MCX Series
• SIP SSR
• Ratings to 5A @ 660 VAC
• SCR output for heavy industrial loads
• AC or DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads)
output
• Plastic encapsulated
PRODUCT SELECTION
Control Voltage 5A 5A 5A
3-15 VDC MCX240D5
4-15 VDC MCX380D5 MCX480D5
15-32 VDC MCXE240D5 MCXE380D5 MCXE480D5
18-36 VAC MCXE240A5
90-140 VAC MCX240A5
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description 240VAC 380VAC 480VAC
Operating Voltage (47-63Hz) [Vrms] 12-280 48-530 48-660
Transient Overvoltage [Vpk] 600 1200 1200
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.1 0.1
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 500 500 500
Maximum Load Current [Arms](3) 5 5 5
Minimum Load Current [Arms] 0.06 0.06 0.06
Maximum Surge Current (16.6ms) [Apk] 250 250 250
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.4 1.4 1.4
Maximum I²t for fusing (8.3 msec) [A²sec] 260 260 260
Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5
INPUT SPECIFICATIONS (1)
Description MCX240Dx MCX380Dx MCXExxxDx MCX240A5 MCXE240A5
Control Voltage Range 3-15 VDC 4-15 VDC 15-32 VDC 90-140 VAC 18-36 VAC
Maximum Turn On Voltage 3.0 VDC 4.0 VDC 15.0 VDC 90.0 Vrms 18.0 Vrms
Mimimum Turn-Off Voltage 1.0 VDC 1.0 VDC 1.0 VDC 10.0 Vrms 2.0 VDC
Input Current @ Nominal Voltage 15 mAdc 15 mAdc 15 mAd c 10 mAdc 10 mAdc
Nominal Input Impedance 300 Ohm 240 Ohm 1500 Ohm 14.1 Ohm 2.1 k Ohm
Maximum Turn-On Time [msec] (3) 1/2 Cycle 1/2 Cycle 1/2 Cycle 10 10
Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle 40 40
GENERAL SPECIFICATIONS
Description Parameters
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms
Minimum Insulation Resistance (@ 500 VDC) 10 9 Ohm
Maximum Capacitance, Input/Output 10pF
Ambient Operating Temperature Range -40 to 80 °C
Ambient Storage Temperature Range -40 to 125 °C
Weight (typical) 0.7 oz. (20g)
Encapsulation Therminally Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) Turn-On time for random turn-on versi ons is 0.01 msec (DC Control Models).
WIRING DIAGRAM
MECHANICAL SPECIFICATIONS
THERMAL DERATING INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
E116949
Rev. 111611
ANNEX - ENVIROMENTAL INFORMATION