1-phase filters
FN 2450
Safe and ergonomic EMC/EMI filter with
very low leakage current
Approvalsn Light weight plastic enclosure design
n Very low filter leakage current
n Hinged safety covers
n Embedded filter terminals
n Different performance levels
n Environmental friendly design without
potting compound
Typical applications
n A plastic housing and a metal ground plate
are cleverly combined to get the lowest
possible product weight without compro-
mising EMC behavior.
n The embedded terminals from Schaffner
guarantee user-friendly handling and reli-
able, long-lasting electrical connection.
n Captive hinged protective covers contri-
bute to overall safety by offering protection
against unintended contact with life con-
ductors. They are included in the standard
scope of delivery without any extra cost.
n Very low leakage current values make
the filters suitable for grids with very
tough requirements or sensitive GFCIs,
and for applications which set value on
safety and reliability.
n FN 2450 feature an ecologically conscious
construction without the use of potting
compound or banned substances (RoHS).
Used raw materials can be easily separated
at the end of the product life time for pro-
per and environmentally safe disposal.
n Electrical and electronic equipment
n Test and measurement devices
n Medical devices
n Industrial automation
n Small machines
n Office automation equipment
Features and benefits
Technical specifications
Maximum continuous operating voltage: 250VAC, 50/60Hz
Operating frequency: dc to 400Hz
Rated currents: 6 to 20A @ 55°C
High potential test voltage: P/N –> E 2500VAC for 60 sec*
P –> N 1100VDC for 2 sec
Temperature range (operation and storage): -25°C to +100°C (25/100/21)
Flammability corresponding to: UL 94V-0 (safety covers UL 94V-1)
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986,
IEC/EN 60939, EN 60601-1
MTBF @ 40°C/230V (Mil-HB-217F): >180,000 hours
Typical electrical schematic
P
N
PE
Line
Cx-1 R L Cy
P‘
N‘
Load
Cx-2
Cy
* Type testing only
> Components > FN 2450
Per CISPR 17; A = 50Ω/50Ω sym; B = 50Ω/50Ω asym
Typical filter attenuation (FN 2450F)
6A types 10A types 16A types 20A types
* The letter following FN 2450_ represents the value of the Y-capacitor and is directly related to the performance and leakage current of the filter. Other Y-capacitor values are available upon request.
** Maximum leakage current under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
Filter* Rated current Leakage Inductance Capacitance Resistance Input/Output Weight
@ 55°C (40°C) current** L Cx Cy R connections
@ 230VAC/50Hz
[A] [mA] [mH] [μF] [nF] [MΩ] [g]
Filter selection table
FN 2450G-6-61 6 (6.8) 0.73 10.5 0.47 4.7 1 -61 210
FN 2450G-10-61 10 (11.4) 0.73 4.9 0.47 4.7 1 -61 210
FN 2450G-16-61 16 (18.2) 0.73 1.84 0.47 4.7 1 -61 210
FN 2450G-20-61 20 (22.8) 0.73 0.94 0.47 4.7 1 -61 210
FN 2450F-6-61 6 (6.8) 0.52 10.5 0.47 3.3 1 -61 210
FN 2450F-10-61 10 (11.4) 0.52 4.9 0.47 3.3 1 -61 210
FN 2450F-16-61 16 (18.2) 0.52 1.84 0.47 3.3 1 -61 210
FN 2450F-20-61 20 (22.8) 0.52 0.94 0.47 3.3 1 -61 210
FN 2450B-6-61 6 (6.8) 0.002 10.5 0.47 1 -61 210
FN 2450B-10-61 10 (11.4) 0.002 4.9 0.47 1 -61 210
FN 2450B-16-61 16 (18.2) 0.002 1.84 0.47 1 -61 210
FN 2450B-20-61 20 (22.8) 0.002 0.94 0.47 1 -61 210
FN 2450 are delivered with closed plastic
covers and fastened terminals. To install the
filter please proceed as follows:
n Mount the filter on a metal surface with
two appropriate bolts.
n First connect the green/yellow wire to the
earth stud of the filter.
n Gently lift the two hinged plastic covers.
n Untighten the terminals with an appro-
priately sized screw driver.
n Connect phase and neutral wires with
cable lugs by pushing down and tightening
the bolts.
n Please note the torque recommendation on
the next page.
n Push the safety covers back into their
locked position to finish the filter installaton.
Installation
> Components > FN 2450
Your local partner: To find your local partner within Schaffner’s global network, please go to www.schaffner.com June 2009
Mechanical data
-61 (6A) -61 (10A) -61 (16A) -61 (20A)
Filter input/output connector cross sections
Flex wire 1.3 - 2.5mm2 1.3 - 2.5mm2 4 - 6mm2 4 - 6mm2
AWG type wire AWG 13 - AWG 16 AWG 13 - AWG 16 AWG 12 - AWG 10 AWG 12 - AWG 10
Ring/fork lug (W/d)* max. 11mm/min. Ø4.3mm max. 11mm/min. Ø4.3mm max. 11mm/min. Ø4.3mm max. 11mm/min. Ø4.3mm
Recommended torque 0.8 - 1Nm 0.8 - 1Nm 0.8 - 1Nm 0.8 - 1Nm
* Schaffner recommends the use of insulated and UL-recognized ring lugs or fork lugs of the appropriate size.
Please visit www.schaffner.com to find more details on filter connectors.
51 ±0.4
38 ±0.4
30.7
10 8.5
93 ±0.4
103 ±0.4
75 ±0.4
11.713
4x M4 screw
Earth connection:
M4 screw
2x Ø4.4
W W