1 2
MODEL DPG500 DPG750
AC INPUT[V] AC85 - 264 AC170 - 264 AC85 - 264 AC170 - 264
MAX OUTPUT WATTAGE[W]
*1
300 500 500 750
DC OUTPUT VOLTAGE[V]
*2
360
SPECIFICATIONS
MODEL DPG500 DPG750
INPUT
VOLTAGE[V] AC85 - 264 1fAC170 - 264 1fAC85 - 264 1fAC170 - 264 1f
POWER FACTOR CORRECTION RANGE[V]
AC85 - 264 1f
CURRENT[A] 3.47typ (ACIN 100V) 2.86typ (ACIN 200V) 5.72typ (ACIN 100V) 4.24typ (ACIN 200V)
FREQUENCY[Hz] 50/60 (47 - 63) Hz
INRUSH CURRENT[A] Limited by external resistance
EFFICIENCY[%] 92typ (ACIN 100V) 95typ (ACIN 200V) 93typ (ACIN 100V) 96typ (ACIN 200V)
POWER FACTOR 0.96typ (ACIN 100V) 0.93typ (ACIN 200V) 0.96typ (ACIN 100V) 0.93typ (ACIN 200V)
LEAKAGE CURRENT[mA] 0.75 max (60Hz, According to IEC60950 and DEN-AN)
OUTPUT WATTAGE[W]
*1
300 500 500 750
VOLTAGE[V]
*2
360
VOLTAGE ACCURACY
*3
±2%
PROTECTION
CIRCUIT AND
OTHERS
OVERVOLTAGE PROTECTION[V]
DC400 - 450V The power factor corrector function stops
ENA
*4
Enable signal, Open-drain output, Maximum sink current 10mA, Maximum allowance voltage 35V
OTHERS
*5
Parallel operation impossible , Thermal protection
ISOLATION
INPUT-OUTPUT Non isolated
INPUT, OUTPUT-FG AC2,800V 1minute Cutoff current = 10mA, DC500V, 50MW min (20±15C)
ENVIRONMENT
OPERA TING TEMP .,HUMID.AND AL TITUDE
-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE) 3,000m (10,000feet) max
STORAGE TEMP .,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis
SAFETY AGENCY APPROVALS UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1
HARMONIC ATTENUATOR Complies with IEC61000-3-2
*
6
OTHERS CASE SIZE/WEIGHT 58.4X12.7X61mm [2.3X0.5X2.4 inches] (WXHXD) / 100g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 Refer to Input voltage derating.
*2 When the input voltage is more than 240V, the output voltage becomes the value proportional to the input voltage.
*3 The value included the output setting and the line regulation, the load regulation and the temperature regulation.
However, the input voltage is less than 240V.
*4 Refer to the instruction Manual.
*5 The thermal protection stops the power factor corrector function and the ENA signal.
*6 Please contact us about class C.
DPG