PHYSICAL CHARACTERISTICS
MODELS 4010 thru 4200 • SIZE: 4.1”(104) x 3.1”(78) x 1.4”(36)
MODELS 4300 thru 4330 • SIZE: 4.1”(104) x 3.6”(91) x 1.4”(36)
WEIGHT: 1.5 Pound (.675 kg.) Approx.
CASE MATERIAL: Black Anodized Aluminum
INPUT CONNECTOR: Molex 09-75-2074
MATING CONNECTOR: Molex 09-50-3071 (Supplied)
MOLEX PINS: 08-50-0106
MODELS 4010 thru 4200 • HV LEAD: 30KV 22 AWG
MODELS 4300 thru 4330 • HV LEAD: 40KV 20 AWG
e-mail sales@emcohighvoltage.com
Web site www.e mcohi ghvo ltage. co m Phone (209) 223-3626 Fax (209) 223-2779
11126 Ridge Road, Sutter Creek CA 95685
General Purpose Hi
g
h Volta
g
e Suppl
y
0 to + or - 1,000 through 0 to + or - 33,000 VDC @ 10 Watts
4000 Series
ELECTRICAL SPECIFICATIONS
INPUT VOLTAGE: +24 Volts (+20%- 5%)
OUTPUT VOLTAGE:
See Table
OUTPUT CURRENT:
See Table
REGULATION: Less then 0.2% (No load to full load)
ANALOG CONTROL: 0 to 10 Volts=0 to 100% Output
VOLTAGE MONITOR: 0 to 10 Volts=0 to 100% Output
ON/OFF CONTROL: On=0 Volts or N.C.
Off=5 Volts
REFERENCE OUTPUT: 10 Volts (± 0.5%)
OPERATING TEMP: -10° to +60° C
The 4000 Series is a line of fully
adjustable DC to DC converters
providing an economical source of
high voltage that is ideal for CRT’s,
lasers, Q switches, PMT’s,
detectors, electron and ion guns,
capacitor charging, test equipment,
and many other applications.
These units feature remote voltage
programming, resistance
programming, or manual
adjustability via an externally
accessible potentiometer. Short
circuit protection, arc protection,
and reverse polarity protection are
standard as well as remote on/off
and a 0 to 10 volt output voltage
monitor. These units also feature
excellent EMI/RFI shielding. Two
#6-32 studs mount the supply in a
three inch mounting pattern. Call,
e-mail or fax your requirements for
immediate attention.
OPTIONS
Negative Output Voltage,
put “N” after model
(For example: 4300N)
Output Connector
APPLICATIONS
Cathode Ray Tubes
Lasers and Q Switches
Capacitor Charging
Test Instrumentation
Electrostatic Field Generators
Electrophoresis
FEATURES
0 to 100% Adjustability
Voltage Programmable
Voltage Monitor *
Remote On/Off Control
EMI/RFI Shielding
Short Circuit Protection
Reverse Polarity Protection
Arc Protection
* Excluding Models 4300 & 4330
MODEL OUTPUT
VOLTAGE OUTPUT
CURRENT
RIPPLE
4010 0 to 1,000 10 mA .1%
4020 0 to 2,000 5 mA .1%
4030 0 to 3,000 3.3 m A .1%
4050 0 to 5,000 2 mA .1%
4070 0 to 7,000 1.4 m A .1%
4100 0 to 10,000 1 m A .1%
4120 0 to 12,000 .8 mA .1%
4150 0 to 15,000 . 67 mA .1%
4200 0 to 20,000 .5 mA .2%
4300 0 to 30,000 . 33 mA .2%
4330 0 to 33,000 .30m A .2%
PIN FUNCTION
1 On-Off Control
2 Ground/Case
3 +24 Volt Input
4 10 Volt Reference
5 Programming Voltage
6 Internal Potentiometer
7 Voltage Monitor
Dimensional Tolerances: ± .30 (.76mm)
(Metric equivalents in parentheses)
VOLTAGE: Apply 0-10V to pin 5 for 0-
100% output.
RESISTANCE: Connect potentiometer to pin
4 (reference voltage),
connect wiper arm to pin 5,
and connect potentiometer
to ground.
MANUAL: Connect pin 6 to pin 5, turn
front panel pot for voltage
adjust.
PROGRAMMING
4705K
W e reserve the ri
g
ht to make chan
g