www.sylvania.com/LED Distributed Array Gen II LED Modules High efficacy solutions for diffuse ambient lighting Key Features & Benefits * High efficacy up to 145* LPW * Minimizes optical requirements * Uniform LED grid pattern * Color variation within 3 MacAdam steps * Parallel design for serial wiring * Poke in wire connectors * Can operate on single or multi channel power supply * Delivers even and diffuse light * Thermally independent requiring no additional heat sinking * Simplifies luminaire design The Distributed Array Gen II LED Module portfolio from OSRAM offers an innovative solution for ambient illumination applications. The Distributed Array Gen II boards consist of multiple low-power LEDs in a precise layout that enables thermal self-management, delivers high efficacy at all CCTs and eliminates the need for supplemental heat sinking. The boards produce an even and diffuse light that reduces the need for multiple optical layers, simplifying the luminaire design and maximizing optical efficiency. The Distributed Array Gen II products are a long-life, energy-efficient alternative to linear fluorescent sources. * Ideal replacement for linear or area fluorescent sources * 80+ CRI * Service life >60,000 hours when temperature at Tc point is maintained at 85C * Compatible with dimming systems Product Offering Ordering Abbreviation L9LR/250C/8xx/DA1R/280x19 L9LR/250C/8xx/DA1R/280x38 L6LR/166C/8xx/DA3R/178x38 L8LR/250C/8xx/DA3R/229x38 L9LR/250C/8xx/DA3R/280x38 L9LR/250C/8xx/DA3R/289x38 L9AR/250C/8xx/DA/221x221 L16AR/435C/8xx/DA/259x259 Nominal Length (LxW) 11" x 0.75" 11" x 1.5" 7" x 1.5" 9" x 1.5" 11" x 1.5" 11.4" x 1.5" 8" x 8" 10" x 10" The Distributed Array Gen II LED Modules are designed for optimum performance when paired with OPTOTRONIC(R) constant current power supplies for maximum system efficiency and life expectancy. *Higher LPW is possible at lower drive currents Application Information Applications * * * * * Accent/decorative lighting General lighting Office lighting Task lighting Undercabinet lighting LED314R1 4-13 Specifications and Certifications T he OSRAM Distributed Array Gen II Family is UL8750 Recognized for US and Canada Class 2 Units (UL File# E320662). LED Rows 1 1 3 3 3 3 Square Panel Square Panel Specification Data Catalog # Type Project Comments Prepared by Ordering Information Item Ordering Number Abbreviation 72121 L9LR/250C/830/DA1R/280x19 72135 L9LR/250C/835/DA1R/280x19 72161 L9LR/250C/840/DA1R/280x19 72165 L9LR/250C/850/DA1R/280x19 72104 L9LR/250C/830/DA1R/280x38 72105 L9LR/250C/835/DA1R/280x38 72106 L9LR/250C/840/DA1R/280x38 72120 L9LR/250C/850/DA1R/280x38 71991 L6LR/166C/827/DA3R/178x38 71992 L6LR/166C/830/DA3R/178x38 71993 L6LR/166C/835/DA3R/178x38 71994 L6LR/166C/840/DA3R/178x38 71995 L6LR/166C/850/DA3R/178x38 71996 L8LR/250C/830/DA3R/229x38 71997 L8LR/250C/835/DA3R/229x38 71998 L8LR/250C/840/DA3R/229x38 71999 L8LR/250C/850/DA3R/229x38 71987 L9LR/250C/830/DA3R/280x38 71988 L9LR/250C/835/DA3R/280x38 71989 L9LR/250C/840/DA3R/280x38 71990 L9LR/250C/850/DA3R/280x38 71912 L9LR/250C/830/DA3R/289x38 71913 L9LR/250C/835/DA3R/289x38 71914 L9LR/250C/840/DA3R/289x38 71915 L9LR/250C/850/DA3R/289x38 72211 L9AR/250C/830/DA/221x221 72242 L9AR/250C/835/DA/221x221 72246 L9AR/250C/840/DA/221x221 72255 L9AR/250C/850/DA/221x221 72204 L16AR/435C/830/DA/259x259 72206 L16AR/435C/835/DA/259x259 72207 L16AR/435C/840/DA/259x259 72210 L16AR/435C/850/DA/259x259 Max Rated Input Drive Dimensions Qty. of Input Color Current (mA) (L x W) LEDs Power (W)* Temperature CRI 300 11'' x 0.75'' 36 10.5 3000K >80 300 11'' x 0.75'' 36 10.5 3500K >80 300 11'' x 0.75'' 36 10.5 4000K >80 300 11'' x 0.75'' 36 10.5 5000K >80 300 11" x 1.5" 36 10.5 3000K >80 300 11" x 1.5" 36 10.5 3500K >80 300 11" x 1.5" 36 10.5 4000K >80 300 11" x 1.5" 36 10.5 5000K >80 200 7" x 1.5" 24 7 2700K >80 200 7" x 1.5" 24 7 3000K >80 200 7" x 1.5" 24 7 3500K >80 200 7" x 1.5" 24 7 4000K >80 200 7" x 1.5" 24 7 5000K >80 300 9" x 1.5" 30 9 3000K >80 300 9" x 1.5" 30 9 3500K >80 300 9" x 1.5" 30 9 4000K >80 300 9" x 1.5" 30 9 5000K >80 300 11" x 1.5" 36 10.5 3000K >80 300 11" x 1.5" 36 10.5 3500K >80 300 11" x 1.5" 36 10.5 4000K >80 300 11" x 1.5" 36 10.5 5000K >80 300 11.4" x 1.5" 36 10.5 3000K >80 300 11.4" x 1.5" 36 10.5 3500K >80 300 11.4" x 1.5" 36 10.5 4000K >80 300 11.4" x 1.5" 36 10.5 5000K >80 300 8.7'' x 8.7'' 36 10.5 3000K >80 300 8.7'' x 8.7'' 36 10.5 3500K >80 300 8.7'' x 8.7'' 36 10.5 4000K >80 300 8.7'' x 8.7'' 36 10.5 5000K >80 500 10.2'' x 10.2'' 60 18 3000K >80 500 10.2'' x 10.2'' 60 18 3500K >80 500 10.2'' x 10.2'' 60 18 4000K >80 500 10.2'' x 10.2'' 60 18 5000K >80 Lumens (lm)* 1175 1200 1250 1200 1175 1200 1250 1200 800 800 800 800 800 1000 1000 1000 1000 1150 1175 1225 1250 1150 1175 1225 1250 1200 1225 1225 1250 2050 2050 2175 2100 LPW 112 114 119 114 112 114 119 114 114 114 114 114 114 111 111 111 111 110 112 117 119 110 112 117 119 114 117 117 119 114 114 121 117 * Nominal ratings at board Tc of 35C (5). Notes: 1. All data is related to the entire module. Data reflects statistical mean values. Actual data may differ depending on variances in the manufacturing process. 2. Performance values were taken at steady state. Instant-on measurements may be higher. 3. Recommended for indoor use. 4. Meets Zhaga Consortium Book 7. Ordering Guide L 9 L R / XXXC / 8 LED Wattage L = Linear RigidXXX = Current in mA CRI > 80 A = Area 30 / DAXX / YYYxZZZ CCT DA = Distributed Array Square Panel YYY = Length in mm. 27 = 2700K DA1R = Distributed Array 1 Row of LEDs ZZZ = Width in mm. 30 = 3000K DA3R = Distributed Array 3 Rows of LEDs 35 = 3500K 40 = 4000K 50 = 5000K Power Supply Information OT40W Single-Channel Programmable OT50W Multi-Channel (4 Channels) OT80W or OT100W Multi-Channel (4 Channels) 4, NAED 79441, 79442, 79448, 79449 (configured to 1140 mA) 4, NAED 79441, 79442, 79448, 79449 (configured to 1200 mA) 4, NAED 79441, 79442, 79448, 79449 (configured to 800 mA) 2, NAED 79441, 79442, 79448, 79449 (configured to 1000 mA) 4 (1 per Channel), NAED 79301 4 (1 per Channel), NAED 79301 4 (1 per Channel), NAED 79305 2 (2 per Channel), NAED 79304 8 (2 per Channel), NAED 79552 8 (2 per Channel), NAED 79552 12 (3 per Channel), NAED 79552 4 (1 per Channel), NAED 79554 Module All 11'' 3R and 1R Modules All 8'' x 8'' Modules All 9'' 3R Modules All 7'' 3R Modules All 10'' x 10'' Modules Minimum and Maximum Ratings Parameter Operating Temperature at Tc Point Storage Temperature Range Values -30 to +85C (-22 to +185F) -30 to +80C (-22 to +176F) Notes: 1. Exceeding maximum ratings may damage the LED module and cause potential safety hazards. 2. Elevated operating temperatures can be expected to negatively impact the service life in terms of lumen output. 3. Incorrect wiring may damage the LED module. 4. Optimized for use with OPTOTRONIC constant current power supplies. Assembly Diagram 36 LED 11" x 0.75" 36 LED 11" x 1.5" Dimensions in inches (mm) Assembly Diagram 24 LED 7" x 1.5" 30 LED 9" x 1.5" 36 LED 11" x 1.5" - Meets Zhaga Consortium Book 7 36 LED 11.4" x 1.5" Dimensions in inches (mm) Assembly Diagram 36 LED 8" x 8" 60 LED 10" x 10" Dimensions in inches (mm) Wiring Diagram OPTOTRONIC(R) OTXX 4-Channel Power Supply Black (L) White (N) VOLTAGE 120-277 V AC 50/60Hz CONTROL 0-10 V DC INPUT DC (+) OUTPUT CH1 B(-) CH2 B(-) CH3 B(-) CH4 B(-) OPTOTRONIC OTXX 1-Channel Power Supply LED GRN BLK WHT LED + Input VAC PRG/NTC 700mA set DIM + DIM - BLUE RED BROWN ORANGE PURPLE GRAY Connect 700mA set (ORANGE) to LED - (BLUE) to set output current to 700 mA Purple (+) Gray (-) Red Blue Blue Blue Blue WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION. TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OF THE POWER SUPPLIES AND/OR LIGHT ENGINES. Failure to install the power supplies and/or LED light engines in accordance with the National Electric Code (NEC), all applicable Federal, State and local electric codes as well as the specific Underwriters Laboratories (UL) safety standards for the installation, location and application may cause serious personal injury, death, property damage and/or product malfunction. 1. The LED module itself and all its components shall not be subjected to mechanical stress and assembly must not damage or destroy conducting paths on the circuit board. 2. Observe correct electrical polarity, incorrect polarity may destroy the module. (Depending on the product, incorrect polarity may lead to emission of red or no light.) 3. Ensure the power supply is of adequate power to operate the total load. 4. Electrostatic Discharge (ESD) precautions shall be incorporated when handling or installing the module. (For more information, reference document # LED093 ESD Protection for LED Systems.) 5. Installation of LED modules shall be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. 6. Modules may be hot to the touch. Use caution when handling. 7. Damage by corrosion and improper heat sinking will not be honored as a materials defect claim. It is the user's responsibility to ensure adequate heat sink and protection against corrosive agents such as moisture, condensation and other harmful elements. Assembly Information 1. The Distributed Array Gen II boards needs no supplemental heat sinking when the temperature at the Tc Point is maintained at or below 85C. Service life when the Tc temperature is maintained is >60,000 hours/L70. When the environment is unknown, the Distributed Array products should be installed in luminaires designed to provide proper thermal management to avoid premature failure of the product and to obtain expected service life. Service life (i.e. lumen depreciation) is primarily a function of LED temperature, which is to be monitored on the circuit board at the designated "Tc Point." 2. D ue to variations in fixture designs, there is no exact installation prescription for obtaining an appropriate Tc Point temperature. In general, the Distributed Array Gen II modules should be adhered to a flat metal surface which has enough surface area to transfer the heat from the LEDs to the surrounding air. In some cases, the metal surface can be part of the mass of the fixture itself. 3. It is important to understand that once heat is transferred to a "heat sink" that heat must still be allowed to escape the "system." A heat sink transferring the thermal energy to the inside of an enclosed cavity may ultimately be of little use. 4. Tc Point temperature measurements should be taken with the modules operating at thermal equilibrium in potential fixture designs installed in an appropriate environment. Tc Point temperature can be measured with a standard thermocouple in direct contact with the circuit board at the Tc Point or with ML4C Series non-reversible OMEGALABELS (www.omega.com) or equivalent. 5. R ecommended input and board to board connections: Use 18 AWG solid core or stranded wire with a strip length of 0.24 - 0.28 in (6 - 7mm). Use direct push-in of solid conductors and push button for connection of stranded conductors and for removal of all wire types. Warranty OSRAM LED products are covered by our LED Module, OPTOTRONIC(R) Power Supply or Control warranty. The Distributed Array Gen II LED Module Portfolio is covered under warranty as long as the temperature at the Tc point does not exceed 85C; exceeding this temperature will void all warranties. For additional information or to download the warranty registration form, refer to the latest version of the warranty (LED089) available in the Literature section of www.sylvania.com/LED. Module Warranty: 3 years System Warranty: 5 years United States OSRAM SYLVANIA 100 Endicott Street Danvers, MA 01923 1-800-LIGHTBULB Trade Phone: 800-255-5042 Fax: 800-255-5043 National Accounts Phone: 800-562-4671 Fax: 800-562-4674 OEM/Special Markets Phone: 800-762-7191 Fax: 800-762-7192 Retail Phone: 800-842-7010 Fax: 800-842-7011 SYLVANIA Lighting Services Phone: 800-323-0572 Fax: 800-537-0784 Display/Optic Phone: 888-677-2627 Fax: 855-543-1043 Canada OSRAM SYLVANIA LTD. 2001 Drew Road Mississauga, ON L5S 1S4 1-800-LIGHTBULB Trade Phone: 800-263-2852 Fax: 800-667-6772 OEM/Special Markets/Display/Optic Phone: 800-265-2852 Fax: 800-667-6772 Retail Phone: 800-720-2852 Fax: 800-667-6772 SYLVANIA Lighting Services Phone: 800-663-4268 Fax: 866-239-1278 Mexico OSRAM MEXICO Tultitlan/Edo de Mexico Phone: 011-52-55-58-99-18-50 ENCELIUM(R) Products United States Phone: 201-928-2400 Fax: 201-928-4028 Canada Phone: 905-731-7678 Fax: 905-731-1401 www.sylvania.com SYLVANIA is a registered trademark of OSRAM SYLVANIA Inc. SEE THE WORLD IN A NEW LIGHT is a registered trademark of OSRAM SYLVANIA Inc. OSRAM and OPTOTRONIC are registered trademarks of OSRAM GmbH. Specifications subject to change without notice. /sylvania /sylvania (c) 2013 OSRAM SYLVANIA 4-13 Safety Information