SYLVANIA is a registered trademark of OSRAM SYLVANIA Inc.
SEE THE WORLD IN A NEW LIGHT is a registered trademark of OSRAM SYLVANIA Inc.
OSRAM and OPTOTRONIC are registered trademarks of OSRAM GmbH.
Specifications subject to change without notice.
OSRAM LED products are covered by our LED
Module, OPTOTRONIC® Power Supply or Control
warranty.
The Distributed Array Gen II LED Module Portfolio
is covered under warranty as long as the
temperature at the Tc point does not exceed 85°C;
exceeding this temperature will void all
warranties.
For additional information or to download the
warranty registration form, refer to the latest
version of the warranty (LED089) available in the
Literature section of www.sylvania.com/LED.
Module Warranty: 3 years
System Warranty: 5 years
Warranty
©2013OSRAMSYLVANIA4-13
Safety Information
1. The LED module itself and all its components shall not be subjected to mechanical stress and assembly must
not damage or destroy conducting paths on the circuit board.
2. Observe correct electrical polarity, incorrect polarity may destroy the module. (Depending on the product,
incorrect polarity may lead to emission of red or no light.)
3. Ensure the power supply is of adequate power to operate the total load.
4. Electrostatic Discharge (ESD) precautions shall be incorporated when handling or installing the module.
(For more information, reference document # LED093 ESD Protection for LED Systems.)
5. Installation of LED modules shall be made with regard to all applicable electrical and safety standards.
Only qualified personnel should be allowed to perform installations.
6. Modules may be hot to the touch. Use caution when handling.
7. Damage by corrosion and improper heat sinking will not be honored as a materials defect claim. It is the
user’s responsibility to ensure adequate heat sink and protection against corrosive agents such as moisture,
condensation and other harmful elements.
WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION.
TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE
ATTEMPTING INSTALLATION OF THE POWER SUPPLIES AND/OR LIGHT ENGINES.
Failure to install the power supplies and/or LED light engines in accordance with the National Electric Code (NEC), all
applicable Federal, State and local electric codes as well as the specic Underwriters Laboratories (UL) safety stan-
dards for the installation, location and application may cause serious personal injury, death, property damage and/or
product malfunction.
Assembly Information
1. The Distributed Array Gen II boards needs no supplemental heat sinking when the temperature at the Tc Point is
maintained at or below 85°C. Service life when the Tc temperature is maintained is >60,000 hours/L70. When
the environment is unknown, the Distributed Array products should be installed in luminaires designed to provide
proper thermal management to avoid premature failure of the product and to obtain expected service life. Service
life (i.e. lumen depreciation) is primarily a function of LED temperature, which is to be monitored on the circuit
board at the designated “Tc Point.”
2. Due to variations in fixture designs, there is no exact installation prescription for obtaining an appropriate Tc Point
temperature. In general, the Distributed Array Gen II modules should be adhered to a flat metal surface which has
enough surface area to transfer the heat from the LEDs to the surrounding air. In some cases, the metal surface
can be part of the mass of the fixture itself.
3. It is important to understand that once heat is transferred to a “heat sink” that heat must still be allowed
to escape the “system.” A heat sink transferring the thermal energy to the inside of an enclosed cavity may
ultimately be of little use.
4. Tc Point temperature measurements should be taken with the modules operating at thermal equilibrium in
potential fixture designs installed in an appropriate environment. Tc Point temperature can be measured with a
standard thermocouple in direct contact with the circuit board at the Tc Point or with ML4C Series non-reversible
OMEGALABELS (www.omega.com) or equivalent.
5. Recommended input and board to board connections: Use 18 AWG solid core or stranded wire with a strip length
of 0.24 - 0.28 in (6 - 7mm). Use direct push-in of solid conductors and push button for connection of stranded
conductors and for removal of all wire types.
United States
OSRAM SYLVANIA
100 Endicott Street
Danvers, MA 01923
1-800-LIGHTBULB
Trade
Phone: 800-255-5042
Fax: 800-255-5043
National Accounts
Phone: 800-562-4671
Fax: 800-562-4674
OEM/Special Markets
Phone: 800-762-7191
Fax: 800-762-7192
Retail
Phone: 800-842-7010
Fax: 800-842-7011
SYLVANIA Lighting Services
Phone: 800-323-0572
Fax: 800-537-0784
Display/Optic
Phone: 888-677-2627
Fax: 855-543-1043
Canada
OSRAM SYLVANIA LTD.
2001 Drew Road
Mississauga, ON L5S 1S4
1-800-LIGHTBULB
Trade
Phone: 800-263-2852
Fax: 800-667-6772
OEM/Special Markets/Display/Optic
Phone: 800-265-2852
Fax: 800-667-6772
Retail
Phone: 800-720-2852
Fax: 800-667-6772
SYLVANIA Lighting Services
Phone: 800-663-4268
Fax: 866-239-1278
Mexico
OSRAM MEXICO
Tultitlan/Edo de Mexico
Phone: 011-52-55-58-99-18-50
ENCELIUM® Products
United States
Phone: 201-928-2400
Fax: 201-928-4028
Canada
Phone: 905-731-7678
Fax: 905-731-1401
www.sylvania.com
/sylvania
/sylvania