www.clare.com
LCA220
Rev. 6
Electrical Characteristics
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at these or
any other conditions beyond those indicated in the opera-
tional sections of this data sheet is not implied. Exposure
of the device to the absolute maximum ratings for an
extended period may degrade the device and effect its
reliability.
Absolute Maximum Ratings (@ 25˚ C)
2
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics @ 25°C
Load Voltage (Peak) - VL- - 250 V
Load Current (Continuous) - IL- - 120 mA
Peak Load Current 10ms max ILPK - - 340 mA
On-Resistance IL=120 mA RON --20Ω
Off-State Leakage Current VL=250V ILEAK --1mA
Switching Speeds
Turn-On IF=10mA, VL=10V TON --5mS
Turn-Off IF=10mA, VL=10V TOFF --5mS
Output Capacitance 50V; f=1MHz COUT -50- pF
*Input Characteristics @ 25°C
Input Control Current IL=120mA IF10 - 100 mA
Input Dropout Current - - 0.8 1.4 - mA
Input Voltage Drop IF=10mA VF0.9 1.2 1.4 V
Reverse Input Voltage - VR--5V
Reverse Input Current VR=5V IR--20mA
Input to Output Capacitance - CI/O -3-pF
Input to Output Isolation - VI/O 3750 - - VRMS
*Input characteristics represent requirements of two parallel connected LEDs.
Parameter Min Typ Max Units
Input Power Dissipation - - 1501mW
Input Control Current - - 100 mA
Peak (10ms) - - 1 A
Reverse Input Voltage - - 5 V
Total Power Dissipation - - 8002mW
Isolation Voltage
Input to Output 3750 - - VRMS
Operational Temperature -40 - +85 °C
Storage Temperature -40 - +125 °C
Soldering Temperature
DIP Package - - +260 °C
Flatpack/Surface Mount
Package - - +220 °C
(10 Seconds Max.)
1Derate Linearly 1.33 mw/˚C
2Derate Linearly 6.67 mw/˚C