1-phase filters FN 2450 Safe and ergonomic EMC/EMI filter with very low leakage current n n n n n n Light weight plastic enclosure design Very low filter leakage current Hinged safety covers Embedded filter terminals Different performance levels Environmental friendly design without potting compound Technical specifications Maximum continuous operating voltage: Operating frequency: Rated currents: High potential test voltage: Temperature range (operation and storage): Flammability corresponding to: Design corresponding to: MTBF @ 40C/230V (Mil-HB-217F): Approvals Typical electrical schematic 250VAC, 50/60Hz dc to 400Hz 6 to 20A @ 55C P/N -> E 2500VAC for 60 sec* P -> N 1100VDC for 2 sec -25C to +100C (25/100/21) UL 94V-0 (safety covers UL 94V-1) UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939, EN 60601-1 >180,000 hours Cx-1 R L Cx-2 Cy P P` N N` PE Cy Line * Type testing only Features and benefits n n A plastic housing and a metal ground plate Very low leakage current values make n Electrical and electronic equipment are cleverly combined to get the lowest the filters suitable for grids with very n Test and measurement devices possible product weight without compro- tough requirements or sensitive GFCIs, n Medical devices mising EMC behavior. and for applications which set value on n Industrial automation safety and reliability. n Small machines FN 2450 feature an ecologically conscious n Office automation equipment n The embedded terminals from Schaffner guarantee user-friendly handling and reli- n Typical applications n able, long-lasting electrical connection. construction without the use of potting Captive hinged protective covers contri- compound or banned substances (RoHS). bute to overall safety by offering protection Used raw materials can be easily separated against unintended contact with life con- at the end of the product life time for pro- ductors. They are included in the standard per and environmentally safe disposal. scope of delivery without any extra cost. Load > Components > FN 2450 Filter selection table Filter* Rated current Leakage Inductance Capacitance Resistance Input/Output @ 55C (40C) current** L Cx Cy R connections @ 230VAC/50Hz [A] [mA] [mH] [F] [nF] [M] FN 2450G-6-61 6 (6.8) 0.73 10.5 0.47 4.7 1 -61 FN 2450G-10-61 10 (11.4) 0.73 4.9 0.47 4.7 1 -61 FN 2450G-16-61 16 (18.2) 0.73 1.84 0.47 4.7 1 -61 FN 2450G-20-61 20 (22.8) 0.73 0.94 0.47 4.7 1 -61 FN 2450F-6-61 6 (6.8) 0.52 10.5 0.47 3.3 1 -61 FN 2450F-10-61 10 (11.4) 0.52 4.9 0.47 3.3 1 -61 FN 2450F-16-61 16 (18.2) 0.52 1.84 0.47 3.3 1 -61 FN 2450F-20-61 20 (22.8) 0.52 0.94 0.47 3.3 1 -61 FN 2450B-6-61 6 (6.8) 0.002 10.5 0.47 1 -61 FN 2450B-10-61 10 (11.4) 0.002 4.9 0.47 1 -61 FN 2450B-16-61 16 (18.2) 0.002 1.84 0.47 1 -61 FN 2450B-20-61 20 (22.8) 0.002 0.94 0.47 1 -61 Weight [g] 210 210 210 210 210 210 210 210 210 210 210 210 * The letter following FN 2450_ represents the value of the Y-capacitor and is directly related to the performance and leakage current of the filter. Other Y-capacitor values are available upon request. ** Maximum leakage current under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Typical filter attenuation (FN 2450F) Per CISPR 17; A = 50/50 sym; B = 50/50 asym 6A types 10A types 16A types 20A types Installation FN 2450 are delivered with closed plastic covers and fastened terminals. To install the filter please proceed as follows: n Mount the filter on a metal surface with two appropriate bolts. n First connect the green/yellow wire to the earth stud of the filter. n Gently lift the two hinged plastic covers. n Untighten the terminals with an appropriately sized screw driver. n Connect phase and neutral wires with cable lugs by pushing down and tightening the bolts. n Please note the torque recommendation on the next page. n Push the safety covers back into their locked position to finish the filter installaton. > Components > FN 2450 Mechanical data 13 8.5 4x M4 screw 38 0.4 Earth connection: M4 screw 11.7 93 0.4 30.7 10 51 0.4 103 0.4 2x O4.4 75 0.4 Filter input/output connector cross sections Flex wire AWG type wire Ring/fork lug (W/d)* Recommended torque * -61 (6A) -61 (10A) -61 (16A) -61 (20A) 1.3 - 2.5mm2 AWG 13 - AWG 16 max. 11mm/min. O4.3mm 0.8 - 1Nm 1.3 - 2.5mm2 AWG 13 - AWG 16 max. 11mm/min. O4.3mm 0.8 - 1Nm 4 - 6mm2 AWG 12 - AWG 10 max. 11mm/min. O4.3mm 0.8 - 1Nm 4 - 6mm2 AWG 12 - AWG 10 max. 11mm/min. O4.3mm 0.8 - 1Nm Schaffner recommends the use of insulated and UL-recognized ring lugs or fork lugs of the appropriate size. Please visit www.schaffner.com to find more details on filter connectors. W W d d Your local partner: To find your local partner within Schaffner's global network, please go to www.schaffner.com June 2009