General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR6 A/B/C/V n n 6 pole relay with force guided contacts according to EN 50205 Reinforced insulation between all contacts Typical applications Emergency shut-off, press control, machine control, elevator and escalator control, safety relays F0206-EA Z Approvals VDE Cert. No. 128935, UL E214025, TUV 968/EL 350, CCC 2012010304537809 Coil Data Coil voltage range Max. coil power 5 to 110VDC 1200mW or 800mW Technical data of approved types on request Contact Data Contact arrangement 3 form A + 3 form B contacts 3 NO + 3 NC, 4 form A + 2 form B contacts 4 NO + 2 NC, 5 form A + 1 form B contacts 5 NO + 1 NC Rated voltage 250VAC Max. switching voltage 400VAC Rated current 8A Contact material AgSnO2, AgSnO2 + 0.2m Au Contact style single contact, force guided type A according to EN 50205 Min. recommended contact load 5V, 10mA Initial contact resistance 100m at 1A, 24VDC 20 at 10mA, 5VDC Frequency of operation, with/without load 6/150min-1 Contact ratings, IEC60947-5-1, on 2 form A (NO) contact AC15-5A DC13-6A Mechanical endurance 10x106 operations Coil versions, DC-coil 800mW Coil Rated Operate code voltage voltage VDC VDC K12 12 9 K15 15 11.3 K18 18 13.5 K21 21 16 K24 24 18 K36 36 27 K48 48 36 L10 110 82.5 Release voltage VDC 1.2 1.5 1.8 2.1 2.4 3.6 4.8 11.0 Coil resistance 10% 180 281 405 551 720 1620 28801) 151301) Rated coil power mW 800 801 800 800 800 800 800 800 1) Coil resistance 12%. All figures are given for coil without pre-energization, at ambient temperature +23C. Coil versions, DC-coil 1200mW Coil Rated Operate code voltage voltage VDC VDC 005 5 3.8 006 6 4.5 009 9 6.8 012 12 9 018 18 13.5 021 21 16 024 24 18 036 36 27 040 40 30 048 48 36 060 60 45 110 110 83 Release voltage VDC 0.5 0.6 0.9 1.2 1.8 2.1 2.4 3.6 4.0 4.8 6.0 11.0 Coil resistance 10%1) 21 30 68 120 270 368 480 1080 1333 1920 30001) 100801) Rated coil power mW 1190 1200 1191 1200 1200 1198 1200 1200 1200 1200 1200 1200 1) Coil resistance 12%. All figures are given for coil without pre-energization, at ambient temperature +23C. 06-2017, Rev. 0617 www.te.com (c) 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change. 1 General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR6 A/B/C/V (Continued) Insulation Data Other Data Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between open contacts between contact and coil between adjacent contacts Insulation to EN 50178, type of insulation between contact and coil between adjacent contacts Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Ambient temperature -25 to 70C Category of environmental Protection IEC 61 810 RTIII1) 1500Vrms 4000Vrms 3000Vrms microdisconnection 5.5/5.5mm 5.5/5.5mm 1) See product specification 2158003 4.6 and 4.8. Weight30g Resistance to soldering heat THT IEC 60068-2-20 260C/5s Packaging/unit tube/10 pcs. reinforced reinforced For more detailed information see product specification 2158003 Dimensions SR6 A/B/C SR6 V S0367-DN S0367-DU PCB layout / terminal assignment Bottom view 3form A + 3 form B, 3 NO + 3NC versions SR6 A 4form A + 2 form B, 4 NO + 2NC versions SR6 B S0368-CA S0368-CC 5form A + 1 form B, 5 NO + 1 NC versions SR6 C S0368-CA S0368-CB S0368-CE S0368-CD 4form A + 2 form B, 4 NO + 2NC versions SR6 V The design of the SR6 V allows clearance/creepage of 5.5mm on the PCB. S0368-CU 2 06-2017, Rev. 0617 www.te.com (c) 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions S0368-CV Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change. General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR6 A/B/C/V (Continued) Product code structure Typical product code SR6 A 4 012 Type SR6 Relay with force guided contacts SR6 Contact arrangement A 3 form A + 3 form B contacts (3 NO + 3 NC) B 4 form A + 2 form B contacts (4 NO + 2 NC) V 4 form A + 2 form B contacts (4 NO + 2 NC) (crossed pin layout) C 5 form A + 1 form B contacts (5 NO + 1 NC) Contact material 4 AgSnO2 for 1200mW version 6 AgSnO2 + 0.2m Au for 800mW version Coil Coil code: please refer to coil versions table (e.g. 024=24VDC) Other types on request Product code SR6A4005 SR6A4012 SR6A4021 SR6A4024 SR6A4048 SR6A4060 SR6A4110 SR6A6K12 SR6A6K18 SR6A6K24 SR6B4005 SR6B4006 SR6B4012 SR6B4018 SR6B4021 SR6B4024 SR6B4040 SR6B4048 SR6B4060 SR6B4085 SR6B4110 SR6B6K12 SR6B6K15 SR6B6K18 SR6B6K21 SR6B6K24 SR6C4012 SR6C4024 SR6C4048 SR6C4060 SR6C4110 SR6C6K24 SR6V6K12 SR6V6K15 SR6V6K18 SR6V6K21 SR6V6K24 Type 6 pole relay with force guided contacts Cont. arrangement 3 form A + 3 form B, 3 NO + 3 NC contacts Cont. material AgSnO2 AgSnO2 + Au 4 form A + 2 form B, 4 NO + 2 NC contacts AgSnO2 AgSnO2 + Au 5 form A + 1 form B, 5 NO + 1 NC contacts 4 form A + 2 form B, 4 NO + 2 NC contacts (crossed pin layout) AgSnO2 AgSnO2 + Au Coil 5VDC 12VDC 21VDC 24VDC 48VDC 60VDC 110VDC 12VDC 18VDC 24VDC 5VDC 6VDC 12VDC 18VDC 21VDC 24VDC 40VDC 48VDC 60VDC 85VDC 110VDC 12VDC 15VDC 18VDC 21VDC 24VDC 12VDC 24VDC 48VDC 60VDC 110VDC 24VDC 12VDC 15VDC 18VDC 21VDC 24VDC Coil Power 1200mW Alt. Description V23050-A1005-A533 V23050-A1012-A533 V23050-A1021-A533 V23050-A1024-A533 V23050-A1048-A533 V23050-A1060-A533 V23050-A1110-A533 800mW 1200mW V23050-A1005-A542 V23050-A1006-A542 V23050-A1012-A542 V23050-A1018-A542 V23050-A1021-A542 V23050-A1024-A542 V23050-A1040-A542 V23050-A1048-A542 V23050-A1060-A542 V23050-A1085-A542 V23050-A1110-A542 800mW 1200mW V23050-A1012-A551 V23050-A1024-A551 V23050-A1048-A551 V23050-A1060-A551 V23050-A1110-A551 800mW Part Number 8-1415017-1 1-1415015-1 3-1415018-1 1415015-1 6-1415018-1 7-1415018-1 9-1415018-1 6-1415537-1 6-1415537-3 6-1415537-5 1393260-1 1393260-2 1393260-4 1393260-5 1393260-6 1393260-7 1393260-9 1-1393260-0 1-1393260-1 1-1393260-2 1-1393260-3 7-1415537-6 7-1415537-7 7-1415537-8 7-1415537-9 8-1415537-0 1-1415017-1 1415017-1 2-1415019-1 3-1415019-1 5-1415019-1 9-1415537-4 3-1415542-5 2-1415543-2 3-1415543-3 4-1415542-4 5-1415539-2 06-2017, Rev. 0617 www.te.com (c) 2015 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change. 3