VARISPEED E7Z IP54 INVERTER Built for the toughest conditions Sealed to stringent IP54 sta n d a rd S t u rd y m e t a l h o u s i n g On-board PLC functionality and intelligence Advanced Industrial Automation Rugged & reliable standalone pump and fan inverter Omron's E7Z IP54 is a true work-anywhere pump and fan inverter that will survive virtually anything you care to throw at it. A rugged metal housing and ventilation system meeting the stringent IP54 standard provides outstanding protection from non- Inside the E7Z IP54's tough exterior lies a world of advanced technology offering you a host of new possibilities. Like CASE (customised application software) for customised control without need of any extra option boards. Like PLC functionality that provides on-board intelligence for standalone applications independent of an external controller. Or like communication with external world allowing you to fully control operation remotely from your standalone application. conductive dust and splash damage. Maintaining the inverter electronics in a controlled environment and guaranteeing long, trouble-free operation. E7 IP54 benefits The work-anywhere inverter: Extreme tough metal housing * Reliable operation even in the harshest conditions thanks to IP54 housing * Easy cable connections thanks plenty of space inside housing * Screw-mountable anywhere within your plant * Easy viewing of inverter states with ruggedized LCD front panel * Conforms to EMC requirements thank to the unit's built-in Digital operator panel industrial filter * Minimised harmonic distortion with 12-pulse input * Silent operation with no need for current de-rating in silent mode With intelligence on-board: * PLC functionality for standalone operation with optional PLC card * Simple, direct connection to high-level control systems via Modbus, DeviceNet, ProfiBUS, CANopen and HVAC Fieldbus Lots of space inside for easy wiring * Inverter Customised application software avoiding the use of external controllers * Optimum economy with advanced energy-saving algorithm Solid wall mount panel Easy door lock only two screws Bottom view Intrusion sensing detector Compobus S Water level detector PLC Option board Designed from one viewpoint... yours! A new world of possibilities with PLC functionality Customised application software fully adaptable to your needs * Distributed I/Os for standalone operation Our software engineers are in continuous contact with You can allocate up to 256 I/Os (digital or analogue) controlled customers - discovering their needs and refining special via Omron's Compobus Network. These allow you to connect software to meet them. As a result, E7Z inverter software is fully a broad range of sensors Giving you total independence from customisable to your requirements. your main control room. * Built-in pump sequencer ensures optimum pump action * Dnet communications Providing optimum control and economy, the built-in pump The PLC option board provides communication with the outside sequencer automatically switches-in auxiliary pumps to support world thanks to the Dnet slave availability. the main (PID-controlled modulated) pump to meet increased flow demand. It also provides automatic auxiliary-pump cycling * Wired or GSM connectivity for balanced operation. You can gather all the information you need to monitor and Other important features include: manage your installation from your PC or arrange alarms and * Pressure feedback signal: 0 - 10 V sensor, 0 - 20 mA warnings to be transmitted to your mobile phone. * 4 - 20 mA OR inverted sensor * Modulated pump automatic frequency drop and rise * Settings easily updated with HMI * Specific fault and alarm messages Via the PLC option board serial port, you can easily update your *Pump override eliciting automatic/manual emergency settings and get information locally through an HMI terminal. mode-operation * Test operation Advanced Industrial Automation CIMR-E7Z Varispeed E7 Frequency inverter for pumps and fans * Energy saving function. * Advanced PID controller with dedicated HVAC functions. * 12 pulse operation for harmonics reduction. * Speed search. * Standard RS-485 communication - MODBUS. * Optional network cards (DeviceNet, PROFIBUS, CANOpen, LONWORKS). * CE, UL, and cUL marked and Germanischer Lloyds approval. * Embedded OMRON PLC functionality with PLC option card * PC configuration tool CX-drive. * CE, UL, and cUL marked and Lloyds approval. E7IP54 * Robust metal chassis. * LCD operator. * Built in RFI filter. Customized software * The inverter software can be customized to meet specific application. Examples: * Pump sequencer (S-8801). *For detailed information please refer to CASE software section. Ratings * 200 V Class 0.4 to 110 kW. * 400 V Class 0.4 to 300 kW. System configuration 3G3IV-PCN329-E Inverter to PC cable CX-Drive JVOP-160 OY Digital operator (LCD display) JVOP-161-OY Digital operator (LED display) Line filter 3G3IV-PCN126/326 Digital operator extension cable Braking accessories * see note Varispeed E7 LKEB_ braking resistor unit CDBR_B braking unit * E7 IP54 types are built-in filter inverters. PLC option card T1 JP3 Communication card JP1 U6 C3 R28 C28 R8 R120 U1 TR2 + R75 R114 C17 R14 U14 R21 R5 R25 R15 R15 R15 + 2 + R55 R54 R56 R57 R40 R39 R78 R6 D6 C39 C5 R20 R30 C35 R99 U12 R95 R7 R131 TR1 C2 Y1 C22 11 R11 R110 R107 R70 U10 U8 C24 U11 C16 R113 R5 C21 R3 R36 R35 U10 U7 C1 R R1 R2 C33 + + U9 R11 C26 R6 R52 PE U15 R10 R10 R10 5 C11 R102 C12 JP5 C13 JP6 R95 RT4 R94 R97 C20 R96 U13 U17 COD E No. 4 Varispeed E7 SI-N 736 C10 00C02 10 Varispeed E71 Type designation CIMR - E7 Z 4 0P4 0 Inverter Protective enclosure 0: Open chassis type (IP00) 1: Enclosed type (IP20 / NEMA 1) 2: Enclosed type (IP54) E7 series Specifications Z: European standard specifications Max. applicable motor output 0P4: 0.4 kW ~ Voltage 2: 200 V class 4: 400 V class ~ 022: 22 kW 300: 300 kW [ "P" indicates a decimal point ] 200 V class Model CIMR-E7Z@ 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 Max. applicable motor output1 Output characteristics Inverter capacity kVA Power supply Rated current 2. 2018 2022 2030 2037 2045 2055 2075 2090 2110 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 1.2 1.6 2.7 3.7 5.7 8.8 12 17 22 27 32 44 55 69 82 110 130 160 3.2 4.1 7.0 9.6 15 23 31 45 58 71 85 115 145 180 215 283 346 A 415 Max. voltage 3-phase; 200, 220, 230, or 240 VAC (proportional to input voltage) Max. output frequency 200.0 Rated input voltage and frequency 3-phase, 200/208/220/230/240 VAC, 50/60 Hz Allowable voltage fluctuation + 10%, - 15% Allowable frequency fluctuation 5% Harmonic wave prevention 1. 2015 0.75 0.55 Kw DC reactor Optional Built in 12-pulse input Not possible Possible*2 Standard 4-pole motors are used for max. applicable motor output. Choose the inverter model whose rated current is allowable within the motor rated current range. A 3-wire transformer is required on the power supply for 12-phase rectification. 400 V class Model CIMR-E7ZZ@ 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 IP54 model: CIMR-E7Z Power supply Output characteristics Max. applicable motor output1 --- --- --- --- --- 47P52 40112 40152 40182 40222 40302 40372 40452 40552 --- --- Kw 0.55 0.75 1.5 --- --- 2.2 3.7 4.0 5.5 7.5 11 15 18.5 22 30 37 45 90 9.5 --- --- --- --- 110 132 160 185 220 300 110 140 160 200 230 280 390 510 1.6 2.8 4.0 5.8 6.6 13 18 24 30 34 46 57 69 85 1.8 2.1 3.7 5.3 7.6 8.7 12.5 17 24 31 39 45 60 75 91 112 150 180 216 260 304 370 506 675 A Max. voltage 3-phase; 380, 400, 415, 440, 460, or 480 VAC (proportional to input voltage) Max. output frequency 200.0 Rated input voltage and frequency 3-phase, 380, 400, 415, 440, 460 or 480 VAC, 50/60 Hz Allowable voltage fluctuation + 10%, - 15% Allowable frequency fluctuation 5% Harmonic wave prevention 2. * --- 75 Inverter capacity kVA 1.4 Rated current 1. --- 55 DC reactor Optional Built in 12-pulse input Not possible Possible*2 Standard 4-pole motors are used for max. applicable motor output. Choose the inverter model whose rated current is allowable within the motor rated current range. A 3-wire transformer is required on the power supply for 12-phase rectification To agg 400 V class Frequency inverters 2 5 Frequency inverters Enclosures 200 V class Model CIMR-E7Z@ Available as standard Open chassis type (IEC IP00) Available by removing the upper and lower cover of enclosed type Model CIMR-E7Z@ 400 V class 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 Enclosed type (IEC IP20) Available for option Not available Available as standard 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 Enclosed type (IEC IP20) Available as standard Open chassis type (IEC IP00) Available by removing the upper and lower cover of enclosed type Enclosed type (IP54) --------------------- Available for option Not available Available as standard Available as standard ---------------------- Commom specifications Model Number CIMR-E7Z@ Protective functions Control characteristics Control method Speed control range 1:40 Speed control accuracy 3 (25 C 10 C) Frequency control range 0.0to 200.0 Hz Frequency accuracy (temperature characteristics) Digital references: 0.01% (-10 C to +40 C) Frequency setting resolution Analog references: 0.1% (25 C 10 C) Digital references: 0.01 Hz Analog references: 0.025/50 Hz (11 bits plus sign) Output frequency resolution 0.01 Hz Frequency setting signal 0 to +10 V, 4 to 20 mA Accel/decel time 0.01 to 6000.0 s (2 selectable combinations of independent acceleration and deceleration settings) Braking torque Approximately 20% Main control functions Restarting for momentary power loss, speed searches, overtorque detection, 5-speed control (maximum), acceleration/deceleration time changes, S-curve acceleration, 3-wire control, autotuning, cooling fan ON/OFF control, torque compensation, jump frequencies, upper and lower limits for frequency references, DC braking for starting and stopping, high-slip braking, PI control (with sleep function), energy-saving control, MEMOBUS communications (RS-485/422, 19.2 kbps maximum), fault reset, and copy function. Motor protection Protection by electronic thermal overload relay. Instantaneous overcurrent protection Stops at approx. 200% of rated output current. Fuse blown protection Stops for fuse blown. Overload protection 120% of rated output current for 1 minute Overvoltage protection 200 class inverter: stops when main-circuit DC voltage is above 410 V. 400 class inverter: stops when main-circuit DC voltage is above 820 V. Undervoltage protection 200 class inverter: stops when main-circuit DC voltage is below 190 V. 400 class inverter: stops when main-circuit DC voltage is below 380 V. Momentary power loss ride through By selecting the momentary power loss method, operation can be continued if power is restored within 2 s. Cooling fin overheating Protection by thermistor. Stall prevention Stall prevention during acceleration, deceleration, or running. Grounding protection Protection by electronic circuits. Charge indicator Lights up when the main circuit DC voltage is approx. 50 V or more. Protective structure Environment Specification Sine wave PWM V/f control Ambient operating temperature Enclosed wall-mounted type (NEMA 1): 18.5 kW or less (same for 200 V and 400 V class inverters) Open chassis type (IP00): 22 kW or more (same for 200 V and 400 V class inverters) Enclosed wall-mounted type (IP54): From 7.5 Kw to 55 Kw (400 V class inverters) -10 C to 40 C (enclosed wall-mounted type) - 10 C to 45 C (open chassis type) Ambient operating humidity 95% max. (with no condensation) Storage temperature - 20 C to + 60 C (short-term temperature during transportation) Application site Indoor (no corrosive gas, dust, etc.) Altitude 1000 m max. Vibration 10 to 20 Hz, 9.8 m/s2 max.; 20 to 50 Hz, 2 m/s2 max 6 Varispeed E7 Varispeed E73 Dimensions Open chassis type (IEC IP00) W1 H H2 H1 4-d (5) (5) W (5) D T1 D1 Fig 1 400 V class (3-phase) 200 V class (3-phase) Voltage Max. applicable motor Inverter output kW CIMR-E7Z@ 0.4 ---- 0.75 ---- 1.5 ---- 2.2 ---- 3.7 ---- 5.5 ---- 7.5 ---- 11 ---- 15 ---- Fig Dimensions in mm W H ---- 22 2022 0 250 400 30 2030 0 275 450 37 2037 0 45 2045 0 375 600 55 2055 0 75 2075 0 450 725 90 2090 0 500 110 2110 0 575 0.4 ---- 0.75 ---- 1.5 ---- 2.2 ---- 4.0 ---- 5.5 ------- 11 ---- 15 ---- 18.5 ---- 22 4022 0 30 4030 0 37 4037 0 45 4045 0 55 4055 0 75 4075 0 90 4090 0 110 4110 0 132 4132 0 160 4160 0 185 4185 0 220 4220 0 300 4300 0 Frequency inverters 4 W1 H1 H2 D1 T1 d Approx. weight kg Cooling method Not available, please use the IP20 type removing the upper and lower cover 18.5 7.5 D 195 385 220 435 250 575 348 325 700 850 358 370 820 885 378 445 855 3 258 298 328 7.5 100 2.3 M6 21 24 100 12.5 57 3.2 63 M10 86 130 15 140 Fan cooled 87 4.5 108 M12 150 Not available, please use the IP20 type removing the upper and lower cover 275 450 258 220 435 325 550 283 260 535 450 725 348 325 700 100 7.5 3 21 2.3 M6 105 12.5 36 3.2 M10 130 500 850 358 370 820 15 575 916 378 445 855 45.8 140 710 1305 413 540 1270 15 125.5 916 1475 413 730 1440 88 89 102 Fan cooled 120 4.5 M12 160 260 280 405 7 Frequency inverters Enclosed type (IEC IP20) E7Z 20P41 to E7Z25P51 E7Z 27P51 to E7Z20181 E7Z 20221 to E7Z20751 E7Z40P41 to E7Z45P51 E7Z47P51 to E7Z40181 E7Z40221 to E7Z41601 200 V class (3-phase) 0.4 400 V class (3-phase) Fig H1 (5) W H D 4 W1 (5) D Fig 3 Dimensions in mm W H0 H H2 H (5) D Fig 2 Max. applicable motor Inverter output kW CIMR-E7Z@ 8 Varispeed E7 3 T1 D1 H10 W D D1 H3 H1 H2 W1 Fig 1 Voltage 4-d T1 T1 D1 H3 3 W1 H0 H H0 4 H2 W 4-d 4-d H1 W1 H0 H1 H2 H3 D1 T1 d Approx. weight kg Cooling method 3 Self cooled 20P4 1 0.75 20P7 1 1.5 21P5 1 2.2 22P2 1 3.7 23P7 1 5.5 25P5 1 7.5 27P5 1 11 2011 1 15 2015 1 18.5 2018 1 157 1 140 200 2 240 22 2022 1 30 2030 1 279 37 2037 1 45 2045 1 55 2055 1 75 2075 1 0.4 40P4 1 0.75 40P7 1 1.5 41P5 1 42P2 1 3.7 43P7 1 4.0 44P0 1 5.5 45P5 1 7.5 47P5 1 11 4011 1 15 4015 1 18.5 4018 1 22 4022 1 30 4030 1 37 4037 1 45 4045 1 55 4055 1 75 4075 1 90 4090 1 110 4110 1 132 4132 1 160 4160 1 126 280 266 7 --- 177 254 2.2 280 39 3 380 453 300 310 350 380 535 615 809 1027 300 285 207 216 350 335 195 400 385 220 450 435 165 250 600 575 209 328 348 8 0 186 298 10 0 7.5 30 12.5 325 725 700 140 280 302 300 126 197 6 65.5 78 7 2.3 M6 280 266 7 186 300 285 100 Fan cooled 27 62 130 3.2 M10 68 94 95 --- 8 2 11 24 39 177 200 4 135 157 1 M5 59 197 258 5 3 5 Self cooled M5 59 4 65.5 6 78 10 --240 350 207 216 350 335 275 535 258 220 450 435 325 715 283 260 550 535 453 1027 348 325 725 700 7.5 85 105 100 2.3 M6 105 302 3.2 M10 130 504 1243 358 370 850 820 15 393 579 1324 378 445 918 855 45.8 408 96 97 122 4.5 140 Fan cooled 40 3 12.5 24 M12 130 170 Varispeed E75 Enclosed wall-mounted inverters (IP54 type) D W1 4-d H1 H W Max. applicable motor Inverter output kW CIMR-E7Z@ 400 V class (3-phase) Voltage 7.5 47P52 11 40112 15 40152 18.5 40182 22 40222 30 40302 37 40372 45 40452 55 40552 H2 t1 Dimensions in mm W H D W1 H1 H2 T1 d 240 350 600 Approx. weight (kg) 25 260 576 9 2.5 M8 260 30 410 650 300 370 620 12 2.5 M10 43 580 750 330 410 714 11 2.5 M14 71 Heat loss (W) Cooling method 304 427 536 662 754 Fan 989 1145 1317 1701 Component names Inverter enclosure Digital operator Wall mount Motor output Door locks Power input (plastic gland) (7.5 kW to 30 kW: metal gland) (37 kW to 55 kW: plastic gland) Name plate Control Field bus (option) Door Mounting holes Cable entry plate Accessories Following parts are delivered in the package with the inverter. Part name Qty Cable gland (for input)* 1 Cable gland (for motor ouput)* 1 Cable gland (for control)* 1 Cable gland (for fieldbus)* 1 Door key 1 Blind plug (control cable entry) 1 Blind plug (fieldbus cable entry) 1 * Locknuts for each cable gland are also supplied. Frequency inverters 6 9 Frequency inverters Filters Dimensions Model 200 V 400 V A B C D E F G H I J K L 3G3RV-PFI2035-SE 330 141 46 281 313 115 5.5 M5 23 126 266 M5 3G3RV-PFI2060-SE 355 206 60 302 336 175 6.5 M6 30 186 285 M6 3G3RV-PFI2100-SE 408 236 80 355 390 205 6.5 M6 40 216 335 M6 3G3RV-PFI3010-SE 330 141 46 281 313 115 5.5 M4 23 126 266 M5 3G3RV-PFI3018-SE 330 141 46 281 313 115 5.5 M4 23 126 266 M5 3G3RV-PFI3035-SE 355 206 50 302 336 175 6.5 M5 25 186 285 M6 3G3RV-PFI3060-SE 408 236 65 355 390 205 6.5 M6 32.5 216 335 M6 A B C D E F G H 310 180 90 280 295 65 6.5 M10 Model 200 V 400 V 10 Varispeed E7 3G3RV-PFI2130-SE Dimensions 3G3RV-PFI2160-SE 380 170 120 350 365 102 6.5 M10 3G3RV-PFI2200-SE 518 240 130 480 498 90 8.2 M10 3G3RV-PFI3070-SE 329 185 80 300 314 55 6.5 M6 3G3RV-PFI3130-SE 310 180 90 280 295 65 6.5 M10 3G3RV-PFI3170-SE 380 170 120 350 365 102 6.5 M10 3G3RV-PFI3200-SE 518 240 130 480 498 90 8.3 M10 3G3RV-PFI3400-SE 386 115 260 306 240 235 12.0 M12 3G3RV-PFI3600-SE 386 135 260 306 240 235 12.0 M12 3G3RV-PFI3800-SE 564 160 300 516 420 275 9.0 M12 Varispeed E77 Braking unit dimensions 30 or more Lead wire inlet (28 dia. rubber bush) 2-lead wire inlet (35 dia. rubber bush) 104 100 59 50 111 156 200 30 or more 140 180 Weight 1.8 Kg 100 or less 3-lead wire inlet (20 dia. rubber bush) 73 138.5 100 or less Main circuit terminal M6 114.5 30 or more 4-M6 MTG holes 140 370 350 317 38 128 140 100 or more 38 30 or more 66.5 150 138 72 12 36.5 4-M4 MTG holes Model CDBR-2110 B 100 or more Model CDBR-2015 B, -2022 B, -4030B, -4045 B Weight 8.5 Kg Main circuit terminal M6 104 Lead wire inlet (28 dia. rubber bush) 2-lead Wire Inlet (35 dia. rubber bush) 156.5 118.5 50 111 156 200 30 or more 210 250 100 or more 70 30 or more 100 or more 4-M6 MTG holes 210 355 317 370 9 36.5 Model CDBR-4220 B Weight 12 Kg 200 or more Braking resistor unit (separately-installed type) dimensions MTG screw 150 or more 30 or more Model Voltage LKEB-_ 220 V class 400 V class 30 or more A C 50 or more A 50 or more 260 150 Dimensions in mm A B C D MTG screw Weight kg 20P7 105 275 50 260 M5 x 3 3.0 21P5 130 350 75 335 M5 x 4 4.5 22P2 130 350 75 335 M5 x 4 4.5 23P7 130 350 75 335 M5 x 4 5.0 25P5 250 350 200 335 M6 x 4 7.5 25P5 250 350 200 335 M6 x 4 8.5 40P7 105 275 50 260 M5 x 3 3.0 41P5 130 350 75 335 M5 x 4 4.5 42P2 130 350 75 335 M5 x 4 4.5 43P7 130 350 75 335 M5 x 4 5.0 45P5 250 350 200 332 M6 x 4 7.5 47P5 250 350 200 332 M6 x 4 8.5 Frequency inverters 8 Voltage 220 V class 400 V class 200 or more C B D B D 150 or more MTG screw Dimensions in mm Model LKEB@ A B C D MTG screw Weight kg 2011 266 543 246 340 M8 x 4 10 2015 356 543 336 340 M8 x 4 15 2018 446 543 426 340 M8 x 4 19 2022 446 543 426 340 M8 x 4 19 4011 350 412 330 325 M6 x 4 16 4015 350 412 330 325 M6 x 4 18 4018 446 543 426 340 M8 x 4 19 4022 446 543 426 340 M8 x 4 19 4030 356 956 336 740 M8 x 4 25 4037 446 956 426 740 M8 x 4 33 4045 446 956 426 740 M8 x 4 33 11 Frequency inverters Attachments Heatsink external mounting attachment The Varispeed E7 inverters under the 200/400 V class 18.5 kW or less need this attachment for mounting the heatsink externally. This attachment expands the outer dimensions of the width and height of the inverter. (Attachment is not required for inverters of 22 kW or more.) Model CIMRE7Z@ 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 Wall H1 H Mounting panel W1 W D1 D2 D3 or more Dimensions in mm Attachment order code W H W1 H1 EZZ08676A 155 302 126 290 122.6 D1 D2 D3 37.4 40 57.4 60 EZZ08676B 210 330 180 316 136.1 63.4 70 EZZ08676C 250 392 216 372 133.6 76.4 85 37.4 40 57.4 60 EZZ08676A 155 302 126 290 122.6 EZZ08676B 210 330 180 316 136.1 63.4 70 EZZ08676C 250 392 216 372 133.6 76.4 85 2-5 Dia. holes b a 4-d Tap a a a W1 (W2) Fig 1 (H3) a Fig 3 (W3) a W1 W Fig 2 (H3) (H2) (W2) H H1 B A a W1 W (H2) a a (W2) a 4-d Tap (W2) (W3) (59) W (W3) A (H3) b (W3) (H3) a H1 H (W3) (W2) A (H2) (W3) (W2) B H1 H B (19) (H2) a (H3) 4-d Tap (H3) Panel cut for external mounting of cooling fin (heatsink) Model CIMRE7Z@ 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 1. 12 Varispeed E7 Drawing W Dimensions in mm H W1 (W2) (W3) H1 (H2) (H3) 155 302 126 6 A B d 8.5 290 9.5 6 138 271 M5 6.5 316 7 197 298 8.5 372 9.5 10 233 353 M6 385 435 8 7.5 244 369 269 419 575 15 1 210 330 180 9 8.5 250 392 216 250 400 195 24.5 275 450 220 3 375 600 250 54.5 2 8 450 725 325 359 545 12.5 700 13.5 M10 434 673 500 850 370 575 885 445 57 55 8 10 820 855 19 15 484 782 M12 555 817 155 302 126 6 8.5 290 9.5 6 138 271 M5 6.5 316 7 197 298 250 392 216 8.5 372 9.5 10 233 353 275 450 220 3 435 325 550 260 8 535 450 725 325 54.5 8 700 13.5 12.5 434 673 M10 1 210 330 180 9 8.5 24.5 M6 269 419 8 7.5 309 519 2 3 500 850 370 57 8 820 19 15 484 782 575 925 445 55 10 895 1 15 555 817 M12 The sizes are different between the top and the bottom. Refer Fig 3 Varispeed E79 Installation Standard connections DC reactor to improve input power factor (optional) U X Short-circuit bar 1 Main contactor 2 Varispeed E7 Fuse 3-phase power supply 380 to 480 V 50/60 Hz L1 R/L1 L2 CIMRE7Z47P5 S/L2 Line filter* L3 Motor U/T1 T/L3 M V/T2 W/T3 PE Multi-function digital inputs [Factory settings] MA Forward run/stop S1 Reverse run/stop S2 External fault S3 Fault reset S4 M1 Multi-step speed setting 1 S5 M2 Multi-step speed setting 2 S6 M3 MB Jog frequency selection MC M4 S7 Fault contact output 250 VAC, 1 A max. 30 VDC, 1 A max. Contact output 1 [Default: During run] Multi-function digital output 250 VAC, 1 A max. 30 VDC, 1 A max. Contact output 2 [Default: Zero speed] SN SC SP 24 V E(G) Adjustment 3 2 k 1 E(G) Adjustment, 20 k A1 Analog input 1: Master frequency reference 0 to 10 V (20 k) 2 A2 Multi-function analog input 1: [Default: Frequency Bias 4 to 20 mA (250 )] AC 4 to 20 mA P Shield terminal +V Analog input power supply +15 V, 20 mA 2 k 0 to 10 V Shield terminal P -V 0V Analog input power supply -15 V, 20 mA FM + - Multi-function analog output 1 (0 to 10 V, 2 mA) [Default: Output frequency, 0 to 10 V] - Multi-function analog output 2 (0 to 10 V, 2 mA) [Default: Output power, 0 to 10 V] FM Adjustment, 20 k AM + AM AC Terminating resistance R+ P MEMOBUS communication RS-485/422 RS+ P SIG Shielded wires P Twisted-pair shielded wires *E7 IP54 types has RFI filter included as standard Frequency inverters 10 13 Frequency inverters Main circuit Voltage 200 V 400 V Model CIMR-E7Z@ 20P4 to 2018 2022, 2030 2037 to 2110 40P4 to 4018 4022 to 4055 4075 to 4300 Max. applicable motor output 0.4 to 18.5 kW 22 to 30 kW 37 to 110 kW 0.4 to 18.5 kW 22 to 55 kW 75 to 300 kW R/L1 Main circuit input power supply S/L2 T/L3 Main circuit input power supply R1/L11 S1/L21 Main circuit input power supply R-R1, S-S1 and T-T1 have been wired before shipment (see P59). --- Main circuit input power supply R-R1, S-S1 and T-T1 have been wired before shipment --- T1/L31 U/T1 V/T2 Inverter output Inverter output W/T3 2 DC reactor ( 1- 2) DC power supply1 ( 1- ) 3 --- 1 /l2 200 / l2 200 3. Ground terminal (100 or less) ) DC power supply ( 1- 2)1 Braking unit ( 3- ) ------- ------ 400 / l2 400 1. 2. DC reactor ( 1- 2) DC power supply1 ( 1- ) Cooling fan power supply2 ------ r/l1 PE ( DC power supply ( 1- 2)1 Braking unit ( 3- ) 1 - DC power input does not conform to UL/c-UL listed standard. Cooling fan power supply r/l1- /l2: 200 to 220 VAC 50 Hz, 200 to 230 VAC 60 Hz (A transformer is required for 230 V 50 Hz or 240 V 50/60 Hz power supply.) Cooling fan power supply r/l1 - 200 / l2 200: 200 to 220 VAC 50 Hz, 200 to 230 VAC 60 Hz, r/l1 - Cooling fan power supply3 Ground terminal (10 or less) 400 / l2 400: 380 to 480 VAC 50/60 Hz Main circuit configuration CIMR-E7Z20P4 to 2018 CIMR-E7Z2037 to 2110 200 V class CIMR-E7Z2022, 2030 CIMR-E7Z4022 to 4055 CIMR-E7Z47P5 to 40182 CIMR-E7Z40222 to 40552 CIMR-E7Z4075 to 4300 400V class IP54 400 V class CIMR-E7Z40P4 to 4018 1 2 R/L1 S/L2 T/L3 U/T1 V/T2 W/T3 EMC filter 14 Varispeed E7 Power supply Control circuits Varispeed E7 11 Control circuit Analog input signals Digital input signals Type No. Signal name Function S1 Forward run/stop command Forward run when ON; stopped when OFF. S2 Reverse run/stop command Reverse run when ON; stopped when OFF. S3 External fault input*1 Fault when ON. S4 Fault reset*1 Reset when ON S5 Multi-step speed reference 1*1 (Master/auxiliary switch) S6 Multi-step speed reference 2*1 Multi-step setting 2 when ON. S7 Jog frequency reference*1 Jog frequency when ON. SC Digital input common - SN Digital input neutral - - SP Digital input power supply +24 VDC power supply for digital inputs 24 VDC, 250 mA max. *2 +V 15 V power output 15 V power supply for analog references 15 V (max. current: 20 mA) A1 Frequency reference 0 to +10 V/100% A2 Multi-function analog input Digital output signals - 4 to 20 mA/100% 0 V to +10 V/100% 0 to 20 mA/100% 0 to +10 V (20 k) Function is selected by setting H3-09. 4 to 20 mA (250 ) 0 V to +10 V (20 k) 0 to 20 mA (250 ) Analog reference common - - Shield wire, optional ground line connection point - - Running signal (1NO contact) M2 Operating when ON. Multi-function contact outputs M3 Zero speed Zero level (b2-01) or below when ON M4 MA FM Multi-function analog output (frequency output) AC Analog common AM Multi-function analog output (current monitor) R+ RS+ S- 0 to 10 V, 10 V=100% output frequency Multi-function analog output 1 - 0 to 10 V, 10V = 200% of the inverter rated current For 2-wire RS-485, short R+ and S+ as well as R- and S-. MEMOBUS communications output Signal common 0 to +10 V max. 5% 2 mA max. Multi-function analog output 2 MEMOBUS communications input IG Relay contacts contact capacity: 1 A max. at 250 VAC 1 A max. at 30 VDC*3 Fault when CLOSED across MA and MC Fault when OPEN across MB and MC Fault output signal MB Analog output signals 24 VDC, 8 mA photocoupler isolation AC MC RS-485/422 Auxiliary frequency reference when Functions are selected by setting H1-01 to H1-05. ON. E(G) M1 Note: Signal level Differential input, photocoupler isolation Differential input, photocoupler isolation - - 1.The default settings are given for terminals S3 to S7. For a 3-wire sequence, the default settings are a 3-wire sequence for S5, multi-step speed setting 1 for S6 and multi-step speed setting 2 for S7. 2.Do not use this power supply for supplying any external equipment. 3.When driving a reactive load, such as a relay coil with DC power supply, always insert a flywheel diode. Remove the upper and lower covers for the models of 15 kW or less in 200 V and 400 V classes. Internal heatsink 55 C Upper cover Upper cover Upper part air temperature -10 to 55 C When using open chassis type inverters of 200 V/400 V 22 kW or more, secure spaces for eyebolts and wiring of the main circuit. 50 mm or more 120 mm or more Air Heatsink Heatsink Open chassis type inverter Lower cover Inverter inlet temperature -10 to 45 C 45 C Peripheral temperature 40 C 30 mm or more 50 mm or more Lower cover Side spaces 30 mm or more 120 mm or more Air Top and bottom spaces Cover MTG screw Frequency inverters 12 15 Frequency inverters Inverter heat loss 200 V class Model CIMR-E7Z@ 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 Inverter capacity kVA 1.2 1.6 2.7 3.7 5.7 8.8 12 17 22 27 32 44 55 69 82 110 130 160 A 3.2 4.1 7.0 9.6 15 23 31 45 58 71 85 115 145 180 215 283 346 415 Fin W 20 27 50 70 112 164 219 374 429 501 586 865 1015 1266 1588 2019 2437 2733 Inside unit W 39 42 50 59 74 84 113 170 183 211 274 352 411 505 619 838 997 1242 Total heat loss W 59 69 100 129 186 248 332 544 612 712 860 1217 1426 1771 2207 2857 3434 3975 Heat loss W Rated current Fin cooling Self cooled Fan cooled 400 V class Model CIMR-E7Z@ 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 Inverter capacity kVA 1.4 1.6 2.8 4.0 5.8 6.0 9.5 13 18 24 30 34 46 57 69 85 A 1.8 2.1 3.7 5.3 7.6 8.0 12.5 17 24 31 39 45 60 75 91 112 150 180 216 260 304 370 506 675 Fin W 14 17 36 59 80 91 127 193 252 326 426 466 678 784 901 120 139 161 209 238 279 323 374 583 Inside unit W 39 41 48 56 68 70 82 Total heat loss W 53 58 84 115 148 161 209 307 410 498 634 725 995 114 131 169 197 228 295 339 393 460 527 815 Rated current Heat loss W 401 401 401 402 403 403 404 405 407 409 411 413 416 418 422 430 1 5 8 2 0 7 5 5 5 0 0 2 0 5 0 0 Fin cooling 110 140 160 200 230 280 390 510 114 158 172 208 259 317 360 415 495 575 671 853 100 114 137 153 232 Self cooled Fan cooled Installation conditions for IP54 Install the inverter vertically in order to ensure a proper cooling. When installing the inverter, always provide the following minimum installation space to allow normal heat dissipation. 50 mm min. 120 mm min. Air 30 mm min. 30 mm min. 120 mm min. 50 mm min. Horizontal space Horizontal Space Air Vertical Verticalspace Spcae 1. Always provide enough space for the main circuit or control lines including cable gland. 2. If installing inverters next to one another provide a minimum spacing of 60 mm. 16 Varispeed E7 Varispeed E7 13 Connections for braking units Braking resistor overload Relay trip contact (thermal relay trip contact) Braking resistor overload relay trip contact (thermal relay trip contact) Braking resistor unit Level detector Varispeed E7 Braking resistor unit *3 Braking unit 2*2 Braking unit 1 Cooling fin overheat contact (thermoswitch contact) Cooling fin overheat contact (thermoswitch contact) AC reactor Application example Connection example Power supply capacity (kVA) AC reactor MCCB Motor AC reactor required for power supply harmonics Varispeed E7 AC reactor not required Inverter capacity (kVA) Max. applicable motor output kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 Frequency inverters 14 200 V class Current value A 2.5 5 10 15 20 30 40 60 80 90 120 160 200 240 280 360 500 500 Inductance mH 4.2 2.1 1.1 0.71 0.53 0.35 0.265 0.18 0.13 0.12 0.09 0.07 0.05 0.044 0.038 0.026 0.02 0.02 Max. applicable motor output kW 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90/110 132/160 185 220 300 400 V class Current value A 1.3 2.5 5 7.5 10 15 20 30 40 50 60 80 90 120 150 200 250 330 490 660 Inductance mH 18.0 8.4 4.2 3.6 2.2 1.42 1.06 0.7 0.53 0.42 0.36 0.26 0.24 0.18 0.15 0.11 0.09 0.06 0.04 0.03 17 Frequency inverters DC reactor DC reactor MCCB Motor Varispeed E7 Power supply capacity (kVA) Take off the common bar between G1 and G2, and wire as shown in the diagram. With reactor for power supply coordination Without reactor Inverter capacity (kVA) 200 V class 400 V class Max. applicable motor output kW Current value A Inductance mH 0.4 5.4 8 0.75 Max. applicable motor output kW Current value A Inductance mH 0.4 3.2 28 5.7 11 0.75 1.5 18 3 2.2 1.5 2.2 3.7 5.5 36 1 72 0.5 7.5 3.7 12 6.3 5.5 23 3.6 33 1.9 7.5 11 15 11 15 18.5 90 22 to 110 0.4 Built-in 18.5 47 22 to 300 1.3 Built-in Fuse installation To protect the inverter, it is recommended to use semiconductor fuses as shown in the table below Inverter type 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 18 Varispeed E7 Inverter type FUSE Voltage (V) Current (A) I2t (A2s) 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 10 10 15 20 30 40 60 80 100 130 150 180 240 300 350 450 550 600 12~25 12~25 23~55 34~98 82~220 220~610 290~1300 450~5000 1200~7200 1800~7200 870~16200 1500~23000 2100~19000 2700~55000 4000~55000 7100~64000 11000~64000 13000~83000 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 FUSE Voltage (V) Current (A) I2t (A2s) 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 5 5 10 10 15 20 25 30 50 60 70 80 100 125 150 150 250 300 350 400 450 600 700 900 6~55 6~55 10~55 18~55 34~72 50~570 100~570 100~640 150~1300 400~1800 700~4100 240~5800 500~5800 750~5800 920~13000 1500~13000 3000~55000 3800~55000 5400~23000 7900~64000 14000~250000 20000~250000 34000~400000 52000~920000 Varispeed E7 15 Ordering information 3G3IV-PCN329-E Inverter to PC cable CX-Drive JVOP-160 OY Digital operator (LCD display) JVOP-161-OY Digital operator (LED display) 3G3IV-PCN126/326 Digital operator extension cable D D D D D Line Filter Braking accessories * see note A Varispeed E7 LKEB_ braking resistor unit CDBR_B braking unit E * E7 IP54 types are built-in filter inverters. PLC option card T1 JP3 Communication card JP1 U6 C3 R28 C28 R8 R120 U1 TR2 + R75 R114 C17 R14 U14 R21 R5 R25 R15 R15 R15 + 2 + R55 R54 R56 R57 R40 R39 R78 C35 R99 U12 U15 R10 5 C11 R10 R10 R6 D6 C39 C5 R20 R30 R95 R7 R131 TR1 C2 Y1 C22 11 R11 R110 R107 R70 U10 U8 C24 U11 C16 R113 R5 C21 R3 R36 R35 U10 U7 C1 R R1 R2 C33 + + U9 R11 C26 R6 R52 PE R102 C12 JP5 C13 JP6 R95 RT4 R94 R97 C20 R96 U13 U17 COD B E No. SI-N 736 C10 00C02 10 C Varispeed E7 200 V 400 V Specifications IP20 IP00 0.55 Kw Model 3.2 A CIMR-E7Z20P41 Specifications IP20 Model 0.55 Kw 1.8 A CIMR-E7Z40P41 0.75 Kw 4.1 A CIMR-E7Z20P71 0.75 Kw 2.1 A CIMR-E7Z40P71 1.5 Kw 7.0 A CIMR-E7Z21P51 1.5 Kw 3.7 A CIMR-E7Z41P51 2.2 Kw 9.6 A CIMR-E7Z22P21 2.2 Kw 5.3 A CIMR-E7Z42P21 3.7 Kw 15 A CIMR-E7Z23P71 3.7 Kw 7.6 A CIMR-E7Z43P71 5.5 Kw 23 A CIMR-E7Z25P51 4.0 Kw 8.7 A CIMR-E7Z44P01 7.5 Kw 31 A CIMR-E7Z27P51 5.5 Kw 12.5 A CIMR-E7Z45P51 11 Kw 45 A CIMR-E7Z20111 7.5 Kw 17 A CIMR-E7Z47P51 15 Kw 58 A CIMR-E7Z20151 11 Kw 24 A CIMR-E7Z40111 18.5 Kw 71 A CIMR-E7Z20181 15 Kw 31 A CIMR-E7Z40151 22 Kw 85 A CIMR-E7Z20220 18.5 Kw 39 A CIMR-E7Z40181 30 Kw 115 A CIMR-E7Z20300 22 Kw 45 A CIMR-E7Z40220 37 Kw 145 A CIMR-E7Z20370 30 Kw 60 A CIMR-E7Z40300 45 Kw 180 A CIMR-E7Z20450 37 Kw 75 A CIMR-E7Z40370 55 Kw 215 A CIMR-E7Z20550 45 Kw 91 A CIMR-E7Z40450 75 Kw 283 A CIMR-E7Z20750 55 Kw 112 A CIMR-E7Z40550 90 Kw 345 A CIMR-E7Z20900 75 Kw 150 A CIMR-E7Z40750 110 Kw 415 A CIMR-E7Z21100 90 Kw 180 A CIMR-E7Z40900 110 Kw 216 A CIMR-E7Z41100 132 Kw 260 A CIMR-E7Z41320 160 Kw 304 A CIMR-E7Z41600 185 Kw 370 A CIMR-E7Z41850 220 Kw 506 A CIMR-E7Z42200 300 Kw 675 A CIMR-E7Z43000 Frequency inverters 16 IP00 19 Frequency inverters Varispeed E7 IP54 400 V Specifications IP54 Model 7.5 Kw 17 A CIMR-E7Z47P52 11 Kw 24 A CIMR-E7Z40112 15 Kw 31 A CIMR-E7Z40152 18.5 Kw 39 A CIMR-E7Z40182 22 Kw 45 A CIMR-E7Z40222 30 Kw 60 A CIMR-E7Z40302 37 Kw 75 A CIMR-E7Z40372 45 Kw 91 A CIMR-E7Z40452 55 Kw 112 A CIMR-E7Z40552 A Input filters 200 V 400 V Inverter model Line filters Varispeed E7 Type CIMR-E7Z20P4 3G3RV-PFI3010-SE CIMR-E7Z20P7 1 Inverter model EN55011 class Current (A) Weight (kg) B, 25 m A, 100 m 10 1.1 3G3RV-PFI3018-SE B, 25 m A, 100 m 18 1.3 CIMR-E7Z23P7 3G3RV-PFI2035-SE B, 25 m A, 100 m 35 1.4 3G3RV-PFI2060-SE B, 25 m A, 100 m 60 3 B, 25 m A, 100 m 100 A, 100 m 130 CIMR-E7Z25P5 CIMR-E7Z2011 CIMR-E7Z2015 3G3RV-PFI2100-SE CIMR-E7Z2018 CIMR-E7Z2022 3G3RV-PFI2130-SE 4.9 4.3 CIMR-E7Z2030 CIMR-E7Z2037 3G3RV-PFI2160-SE A, 100 m 160 6.0 CIMR-E7Z2045 3G3RV-PFI2200-SE A, 100 m 200 11.0 3G3RV-PFI3400-SE A, 100 m 400 18.5 CIMR-E7Z2055 CIMR-E7Z2075 CIMR-E7Z2090 CIMR-E7Z2110 1. Weight (kg) B, 25 m A, 100 m 10 1.1 3G3RV-PFI3018-SE B, 25 m A, 100 m 18 1.3 3G3RV-PFI3035-SE B, 25 m A, 100 m 35 2.1 3G3RV-PFI3060-SE B, 25 m A, 100 m 60 4.0 3G3RV-PFI3070-SE A, 100 m 70 3.4 3G3RV-PFI3130-SE A, 100 m 130 4.7 CIMR-E7Z4075 3G3RV-PFI3170-SE A, 100 m 170 6.0 CIMR-E7Z4090 3G3RV-PFI3200-SE A, 100 m 250 11 3G3RV-PFI3400-SE A, 100 m 400 18.5 3G3RV-PFI3600-SE A, 100 m 600 11,0 3G3RV-PFI3800-SE A, 100 m 800 31.0 Model CIMR-E7Z40P4 3G3RV-PFI3010-SE CIMR-E7Z41P5 CIMR-E7Z22P2 CIMR-E7Z27P5 Current (A) Varispeed E7 CIMR-E7Z40P7 CIMR-E7Z21P5 Line filter 1 EN 55011 class* 3G3RV-PFI3600-SE A, 100 m Varispeed E7 is a built-in filter inverter. 600 11.0 CIMR-E7Z42P2 CIMR-E7Z43P7 CIMR-E7Z44P0 CIMR-E7Z45P5 CIMR-E7Z47P5 CIMR-E7Z4011 CIMR-E7Z4015 CIMR-E7Z4018 CIMR-E7Z4022 CIMR-E7Z4030 CIMR-E7Z4037 CIMR-E7Z4045 CIMR-E7Z4055 CIMR-E7Z4110 CIMR-E7Z4132 CIMR-E7Z4160 CIMR-E7Z4185 CIMR-E7Z4220 CIMR-E7Z4300 1. 20 Varispeed E7 Varispeed E7 is a built-in filter inverter. Varispeed E7 17 B Communication cards Communication option cards Type Model Description 3G3RV-PDRT2 DeviceNet option card SI-P1 PROFIBUS-DP option card SI-S1 CANopen option card CM090 Ethernet option card SI-J1 LONWORKS option card Function * Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller. * Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through PROFIBUS-DP communication with the host controller. * Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller. * MODBUS TCP/IP Ethernet interface unit. * Used for HVAC control, running or stopping the inverter, setting or referencing parameters, and monitoring output current, watt-hours, or similar items through LONWORKS communications with peripheral devices. C PLC Option Card Model 3G3RV-P10CDT-E Description Function * Full features, wireless installation and seamless access to the inverter parameters and analogue/digital inputs and outputs * Embedded Compobus/S fieldbus * Standard OMRON tools can be used for programming * Same features as standard models with DeviceNet support PLC option PLC option cards Type PLC option with DeviceNet 3G3-P10CDT-E-DRT D Accessories Type Model JVOP-160-OY Description Installation 5 lines LCD digital operator 1 Panel cutout 57 Panel 2-M3 MTG Holes 70 44 Through Hole 20 14.5 2.5 7 segment LED digital operator 120 111 120 Digital operators JVOP-161-OY 70 15.8 JVOP-162 6.4 (60) Hand-Off auto operator Accessories Panel cutout installation 1. 3G3IV-PCN126 3G3IV-PCN326 Digital operator extension cable 1 meter 3 meters ----- 3G3IV-PCN329-E PC configuration cable ----- LCD digital operator is the Standard in IP54 types. D Computer software Software Type Model Description Function CX-drive Computer software Configuration and monitoring software tool CX-One Computer software Configuration and monitoring software tool Frequency inverters 18 21 Frequency inverters E Braking unit, braking resistor unit Braking resistor unit Separately-installed type (10 %ED, 10 sec. max.)1 Braking unit Inverter Voltage Max. applicable motor output kW Model CIMR-E7Z@ 200 V class 400 V class 1. 2. 3. Model CDBR@ No. of used Model LKEB@ Specifications of resistor No. of used Braking torque % Connectable min resistance value 0.4 20P4 20P7 70 W 200 1 220 48 0.75 20P7 20P7 70 W 200 1 125 48 1.5 21P5 21P5 260 W 100 1 125 48 2.2 22P2 22P2 260 W 70 1 120 16 3.7 23P7 23P7 390 W 40 1 125 16 5.5 25P5 25P5 520 W 30 1 115 16 7.5 27P5 27P5 780 W 20 1 125 9.6 11 2011 2011 2400 W 13.6 1 125 9.6 15 2015 2015 3000 W 10 1 125 9.6 18.5 2018 2015 3000 W 10 1 125 9.6 22 2022 2022 4800 W 6.8 1 125 6.4 30 2015B 1 2022B 1 2030 2015B 2 2015 3000 W 10 2 125 9.6 37 2037 2015B 2 2015 3000 W 10 2 100 9.6 45 2045 2022B 2 2022 4800 W 6.8 2 120 6.4 55 2055 2022B 2 2022 4800 W 6.8 2 100 6.4 75 2075 2110B 1 2022 4800 W 6.8 3 110 1.6 90 2090 2110B 1 2022 4800 W 6.8 4 120 1.6 110 2110 2110B 1 2018 4800 W 8 5 100 1.6 0.4 40P4 40P7 70 W 750 1 230 96 0.75 40P7 40P7 70 W 750 1 130 96 1.5 41P5 41P5 260 W 400 1 125 64 2.2 42P2 42P2 260 W 250 1 135 64 3.7 43P7 43P7 390 W 150 1 135 32 5.5 45P5 45P5 520 W 100 1 135 32 7.5 47P5 47P5 780 W 75 1 130 32 11 4011 4011 1040 W 50 1 135 20 15 4015 4015 1560 W 40 1 125 20 18.5 4018 4018 4800 W 32 1 125 19.2 22 4022 4022 4800 W 27.2 1 125 19.2 30 4030 4030 6000 W 20 1 125 19.2 37 4037 4045B 1 4037 9600 W 16 1 125 12.8 45 4045 4045B 1 4045 9600 W 13.6 1 125 12.8 55 4055 4030B 2 4030 6000 W 20 2 135 19.2 75 4075 4045B 2 4045 9600 W 13.6 2 145 12.8 90 4090 4220B 1 4030 6000 W 20 3 100 3.2 110 4110 4220B 1 4030 6000 W 20 3 100 3.2 132 4132 4220B 1 4045 9600 W 13.6 4 140 3.2 160 4160 4220B 1 4045 9600 W 13.6 4 140 3.2 185 4185 4220B 1 4045 9600 W 13.6 4 120 3.2 220 4220 4220B 1 4037 9600 W 16 5 110 3.2 300 4300 4220B 2 4045 9600 W 13.6 6 110 3.2 4030B 1 Load factor during deceleration to stop a load with constant torque. With constant output or continuous regenerative braking, the load factor is smaller than the specified value. Resistance value per one braking unit. Select a resistance value that is larger than connectable minimum resistance value to obtain enough braking torque. For an application with large regenerative power such as hoisting, the braking torque or other items may exceed the capacity of a braking unit with a braking resistor in a standard combination (can result in capacity overload). Contact your OMRON representatives when the braking torque or any other item exceeds the values in the table. 22 Varispeed E7 Varispeed E7 19 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. I21E-EN-02 Frequency inverters 20 In the interest of product improvement, specifications are subject to change without notice. 23 Frequency inverters Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.omron-industrial.com Austria Tel: +43 (0) 1 80 19 00 www.omron.at France Tel: +33 (0) 1 56 63 70 00 www.omron.fr Netherlands Tel: +31 (0) 23 568 11 00 www.omron.nl Spain Tel: +34 913 777 900 www.omron.es Belgium Tel: +32 (0) 2 466 24 80 www.omron.be Germany Tel: +49 (0) 2173 680 00 www.omron.de Norway Tel: +47 (0) 22 65 75 00 www.omron.no Sweden Tel: +46 (0) 8 632 35 00 www.omron.se Czech Republic Tel: +420 234 602 602 www.omron.cz Hungary Tel: +36 (0) 1 399 30 50 www.omron.hu Poland Tel: +48 (0) 22 645 78 60 www.omron.pl Switzerland Tel: +41 (0) 41 748 13 13 www.omron.ch Denmark Tel: +45 43 44 00 11 www.omron.dk Italy Tel: +39 02 326 81 www.omron.it Portugal Tel: +351 21 942 94 00 www.omron.pt Turkey Tel: +90 (0) 216 474 00 40 www.omron.com.tr Finland Tel: +358 (0) 207 464 200 www.omron.fi Middle East & Africa Tel: +31 (0) 23 568 11 00 www.omron-industrial.com Russia Tel: +7 495 745 26 64 www.omron.ru United Kingdom Tel: +44 (0) 870 752 08 61 www.omron.co.uk More Omron representatives www.omron-industrial.com Authorised Distributor: Control Systems * Programmable logic controllers * Human-machine interfaces * Remote I/O Motion & Drives * Motion controllers * Servo systems * Inverters Control Components * Temperature controllers * Power supplies * Timers * Counters * Programmable relays * Digital panel indicators * Electromechanical relays * Monitoring products * Solid-state relays * Limit switches * Pushbutton switches * Low voltage switch gear Sensing & Safety * Photoelectric sensors * Inductive sensors * Capacitive & pressure sensors * Cable connectors * Displacement & width-measuring sensors * Vision systems * Safety networks * Safety sensors * Safety units/relay units * Safety door/guard lock switches E7_IP54_01_EN_INT Although we strive for perfection, Omron Europe BV and/or its subsidiary and affiliated companies do not warrant or make any representations regarding the correctness or completeness of the information described in this document. We reserve the right to make any changes at any time without prior notice. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: CIMR-E7Z41600B CIMR-F7Z40P7 CIMR-F7Z42P21 CIMR-F7Z47P51