- 74 - All Data Subject To Change Without Notice
www.andersonpower.com
Electrical
Current Rating Amperes ¹ UL 1977 CSA
Wire to Wire (1 AWG) 240 130
Wire to Busbar (2 AWG) 120
Voltage Rating AC/DC
UL1977 600
Dielectric Withstanding Voltage
Volts AC 2,200
Avg. Mated Contact Resistance Milliohms ¹
51/2”of#2AWGwire 0.136
Hot Plug Current Rating Amperes - Wire & Busbar
250 cycles at 120V DC 60A
Mechanical
Wire Size Range AWG mm²
Wire Contacts with Bushings 10 - 1 5.3 - 42.4
Max. Wire Insulation Diameter in. mm
0.600 15.240
Operating Temperature ² °F °C
Standard -4° to 221° -20° to 105°
Chemical Resistant* -40 to 221° -40° to 105°
Mating Cycles No Load by Plating Silver (Ag)
Wire and Busbar Contacts 10,000
Avg. Mating / Unmating Force Lbf. N
Wire to Wire 20 89
Min. Contact / Spring Retention Force
lbf 75
N 333.6
| SB®120 CONNECTOR SPECIFICATIONS |
Materials
Housing
Standard Plastic Resin Polycarbonate
Chem. Resistant Resin Polycarbonate / PBT blend
Contact Retention Spring Stainless Steel
Housing Flammability Rating
UL94 V-0
Glow Wire 960°C (GWFI) / 800°C (GWIT)
Wire & Busbar Contacts
Base Copper Alloy
Plating Silver
Contact Termination Methods
Crimp ³ Wire Contacts
Hand Solder Wire Contacts
Wrench / Socket Busbar Contacts Only
NOTE 1: See IEC 60664-1 for working voltage.
NOTE 2: Amp ratings are stated per position and based on all positions being fully loaded.
¹ Based on: 105°C rated or better cable of the largest size, Properly calibrated APP
recommendedtooling,anda25°Cambienttemperature.ULratingnottoexceed
the maximum operating temperature. CSA rating below a 30°C temperature rise.
²Limitedbythethermalpropertiesoftheconnectorplastichousing.
³ Use APP recommended tooling only. Alternate tools may adversely affect the
performanceofourconnectorsalongwithULandCSArecognition.
Protection
Touch Safety with Wire Contacts
IEC 60529 IP10
Environmental Sealing with Boots
IEC 60529 IP64
Unmated
Mated
Connector
Series Configurations
Creepage/Clearance
per IEC 60950-1
IIIa
Material
Group
SB®120
4.10 mm
4.10 mm
SECTION 3
SB® 120
Attributes SB120
AMP Rating AC/DC 120
Voltage Rating AC/DC (Steady State) 400 V AC/DC ( Operational)
Breaking Capacity -AMP Rating /Cycles 120 Amp/ 10 Cycles
Voltage Rating (Breaking Capacity) 220 VDC
Finger Safety - Mated only IEC 60529 - IP20
Wire Size tested 50 mm²
Contact Series Tested 1323
Climatic Testing (Cold,Heat & MFG) IEC60512Test-11j,11i&11g,
Cycle Life IEC 60512 Test 9a - 5000 Cycles
Mechanical Strength Impact IEC 60512-5 @ 29.5 Inches - dropped 8 times
Temperature Range -20 °C to 105 °C
-4 °F to 221 °F
NOTE 3: Refer to the Constructional Data form for additional
information on our website., www.andersonpower.com
| IEC INFORMATION |