9002
OUTPUT SPECIFICATIONS
MODEL NUMBERS
D1D07 D1D12 D1D20 D1D40 D2D07 D2D12 D4D07 D4D12 D5D07 D5D10
Operating Voltage Range [Vdc] 0-100 0-100 0-100 0-100 0-200 0-200 0-400 0-400 0-500 0-500
Max. Load Current [Adc] 7 122040 7 12 7 12 7 10
Min. Load Current [mA] 20 20 20 20 20 20 20 20 20 20
Max. Surge Current, [Adc] (10Msec) 15 28 42 106 22 27 17 36 19 29
Max. On-State Voltage Drop @ Rated Current [Vdc] 2.0 1.6 2.1 2.1 2.0 2.8 4.2 4.2 5.7 5.5
Thermal Resistance Junction to Case [RθJC] °C/W 2.2 1.34 1.06 0.83 1.5 1.06 1.06 0.8 1.0 0.8
Max On-state Resistance @ Rated Current (RDS-ON) [Ohms]
.29 .13 .10 .05 .29 .23 .6 .35 .8 .55
Max. Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.2 0.3 0.3 0.1 0.3 0.3 0.3 0.2 0.3
Max. Turn-On Time [µsec] 100 100 100 100 100 100 100 100 100 100
Max. Turn-Off Time [msec] 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
INPUT SPECIFICATIONS DC CONTROL
Control Voltage Range 3.5-32 Vdc
Maximum Turn-On Voltage 3.5 Vdc
Minimum Turn-Off Voltage 1.0 Vdc
Nominal Input Impedance See Note 4
Maximum Input Current 1.6 mA (5 Vdc), 28 mA (32 Vdc)
GENERAL NOTES
All parameters at 25ºC unless otherwise specified.
Dielectric strength and insulation resistance are measured between input and output.
Heat sinking required, for derating curves see page 3.
Input circuitry incorporates active current limiter.
MOSFET Output
Low On-State Resistance
Paralleling Capability for
Higher Currents
Panel Mount
FastFax Document No. 164
SERIES 1DC.032698, PAGE 1 OF 3
DC output relays feature MOSFET tech-
nology for low on-state resistance,
assuring easy paralleling and switching
capabilities to 40 amps at 100 Vdc.
Lower current models are also available
to 500 Vdc. All models come in
Crydom's standard panel-mount package.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
Series 1-DC
7-40Amp • 0-500 Vdc • DC Output
©1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: (800) 8 CRYDOM (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
GENERAL SPECIFICATIONS
Dielectric Strength 60Hz 2500 Vrms
Insulation Resistance (Min.) @ 500 Vdc 109Ohm
Max. Capacitance Input/Output 50 pF
Ambient Operating Temperature Range -30 to 80ºC
Ambient Storage Temperature Range -40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical) 3.0 oz. (86.5g)
Encapsulation: Thermally Conductive Epoxy
Terminals: Screws and Saddle Clamps Furnished, Unmounted
All dimensions are in inches (millimeters)
APPROVALS
UL E116950 (100 Volt Models Only)
1.87
(47.5)
.78
(19.8)
2.30
(58.4)
1.70
(43.2)
.90
(22.9)
.45
(11.4)
1.10
(27.9)
8-32 TERMINAL
(2 PLACES )
1.00
(25.4) 6-32 TERMINAL
(2 PLACES)
1.80
(45.7)
SOLID-STATE RELAY
OUTPUT
+
--
+--
INPUT
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1 2
34
MAXIMUM SURGE vs. DURATION
2 3 4 5 6 8 10 2 3 4 5 681022 3 4 5 681032 3 4 5 68104
5
10
15
20
25
30
35
40
45
50
55
60
D5D07
D5D10
D4D12
D4D07
2 3 4 5 6 8 10 2 3 4 5 6 81022 3 4 5 6 81032 3 4 5 6 8104
50
100
150
200
D1D40
SURGE DURATION (msec)
SURGE DURATION (msec)
MAX. SURGE CURRENT (Amps)
2 3 4 5 68 10 2 3 4 5 681022 3 4 5 681032 3 4 5 6 8104
5
10
15
20
25
30
35
40
45
50
55
60 D1D20
D1D07 D2D07
D2D12
D1D12
SURGE DURATION (msec)
MAX. SURGE CURRENT (Amps)MAX. SURGE CURRENT (Amps)
DC
CONTROL
SOURCE SSR
INPUT
OUTPUT
4 (–) 1 (–)
3 (+) 2 (+)
(–)
(+)
LOAD
Input and output polarity must be observed.
Inductive loads must be diode suppressed.
Transient Protection
All loads are inductive, even ones that are not so labeled. An
inductive load will produce harmful transient voltages when it
is turned off. The more perfect the switch, the larger the tran-
sient voltages; the MOSFET output is so nearly an ideal switch
that the transient voltages produced by seemingly "non-induc-
tive" loads can cause damage if not suppressed. Diodes should
be fast recovery type with PIV rated greater than supply voltage.
Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and
10-32 Screws - 20in./lbs. (Screws dry without grease.)
9002
FastFax Document No. 164
SERIES 1DC.032698, PAGE 2 OF 3
Series 1-DC
7-40Amp • 0-500 Vdc • DC Output
For recommended applications and more information contact:
USA: (800) 8 CRYDOM (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
©1998 CRYDOM CORP, Specifications subject to change without notice.
Base Plate Temp [ºC]
D1D07 - 7A
Base Plate Temp [ºC]
24
16
8
20
12
4
02 4 108 126 20 40 60 80
Load Current [Adc] Max Ambient Temp. [ºC]
Power Dissipation
Base Plate Temp [ºC]
2 4 1086
D1D12 - 12A
16
12
8
4
020 40 60 80
Load Current [Adc] Max Ambient Temp. [ºC]
Power Dissipation
90
120
100
110
90
120
100
110
18
9
6
15
12
3
020 40 60 80
Load Current [Adc] Max Ambient Temp. [ºC]
Power Dissipation
95
120
100
110
45
30
15
04 8 16 2012 20 40 60 80
Load Current [Adc] Max Ambient Temp. [ºC]
Power Dissipation
100
110
120
Base Plate Temp [ºC]
D1D20 - 20A
80
90
90
60
30
08 16 32 4024 20 40 60 80
Load Current [Adc] Max Ambient Temp. [ºC]
Power Dissipation
Base Plate Temp [ºC]
D1D40 - 40A
120
80
100
140
D2D07 - 7A
40
20
10
30
012
2 4 1086 12
20 40 60 80
Load Current [Adc] Max Ambient Temp. [ºC]
Power Dissipation
Base Plate Temp [ºC]
D2D12 - 12A
40
10
30
10
30
20
03 41 2 6 75 20 40 60 80
Load Current [Adc] Max Ambient Temp. [ºC]
Power Dissipation
85
120
Base Plate Temp [ºC]
3 41 2 6 75
3 41 2 6 75
3 41 2 6 75
D4D07 - 7A
100
110
85
120
100
110
85
120
100
110
85
120
100
110
60
40
50
10
20
30
020 40 60 80
Load Current [Adc] Max Ambient Temp. [ºC]
Power Dissipation
Base Plate Temp [ºC]
D4D12 - 12A
40
20
020 40 60 80
Load Current [Adc] Max Ambient Temp. [ºC]
Power Dissipation
Base Plate Temp [ºC]
D5D07 - 7A
60
30
20
10
40
50
02 4 8 106 20 40 60 80
Load Current [Adc] Max Ambient Temp. [ºC]
Power Dissipation
90
105
120
Base Plate Temp [ºC]
D5D10 - 10A
75
6ºC/W
2ºC/W 1ºC/W
4ºC/W
NO HEATSINK
4ºC/W
1ºC/W
0.5ºC/W
2ºC/W
NO HEATSINK
6ºC/W
2ºC/W
4ºC/W
NO HEATSINK
4ºC/W
1ºC/W
0.5ºC/W
2ºC/W
NO HEATSINK
6ºC/W
2ºC/W
1ºC/W
4ºC/W
NO HEATSINK
6ºC/W
2ºC/W
1ºC/W
4ºC/W
NO HEATSINK
6ºC/W
2ºC/W
4ºC/W
NO HEATSINK
6ºC/W
2ºC/W
4ºC/W
NO HEATSINK
1ºC/W
6ºC/W
1ºC/W
4ºC/W
NO HEATSINK
2ºC/W
2ºC/W
NO HEATSINK
0.2ºC/W
0.5ºC/W
1.5ºC/W
CURRENT DERATING CURVES
Crydom Heat Sinks offer excellent
thermal management and are perfect-
ly matched to the load current ratings
of Crydom panel mount relays.
Request Crydom’s Heat Sink specifica-
tion sheet for all the details.
9002
FastFax Document No. 164
SERIES 1DC.032698, PAGE 3 OF 3
Series 1-DC
7-40Amp • 0-500 Vdc • DC Output
For recommended applications and more information contact:
USA: (800) 8 CRYDOM (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
©1998 CRYDOM CORP, Specifications subject to change without notice.