Series 1-DC 7-40Amp * 0-500 Vdc * DC Output * MOSFET Output * Low On-State Resistance * Paralleling Capability for Higher Currents * Panel Mount DC output relays feature MOSFET technology for low on-state resistance, assuring easy paralleling and switching capabilities to 40 amps at 100 Vdc. Lower current models are also available to 500 Vdc. All models come in Crydom's standard panel-mount package. Manufactured in Crydom's ISO 9002 Certified facility for optimum product performance and reliability. OUTPUT SPECIFICATIONS MODEL NUMBERS Operating Voltage Range [Vdc] Max. Load Current [Adc] D1D07 D1D12 D1D20 D1D40 D2D07 D2D12 D4D07 D4D12 D5D07 D5D10 0-100 0-200 0-200 0-400 0-400 0-500 0-500 0-100 0-100 0-100 7 12 20 40 7 12 7 12 7 10 Min. Load Current [mA] 20 20 20 20 20 20 20 20 20 20 Max. Surge Current, [Adc] (10Msec) 15 28 42 106 22 27 17 36 19 29 Max. On-State Voltage Drop @ Rated Current [Vdc] 2.0 1.6 2.1 2.1 2.0 2.8 4.2 4.2 5.7 5.5 Thermal Resistance Junction to Case [RJC] C/W 2.2 1.34 1.06 0.83 1.5 1.06 1.06 0.8 1.0 0.8 Max On-state Resistance @ Rated Current (RDS-ON) [Ohms] .29 .13 .10 .05 .29 .23 .6 .35 .8 .55 Max. Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.2 0.3 0.3 0.1 0.3 0.3 0.3 0.2 0.3 Max. Turn-On Time [sec] 100 100 100 100 100 100 100 100 100 100 Max. Turn-Off Time [msec] 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 INPUT SPECIFICATIONS DC CONTROL 3.5-32 Vdc Control Voltage Range Maximum Turn-On Voltage 3.5 Vdc Minimum Turn-Off Voltage 1.0 Vdc See Note 4 Nominal Input Impedance 1.6 mA (5 Vdc), 28 mA (32 Vdc) Maximum Input Current GENERAL NOTES (c)1998 CRYDOM CORP, Specifications subject to change without notice. All parameters at 25C unless otherwise specified. Dielectric strength and insulation resistance are measured between input and output. Heat sinking required, for derating curves see page 3. Input circuitry incorporates active current limiter. FastFax Document No. 164 SERIES 1DC.032698, PAGE 1 OF 3 For recommended applications and more information contact: USA: (800) 8 CRYDOM * (800) 827-9366 * (619) 715-7200 * fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 * e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 * fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 * fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany 9002 Series 1-DC 7-40Amp * 0-500 Vdc * DC Output GENERAL SPECIFICATIONS Dielectric Strength 60Hz 2500 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output 50 pF Ambient Operating Temperature Range -30 to 80C Ambient Storage Temperature Range -40 to 125C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Screws and Saddle Clamps Furnished, Unmounted MAXIMUM SURGE vs. DURATION 1.10 (27.9) .45 (11.4) 8-32 TERMINAL (2 PLACES ) 60 D1D20 -1.87 (47.5) + OUTPUT 1 2.30 (58.4) 1.70 (43.2) 2 SOLID-STATE RELAY 4 -- 3 INPUT MAX. SURGE CURRENT (Amps) 55 + 1.00 (25.4) 1.80 (45.7) 6-32 TERMINAL (2 PLACES) 50 45 40 D1D12 D2D12 35 30 25 20 15 D2D07 D1D07 10 5 .78 (19.8) .90 (22.9) 2 3 4 5 6 8 10 2 3 4 5 6 8102 2 3 4 5 6 8103 SURGE DURATION (msec) 2 3 4 5 6 8104 All dimensions are in inches (millimeters) 60 Input and output polarity must be observed. Inductive loads must be diode suppressed. 4 (-) 55 MAX. SURGE CURRENT (Amps) Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) 50 D4D12 45 40 35 D5D10 30 25 D4D07 20 D5D07 15 10 5 2 1 (-) 3 4 5 6 8 10 2 3 4 5 6 8102 2 3 4 5 6 8103 SURGE DURATION (msec) 2 3 4 5 6 8104 3 4 5 6 8 10 2 3 4 5 6 8102 2 3 4 5 6 8103 SURGE DURATION (msec) 2 3 4 5 6 8104 3 (+) 2 (+) (-) (+) Transient Protection All loads are inductive, even ones that are not so labeled. An inductive load will produce harmful transient voltages when it is turned off. The more perfect the switch, the larger the transient voltages; the MOSFET output is so nearly an ideal switch that the transient voltages produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should be fast recovery type with PIV rated greater than supply voltage. 200 MAX. SURGE CURRENT (Amps) SSR OUTPUT DC CONTROL SOURCE INPUT LOAD D1D40 150 100 50 2 (c)1998 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL E116950 (100 Volt Models Only) FastFax Document No. 164 SERIES 1DC.032698, PAGE 2 OF 3 For recommended applications and more information contact: USA: (800) 8 CRYDOM * (800) 827-9366 * (619) 715-7200 * fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 * e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 * fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 * fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany 9002 Series 1-DC 7-40Amp * 0-500 Vdc * DC Output Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details. CURRENT DERATING CURVES D1D07 - 7A D1D12 - 12A 20 100 16 4C/W 12 6C/W 8 NO HEATSINK 4 120 0 20 7 40 60 80 2 Max Ambient Temp. [C] 4 6 8 D1D40 - 40A 20 40 60 80 100 1.5C/W 2C/W 120 2C/W 100 4C/W 12 6C/W 9 140 0 16 24 32 40 20 40 60 110 6 NO HEATSINK 2 3 4 20 4C/W 110 6C/W 10 NO HEATSINK 120 3 4 5 6 7 20 40 60 80 40 60 30 D5D10 - 10A 80 2C/W 100 4C/W 20 110 6C/W 10 80 120 2 4 6 1C/W 100 30 4C/W 110 NO HEATSINK 120 20 2 4 6 8 10 12 20 10 12 8 Load Current [Adc] 20 40 60 80 Max Ambient Temp. [C] D5D07 - 7A 2C/W Load Current [Adc] Max Ambient Temp. [C] 40 60 80 Max Ambient Temp. [C] 40 85 1C/W 30 2C/W 20 4C/W 100 110 6C/W 10 120 NO HEATSINK 0 1 2 3 4 5 6 7 Load Current [Adc] 20 40 60 80 Max Ambient Temp. [C] (c)1998 CRYDOM CORP, Specifications subject to change without notice. 75 60 1C/W 90 40 2C/W 30 105 4C/W 20 10 120 NO HEATSINK 0 2 4 6 8 Load Current [Adc] 10 20 40 60 80 Max Ambient Temp. [C] FastFax Document No. 164 SERIES 1DC.032698, PAGE 3 OF 3 Base Plate Temp [C] 0.5C/W 50 Power Dissipation 20 40 0 60 NO HEATSINK 85 0.5C/W 10 0 40 85 Max Ambient Temp. [C] 50 Power Dissipation Power Dissipation 100 2 6 7 60 Base Plate Temp [C] 1C/W 20 Max Ambient Temp. [C] 1C/W D4D12 - 12A 30 Load Current [Adc] 5 Load Current [Adc] D4D07 - 7A 2C/W 20 0 1 85 16 120 Max Ambient Temp. [C] 40 1 12 40 0 80 120 D2D12 - 12A 3 NO HEATSINK Load Current [Adc] 8 Load Current [Adc] 95 15 Power Dissipation 1C/W Base Plate Temp [C] 60 8 4 Max Ambient Temp. [C] 18 80 0.2C/W 0.5C/W 110 6C/W D2D07 - 7A 90 30 10 12 Load Current [Adc] Power Dissipation 5 6 Power Dissipation 4 15 NO HEATSINK Base Plate Temp [C] 3 100 4C/W 0 Base Plate Temp [C] 2 Load Current [Adc] 90 2C/W 120 0 1 Power Dissipation 110 1C/W 30 Base Plate Temp [C] NO HEATSINK 4 2C/W Base Plate Temp [C] 110 80 45 Base Plate Temp [C] 6C/W 8 90 Power Dissipation 100 Power Dissipation 4C/W Base Plate Temp [C] Power Dissipation 2C/W 12 D1D20 - 20A 24 90 Base Plate Temp [C] 16 For recommended applications and more information contact: USA: (800) 8 CRYDOM * (800) 827-9366 * (619) 715-7200 * fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 * e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 * fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49)871 935405 * fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany 9002