Power Entry Modules
Power Entry Modules
Bolt-in Rear Terminals
Specifications
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high perfor mance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Solder lug and Fast-on tab terminals available
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 25)
UL approved low leakage version also available
Applications
Digital equipment
Personal computers and peripherals
Measuring instr uments
Monitor and display units
60-XXX-010-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-XXX-010-3-4 250VAC 1A .047uF ± 20% 6.0mH 30°C
60-XXX-010-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-XXX-010-5-4 .047uF ± 20%
60-XXX-020-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-XXX-020-3-4 250VAC 2A .047uF ± 20% 2.4mH 30°C
60-XXX-020-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-XXX-020-5-4 .047uF ± 20%
60-XXX-030-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-XXX-030-3-4 250VAC 3A .047uF ± 20% 1.2mH 30°C
60-XXX-030-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-XXX-030-5-4 .047uF ± 20%
60-XXX-060-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-XXX-060-3-4 250VAC 6A .047uF ± 20% 0.53mH 45°C
60-XXX-060-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-XXX-060-5-4 .047uF ± 20%
60-XXX-100-3-2 250VAC 10A 0.35mA 2200pF ± 20% .022uF ± 20% 0.26 mH 45°C
60-XXX-100-5-2 0.50mA 3300pF ± 20%
60-BPR-150-3-11 250VAC 15A 0.35mA 2200pF ± 20% .01uF ± 20% 0.15mH 45°C
Model* Rated Voltage Rated Leakage Current Capacitance Inductance T emperature
(@ 50/60Hz) Current (Max.) CYCX(L1) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
Tested and found to be
IAW VDE 0565 Part 3.
* Substitute BPR or BPS for XXX
BPS - Solder lug terminals
BPR - Fast-on tab ter minals
60-BPR & BPS Series
Circuit Diagram
1
E
2
3
E
4
CX
CY
CY
L1
24
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Power Entry Modules
Bolt-in Rear Terminals
50
Level
Meter
50
13
24
Filter
Oscillator
50
Common Mode
50
Level
Meter
50
13
24
Filter
Oscillator
5050
Normal Mode
2.263 (57.5)
1.476 (37.5)
.252
(6.4)
1.10
(28)
.157
(4)
* General tolerance
± .012 (0.3)
0.807
(20.5)
1.967
(50)
1.573
(40)
1.181
(30)
(2x) .142
(3.6)
.944 (24)
.846
(21.5)
Dimensions in inches (mm)
60-BPX-010;-020;-030
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPX-010-5-X
60-BPX-020-5-X
60-BPX-030-5-X
60-BPX-060;-100
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPX-060-5-X
60-BPX-100-5-X
60-BPX-010;-020;-030
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPX-010-5-X
60-BPX-020-5-X
60-BPX-030-5-X
60-BPX-060;-100
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPX-060-X-4
60-BPX-100-X-2
60-BPX-060-X-2
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
Power Entry Modules
60-BPR & BPS Series
25
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Power Entry Modules
Bolt-in Right Angle Terminals
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high perfor mance
Meets over voltage of IEC 664 categor y II
and complies with IEC 950
Uses IEC connector that meets most safety standards
PCB mounting types available (see page 54)
Length under tab is shor tened for small spaces
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 27)
UL approved low leakage version also available
Applications
Digital equipment
Personal computers and per ipherals
Measuring instr uments
Monitor and display units
Specifications
60-BPF-010-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-BPF-010-3-4 250VAC 1A .047uF ± 20% 6.0mH 30°C
60-BPF-010-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-BPF-010-5-4 .047uF ± 20%
60-BPF-020-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-BPF-020-3-4 250VAC 2A .047uF ± 20% 2.4mH 30°C
60-BPF-020-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-BPF-020-5-4 .047uF ± 20%
60-BPF-030-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-BPF-030-3-4 250VAC 3A .047uF ± 20% 1.2mH 30°C
60-BPF-030-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-BPF-030-5-4 .047uF ± 20%
60-BPF-060-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-BPF-060-3-4 250VAC 6A .047uF ± 20% 0.53mH 45°C
60-BPF-060-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-BPF-060-5-4 .047uF ± 20%
Model Rated Voltage Rated Leakage Current Capacitance Inductance T emperature
(@ 50/60Hz) Current (Max.) CYCX(L1) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
60-BPF Series
1
E
2
3
E
4
CX
CY
CY
L1
Circuit Diagram
Power Entry Modules
26
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Tested and found to be
IAW VDE 0565 Part 3.
Power Entry Modules
Bolt-in Right Angle Terminals
Common Mode Normal Mode
Dimensions in inches (mm)
1.180
(30)
Panel cutout dimensions
mounts from backside
R4.5
1.180 (30)
.865
(22)
1.573 (40) 2- .142
(3.6)
1.967 (50)
1.573 (40)
2- .142
(3.6)
.885
(22.5)
1.463 (37.2)
1.317
(33.5)
()
.991
(25.2)
.590 (15)
.142
(3.6)
.059
(1.5)
.047 (1.2)
1.070
(27.2)
.232 (5.9)
.708
(18)
.024
(.6) .031 (.8)
.779
(19.8)
* General
tolerance
± .012 (.3)
50
Level
Meter
50
13
24
Filter
Oscillator
50
50
Level
Meter
50
13
24
Filter
Oscillator
5050
60-BPF-010;-020
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPF-010-3-X
60-BPF-020-3-X
60-BPF-030;-060
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPF-030-3-X
60-BPF-060-3-X
60-BPF-010;-020
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPF-010-X-4
60-BPF-020-X-4
60-BPF-030;-060
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPF-030-X-4
60-BPF-060-X-4
60-BPF
Fast-on
Terminals
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
60-BPF Series
Power Entry Modules
27
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased miniature filter offers high performance
Meets over voltage of IEC 664 categor y II
and complies with IEC 950
PCB mounting types available (see page 56)
PCB mounting minimizes space and provides
economical installation
Excellent filtering characteristics for high frequencies
Ear th coil standard
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 29)
Applications
Digital equipment
Personal computers and per ipherals
Measuring instr uments
Monitor and display units
Power Entry Modules
High Frequency Attenuation
Specifications
0.35mA 2200pF ± 20% 0.1uF ± 20%
250VAC 1A .047uF ± 20% 6mH 18.3uH 30°C
0.50mA 3300pF ± 20% 0.1uF ± 20%
.047uF ± 20%
0.35mA 2200pF ± 20% 0.1uF ± 20%
250VAC 2A .047uF ± 20% 2.4mH 18.3uH 30°C
0.50mA 3300pF ± 20% 0.1uF ± 20%
.047uF ± 20%
0.35mA 2200pF ± 20% 0.1uF ± 20%
250VAC 3A .047uF ± 20% 1.2mH 18.3uH 30°C
0.50mA 3300pF ± 20% 0.1uF ± 20%
.047uF ± 20%
0.35mA 2200pF ± 20% 0.1uF ± 20%
250VAC 6A .047uF ± 20% .53mH 18.3uH 45°C
0.50mA 3300pF ± 20% 0.1uF ± 20%
.047uF ± 20%
Model Rated Voltage Rated Leakage Current Capacitance Inductance T emperature
(@ 50/60Hz) Current (Max.) CYCX(L1) (L2) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
60-BHS Series
60-BHS-010-3-11
60-BHS-010-3-4
60-BHS-010-5-11
60-BHS-010-5-4
60-BHS-020-3-11
60-BHS-020-3-4
60-BHS-020-5-11
60-BHS-020-5-4
60-BHS-030-3-11
60-BHS-030-3-4
60-BHS-030-5-11
60-BHS-030-5-4
60-BHS-060-3-11
60-BHS-060-3-4
60-BHS-060-5-11
60-BHS-060-5-4
1
E
2
3
E
4
CX
CY
CY
L1
L2
Circuit Diagram
Power Entry Modules
28
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Tested and found to be
IAW VDE 0565 Part 3.
Common Mode Normal Mode
Dimensions in inches (mm)
1.180
(30)
Panel cutout dimensions
mounts from backside
R4.5
1.180 (30)
.865
(22)
1.573 (40) 2- .142
(3.6)
1.967 (50)
1.573 (40)
2- .142
(3.6)
.885
(22.5)
1.534 (39)
1.389
(35.3)
.098
(2.5)
.031 (.8)
.779
(19.8)
1.180
(30)
50
Level
Meter
50
13
24
Filter
Oscillator
50
Insertion Loss (dB)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 12 510 20 50
90
60-BHS-060-X-11
60-BHS-030-X-11
60-BHS-020-X-11
60-BHS-010-X-11
Insertion Loss (dB)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 12 510 20 50
90
60-BHS-060-X-4
60-BHS-030-X-4
60-BHS-020-X-4
60-BHS-010-X-4
Insertion Loss (dB)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 12 510 20 50
90
60-BHS-060-3-11
60-BHS-030-3-11
60-BHS-010-3-11
60-BHS-020-3-11
50
Level
Meter
50
13
24
Filter
Oscillator
5050
Insertion Loss (dB)
80
70
60
50
40
30
20
10
0
Frequency (MHz)
0.1 0.2 0.5 12 510 20 50
90
60-BHS-060-3-4
60-BHS-030-3-4
60-BHS-010-3-4
60-BHS-020-3-4
60-BHS-XXX-X-11
60-BHS-XXX-X-4 60-BHS-XXX-3-4
60-BHS-XXX-3-11
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
Power Entry Modules
High Frequency Attenuation
60-BHS Series
Power Entry Modules
29
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Figure
A
C
A
C
B
A
C
B
A
B
Inductance
(L1)
3.0mH
1.5mH
0.5mH
1.5mH
0.5mH
1.5mH
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
30
Power Entry Modules
Power Entry Modules
Bolt-in Rear Terminals
For General Purpose Applications
Specifications
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high perfor mance
Meets over voltage of IEC 664 categor y II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Operating temperature: -25°C to +70°C
Compact configuration
Applications
Digital equipment
Personal computers and per ipherals
Measuring instr uments
Monitor and display units
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
10-BPF Series
Circuit Diagram
CXL1CY
CY
CX
3
CXL1CY
CY
CX
2
CXL1CY
CY
1
Model
10-BPF-001-5-A
10-BPF-001-5-C
10-BPF-003-5-A
10-BPF-003-5-C
10-BPF-003-5-D
10-BPF-006-5-A
10-BPF-006-5-C
10-BPF-006-5-D
10-BPF-010-5-A
10-BPF-010-5-D
Rated
Voltage
(@ 50/60Hz)
120/250VAC
Rated
Current
1A
3A
6A
10A
Leakage
Current
(Max.)
0.50mA
CY
3300pF
4700pF
3300pF
3300pF & 0.01uF
3300pF
3300pF & 0.01uF
CX
2200pF
0.01uF
3300pF & 0.01uF
0.01uF
3300pF & 0.01uF
Circuit
Diagram
1
2
1
2
1
3
Temperature
Rise
(Max.)
30°C
Capacitance
1.9
(50)
.80 (20.5)
+.01 -0.0
1.1 (28.5)
+.01 -0.0
1.6 (40)
±.007
M3 (2X)
1.4 (3.5) (2X)
1.2
(30)
1.6
(40)
.62 (16)
.82 (21) .25
(6.5) 2.0 (51)
1.5 (37.5)
1.1 (28)
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
31
10-BPF Series
50
Level
Meter
50
13
24
Filter
Oscillator
50
Common Mode
50
Level
Meter
50
13
24
Filter
Oscillator
5050
Normal Mode
10-BPF-001;-003
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
10-BPF-001-5-A
10-BPF-001-5-C
10-BPF-003-5-A
10-BPF-003-5-C
10-BPF-006;-010
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
10-BPF-006-5-C
10-BPF-006-5-A
10-BPF-006-5-D
10-BPF-010-5-A
10-BPF-010-5-D
10-BPF-001;-003
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
10-BPF-001-5-A
10-BPF-001-5-C
10-BPF-003-5-A
10-BPF-003-5-C
10-BPF-006;-010
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
10-BPF-006-5-D
10-BPF-006-5-C
10-BPF-006-5-A
10-BPF-010-5-A
10-BPF-010-5-D
Power Entry Modules
Bolt-in Rear Terminals
For General Purpose Applications
1.6
(40)
2.0 (52)
M3 (2X)
2.8 (72)
2.0 (52)
1.4 (37)
Figure C
Figure B
Figure A
Dimensions in inches (mm)
Power Entry Modules
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
32
Power Entry Modules
Power Entry Modules
Bolt-in Rear Terminals
For Medical Purpose Applications
Specifications
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high perfor mance
Meets over voltage of IEC 664 categor y II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Operating temperature: -25°C to +70°C
Compact configuration
Low leakage current
Applications
Digital equipment
Personal computers and per ipherals
Measuring instr uments
Monitor and display units
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
10-BPF Series
Circuit Diagram
1
E
2
3
E
4
CX
L1
Model
10-BPF-001-2-A
10-BPF-003-2-A
10-BPF-006-2-A
Rated
Voltage
(@ 50/60Hz)
120/250VAC
Rated
Current
1A
10A
Leakage
Current
(Max.)
5uA
Capacitance
CX
0.01uF
Inductance
(L1)
3.0mH
1.5mH
0.5mH
Circuit
Diagram
1
Figure
A
Temperature
Rise
(Max.)
30°C
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
33
Power Entry Modules
Bolt-in Rear Terminals
For Medical Purpose Applications
Power Entry Modules
10-BPF Series
0.807
(20.5)
Dimensions in inches (mm)
50
Level
Meter
50
13
24
Filter
Oscillator
50
Common Mode
50
Level
Meter
50
13
24
Filter
Oscillator
5050
Normal Mode
10-BPF-001;-003;-006
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
10-BPF-001-2-A
10-BPF-003-2-A
10-BPF-006-2-A
10-BPF-001;-003;-006
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
10-BPF-001-2-A
10-BPF-003-2-A
10-BPF-006-2-A
1.9
(50) 1.6
(40) 1.2
(30)
.63 (16)
.82 (21) .25
(6.5)
2.0 (51)
1.5 (37.5)
1.1 (28)
.80 (20.5)
+.01 -0.0
1.1 (28.5)
+.01 -0.0
1.6 (40)
±.007
M3 (2X)
1.4 (3.5)
(2X)
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased miniature filter offers high performance
Meets over voltage of IEC 664 categor y II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Snap-in style saves labor and hardware inventory
Wire output minimizes space and provides
economical installation
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 35)
Applications
Digital equipment
Personal computers and per ipherals
Measuring instr uments
Monitor and display units
Specifications
60-SPL-010-3-2 0.35mA 2200pF ± 20% 22nF ± 20%
60-SPL-010-3-3 250VAC 1A 33nF ± 20% 6.0mH 30°C
60-SPL-010-5-2 0.50mA 3300pF ± 20% 22nF ± 20%
60-SPL-010-5-3 33nF ± 20%
60-SPL-020-3-2 0.35mA 2200pF ± 20% 22nF ± 20%
60-SPL-020-3-3 250VAC 2A 33nF ± 20% 2.4mH 30°C
60-SPL-020-5-2 0.50mA 3300pF ± 20% 22nF ± 20%
60-SPL-020-5-3 33nF ± 20%
60-SPL-030-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-SPL-030-3-3 250VAC 3A 3300pF ± 20% 1.2mH 30°C
60-SPL-030-5-2 0.50mA 2200pF ± 20% .033uF ± 20%
60-SPL-030-5-3 3300pF ± 20%
60-SPL-060-3-2 0.35mA 2200pF ± 20% 22nF ± 20%
60-SPL-060-3-3 250VAC 6A 33nF ± 20% 0.53mH 45°C
60-SPL-060-5-2 0.50mA 3300pF ± 20% 22nF ± 20%
60-SPL-060-5-3 33nF ± 20%
Model Rated Voltage Rated Leakage Current Capacitance Inductance T emperature
(@ 50/60Hz) Current (Max.) CYCX(L1) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
60-SPL Series
1
E
2
3
E
4
CX
CY
CY
L1
Circuit Diagram
34
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Tested and found to be
IAW VDE 0565 Part 3.
Power Entry Modules
Snap-in with Wire Leads
Power Entry Modules
Power Entry Modules
Snap-in with Wire Leads
Common Mode Normal Mode
Dimensions in inches (mm)
1.397
(35.5)
.252 (6.4)
1.612 (41)
1.172 (29.8)
4.719 (120)*
.236 (6)
Blue
Green/Yellow
Brown
PVC Insulated wire
UL1617 AWG #22
.963
(24.5)
* Metal case
Tin Plated
* General tolerance
± .012 (.3) .838 (21.3)
R2
W
.853
(21.7)
Panel cutout dimensions
T :Panel Thickness
TW
.039 (1.0) 1.270 (32.3)
.047 (1.2) 1.274 (32.4)
.059 (1.5) 1.285 (32.5)
UL 1015 AWG #18
* Custom lengths available upon request.
50
Level
Meter
50
13
24
Filter
Oscillator
50
60-SPL-010;-020
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-SPL-020-5-X
60-SPL-010-5-X 60-SPL-020-3-X
60-SPL-010-3-X
60-SPL-030;-060
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-SPL-030-5-X
60-SPL-060-5-X
60-SPL-030-3-X
60-SPL-060-3-X
60-SPL-010;-020
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-SPL-010-X-4
60-SPL-020-X-4
60-SPL-010-X-2
60-SPL-020-X-2
50
Level
Meter
50
13
24
Filter
Oscillator
5050
60-SPL-030;-060
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-SPL-030-X-4
60-SPL-060-X-4
60-SPL-030-X-2
60-SPL-060-X-2
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
60-SPL Series
Power Entry Modules
35
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
36
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
1
E
2
3
E
4
CX
CY
CY
L1
Circuit Diagram
Power Entry Modules
Bolt-in with Wire Leads
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case filter offers high performance
Meets over voltage of IEC 664 categor y II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Wire output for minimizing space use
and economical installation
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 37)
Applications
Digital equipment
Personal computers and per ipherals
Measuring instr uments
Monitor and display units
Specifications
60-BPL-010-3-2 0.35mA 2200pF ± 20% 22nF ± 20%
60-BPL-010-3-3 250VAC 1A 33nF ± 20% 6.0mH 30°C
60-BPL-010-5-2 0.50mA 3300pF ± 20% 22nF ± 20%
60-BPL-010-5-3 33nF ± 20%
60-BPL-020-3-2 0.35mA 2200pF ± 20% 22nF ± 20%
60-BPL-020-3-3 250VAC 2A 33nF ± 20% 2.4mH 30°C
60-BPL-020-5-2 0.50mA 3300pF ± 20% 22nF ± 20%
60-BPL-020-5-3 33nF ± 20%
60-BPL-030-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-BPL-030-3-3 250VAC 3A 3300pF ± 20% 1.2mH 30°C
60-BPL-030-5-2 0.50mA 2200pF ± 20% .033uF ± 20%
60-BPL-030-5-3 3300pF ± 20%
60-BPL-060-3-2 0.35mA 2200pF ± 20% 22nF ± 20%
60-BPL-060-3-3 250VAC 6A 33nF ± 20% 0.53mH 45°C
60-BPL-060-5-2 0.50mA 3300pF ± 20% 22nF ± 20%
60-BPL-060-5-3 33nF ± 20%
Model Rated Voltage Rated Leakage Current Capacitance Inductance T emperature
(@ 50/60Hz) Current (Max.) CYCX(L1) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
60-BPL Series
Power Entry Modules
Tested and found to be
IAW VDE 0565 Part 3.
Power Entry Modules
Bolt-in with Wire Leads
Common Mode Normal Mode
Dimensions in inches (mm)
1.612 (41)
.252 (6.4) 1.172
(29.8)
* General tolerance
±.012 (0.3)
Panel cutout dimensions
mounts from front side
R3.5
1.239 (31.5)
.885
(22.5)
.837
(21.3)
1.573 (40)
2- .118 (M3)
Panel cutout dimensions
mounts from back side
R4.5
1.180 (30)
.865
(22)
1.573 (40) 2- .130 (3.3)
1.967
(50)
1.573
(40)
1.160
(29.5)
2- .142
(3.6)
.944 (24)
.830
(21.1)
4.719 (120)*
BLUE
GREEN/YELLOW
BROWN
PVC Insulated wire
UL1617 AWG #22
UL1015 AWG # 18
.236 (6)
* Custom lengths available upon request.
50
Level
Meter
50
13
24
Filter
Oscillator
50
60-BPL-010;-020
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPL-020-5-X
60-BPL-010-5-X
60-BPL-020-3-X
60-BPL-010-3-X
60-BPL-030;-060
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPL-030-5-X
60-BPL-060-5-X
60-BPL-030-3-X
60-BPL-060-3-X
60-BPL-030;-060
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPL-030-X-4
60-BPL-060-X-2
60-BPL-030-X-2
60-BPL-060-X-4
60-BPL-010;-020
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-BPL-010-X-4
60-BPL-020-X-4
60-BPL-010-X-2
60-BPL-020-X-2
50
Level
Meter
50
13
24
Filter
Oscillator
5050
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
60-BPL Series
Power Entry Modules
37
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
38
1
E
2
3
E
4
CX
CY
CY
L1
Circuit Diagram
Power Entry Modules
Bolt-in with Wire Leads
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case filter offers high performance
Meets over voltage of IEC 664 categor y II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Wire output for minimizing space use
and economical installation
Operating temperature: -25°C to +70°C
Compact configuration
Applications
Digital equipment
Personal computers and per ipherals
Measuring instr uments
Monitor and display units
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
10-BPL Series
Power Entry Modules
Specifications
Model
10-BPL-001-5-B
10-BPL-003-5-B
10-BPL-006-5-B
Rated
Voltage
(@ 50/60Hz)
250VAC
Rated
Current
1A
3A
6A
Leakage
Current
(Max.)
0.50mA
CY
3300pF
CX
0.01uF
Inductance
(L1)
3.0mH
1.5mH
0.5mH
Circuit
Diagram
1
Figure
A
Temperature
Rise
(Max.)
30°C
Capacitance
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
39
Power Entry Modules
Bolt-in with Wire Leads
Dimensions in inches (mm)
10-BPL Series
Power Entry Modules
50
Level
Meter
50
13
24
Filter
Oscillator
50
Common Mode
50
Level
Meter
50
13
24
Filter
Oscillator
5050
Normal Mode
10-BPL-001;-003;-006
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
10-BPL-001-5-B
10-BPL-006-5-B
10-BPL-003-5-B
10-BPL-001;-003;-006
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
10-BPL-001-5-B
10-BPL-006-5-B
10-BPL-003-5-B
1.9
(50) 1.6
(40) 1.2
(30)
1.4 (3.5)
(2X)
.63 (16)
.82 (21) .25
(6.5)
2.0 (51)
1.5 (37.5)
1.1 (28)
.80 (20.5)
+.01 -0.0
1.1 (28.5)
+.01 -0.0
1.6 (40)
±.007
M3 (2X)
Figure A
Power Entry Modules
Snap-in Mount
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased miniature filter offers high perfor mance
Meets over voltage of IEC 664 categor y II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Snap-in style saves labor and hardware inventory
Solder lug and fast-on tab terminations available
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 41)
UL approved low leakage version also available
Applications
Digital equipment
Personal computers and per ipherals
Measuring instr uments
Monitor and display units
Specifications
60-XXX-010-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-XXX-010-3-4 250VAC 1A .047uF ± 20% 6.0mH 30°C
60-XXX-010-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-XXX-010-5-4 .047uF ± 20%
60-XXX-020-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-XXX-020-3-4 250VAC 2A .047uF ± 20% 2.4mH 30°C
60-XXX-020-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-XXX-020-5-4 .047uF ± 20%
60-XXX-030-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-XXX-030-3-4 250VAC 3A .047uF ± 20% 1.2mH 30°C
60-XXX-030-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-XXX-030-5-4 .047uF ± 20%
60-XXX-060-3-2 0.35mA 2200pF ± 20% .022uF ± 20%
60-XXX-060-3-4 250VAC 6A .047uF ± 20% 0.53mH 45°C
60-XXX-060-5-2 0.50mA 3300pF ± 20% .022uF ± 20%
60-XXX-060-5-4 .047uF ± 20%
Model* Rated Voltage Rated Leakage Current Capacitance Inductance T emperature
(@ 50/60Hz) Current (Max.) CYCX(L1) Rise (Max.)
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
60-SPR & SPS Series
* Substitute SPR or SPS for XXX
60-SPR - Fast-on ter minals
60-SPS - Solder lug terminals
60-XXX-100-3-2 250VAC 10A 0.35mA 2200pF ± 20% .022uF ± 20% 0.26 mH 45°C
60-XXX-100-5-2 0.50mA 3300pF ± 20%
1
E
2
3
E
4
CX
CY
CY
L1
Circuit Diagram
Power Entry Modules
40
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Tested and found to be
IAW VDE 0565 Part 3.
60-SPR-150-3-11 250VAC 15A 0.35mA 2200pF ± 20% .01uF ± 20% 0.15mH 45°C
Power Entry Modules
Snap-in Mount
Common Mode Normal Mode
1.395
(35.5)
2.033 (51.7)
1.805 (45.9)
1.418 (35.9)
.252 (6.4)
1.172
(29.8)
.157
(4)
Solder Lug
2 X 3 hole
* Standard terminal
Fast-on tab #250
available as
SPR series
2.096 (53.3)
* General tolerance
± .012 (0.3)
Panel cutout dimensions
for 1.0t chassis
R2
.853
(21.7)
.837
(21.3)
.963
(24.5)
W
Panel cutout dimensions T: Panel Thickness
TW
.039 (1.0) 1.270 (32.3)
.047 (1.2) 1.274 (32.4)
.059 (1.5) 1.285 (32.5)
Solder lugs shown. Also available in fast-ons.
50
Level
Meter
50
13
24
Filter
Oscillator
50
60-SPX-010;-020;-030
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-SPX-010-5-X
60-SPX-020-5-X
60-SPX-030-5-X
60-SPX-060;-100
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-SPX-60-5-X
60-SPX-100-5-X
60-SPX-060;-100
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-SPX-060-X-4
60-SPX-100-X-2
60-SPX-060-X-2
60-SPX-010;-020;-030
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
60-SPX-010-X-4
60-SPX-030-X-4
60-SPX-020-X-4
50
Level
Meter
50
13
24
Filter
Oscillator
5050
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
60-SPR & SPS Series
Power Entry Modules
41
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Dimensions in inches (mm)
Features
Nor th Amer ican and Metric fuse
holders available
Fuse holder provides effective EMI suppression
of common and differential mode
Suitable for products that must confor m
to FCC and FTZ requirements
Meets over voltage categor y II of IEC 664
and complies with IEC 950
Fast-on ter minals or solder lug ter minals
Metal case provides effective EMI shielding
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 43)
Applications
Computers and peripheral equipment
Electronic equipment
Digital equipment
Measuring and testing instr uments
Telecommunications equipment
Model* Rated Voltage Rated Leakage Current Capacitance Inductance T emperature
(@ 50/60Hz) Current (Max.) CYCX(L1) Rise (Max.)
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 Mmin. at 500VDC
F(S) = Fast-on or (Solder lug ter minals)
Voltage Drop: 1V max. at rated current
Weight: 78g
Inlet: Compatible with IEC-320
Specifications
64-XXX-020-3-11
0.35mA
0.50mA 2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
64-XXX-020-5-11
250VAC 2A 0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
4A
6A
40°C
45°C
45°C
40°C
45°C
45°C
6.5mH
4.2mH
1.6mH
6.5mH
4.2mH
1.6mH
2A
4A
6A
250VAC
250VAC
125VAC
125VAC
125VAC
64-XXX-020-3-12
64-XXX-020-5-12
64-XXX-040-3-11
64-XXX-040-5-11
64-XXX-040-3-12
64-XXX-040-5-12
64-XXX-060-3-11
64-XXX-060-5-11
64-XXX-060-3-12
64-XXX-060-5-12
65-XXX-020-3-11
65-XXX-020-5-11
65-XXX-020-3-12
65-XXX-020-5-12
65-XXX-040-3-11
65-XXX-040-5-11
65-XXX-040-3-12
65-XXX-040-5-12
65-XXX-060-3-11
65-XXX-060-5-11
65-XXX-060-3-12
65-XXX-060-5-12
Fused Filtered
Power Entry Modules
For General Purpose Applications
Circuit Diagram
L
N
L
N
EE
L1
RC
X
CY
CY
Fused Filtered
Power Entry Modules
42
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Tested and found to be
IAW VDE 0565 Part 3.
* Substitute BFF or BFS for XXX
BFF - Fast-on ter minals
BFS - Solder lug terminals
64-65-BFF/64-65-BFS Series
50
Level
Meter
50
13
24
Filter
Oscillator
50
Common Mode
50
Level
Meter
50
13
24
Filter
Oscillator
5050
Normal Mode
Dimensions in inches (mm)
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
0.35 mA Leakage Versions
0.50 mA Leakage Versions
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 12 510 20 50
90
2 Amp
4 Amp
6 Amp
10
0.50 mA Leakage Versions
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 12 510 20 50
90
2 Amp
4 Amp 6 Amp
10
0.35 mA Leakage Versions
Fuse cover
1.376
(35)
1.298
(33) 2 - .13
(2 - 3.3 )
Hole
1.738 (44.2)
1.416±.008
(36±0.2)
1.101 (28)
1.616 (41.1) 1.14
(29)
1.29
(32.8)
Fast-on tab#250
t= .031 (0.8)
2.32 (59)
.098 (2.5)
0.252 (6.4)
* General Tolerance:
±.020 (0.5)
* Metal Case
+0.2
-0.1
0.158
(4.0)
2.249 (L:57.2)
+.008
-.004
* Alternate Terminal for 64/65-BFS-Solder Lug Terminal
Fused Filtered
Power Entry Modules
For General Purpose Applications
Dimensions
64/65-BFF Series
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
64-65-BFF/64-65-BFS Series
Fused Filtered
Power Entry Modules
43
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Applications
Medical equipment
Electronic equipment
Digital equipment
Industrial equipment
Features
Metric and North Amer ican fuse
holders available
Fuse holder provides effective EMI suppression
of common and differential mode
Suitable for products that must confor m
to FCC and FTZ requirements
Meets over voltage categor y II of IEC 664
and complies with IEC 950
Fast-on ter minations or solder lug ter minations
Metal case provides effective EMI shielding
Provides susceptibility protection without the leakage
current associated with line-to-ground capacitance
Reduces the line to ground capacitance in order
to meet patient care requirements
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 45)
Telecommunications equipment
Measuring and testing instr uments
Personal computers
and peripherals
Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
L
N
L
N
EE
L
N
L
N
EE
LINE
LOAD
LINE
LOAD
RC
X
L
1
RC
X
L
1
C
Y
C
Y
Circuit Diagrams
66/67-BFF(S)-XXX-1-X Filter 66/67-BFF(S)-XXX-0-X and
66/67-BFF(S)-XXX-4-X Filters
Fused Filtered
Power Entry Modules
44
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Tested and found to be
IAW VDE 0565 Part 3.
Model* Rated Voltage Rated Leakage Current Capacitance Inductance T emperature
(@ 50/60Hz) Current (Max.) CYCX(L1) Rise (Max.)
Specifications
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 Mmin. at 500VDC
F(S) = Fast-on or (Solder lug ter minals)
Voltage Drop: 1V max. at rated current
Weight: 78g
Inlet: Compatible with IEC-320
* Substitute BFF or BFS for XXX
BFF - Fast-on ter minals
BFS - Solder lug terminals
66-XXX-020-1-11
66-XXX-020-1-12
66-XXX-020-0-11
66-XXX-020-4-11
66-XXX-020-0-12
66-XXX-020-4-12
66-XXX-040-1-11
66-XXX-040-1-12
66-XXX-040-0-11
66-XXX-040-4-11
66-XXX-040-0-12
66-XXX-040-4-12
66-XXX-060-1-11
66-XXX-060-1-12
66-XXX-060-0-11
66-XXX-060-4-11
66-XXX-060-0-12
66-XXX-060-4-12
67-XXX-020-1-11
67-XXX-020-1-12
67-XXX-020-0-11
67-XXX-020-4-11
67-XXX-020-0-12
67-XXX-020-4-12
67-XXX-040-1-11
67-XXX-040-1-12
67-XXX-040-0-11
67-XXX-040-4-11
67-XXX-040-0-12
67-XXX-040-4-12
67-XXX-060-1-11
67-XXX-060-1-12
67-XXX-060-0-11
67-XXX-060-4-11
67-XXX-060-0-12
67-XXX-060-4-12
250VAC 2A 40°C6.5mH
4.2mH
1.6mH
6.5mH
4.2mH
1.6mH
45°C
45°C
40°C
45°C
45°C
0.01mA none
none
none
none
none
none
0.1mA
0.1mA
0.075mA 0.22uF
0.1uF
0.1uF
0.22uF
0.22uF
0.1uF
0.1uF
0.22uF
0.22uF
0.1uF
0.1uF
0.22uF
0.22uF
0.1uF
0.1uF
0.22uF
0.22uF
0.1uF
0.1uF
0.22uF
0.22uF
0.1uF
0.1uF
0.22uF
330pF ± 20%
470pF ± 20%
330pF ± 20%
470pF ± 20%
330pF ± 20%
470pF ± 20%
330pF ± 20%
470pF ± 20%
330pF ± 20%
470pF ± 20%
330pF ± 20%
470pF ± 20%
330pF ± 20%
470pF ± 20%
330pF ± 20%
470pF ± 20%
330pF ± 20%
470pF ± 20%
330pF ± 20%
470pF ± 20%
330pF ± 20%
470pF ± 20%
330pF ± 20%
470pF ± 20%
0.075mA
0.01mA
0.1mA
0.1mA
0.075mA
0.075mA
0.01mA
0.1mA
0.1mA
0.075mA
0.075mA
0.005mA
0.05mA
0.05mA
0.035mA
0.035mA
0.005mA
0.05mA
0.05mA
0.035mA
0.035mA
0.005mA
0.05mA
0.05mA
0.035mA
0.035mA
4A
6A
2A
4A
6A
250VAC
250VAC
125VAC
125VAC
125VAC
66-67-BFF/66-67-BFS Series
50
Level
Meter
50
13
24
Filter
Oscillator
5050
50
Level
Meter
50
13
24
Filter
Oscillator
50
0.075 and 0.1 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
0.075 and 0.1 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp 4 Amp
Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
Common Mode Normal Mode
Dimensions in inches (mm)
0.01 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
0.01 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
Fuse cover
1.376
(35)
1.298
(33) 2 - .13
(2 - 3.3 )
Hole
1.738 (44.2)
1.416±.008
(36±0.2)
1.101 (28)
1.616 (41.1) 1.14
(29)
1.29
(32.8)
Fast-on tab#250
t= .031 (0.8)
2.32 (59)
.098 (2.5)
0.252 (6.4)
* General Tolerance:
±.020 (0.5)
* Metal Case
+0.2
-0.1
0.158
(4.0)
2.249 (L:57.2)
+.008
-.004
* Alternate Terminal for 66/67-BFS-Solder Lug Terminal
Dimensions
66-67-BFF/66-67-BFS Series
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
66-67-BFF/66-67-BFS Series
Temperature Characteristics
Fused Filtered
Power Entry Modules
45
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Circuit Diagram
L
N
L
N
EE
RCX
CY
CY
CX
Features
Nor th Amer ican and Metric fuse
holders available
Fuse holder and double pole power ON/OFF switch
provided in a convenient/compact package
Suitable for products that must confor m
to FCC and FTZ requirements
Meets over voltage categor y II of IEC 664
and complies with IEC 950
Metal case provides effective EMI shielding
Easy access fuse drawer with space for spare fuse
Flange-mounted or snap-in styles available
for quick mounting
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 47)
Switched and Fused Filtered
Power Entry Modules
For General Purpose Applications
Switched and Fused Filtered
Power Entry Modules
46
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Tested and found to be
IAW VDE 0565 Part 3.
Applications
Computers and
peripheral equipment
Electronic equipment
Digital equipment
Measuring and testing instr uments
Telecommunications equipment
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 Mmin. at 500VDC
B(S) = Bolt-in terminals or (Snap-in ter minals)
Voltage Drop: 1V max. at rated current
Weight: 130g
Inlet: Compatible with IEC-320
* Substitute BSF or SSF for XXX
BSF - Bolt-in switched and fused
SSF - Snap-in switched and fused
Specifications
Model* Rated Voltage Rated Leakage Current Capacitance Inductance T emperature
(@ 50/60Hz) Current (Max.) CYCX1 CX2 (L1) Rise (Max.)
64-XXX-020-3-12
64-XXX-020-3-04
64-XXX-020-3-14
64-XXX-020-3-06
64-XXX-020-5-12
64-XXX-020-5-04
64-XXX-020-5-14
64-XXX-020-5-06
64-XXX-040-3-12
64-XXX-040-3-04
64-XXX-040-3-14
64-XXX-040-3-06
64-XXX-040-5-12
64-XXX-040-5-04
64-XXX-040-5-14
64-XXX-040-5-06
64-XXX-060-3-12
64-XXX-060-3-04
64-XXX-060-3-14
64-XXX-060-3-06
64-XXX-060-5-12
64-XXX-060-5-04
64-XXX-060-5-14
64-XXX-060-5-06
65-XXX-020-3-12
65-XXX-020-3-04
65-XXX-020-3-14
65-XXX-020-3-06
65-XXX-020-5-12
65-XXX-020-5-04
65-XXX-020-5-14
65-XXX-020-5-06
65-XXX-040-3-12
65-XXX-040-3-04
65-XXX-040-3-14
65-XXX-040-3-06
65-XXX-040-5-12
65-XXX-040-5-04
65-XXX-040-5-14
65-XXX-040-5-06
65-XXX-060-3-12
65-XXX-060-3-04
65-XXX-060-3-14
65-XXX-060-3-06
65-XXX-060-5-12
65-XXX-060-5-04
65-XXX-060-5-14
65-XXX-060-5-06
250VAC
250VAC
250VAC
125VAC
125VAC
125VAC
2A 45°C10.5mH
10.5mH
4.2mH
4.2mH
1.6mH
1.6mH
45°C
45°C
45°C
45°C
45°C
0.35mA 2200pF
3300pF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
2200pF
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
4A
6A
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
NONE
0.22uF
NONE
0.47uF
2A
4A
6A
64-65-BSF/64-65-SSF Series
50
Level
Meter
50
13
24
Filter
Oscillator
50
Common Mode
50
Level
Meter
50
13
24
Filter
Oscillator
5050
Normal Mode
.248
(6.3)
2.556
(65)
2.348
(59.7)
1.313 (33.4)
1.101 (28)
Fast-on tab #250
2.273 (57.8)
1.133
(28.8)
2.340
(59.5)
Panel cutout dimension
mount from back side
1.514 (38.8)
A
R .079
(2.0) Thickness of Panel A
.031 (0.8t) 2.430 (61.8±0.1)
.039 (1.0t) 2.446 (62.2±0.1)
.047 (1.2t) 2.462 (62.6±0.1)
.059 (1.5t) 2.470 (62.8±0.1)
.071 (1.8t) 2.473 (62.9±0.1)
.079 (2.0t) 2.477 (63.0±0.1)
* General Tolerance
± .039 (1.0)
* Metal Case
1.16
(29.5 )
+0.5
-0
+.02
-0
t= .031 (0.8)
Dimensions in inches (mm)
0.35 mA Leakage Versions
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
2 Amp
4 Amp
6 Amp
90
0.50 mA Leakage Versions
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
2 Amp
4 Amp
6 Amp
90
64/65-B(S)SF-*-*-02(04,06)
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 12 510 20 50
6 Amp
90
100
4 Amp
2 Amp
64/65-B(S)SF-*-*-11(12,14)
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 12 510 20 50
6 Amp
90
100
4 Amp
2 Amp
.248
(6.3)
2.556
(65)
2.348
(59.7) Ø.142
(3.6)
1.947 (49.5)
1.573 (40±0.2)
1.101 (28)
F ast-on Tab #250
2.273 (57.8) 1.133
(28.8)
2.340
(59.5)
1.573
(40.±0.2)
2.399 (61)
Panel cutout
dimension
mount from
back side
R .059
(1.5)
2 - .142
(3.6) Hole
1.526 (38.8)
1.16±
(29.5± )
0.5
0
.334
0
t= .031 (0.8)
Switched and Fused Filtered
Power Entry Modules
For General Purpose Applications
64/65-SSF Series
Dimensions
64/65-BSF Series
Temperature Characteristics
Switched and Fused Filtered
Power Entry Modules
47
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
L
N
L
N
EE
C
Y1
C
Y2
LINE
LOAD
RCX1
L1CX2
Note: C
Y1
and C
Y2
capacitors
omitted on 66/67
B(S)F-XXX-1-X Filters
Circuit Diagram
Weight: 130g
Inlet: Compatible with IEC-320
B(S) = Bolt-in terminals or (Snap-in ter minals)
* Substitute BSF or SSF for XXX
BSF - Bolt-In Switched and Fused
SSF - Snap-In Switched and Fused
Features
Metric and Nor th Amer ican fuse holders available
Fuse holder and a double pole power ON/OFF switch
provides a convenient/compact package
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage categor y II of IEC 664
and complies with IEC 950
Provides susceptibility protection without the leakage
current associated with line-to-ground capacitors
Designed to meet requirements for non-patient
and patient care equipment
Metal case provides effective EMI shielding
Easy access fuse drawer - space for spare fuse
Flange-mounted or snap-in styles available
for quick mounting
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 49)
Applications
Medical equipment
Industrial equipment
Telecommunications equipment
Measuring and testing instruments
Digital equipment (including
switching power supplies)
General purpose filter for
susceptibility or high frequency
clean upapplications
Switched and Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
48
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
10.5mH
4.2mH
1.6mH
2A
4A
6A
125
VAC
40°C
45°C
67-XXX-020-0-12
67-XXX-020-0-04
67-XXX-020-0-14
67-XXX-020-0-06
67-XXX-020-1-12
67-XXX-020-1-04
67-XXX-020-1-14
67-XXX-020-1-06
67-XXX-020-4-12
67-XXX-020-4-04
67-XXX-020-4-14
67-XXX-020-4-06
67-XXX-040-0-12
67-XXX-040-0-04
67-XXX-040-0-14
67-XXX-040-0-06
67-XXX-040-1-12
67-XXX-040-1-04
67-XXX-040-1-14
67-XXX-040-1-06
67-XXX-040-4-12
67-XXX-040-4-04
67-XXX-040-4-14
67-XXX-040-4-06
67-XXX-060-0-12
67-XXX-060-0-04
67-XXX-060-0-14
67-XXX-060-0-06
67-XXX-060-1-12
67-XXX-060-1-04
67-XXX-060-1-14
67-XXX-060-1-06
67-XXX-060-4-12
67-XXX-060-4-04
67-XXX-060-4-14
67-XXX-060-4-06
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
Note: Test Voltage: 1500VAC one minute, line to ground
Insulation Resistance: 300 Mmin. at 500VDC
Voltage Drop: 1V max. at rated current
Rated Rated Leakage
Temp.
Model*
Voltage Current Current
Capacitance Induct. Rise
50/60Hz (Max.)
CYCX1 CX2 (L1) (Max.)
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
330pF
NONE
470pF
330pF
NONE
470pF
330pF
NONE
470pF
0.04mA
.005mA
0.05mA
0.04mA
.005mA
0.05mA
0.04mA
.005mA
0.05mA
Specifications
10.5mH
4.2mH
1.6mH
2A
4A
6A
250
VAC
40°C
45°C
66-XXX-020-0-12
66-XXX-020-0-04
66-XXX-020-0-14
66-XXX-020-0-06
66-XXX-020-1-12
66-XXX-020-1-04
66-XXX-020-1-14
66-XXX-020-1-06
66-XXX-020-4-12
66-XXX-020-4-04
66-XXX-020-4-14
66-XXX-020-4-06
66-XXX-040-0-12
66-XXX-040-0-04
66-XXX-040-0-14
66-XXX-040-0-06
66-XXX-040-1-12
66-XXX-040-1-04
66-XXX-040-1-14
66-XXX-040-1-06
66-XXX-040-4-12
66-XXX-040-4-04
66-XXX-040-4-14
66-XXX-040-4-06
66-XXX-060-0-12
66-XXX-060-0-04
66-XXX-060-0-14
66-XXX-060-0-06
66-XXX-060-1-12
66-XXX-060-1-04
66-XXX-060-1-14
66-XXX-060-1-06
66-XXX-060-4-12
66-XXX-060-4-04
66-XXX-060-4-14
66-XXX-060-4-06
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
Rated Rated Leakage
Temp.
Model*
Voltage Current Current
Capacitance Induct. Rise
50/60Hz (Max.)
CYCX1 CX2 (L1) (Max.)
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
330pF
NONE
470pF
330pF
NONE
470pF
330pF
NONE
470pF
.075mA
.01mA
0.1mA
.075mA
.01mA
.01mA
.075mA
.01mA
0.1mA
Tested and found to be
IAW VDE 0565 Part 3
Switched and Fused Filtered
Power Entry Modules
66-67-BSF/66-67-SSF Series
50
Level
Meter
50
13
24
Filter
Oscillator
5050
50
Level
Meter
50
13
24
Filter
Oscillator
50
0.075 and 0.1 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
0.075 and 0.1 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
Switched and Fused Filtered
Power Entry Modules
For Medical or General Purpose Applications
Common Mode Normal Mode
0.01 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
0.01 mA Leakage Current
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
90
2 Amp
6 Amp
4 Amp
Dimensions
.248
(6.3)
2.556
(65)
2.348
(59.7)
1.313 (33.4)
1.101 (28)
Fast-on tab #250
2.273 (57.8)
1.133
(28.8)
2.340
(59.5)
Panel cutout dimension
mount from back side
1.514 (38.8)
A
R .079
(2.0) Thickness of Panel A
.031 (0.8t) 2.430 (61.8±0.1)
.039 (1.0t) 2.446 (62.2±0.1)
.047 (1.2t) 2.462 (62.6±0.1)
.059 (1.5t) 2.470 (62.8±0.1)
.071 (1.8t) 2.473 (62.9±0.1)
.079 (2.0t) 2.477 (63.0±0.1)
* General Tolerance
± .039 (1.0)
* Metal Case
1.16
(29.5 )
+0.5
-0
+.02
-0
t= .031 (0.8)
.248
(6.3)
2.556
(65)
2.348
(59.7) Ø.142
(3.6)
1.947 (49.5)
1.573 (40±0.2)
1.101 (28)
F ast-on Tab #250
2.273 (57.8) 1.133
(28.8)
2.340
(59.5)
1.573
(40.±0.2)
2.399 (61)
Panel cutout
dimension
mount from
back side
R .059
(1.5)
2 - .142
(3.6) Hole
1.526 (38.8)
1.16
(29.5 )
+0.5
-0
+.02
-0
t= .031 (0.8)
66/67-BSF Series 66/67-SSF Series
Dimensions in inches (mm)
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
49
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Switched and Fused Filtered
Power Entry Modules
Features
Dual fuse for European applications
Fuse holder and double pole power ON/OFF switch
provides a convenient/compact package
Suitable for products that must confor m
to FCC and FTZ requirements
Meets over voltage categor y II of IEC 664
and complies with IEC 950
Metal case provides effective EMI shielding
IEC connector meets the safety standards of most
cer tifying agencies
Easy access fuse drawer
Flange-mounted
UL, CSA, and SEMKO approved
Designed to be in accordance with VDE 0565, part 3
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page 51)
Applications
Computers and peripheral equipment
Electronic equipment
Digital equipment
Measuring and testing instr uments
Telecommunications equipment
Switched and Fused Filtered
Power Entry Modules
Dual Fuse for European Applications
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 Mmin. at 500VDC
Voltage Drop: 1V max. at rated current
Weight: 130g
Inlet: Compatible with IEC-320
B(S) = Bolt-in terminals or (Snap-in ter minals)
L
N
L
N
E E
C
Y1
C
Y2
C
X2
L
1
L
2
C
X1
R
1
SW
FUSE
Circuit Diagram
50
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
Specifications
68-BSF-020-3-01 2A 0.1uF 0.1uF 10.5mH
68-BSF-020-3-04 0.22uF 0.22uF
68-BSF-040-3-01 250VAC 4A 0.35mA 2200pF 2200pF 0.1uF 0.1uF 4.2mH 45°C
68-BSF-040-3-04 0.22uF 0.22uF
68-BSF-060-3-01 6A 0.1uF 0.1uF 1.6mH
68-BSF-060-3-04 0.22uF 0.22uF
Model Rated Voltage Rated Leakage Current Capacitance Inductance T emperature
(@ 50/60Hz) Current (Max.) CY1 CY2 CX1 CX2 (L1) Rise (Max.)
Switched and Fused Filtered
Power Entry Modules
68-BSF Series
Switched and Fused Filtered
Power Entry Modules
Dual Fuse for European Applications
120
100
80
60
40
20
020 30 40 50 60 70 80 90
Ambient Temperature (°C)
Current (%)
Temperature Characteristics
.248
(6.3)
2.556
(65)
2.348
(59.7) Ø.142
(3.6)
1.947 (49.5)
1.573 (40±0.2)
1.101 (28)
F ast-on Tab #250
2.273 (57.8) 1.133
(28.8)
2.340
(59.5)
1.573
(40.±0.2)
2.399 (61)
Panel cutout
dimension
mount from
back side
R .059
(1.5)
2 - .142
(3.6) Hole
1.526 (38.8)
1.16
(29.5 )
+0.5
-0
+.02
-0
t= .031 (0.8)
50
Level
Meter
50
13
24
Filter
Oscillator
50
Common Mode
50
Level
Meter
50
13
24
Filter
Oscillator
5050
Normal Mode
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
10
00.1 0.2 0.5 12 510 20 50
2 Amp
4 Amp
6 Amp
90
Insertion Loss (dB)
80
Frequency (MHz)
70
60
50
40
30
20
00.1 0.2 0.5 12 510 20 50
6 Amp
90
100
4 Amp
2 Amp
Dimensions in inches (mm)
Switched and Fused Filtered
Power Entry Modules
51
SPECTRUM CONTROL INC. 8031 Avonia Rd. Fairview, PA 16415 Phone: 814-474-2207 Fax: 814-474-2208 Web site: www.spectr umcontrol.com
SPECTRUM CONTROL GmbH Hansastrasse 6 91126 Schwabach, Germany Phone: (49)-9122-795-0 Fax: (49)-9122-795-58
68-BSF Series