SPEC Pak (R) Sealed Power For Environmental Connections Solar Power | LED Lighting Wind Power | | Solar Panels DC Lighting | | Inverters Combiner Boxes | | Micro Inverters Hydro-Electricity | | Battery Back up Harsh Environments (R) Anderson Power Products (R) Rugged and Sealed (IP68) Plugs and Receptacles For Use with APP(R) Powerpole(R) Signal, Power & Ground Contacts & Housings APP(R)'s Solar SPEC Pak(R) Connector Series uses rugged and environmentally sealed (IP68) shells to protect industry leading APP(R) Powerpole(R) contacts and housing. Customer configured Solar SPEC Pak(R) is designed specifically to meet the requirements of the photovoltaic industry conforming to NEC 2008 requirements for first make/last break ground and a locking feature that require a tool to unlock. It's also the first multipole connector to conform to UL 6703A. The adaptive design lends itself towards use in other markets including wind power, fuel cells, mass transportation, off-road vehicles, agricultural equipment, oil and petro chemical exploration and many more. The core APP(R) Powerpole(R) technology within the SPEC Pak(R) is proven reliable and cost effective. The broad selection of touch safe, color-coded Powerpole(R) housings with power, signal and ground contacts accept a broad range of wire gauges, #24 to #10 AWG (0.25 to 4.0 mm), giving users thousands of flexible design solutions in a single interconnect. 1 2 3 5 4 6 7 9 8 Configurable to 1000 Volts 5 - Power Contacts (up to 4) and / or Signal Contacts (up to 16) 1 - Chemical & UV Resistant Ruggedized Shells 6 - Uses Industry Standard Sealing Components * Wire to wire configurations * Panel mount configurations 2 - Touch Safe Housings (UL1977, Section 10.2) (PG gland compatible - size 16) 7 - First Mate / Last Break Ground Contacts (NEC 2008, Section 690.33D) 3 - IP68 Interfacial Sealing Gasket 8 - Housing Colors to Match Wire Colors for ease of Assembly 4 - Locking Latch (NEC 2008, Section 690.33C) 9 - Unlocking Tool -2- www.andersonpower.com Specifications ............................. SPEC Pak(R) Shells Used With .......................... SPEC Pak(R) Shell Powerpole(R) Power Contacts & Housings (1327FP Series) Powerpole(R) Ground Contacts & Housings (1827 Series) PPMX 1 Signal Contacts & Housings (4800 Series) - 15 to 40 20 10 to 26 40 35 7 5 Voltage Rating UL 1977 (AC/DC) UL 6703A (AC) IEC 60664 (AC/DC) - 600 600 1,000 600 600 - 300 - Dielectric Withstanding (AC/DC) - 2,200 2,200 1,600 Contact Resistance (average) - 525 525 - Hot Plug 2 (UL 1977) 250 Cycles at 120V - 30 30 - IP68 Pass - - - - 20 to 10 AWG 0.5 to 4.0 mm 14 to 10 AWG 1.5 to 4.0 mm 24 to 20 AWG 0.25 to 0.5 mm -40 to 105C -40 to 221F -20 to 105C -4 to 221F -20 to 105C -4 to 221F -20 to 105C -4 to 221F -35 to 65C -31 to 149F - - - Mating Cycles (no load) Tin Silver Gold - 1,500 10,000 - 1,500 - 5,000 Latch Mating Cycles Lock (NEC 2008 Sec 690.33C) 200 Pass - - - Contact Retention Force (lbf) (N) - 25.0 111.0 25.0 111.0 12.0 53.0 Insertion Force (lbf) (N) - - 3.0 13.3 4.5 max 20.0 max Touch Safe (UL 1977 Sec 10.2) - Electrical Current Rating (Amprese) UL 1977 UL 6703A CSA (30C Rise) Mechanical Environmental Seal IP rating UL 50 Sec 36 Wire Size Operating Temperature UL 1977 UL 6703A Pass - - Mechanical Shock (50g) Mil Standard 202 213 Cond A Pass - - Vibration (10g) Mil Standard 202 204 Cond A Pass - - PBT / PC PC PPE PC - PC - PBT / PC - Flammability (UL 94) V0 V0 V0 V0 Weatherability (UL 764C) F1 - - - -35C Impact Test (UL 6703A Sec 30) Pass - - - Thermal Cycle Test (UL 6703A Sec 35) Pass - - - Humidity Cycle Test (UL6703A Sec 36) Pass - - - Contacts Base Plating - Copper Alloy Tin or Silver Copper Alloy Tin or Silver Copper Alloy Gold, 50 Materials Shell / Housing Powerpole(R) Holder Latch Notes: 1. PPMX housing holds up to 2 pin and 2 sockets. 2. Hot Plug testing completed using individual Powerpole(R) housings and contacts, not installed in SPEC Pak(R) shells. For other industry test and/or agency approvals, contact customer service. www.andersonpower.com -3- Part Number Configurator PART NUMBER PLAN SPEC Pak(R) Series Shell Color Shell Style (1 Fixed Character) (1 Character) (1 Character) Dash K 2 - P P = Solar SPEC Pak(R) K = Black PANEL MOUNT RECEPTACLE KIT Plug Shell Panel Mount Gasket Panel Mount Latch Receptacle Shell Receptacle Powerpole(R) Holder Insert Arrangement (mm) (3 Characters) (3 Characters) 050 1 = Inline Receptacle 2 = Panel Mount Receptacle 6 = Straight Plug 9 = Panel Mount Receptacle Cover 9R = Inline Receptacle Cover 9P = Plug Cover PLUG KIT Plug Powerpole(R) Holder Shell Size B04 050 = 50 mm - 4 Pole Shell B04 = PP15/45 Housing (any type), 4 Pole INLINE RECEPTACLE KIT Inline Receptacle Shell Latch Receptacle Powerpole(R) Holder IP68 SEALING COVER KIT Receptacle Cover Plug Cover Interfacial Sealing Gasket NOTE: - Mounting hardware (4 each - M3 or #4 screws) not included - Recommended torque for mounting hardware is 21/2 to 4 in-lbf (0.28 to 0.45 N) ORDERING INFORMATION -4- SPEC Pak(R) Shell Kits Component Replacement Parts Part Number PK6-050B04 Part Number 114805P1 2-8709P1 PKT-050T01 Description Plug shell kit - Plug shell (includes interfacial sealing gasket) - Powerpole(R) holder for plug PK2-050B04 Panel mount receptacle shell kit - Panel mount receptacle shell with locking latch - Powerpole(R) holder for receptacle - Panel mount gasket for receptacle PK1-050B04 Inline receptacle shell kit - Inline receptacle shell with locking latch - Powerpole(R) holder for receptacle PK9P-050 Cover kit for plug - Protective sealing (IP68) cover with lanyard - With locking latch PK9-050 Cover kit for panel mount receptacle - Protective sealing (IP68) cover with lanyard PK9R-050 Cover kit for inline receptacle - Protective sealing (IP68) cover with lanyard www.andersonpower.com Description Panel mount gasket for receptacle 4 position solar locking latch 4 position solar unlocking tool (for use with locking latch) PART NUMBER PLAN Wire Protection Housing Arrangement See pages 6 & 7 (4 Characters) For more information see pages 8 & 9 (1 Character) (2 Characters) PS 00 = None PS = Plastic Short PF = Plastic With Flex Spring PR = Plastic Right Angle PM = Plastic Multi Hole CT = Conduit Adapter Threaded CA = Conduit Adapter Push-in Dash 01 00 = None 01-99 = Varies By Gland Type NOTE: 1. See PG Gland charts on page 6 & 7 for details. 2. Panel Mount receptacle side is always "00". - 0 Contact 00 0 = Custom Configuration - Use Next Section A = AC, Single Phase B = AC, 3 Phase, 3 Wire C = DC, 2 Circuit, 4 Wire D = DC, 2 Wire, With Ground H = DC, 2 Wire, With 8 Signal J = AC, Single Phase, With 4 Signal L = DC, 2 Wire, With 4 Signal N = DC, 2 Wire, With Ground & 4 Signal U = DC, 2 Wire X = All Signal APP(R) Content Dash (3 Characters) - Leave Blank Custom Configuration* Contact Factory 00 = Custom Configuration - Use Next Section 01 = 261G2 Contact for #10 to #14 AWG (4.0 to 1.5 mm) Wire 02 = 200G1L Contact for #10 to #14 AWG (4.0 to 1.5 mm) Wire 03 = 261G1 Contact for #12 to #16 AWG (2.5 to 1.0 mm) Wire 04 = 1331 Contact for #12 to #16 AWG (2.5 to 1.0 mm) Wire 05 = 262G1 Contact for #16 to #20 AWG (1.0 to 0.5 mm) Wire 06 = 1332 Contact for #16 to #20 AWG (1.0 to 0.5 mm) Wire 99 = All Signal Amperage ratings are available on page 9. Part Numbering Notes: 1. To order SPEC Pak(R) Shell Kits Only (no internal Powerpole(R) housings or contacts), use part numbering on page 4 only. Plug Shell Kit Example: PK6-050B04. Powerpole(R) housings, contacts and wire protection may be ordered separately, see pages 6, 7 and 10 for information. 2. To order SPEC Pak(R) connectors kits (including internal Powerpole(R) housings and contacts) use Part Number Plan across the top of pages 4 and 5. Standard SPEC Pak(R) Plug Configuration Example: PK6-050B04PS01-B01 3. To order a custom configuration which is not listed on page 8 and 9, use custom part number configurator on the APP (R) website, www.andersonpower.com or contact factory. * Custom configuration may not be UL Recognized. www.andersonpower.com -5- Wire Protection - PG Gland SPECIFICATIONS Gland Styles Straight Plastic Straight Plastic With Flex Spring Right Angle Straight Plastic Multi-Hole Straight Conduit Straight Conduit Push-In Mechanical IP Rating Operating Temperature UL 1977 UL 6703A Thread Type Thread Size Flammability (UL 94) Weatherability (UL 764C) Material Shell Gasket Color IP68 IP68 -40 to 105C -40 to 221F -35 to 65C -31 to 149F -31 to 100C -22 to 212F - PG 16 V2 1 F1 PG 16 - Nylon PA 66 EPDM Black Nylon PA 66 TPE Black Torque Requirement Cable Gland Body to Connector Shell * Hand tighten until snug, tighten additional 1/8 to 1/4 turn with wrench Sealing Nut to Cable * Hand tighten until snug, tighten additional 1/2 to 3/4 turn with wrench Notes: 1. For V0 material, contact the factory. SPEC Pak(R) connectors are not UL recognized components when used with cable glands that are not UL listed. STRAIGHT PLASTIC SHORT THREAD TYPE - STD PACK 50 / UL LISTED C1 Washer APP(R) P/N PS1P16-10X PS1P16-14X Wire Protection Designation (4 Characters) PS01 PS02 Body C2 Cable Range Wire Outer Dia. mm (in) 11.2 - 5.5 (0.44 - 0.22) 14.1 - 8.0 (0.56 - 0.31) Seal Thread O. D. C1 mm (in) 22.5 (0.89) 22.5 (0.89) Sealing Nut Panel Mounting Hole mm (in) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) Thread Length C2 mm (in) 10.0 (0.39) 10.0 (0.39) Wrench Size Lock Nut (mm) 30 30 Wrench Size Sealing Nut (mm) 27 27 STRAIGHT PLASTIC WITH FLEX SPRING - STD PACK 50 / UL LISTED C1 Washer APP(R) P/N PF1P16-10X PF1P16-13X Wire Protection Designation (4 Characters) PF01 PF02 C2 Cable Range Wire Outer Dia. mm (in) 11.2 - 5.5 (0.44 - 0.22) 13.8 - 8.0 (0.54 - 0.31) Body Seal Thread O.D. C1 mm (in) 22.5 (0.89) 22.5 (0.89) Sealing Nut Panel Mounting Hole mm (in) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) Thread Length C2 mm (in) 11.0 (0.43) 11.0 (0.43) Wrench Size Lock Nut (mm) 30 30 RIGHT ANGLE - STD PACK 50 / UL LISTED Wrench Size Sealing Nut (mm) 27 27 LOCK NUT FOR PG 16 CABLE GLANDS C2 Washer Wire Protection Designation APP(R) P/N (4 Characters) PR1P16-10X PR01 PR1P16-13X PR02 -6- Cable Range Wire Outer Dia. mm (in) 11.0 - 7.0 (0.43 - 0.28) 13.0 - 8.0 (0.51 - 0.31) www.andersonpower.com C1 Body Thread O.D. C1 mm (in) 22.5 (0.89) 22.5 (0.89) Seal Panel Mounting Hole mm (in) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) Claw Thread Length C2 mm (in) 12.0 (0.47) 12.0 (0.47) Sealing Nut Wrench Size Lock Nut (mm) 30 30 Wrench Size Sealing Nut (mm) 27 27 Lock Nut APP(R) Wrench Size Std. Pkg. P/N Lock Nut (mm) Size 124G31 30 50 STRAIGHT PLASTIC MULTI-HOLE TYPE - STD PACK 50 / NOT UL LISTED C1 Washer APP(R) P/N PS2P16-3X PS2P16-4X PS2P16-6X PS3P16-3X PS3P16-5X PS4P16-2X PS4P16-3X PS4P16-4X PS5P16-2X PS5P16-3X PS5P16-4X PS6P16-2X PS6P16-3X Wire Protection Designation (4 Characters) PM21 PM22 PM23 PM31 PM32 PM41 PM42 PM43 PM51 PM52 PM53 PM61 PM62 Number of Holes 2 2 2 3 3 4 4 4 5 5 5 6 6 Body C2 Seal Cable Range Wire Outer Dia. mm (in) 3.5 - 2.5 (0.14 - 0.10) 4.3 - 3.3 (0.17 - 0.13) 6.1 - 4.3 (0.24 - 0.17) 3.6 - 2.6 (0.14 - 0.10) 5.2 - 3.5 (0.20 - 0.14) 2.5 - 1.6 (0.10 - 0.06) 3.6 - 2.5 (0.14 - 0.10) 4.8 - 3.4 (0.19 - 0.13) 2.1 - 1.3 (0.08 - 0.05) 3.1 - 2.0 (0.12 - 0.08) 4.1 - 3.0 (0.16 - 0.12) 2.0 - 1.3 (0.08 - 0.05) 3.0 - 2.0 (0.12 - 0.08) Thread O.D. C1 mm (in) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) Claw Sealing Nut Panel Mounting Hole mm (in) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) Thread Length C2 mm (in) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) Wrench Size Lock Nut (mm) 30 30 30 30 30 30 30 30 30 30 30 30 30 Wrench Size Sealing Nut (mm) 27 27 27 27 27 27 27 27 27 27 27 27 27 STRAIGHT CONDUIT ADAPTER THREAD TYPE - STD PACK 50 / NOT UL LISTED F1 C1 Washer APP(R) P/N CT1P16-15X CT1P16-18X CT1P16-21X Wire Protection Designation (4 Characters) CT01 CT02 CT03 Max. Joint F1 mm (in) 16.0 (0.63) 18.3 (0.72) 22.0 (0.87) Body C2 Thread O.D C1 mm (in) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) Seal Sealing Nut Panel Mounting Hole mm (in) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) Thread Length C2 mm (in) 11.0 (0.43) 11.0 (0.43) 11.0 (0.43) Corrugated Wrench Size Lock Nut (mm) 30 30 30 Conduit Trade Size OD15.8 OD21.2 APP(R) Conduit P/N NGN - 12B NGN - 14B NGN - 17B STRAIGHT CONDUIT PUSH-IN TYPE - STD PACK 50 / NOT UL LISTED C1 Washer APP(R) P/N CAP16-15X CAP16-18X CAP16-21X CAP16-28X Wire Protection Designation (4 Characters) CA01 CA02 CA03 CA04 Thread O.D. C1 mm (in) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) 22.5 (0.89) C2 Body Seal Panel Mounting Hole mm (in) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) 22.5 - 22.8 (0.89 - 0.90) Thread Length C2 mm (in) 10.0 (0.39) 10.0 (0.39) 10.0 (0.39) 12.0 (0.47) Wrench Size Lock Nut (mm) 30 30 30 30 Wrench Size Sealing Nut (mm) 21 21 27 34 APP(R) Conduit P/N NGN - 12B NGN - 17B NGN - 23B Conduit Trade Size OD15.8 OD18.5 OD21.2 OD28.5 For R/A versions contact Factory CORRUGATED NYLON PLASTIC TUBING APP(R) P/N NGN - 12B NGN - 14B NGN - 17B NGN - 23B Conduit I. D. mm (in) 11.8 (0.46) 13.8 (0.54) 16.7 (0.66) 21.7 (0.85) Conduit O. D. mm (in) 15.8 (0.62) 17.8 (0.70) 21.2 (0.83) 28.5 (1.12) Conduit Size 3/8" 1/2" 3/4" Trade Size (mm) OD15.8 OD21.2 OD28.5 Std. Pkg. Meters (Feet) 50 (164) 50 (164) 50 (164) 50 (164) TUBING CUTTER APP(R) P/N TM0002 Description Corrugated Plastic Tubing Cutter Range (mm) Up to OD 34.5 www.andersonpower.com -7- Standard Housing Arrangements & Contacts HOUSING ARRANGEMENTS FOR POWER, SIGNAL & GROUND CONNECTORS ARRANGEMENTS REPRESENT FRONT VIEW OF RECEPTACLE Custom configuration may be created using APP's part number configurator at www.andersonpower.com E = Empty 0 A B 1327 Series = Power Custom Configuration AC Single Phase 1327G6FP 1327G7FP D 1327G6FP 1327FP 1327G6FP 1327FP DC 2 Wire With Ground 1327G6FP 1327FP E 1827GA DC 2 Wire With 8 Signal H 4827G6 1327G6FP Notes: 600 Volt Rating * UL 1977 - All Configurations * UL 6703A - Configuration B * IEC 60664 - All Configurations 1000 Volt Rating * IEC 60664 - Configuration U -8- www.andersonpower.com L 1327FP 1827GA DC 2 Circuit, 4 Wire C J E 1827GA AC 3 Phase, 3 Wire 1327G6FP 1327G7FP 1827 Series = Ground 4827G6 1327FP N U X 4800 Series = Signal AC Single Phase With 4 Signal 1327G6FP 1327G7FP 4827G6 1827GA DC 2 Wire With 4 Signal 1327G6FP E 1327FP 4827G6 DC 2 Wire With Ground & 4 Signal 1327G6FP 4827G6 1327FP 1827GA DC 2 Wire 1327G6FP E E 1327FP All Signal 4827G6 4827G6 4827G6 4827G6 CONTINUOUS CURRENT RATINGS - POWER CONTACT CODE SELECTION NOTES: 1. Current ratings under UL1977: * First number represents current rating per pole for 30C temperature rise (25 / 38) * Second number is the maximum recommended current per pole based on a 25C ambient (25 / 38) (Current ratings under UL 6703A, contact the factory) 2. Configuration H - N based on signal contacts crimped to #20 AWG wire and carrying 1 amp. 3. Denotes wire size not appropriate for power contact. 4. Shaded boxes are pending. 5. 1827GA housing should be used with 1830G1 or 1830G2 ground contact, depending on primary contacts. All signal housings (4850) available with up to two 4802G3 and two 4803G3 contacts. TEMPERATURE CHART HOLDER LOCATIONS (VIEWS) Receptacle Plug Back Front Back 1 2 2 1 3 4 4 3 2 1 1 2 4 3 3 4 SPEC Pak(R) (4) Pole - Temperature Rise Based on 261G2 Contact 50 Temperature (C) Front 40 30 20 10 0 0 5 10 15 20 25 Amperes 30 35 40 #10 AWG #12 AWG #14 AWG www.andersonpower.com -9- Individual components POWERPOLE(R) HOUSINGS & CONTACTS Fingerproof PP15/45 Housing Only Package Quantity: Standard, 200 pieces - Bulk, 2,500 pieces Standard Part Number 1327FP 1327G5FP 1327G6FP 1327G7FP 1327G8FP 1327G16FP Bulk Part Number 1327FP-BK 1327G5FP-BK 1327G6FP-BK 1327G7FP-BK 1327G8FP-BK 1327G16FP-BK Description Red Housing Green Housing Black Housing White Housing Blue Housing Yellow Housing Standard PP 15/45 Housing Only Package Quantity: Standard, 200 pieces - Bulk, 2,500 pieces Standard Part Number 1327 1327G5 1327G6 1327G7 1327G8 1327G16 1327G17 1327G18 1327G21 1327G22 1327G23 Bulk Part Number 1327-BK 1327G5-BK 1327G6-BK 1327G7-BK 1327G8-BK 1327G16-BK 1327G17-BK 1327G18-BK 1327G21-BK 1327G22-BK 1327G23-BK Description Red Housing Green Housing Black Housing White Housing Blue Housing Yellow Housing Orange Housing Gray Housing Brown Housing Pink Housing Purple Housing Premate Ground PP15/45 Housing Only 15/45 Powerpole(R) Contacts Loose Piece Package Quantity: Standard, 200 pieces - Bulk, 5,000 pieces Standard Bulk Part Number Part Number #16 to #20 AWG (1.0 to 0.5 mm) 1332 1332-BK 262G1-LPBK 262G2-LPBK - Individual-LD-Silver Plate Singulated Reel-LD-Tin Plate Singulated Reel-LD-Silver Plate #12 to #16 AWG (2.5 to 1.0 mm) 1331 1331-BK 261G1-LPBK - Individual-LD-Silver Plate Singulated Reel-LD-Tin Plate #10 to #14 AWG (4 to 1.5 mm) 261G2-LPBK 261G3-LPBK 200G1L-LPBK - Singulated Reel-LD-Tin Plate Singulated Reel-LD-Silver Plate Superflex, Sing. Reel-LD-Tin Plate Description Reel - 15/45 Powerpole(R) Contacts Package Quantity 5,000 Part Number Description #16 to #20 AWG (1.0 to 0.5 mm) 262G1 Reel-LD-Tin Plate 262G2 Reel-LD-Silver Plate Package Quantity: Standard, 200 pieces - Bulk, 2,500 pieces #12 to #16 AWG (2.5 to 1.0 mm) 261G1 Reel-LD-Tin Plate Standard Part Number 1827GA #10 to #14 AWG (4 to 1.5 mm) 261G2 Reel-LD-Tin Plate 261G3 Reel-LD-Silver Plate Bulk Part Number 1827GA-BK Description Green Housing Premate Ground Contacts Loose Piece Package Quantity 200 Part Number Description #10 to #14 AWG (4 to 1.5 mm) 1830G1-LPBK Singulated-LD-Tin Plate 1830G2-LPBK Singulated-LD-Silver Plate #10 to #14 AWG (6 to 1.5mm) 200G1L SuperFlex, Reel-LD-Tin Plate NOTE: LD - Low Detent CONTACT STYLES Reel Package Quantity 5,000 Part Number Description #10 to #14 AWG (4 to 1.5 mm) 1830G1 Reel-LD-Tin Plate 1830G2 Reel-LD-Silver Plate - 10 - www.andersonpower.com Individual Singulated Open Barrel On a Reel PP15/45 POWERPOLE(R) HOUSING STYLES PPMX (4800 SERIES) HOUSING & CONTACTS PPMX Signal Housing Powerpole(R) Fingerproof Housing Rib Feature Package Quantity Standard, 25 pieces - Bulk, 1,000 pieces Standard Part Number 4827G6 Bulk Part Number 4827G6-BK 1327FP Series Description Black two piece housing PPMX Signal Contacts Powerpole(R) Standard Housing Closed Nose Package Quantity Standard, 50 pieces - Bulk, 2,000 pieces 1327 Series Loose Piece #20 to #24 AWG (0.50 to 0.25 mm) Standard Part Number 4802G3 4803G3 Bulk Part Number 4802G3-BK 4803G3-BK Powerpole(R) Premate Ground Housing Open Nose Description Socket, Gold, 50 Micro-inches Pin, Gold, 50 Micro-inches PPMX Signal Housing & Contact Kits PPMX Housing 2 Socket & 2 Pin Contacts Open Nose Package Quantity Standard, 100 pieces 1827 Series 4800 Series 1 Black two piece housing, 2 Male Contacts, 2 Female Contacts Standard Part Number 4850G6 Bulk Part Number - Description 50 Micro-inches Gold Plated Contacts - Pin & Socket APPLICATION TOOLING - POWERPOLE(R) 15 / 45 CONTACTS Loose Piece Tin Part Number Loose Piece Silver Part Number N/A 1332 N/A 1331 Hand Tool* or 1309G2 or 1309G8** Reeled Tin Part Number Pneumatic Tool* 1367G1 Reeled Silver Part Number ATS Applicator N/A N/A N/A N/A N/A N/A 261G1 262G2 1385520 262G1-LPBK 262G2-LPBK 200G2L-LPBK 200G4L-LPBK 200G2L 200G4L TBD 261G1 261G4 1385520 261G1-LPBK 261G4-LPBK 261G2-LPBK 261G3-LPBK 200G1L-LPBK 200G3L-LPBK 1830G1-LPBK 1830G2-LPBK 1309G3 or 1309G8** N/A 1309G6 or 1309G8** 261G2 261G3 1385458 200G1L 200G3L 1385460 1830G1 1830G2 1385460 * All Hand and Pneumatic Tools for use with Loose Piece contacts only. All reeled contacts can be ordered singulated, (Loose Piece) with the suffix "- LPBK" ** 1309G8 is a hand tool kit- includes dies and locators to make up 1309G2, 1309G3, &1309G6 APPLICATION TOOLING - PPMX CONTACTS Contact Part Number 4802G3 4803G3 APP(R) Hand Tool or PM1000G1 Mil Std.Hand Tool (APP Part #) M22520/1-01 (TM0001) + Positioner No Mil Std. (TL0005) Pneumatic Tool for Locator / + Turret TP0001 www.andersonpower.com - 11 - Dimensions PLUG 4 POSITION FOR PP15/45 HOUSINGS Top View Front View PG 16 FEMALE THREAD [ 40.4 ] 1.59 [ 68.3 ] 2.69 Side View Mated Side View [ 95.1 ] 3.74 [ 53.6 ] 2.11 [ 33.7 ] 1.33 INTERFACIAL GASKET [ 43.9 ] 1.73 [ 68.3 ] 2.69 PANEL MOUNT RECEPTACLE 4 POSITION FOR PP15/45 HOUSINGS Panel Cut Out Front View [ 33.0 ] 1.30 Side View [ 44.5 ] 1.75 [ 55.6 ] 2.19 [ 44.5 ] 1.75 [ 33.0 ] 1.30 Back View [ 44.5 ] 1.75 [ 50.3 ] 1.98 [ 50.2 ] 1.98 INLINE RECEPTACLE 4 POSITION FOR PP15/45 HOUSINGS Top View Front View Side View Mated Side View [ 35.4 ] R1.36 SWEEP OF LATCH [ 123.6 ] 4.87 [ 29.4 ] 1.16 [ 38.7 ] 1.52 [ 68.6 ] 2.70 PG GLANDS PS - Plastic Short CT - Threaded Conduit Adapter CA - Push-in Conduit Adapter PF - Plastic Flex PG RECEPTACLE COVER KIT Front View PLUG COVER KIT Side View [ 33.7 ] 1.33 PR - Right Angle Front View Side View [ 50.2 ] 1.98 [ 38.4 ] 1.51 [ 23.2 ] 0.91 [ 38.2 ] 1.50 [ 54.1 ] 2.13 All Data Subject To Change Without Notice Patents with Patents Pending 15145 DS-SOLARSPAK REV 02 HEADQUARTERS: Anderson Power Products(R), 13 Pratts Junction Road, Sterling, MA 01564-2305 USA T:978-422-3600 F:978-422-0128 EUROPE: Anderson Power Products(R) Ltd., Unit 3, Europa Court, Europa Boulevard, Westbrook, Warrington, Cheshire, WA5 7TN United Kingdom T: +44 (0) 1925 428390 F: +44 (0) 1925 520203 ASIA / PACIFIC: IDEAL Anderson Asia Pacific Ltd., Unit 922-928 Topsail Plaza, 11 On Sum Street, Shatin N.T., Hong Kong T:+(852) 2636 0836 F:+(852) 2635 9036 CHINA: IDEAL Anderson Technologies (Shenzhen) Ltd., Block A8 Tantou Western Industrial Park, Songgang Baoan District, Shenzhen, PR. China 518105 T: +(86) 755 2768 2118 F: +(86) 755 2768 2218 - 12 - www.andersonpower.com TAIWAN: IDEAL Anderson Asia Pacific Ltd., Taiwan Branch, 4F.-2, No.116, Dadun 20th St., Situn District, Taichung City 407, Taiwan (R.O.C.) T: +(886) 4 2310 6451 F:+(886) 4 2310 6460 www.andersonpower.com Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Anderson Power Products: 115125G1 115126G1 115150G1 3-6014P1 3-6015P1 115129P1 SK2-095H060000-G11 SK6-A95H03PS04-R28 SK6-B95H02PM46-R80 SK1-A95H06PM22-G16 SK6-A95H03PS04-A29 SK2-095H030000-A29 SK1-A95H03PS04A29 SK1-A95H03PS04-R28 SK2-095H020000-R80 SK2-095H03PS04-R28 SK6-A95H02PM21-R81 SK6A95H02PM22-R81 SK6-A95H06PS04-G11 SK2-095H020000-R85 SK2-095H030000-R23 SK2-095H060000-G16 SK6-A95H06PM22-G16 SK6-016M030000-P41 SK1-016M030000-S42 SK1-016M03PB01-S41 SK1-016M03PB01S42 SK1-016M03PB01-S43 SK6-016M030000-P42 SK6-016M03PB01-P42 SK6-016M03PB01-P41 SK6016M03PB01-P43 SK2-050B040000-C01 SK2-050B040000-J01 SK2-050B040000-X99 SK6-050B04PS01-N03 SK6050B04PS02-D03 SK1-050B04PS01-B01 SK6-050B04PS01-B03 SK6-050B04PS01-C01 SK6-050B04PS01-C04 SK1-050B04PS01-N03 SK6-050B04PS02-B01 SK6-050B04PS02-C01 SK6-050B04PS02-X99 SK6-050B04PS03-B01 SK1-050B04CT03-C02 SK1-050B04PM41-C02 SK6-050B04PM21-C01 SK6-050B04PM41-C02 SK6-050B04PM42C01 SK6-050B04PS01-B01 SK1-050B04PS01-C01 SK1-050B04PS02-B01 SK6-050B04PS01-A01 115047G2 115048G1 115108P1 SK1-050B04PM21-C01 SK1-050B04PS02-B02 SK2-050B040000-A02 SK2-050B040000-B01 SK2-050B040000-B02 SK2-050B040000-D03 SK6-050B04CT03-C02 SK6-050B04PS01-D03 SK6-050B04PS02-A02 SK6-050B04PS02-B02 SK2-050B040000-A01 SK2-050B040000-C04 SK1-050B04PS01-B03 SK1-050B04PS02A04 1827GA-BK PK2-050B040000-D01 PK6-050B04PS01-B01 PK1-050B04PM32-A01 PK6-050B04PR01-A01 PK2-050B040000-A01 PK6-050B04PS02-A01 PK6-050B04PR02-A01 PK1-050B04PS01-B01 PK2-050B040000-B01 PK6-050B04PS01-D01