NC E2E-XjY2-M1 Terminals 1 and 2 are not used. Load Load Note: NO, NC Terminals 3 and 4 are not used. E2E-XjYj-M4 13 E2E 2-WIRE AC E2E 2-WIRE AC Precautions J MOUNTING Do not tighten the nut with excessive force. A washer must be used with the nut. M8 Shielded Model Unshielded Model Part B Part A Note: Part A Type yp Part B Length Torque Torque Shielded 9 mm Unshielded 3 mm 9NSm (90 kgf S cm) 12 N S m (120 kgf S cm) M12 30 N S m (310 kgf S cm) M18 70 N S m (710 kgf S cm) M30 180 N S m (1,800 kgf S cm) Part B Part A The table above right shows the tightening torques for part A and part B nuts. In the previous examples, the nut is on the sensor head side (part B) and hence the tightening torque for part B applies. If this nut is in part A, the tightening torque for part A applies instead. J EFFECTS OF SURROUNDING METAL When mounting the E2E within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the sensor. d dia. Type E2E-XjYj j j AC 2-wire Shielded Unshielded Dimension M8 M12 M18 M30 0 mm 0 mm 0 mm 0 mm d 8 mm 12 mm 18 mm 30 mm D 0 mm 0 mm 0 mm 0 mm m 4.5 mm 8 mm 20 mm 40 mm n 12 mm 18 mm 27 mm 45 mm 6 mm 15 mm 22 mm 30 mm d 24 mm 40 mm 55 mm 90 mm D 6 mm 15 mm 22 mm 30 mm m 8 mm 20 mm 40 mm 70 mm n 24 mm 36 mm 54 mm 90 mm 14 E2E 2-WIRE AC E2E 2-WIRE AC J MUTUAL INTERFERENCE When installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. B A Type E2E-XjYj j j AC 2-wire Shielded Unshielded Dimension M8 M12 M18 M30 A 20 mm 30 (20) mm 50 (30) mm 100 (50) mm B 15 mm 20 (12) mm 35 (18) mm 70 (35) mm A 80 mm 120 (60) mm 200 (100) mm 300 (100) mm B 60 mm 100 (50) mm 110 (60) mm 200 (100) mm Note: The figures in parentheses refer to Sensors operating at different frequencies. Cable Tractive Force Do not pull cable with the tractive forces exceeding the following. J INSTALLATION Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Power OFF The Proximity Sensor may output a pulse signal when it is turned off. Therefore, it is recommended to turn off the load before turning off the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Sensing Target Metal Coating: The sensing distances of the Proximity Sensor vary with the metal coating on sensing targets. J WIRING High-tension Lines Wiring through Metal Conduit If there is a power or high-tension line near the cord of the Proximity Sensor, wire the cord through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. 15 Diameter Tractive force 4 mm dia. max. 30 N max. 4 mm dia. min. 50 N max. J MOUNTING The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, or the Proximity Sensor may be damaged or lose its water-resistance. J ENVIRONMENT Water Resistance Do not use the Proximity Sensor underwater, outdoors, or in the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors to maintain its reliability and life expectancy. Although the Proximity Sensor is water resistant, a cover to protect the Proximity Sensor from water or water soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). E2E 2-WIRE AC E2E 2-WIRE AC J CONNECTING LOAD TO AC 2-WIRE SENSOR Refer to the following before using AC or DC 2-wire Proximity Sensors. Surge Protection Although the Proximity Sensor has a surge absorption circuit, if there is any machine that has a large surge current (e.g., a motor or welding machine) near the Proximity Sensor, connect a surge absorber to the machine. Leakage Current When it is OFF, the Proximity Sensor has leakage current. Refer to Leakage Current Characteristics. In this case, the load is imposed with a small voltage and the load may not be reset. Before using the Proximity Sensor, make sure that this voltage is less than the load reset voltage. The AC 2-wire Proximity Sensor cannot be connected to any card-lift-off relay (e.g., the G2A) because contact vibration of the relay will be caused by the leakage current and the life of the relay will be shortened. Countermeasures Against Leakage Current AC 2-wire Models Connect a bleeder resistor as the bypass for the leakage current so that the current flowing into the load will be less than the load reset current. As shown in the following diagram, connect the bleeder resistor so that the current flowing into the Proximity Sensor will be 10 mA minimum and the residual voltage imposed on the load will be less than the load reset voltage. Load Bleeder resistor R VAC power supply VS Refer to the following to calculate the bleeder resistance and the allowable power of the bleeder resistor. R VS/(10 -- I) (k) P > VS2/R (mW) P: The allowable power of the bleeder resistor. (The actual power capacity of the bleeder resistor must be at least a few times as large as the allowable power of the bleeder resistor.) I: Load current (mA) The following resistors are recommended. 100 VAC (supply voltage): A resistor with a resistance of 10 k maximum and an allowable power of 3 W minimum 200 VAC (supply voltage): A resistor with a resistance of 20 k maximum and an allowable power of 10 W minimum If these resistors generate excessive heat, use a resistor with a resistance of 10 k maximum and an allowable power of 5 W minimum at 100 VAC and a resistor with a resistance of 20 k maximum and an allowable power of 10 W minimum at 200 VAC instead. J PRECAUTIONS FOR AC 2-WIRE PROXIMITY SENSORS IN OPERATION Connector Model Connection type AC 2-wire AND (serial connection) Method Description If 100 or 200 VAC is imposed on the Proximity Sensors, VL (i.e., the voltage imposed on the load) will be obtained from the following. Incorrect Load VL = VS -- (residual voltage x no. of Proximity Sensors) (V) Therefore, if VL is lower than the load operating voltage, the load will not operate. Correct Load A maximum of three Proximity Sensors can be connected in series provided that the supply voltage is 100 V minimum. Load Vs 100 V 16 E2E 2-WIRE AC E2E 2-WIRE AC J PRECAUTIONS FOR AC 2-WIRE PROXIMITY SENSORS IN OPERATION, CONTINUED Model Connection type AC 2-wire OR (parallel connection) Method Description In principle, more than two Proximity Sensors cannot be connected in parallel. Incorrect A Load B Provided that Proximity Sensor A does not operate with Proximity Sensor B simultaneously and there is no need to keep the load operating continuously, the Proximity Sensors can be connected in parallel. In this case, however, due to the total leakage current of the Proximity Sensors, the load may not reset properly. Correct A Load B VAC power supply VS It is not possible to keep the load operating continuously with Proximity Sensors A and B in simultaneous operation to sense sensing objects due to the following reason. When Proximity Sensor A is ON, the voltage imposed on Proximity Sensor A will drop to approximately 10 V and the load current flows into Proximity Sensor A, and when one of the sensing objects is close to Proximity Sensor B, Proximity Sensor B will not operate because the voltage imposed on Proximity Sensor B is 10 V, which is too low. When Proximity Sensor A is OFF, the voltage imposed on Proximity Sensor B will reach the supply voltage and Proximity Sensor B will be ON. Then, Proximity Sensor A as well as Proximity Sensor B will be OFF for approximately 10 ms, which resets the load for an instant. To prevent the instantaneous resetting of the load, use a relay as shown on the left. NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMRON ELECTRONICS LLC OMRON ON--LINE OMRON CANADA, INC. 1-800-55-OMRON Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci 416-286-6465 One East Commerce Drive Schaumburg, IL 60173 Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. 885 Milner Avenue Scarborough, Ontario M1B 5V8 Printed in U.S.A.