Specific Lighting Product Data Sheet LTW-006DCG-E2 Spec No.: DS22-2009-0147 Effective Date: 11/28/2015 Revision: F LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien 1 Road, Chung Ho, New Taipei City 23585, Taiwan, R.O.C. Tel: 886-2-2222-6181 Fax: 886-2-2221-1948 / 886-2-2221-0660 http://www.liteon.com/opto Specific Lighting LTW-006DCG-E2 1. Description The LTW (LiteOn White PLCC LED) is a revolutionary, energy efficient and ultra compact new light source, combining the lifetime and reliability advantages of Light Emitting Diodes with the brightness of conventional lighting. It gives you total design freedom and unmatched brightness, creating a new opportunities for solid state lighting to displace conventional lighting technologies.. . 1. Features 1.2. Applications Package in 12mm tape on 7" diameter reels. Compatible with automatic placement equipment. Compatible with infrared and vapor phase reflow solder process. EIA STD package. I.C. compatible. Meet green product and Pb-free(According to RoHS) Reading lights (car, bus, aircraft) Portable (flashlight, bicycle) Downlighters/Orientation Decorative/Entertainment Bollards/Security/Garden Cove/Undershelf/Task Traffic signaling/Beacons/ Rail crossing and Wayside Indoor/Outdoor Commercial and Residential Architectural Edge_lit signs (Exit, point of sale) 2. Outline Dimensions 1/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 Part No. Lens Color Source Color LTW-006DCG-E2 Yellow InGaN White Notes : 1. All dimensions are in millimeters (inches). 2. Tolerance is 0.1 mm (.004") unless otherwise noted. Absolute Maximum Ratings at Ta=25 LTW-006DCG-E2 Unit 120 mW 100 mA DC Forward Current 30 mA Reverse Voltage 5 V Parameter Power Dissipation Peak Forward Current (1/10 Duty Cycle, 0.1ms Pulse Width) Operating Temperature Range -30 to + 85 Storage Temperature Range -40 to + 100 Reflow Soldering Condition 260 For 10 Seconds Note: Operating the LED (in an application) under reverse bias condition might result in damage or failure of the component 2/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 Suggest IR Reflow Condition : R-Reflow Soldering Profile for lead free soldering (Acc. to J-STD-020D) 3/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 Electro-Optical Characteristics at Ta=25C Parameter Luminous Intensity Viewing Angle Symbol Part No. LTW- IV 006DCG-E2 21/2 006DCG-E2 Min. 1900 ESD-Withstand Voltage Unit 2600 mcd deg Test Condition IF = 20mA Note 1, 2, 5 Fig.6 IF = 20mA 0.277 006DCG-E2 Note 3, 5 y Forward Voltage Max. 110 x Chromaticity Coordinates Typ. 0.255 VF 006DCG-E2 2.9 ESD 006DCG-E2 200 Fig.1 3.3 V IF = 20mA V HBM Notes: 1. Luminous flux is measured with a light sensor and filter combination that approximates the CIE eye-response curve. 2. Lm classification code is marked on each packing bag. 3. The chromaticity coordinates (x, y) is derived from the 1931 CIE chromaticity diagram. 4. Caution in ESD: Static Electricity and surge damages the LED. It is recommend to use a wrist band or anti-Slectrostatic glove when handling the LED. All devices, equipment and machinery must be properly grounded. 5. CAS140B is the test standard for the chromaticity coordinates (x, y) & IV. 6. The chromaticity coordinates (x, y) guarantee should be added +/- 0.007 tolerance. 4/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 Bin Code List VF Spec. Table VF Bin Forward Voltage (volts) at IF = 20mA Min. Max. V0 2.9 3.0 V1 3.0 3.1 V2 3.1 3.2 V3 3.2 3.3 Tolerance on each Forward Voltage bin is +/- 0.1 V Luminous Flux Spec. Table Flux (lm) at IF = 20mA IV Bin lm Min. Max. 101 1900 2000 111 2000 2100 121 2100 2200 131 2200 2300 141 2300 2400 151 2400 2500 161 2500 2600 Tolerance on each Luminous Flux bin is +/- 7% 5/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 Color Ranks Table Color bin limits at IF = 20mA Ranks CIE 1931Chromaticity coordinates C12 C21 C22 C31 C32 B12 B21 B22 B31 B32 x 0.265 0.270 0.270 0.265 y 0.237 0.245 0.258 0.250 x 0.270 0.275 0.275 0.270 y 0.245 0.253 0.266 0.258 x 0.275 0.280 0.280 0.275 y 0.253 0.261 0.274 0.266 x 0.280 0.285 0.285 0.280 y 0.261 0.269 0.282 0.274 x 0.285 0.290 0.290 0.285 y 0.269 0.277 0.290 0.282 x 0.265 0.270 0.270 0.265 y 0.224 0.232 0.245 0.237 x 0.270 0.275 0.275 0.270 y 0.232 0.240 0.253 0.245 x 0.275 0.280 0.280 0.275 y 0.240 0.248 0.261 0.253 x 0.280 0.285 0.285 0.280 y 0.248 0.256 0.269 0.261 x 0.285 0.290 0.290 0.285 y 0.256 0.264 0.277 0.269 Tolerance on each Hue (x, y) bin is +/- 0.007. 6/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 Lite-ON Color BIN Graph 7/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 Typical Electrical / Optical Characteristics Curves (25C Ambient Temperature Unless Otherwise Noted) 8/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 User Guide Cleaning Do not use unspecified chemical liquid to clean LED they could harm the package. If cleaning is necessary, immerse the LED in ethyl alcohol or isopropyl alcohol at normal temperature for less than one minute. Recommend Printed Circuit Board Attachment Pad Infrared / vapor phase Reflow Soldering Package Dimensions of Tape Note: All dimensions are in mm. 9/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 Package Dimensions of Reel Notes: 1. Empty component pockets sealed with top cover tape. 2. 7 inch reel- maximum 2000 pieces per reel. 3. Minimum packing quantity is 500 pieces for remainders. 4. The maximum number of consecutive missing lamps is two. 5. In accordance with EIA-481-1-E2 specifications. 10/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 CAUTIONS 1. Application The LEDs described here are intended to be used for ordinary electronic equipment (such as office equipment, communication equipment and household applications).Consult Liteon's Sales in advance for information on applications in which exceptional reliability is required, particularly when the failure or malfunction of the LEDs may directly jeopardize life or health (such as in aviation, transportation, traffic control equipment, medical and life support systems and safety devices). 2. Storage This product is qualified as Moisture sensitive Level 3 per JEDEC J-STD-020 Precaution when handing this moisture sensitive product is important to ensure the reliability of the product. The package is sealed: The LEDs should be stored at 30C or less and 90%RH or less. And the LEDs are limited to use within one year, while the LEDs is packed in moisture-proof package with the desiccants inside. The package is opened: The LEDs should be stored at 30C or less and 60%RH or less. Moreover, the LEDs are limited to solder process within 168hrs. If the Humidity Indicator shows the pink color in 10% even higher or exceed the storage limiting time since opened, that we recommended to baking LEDs at 60C at least 48hrs. To seal the remainder LEDs return to package, it's recommended to be with workable desiccants in original package. 3. Cleaning Use alcohol-based cleaning solvents such as isopropyl alcohol to clean the LED if necessary. 4. Soldering Recommended soldering conditions: Reflow soldering Soldering iron Pre-heat 120~150C Temperature 300C Max. Pre-heat time 120 sec. Max. Soldering time 3 sec. Max. Soldering Temp. Soldering time 260C Max. (one time only) 30 sec. Max. 11/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 5. Drive Method An LED is a current-operated device. In order to ensure intensity uniformity on multiple LEDs connected in parallel in an application, it is recommended that a current limiting resistor be incorporated in the drive circuit, in series with each LED as shown in Circuit A below. Circuit model A Circuit model B LED LED (A) Recommended circuit. (B) The brightness of each LED might appear different due to the differences in the I-V characteristics of those LEDs. 6. ESD (Electrostatic Discharge) Static Electricity or power surge will damage the LED. Suggestions to prevent ESD damage: Use of a conductive wrist band or anti-Electrostatic glove when handling these LEDs. All devices, equipment, and machinery must be properly grounded. Work tables, storage racks, etc. should be properly grounded. Use ion blower to neutralize the static charge which might have built up on surface of the LED's plastic lens as a result of friction between LEDs during storage and handling. ESD-damaged LEDs will exhibit abnormal characteristics such as high reverse leakage current, low forward voltage, or " no lightup " at low currents. To verify for ESD damage, check for " lightup " and Vf of the suspect LEDs at low currents. The Vf of " good " LEDs should be >2.0V@0.1mA for InGaN product 12/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 7.1 Reliability Test Number of Test Item Test Condition Reference Standard Note Damaged Resistance to Soldering JEITA ED-4701 Tsld=260, 10sec. Heat (Reflow Soldering) 2 times 0/50 300 301 Solderability Tsld=2455, 3sec. (Reflow Soldering) (Lead Free Solder) JEITA ED-4701 1 time 300 303 Over 95% 0/50 -30 ~ 85 JEITA ED-4701 Thermal Shock 100 cycles 0/50 100 cycles 0/50 1000 hrs. 0/50 1000 hrs. 0/50 1000 hrs. 0/50 Ta=25, IF=20mA 1000 hrs. 0/50 Ta=25, IF=30mA 500 hrs. 0/50 Ta=85, IF=5mA 1000 hrs. 0/50 60, RH=90% , IF=15mA 500 hrs. 0/50 Ta=-30, IF=20mA 1000 hrs. 0/50 30min. 30min. 300 307 -40 ~ 25 ~ 100 ~ 25 JEITA ED-4701 Temperature Cycle 30min. 5min. 30min. 5min. 100 105 JEITA ED-4701 High Temperature Storage Ta=100 200 201 JEITA ED-4701 Temperature Humidity Storage Ta=60, RH=90% 100 103 JEITA ED-4701 Low Temperature Storage Ta=-40 200 202 Steady State Operating Life Condition 1 Steady State Operating Life Condition 2 Steady State Operating Life of High Temperature Steady State Operating Life of High Humidity Heat Steady State Operating Life of low Temperature 13/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4 Specific Lighting LTW-006DCG-E2 7.2 Criteria for Judging the Damage Item Symbol Test Conditions Forward Voltage VF Luminous Intensity IV Criteria for Judgment Min. Max. IF=20mA - U.S.L. 1.1 IF=20mA U.S.L. 0.7 - 8. Others The appearance and specifications of the product may be modified for improvement without prior notice. 9. Suggested Checking List Training and Certification 1. Everyone working in a static-safe area is ESD-certified? 2. Training records kept and re-certification dates monitored? Static-Safe Workstation & Work Areas 1. Static-safe workstation or work-Sreas have ESD signs? 2. All surfaces and objects at all static-safe workstation and within 1 ft measure less than 100V? 3. All ionizer activated, positioned towards the units? 4. Each work surface mats grounding is good? Personnel Grounding 1. Every person (including visitors) handling ESD sensitive (ESDS) items wear wrist strap, heel strap or conductive shoes with conductive flooring? 2. If conductive footwear used, conductive flooring also present where operator stand or walk? 3. Garments, hairs or anything closer than 1 ft to ESD items measure less than 100V*? 4. Every wrist strap or heel strap/conductive shoes checked daily and result recorded for all DLs? 5. All wrist strap or heel strap checkers calibration up to date? Note: *50V for Blue LED. Device Handling 1. Every ESDS items identified by EIA-471 labels on item or packaging? 2. All ESDS items completely inside properly closed static-shielding containers when not at static-safe workstation? 3. No static charge generators (e.g. plastics) inside shielding containers with ESDS items? 4. All flexible conductive and dissipative package materials inspected before reuse or recycle? Others 1. Audit result reported to entity ESD control coordinator? 2. Corrective action from previous audits completed? 3. Are audit records complete and on file? 14/14 Part No. : LTW-006DCG-E2 BNS-OD-FC002/A4