RECTIFIERS 1N5615, 1N5617, 1N5619 o JAN, JANTX & JANTXV Milttary Approved, Fast Recovery, 1 Amp FEATURES DESCRIPTION Qualified to MIL-S-19500/429 This series of military approved rectifiers is @ PIV: to 600V useful in many military applications where Controlled Avatanche fast recovery and medium power are required. The 100% screening requirements in the TX version combined with the unique Unitrode construction assures the highest degree of reliability. ABSOLUTE MAXIMUM RATINGS Peak Inverse Voltage Type 200V JAN, JANTX, JANTXV 1N5615 400V JAN, JANTX, JANTXV 1N5617 600V JAN, JANTX, JANTXV 1N5619 Maximum Average D.C. Output Current @ Tg SC ee ce ccc tcecce eccnesesnteegesemneteessiarseenmttsseens 10A Ty 00 cece cece eecee teeta tiscsensreeeeseeiie . 0.75A Non-Repetitive Sinusoidal Surge Current (8.3MS$) 000000 . 2A Operating Temperature Range .. coe cteeteteseeteretsetertesegritingraititeustentersneters | ~65C to }175C Storage Temperature Range 00 ttcttttee =65C to +200C Thermal Resistance 9), ....... cosesiettes sonresenteuesitesssruiviiessesrannanssereseesnssmmierscseensnet 38C/W See Lead Temperature Derating Curve MECHANICAL SPECIFICATIONS J, JTX, JTXV 1NS5615, 1N5617, 1NS619 BODY A Je 195 TYP 928" ~ C01 | Band indicates 19mm 071mm cathode end\ | a .055" TYP. 085" MAX a.) ir 3 Fe Pro t 1 We. eet | anm 700" MiN._| 250, MAX. 17.8mm Lg MN tt) 241 am UNITRODEELECTRICAL SPECIFICATIONS (at 25C unless noted) JAN, JANTX, JANTXV 1N5615, 1N5617, 1N5619 Minimum Reverse Maximum Maximum Breakdown Forward Reverse Reverse Capacitance Voltage Voltage Current Recovery @V, = 12V Type PIV @ 50nA Min. Tq Max. 25C 100C Time* f = MHZ J, JTX, STXV 1N5615 200V 220V o.aV Levipk) | O.5uA | 25uA 150ns 45pf J, JTX, JTXV 1N5617 400V 440V @ 3.0 Ade 150ns 35pf J, JTX, JTXV 1N5619 600V 660V tp = 300us 250ns 25pf Measured in Circuit |; = 2A, Ip = 1A, Ingo = YA Maximum Current vs Lead Temperature 4 ly AVERAGE RECTIFIED CURRENT (A) 25 50 100 128 0 180175 T, ~ LEAD TEMPERATURE (C) Maximum Power vs. Lead Temperature o MAXIMUM POWER DISSIPATION (W) SorNwW eU AY @ wo N o 50 a tote d L == Lead Length 100 from Body L ='.750" 125 150 175 T, LEAD TEMPERATURE (C) , wamod DeGLT = 1 Reverse-Recovery Circuit loe Typical Reverse Current vs. PIV 0001 0002 -0005 . CURRENT (A) I, (uA) | o 150 100 50 0 So PIV Forward Voltage vs. Forward Current So S us os 1, CURRENT (mA) aa) Nn o o me o fe 3 | mn ow 2 GS OB 1 12 14 16 V, VOLTAGE (Vv) + PULSE = BN GENERATOR =" (APPROX.) Nees - 12 NOTE 3 OSCILLOSCOPE + NOTE1 A NOTES: 1. Oscilloscope: Rise time < 3ns; input impedance = 502. 2. Pulse Generator: Rise time < 8ns; source impedance 10. 3. Current viewing resistor, non-inductive, coaxial recommended. UNITRODE CORPORATION + 5 FORBES ROAD LEXINGTON, MA 02173 TEL. (617) 861-6540 TWX (710) 326-6509 + TELEX 95-1064 242 PRINTED IN U.S.A.