Frequency [MHz] Nom. Insertion Loss
1 MHz 0.29 dB/100ft
3 MHz 0.58 dB/100ft
5 MHz 0.7 dB/100ft
8 MHz 0.87 dB/100ft
10 MHz 1.05 dB/100ft
50 MHz 1.8 dB/100ft
100 MHz 2.7 dB/100ft
200 MHz 3.9 dB/100ft
400 MHz 5.9 dB/100ft
700 MHz 8.5 dB/100ft
900 MHz 10 dB/100ft
1000 MHz 10.7 dB/100ft
Delay
Max. Delay Skew Nominal Delay Nominal Velocity of Propagation (VP) [%]
84 ns/100m 1.21 ns/ft 84 %
Voltage
UL Voltage Rating
300 V RMS
Temperature Range
UL Temp Rating: 75°C
Operating Temp Range: -20°C To +75°C
Mechanical Characteristics
Bulk Cable Weight: 30 lbs/1000ft
Max Recommended Pulling Tension: 52 lbs
Min Bend Radius/Minor Axis: 1.75 in
Standards
NEC Articles: 800
NEC/(UL) Specification: CMP
CEC/C(UL) Specification: CMP
CPR Euroclass: Eca
RG Type: 59/U Type
Series Type: Series 59
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (ROHS II): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU: Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes
EU RoHS Compliance Date (yyyy-mm-dd): 2005-04-01
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Suitability
Suitability - Indoor: Yes
Flammability, LS0H, Toxicity Testing
C(UL) Flammability: FT6
UL Flammability: NFPA 262 Plenum Flame Test (UL910)
UL voltage rating: 300 V RMS
Plenum/Non-Plenum