Power Entry Modules Bolt-in Rear Terminals 60-BPR & BPS Series Features Power Entry Modules Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Solder lug and Fast-on tab terminals available Operating temperature: -25C to +85C (including temperature rise, see graph on page 25) UL approved low leakage version also available Circuit Diagram 3 1 Applications CY L1 CX E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY 2 4 Specifications Model* Rated Voltage (@ 50/60Hz) Rated Current 60-XXX-010-3-2 60-XXX-010-3-4 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 20% 0.50mA 3300pF 20% 60-XXX-010-5-4 0.35mA 250VAC 2200pF 20% 0.50mA 3300pF 20% 60-XXX-020-5-4 0.35mA 250VAC 2200pF 20% 0.50mA 3300pF 20% 60-XXX-030-5-4 0.35mA 250VAC 2200pF 20% 0.50mA 3300pF 20% 0.35mA 2200pF 20% 0.50mA 3300pF 20% 0.35mA 2200pF 20% 60-XXX-060-5-4 0.53mH 45C .022uF 20% 0.26mH 45C .01uF 20% 0.15mH 45C .022uF 20% .022uF 20% .047uF 20% 250VAC 10A 250VAC 15A Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 24 30C .022uF 20% .047uF 20% 6A 60-XXX-060-5-2 60-BPR-150-3-11 1.2mH .022uF 20% .047uF 20% 60-XXX-060-3-2 60-XXX-100-5-2 30C .022uF 20% .047uF 20% 3A 60-XXX-030-5-2 60-XXX-100-3-2 2.4mH .022uF 20% .047uF 20% 60-XXX-030-3-2 60-XXX-060-3-4 30C .022uF 20% .047uF 20% 2A 60-XXX-020-5-2 60-XXX-030-3-4 6.0mH .022uF 20% .047uF 20% 60-XXX-020-3-2 60-XXX-020-3-4 Temperature Rise (Max.) .047uF 20% 1A 60-XXX-010-5-2 Inductance (L1) CX * Substitute BPR or BPS for XXX BPS - Solder lug terminals BPR - Fast-on tab terminals SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Power Entry Modules Bolt-in Rear Terminals 60-BPR & BPS Series Temperature Characteristics 0.807 (20.5) Power Entry Modules 120 Current (%) 100 .944 (24) 80 .846 (21.5) 60 1.476 (37.5) (2x) .142 (3.6) 40 1.967 (50) 0 20 30 40 50 60 70 Ambient Temperature (C) 80 .157 (4) 1.10 (28) 1.181 (30) 1.573 (40) 20 * General tolerance .012 (0.3) 90 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50 1 3 Filter 2 4 50 Level Meter 50 Oscillator 50 50 80 70 70 60-BPX-010-5-X 60-BPX-010-5-X Insertion Loss (dB) 60 50 40 60-BPX-020-5-X 30 60-BPX-030-5-X 20 60 50 40 60-BPX-020-5-X 30 60-BPX-030-5-X 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 5 10 20 50 60-BPX-060;-100 60-BPX-060;-100 80 80 70 70 Insertion Loss (dB) 60 60-BPX-060-5-X 50 40 30 60-BPX-100-5-X 20 60-BPX-060-X-4 60 50 60-BPX-060-X-2 40 60-BPX-100-X-2 30 20 10 10 0 0.1 2 Frequency (MHz) Frequency (MHz) Insertion Loss (dB) 50 Level Meter 50 60-BPX-010;-020;-030 60-BPX-010;-020;-030 80 Insertion Loss (dB) 2.263 (57.5) .252 (6.4) 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 25 Power Entry Modules Bolt-in Right Angle Terminals 60-BPF Series Features Power Entry Modules Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards PCB mounting types available (see page 54) Length under tab is shortened for small spaces Operating temperature: -25C to +85C (including temperature rise, see graph on page 27) UL approved low leakage version also available 3 1 CY L1 CX Applications Circuit Diagram E E CY Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units 2 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BPF-010-3-2 60-BPF-010-3-4 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 20% 0.50mA 3300pF 20% 60-BPF-010-5-4 0.35mA 250VAC 2200pF 20% 0.50mA 3300pF 20% 60-BPF-020-5-4 30C 2.4mH 30C 1.2mH 30C 0.53mH 45C .022uF 20% .022uF 20% .047uF 20% 60-BPF-030-3-2 0.35mA 250VAC 2200pF 20% .022uF 20% .047uF 20% 3A 60-BPF-030-5-2 0.50mA 3300pF 20% 60-BPF-030-5-4 .022uF 20% .047uF 20% 60-BPF-060-3-2 60-BPF-060-3-4 6.0mH .022uF 20% .047uF 20% 2A 60-BPF-020-5-2 60-BPF-030-3-4 Temperature Rise (Max.) .047uF 20% 60-BPF-020-3-2 60-BPF-020-3-4 Inductance (L1) .022uF 20% .047uF 20% 1A 60-BPF-010-5-2 CX 0.35mA 250VAC 2200pF 20% .047uF 20% 6A 60-BPF-060-5-2 60-BPF-060-5-4 .022uF 20% 0.50mA 3300pF 20% .022uF 20% .047uF 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 26 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Power Entry Modules Bolt-in Right Angle Terminals 60-BPF Series ( ) 1.463 (37.2) 1.967 (50) Temperature Characteristics 120 1.317 (33.5) 1.573 (40) .885 (22.5) .991 (25.2) .590 (15) 2- .142 (3.6) Current (%) 100 .047 (1.2) .232 (5.9) 80 .024 (.6) 5 . R4 .865 (22) 60 2- .142 (3.6) 1.573 (40) 40 .142 .059 (3.6) (1.5) .031 (.8) 1.070 (27.2) 1.180 (30) * General tolerance .012 (.3) .779 1.180 (19.8) (30) .708 (18) Panel cutout dimensions mounts from backside 20 0 20 30 40 50 60 70 Ambient Temperature (C) 80 Power Entry Modules 60-BPF Fast-on Terminals 90 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50 1 3 Filter 2 4 50 Level Meter 50 Oscillator 50 60-BPF-010;-020 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 60-BPF-010-3-X 60 50 60-BPF-020-3-X 40 30 20 10 60 60-BPF-010-X-4 50 40 30 60-BPF-020-X-4 20 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 5 10 20 50 20 50 60-BPF-030;-060 60-BPF-030;-060 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 2 Frequency (MHz) 80 60-BPF-030-3-X 50 40 60-BPF-060-3-X 30 20 60 50 40 60-BPF-030-X-4 30 60-BPF-060-X-4 20 10 10 0 0.1 50 Level Meter 50 60-BPF-010;-020 80 0 0.1 50 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 Frequency (MHz) SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 27 Power Entry Modules High Frequency Attenuation 60-BHS Series Features Power Entry Modules Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 PCB mounting types available (see page 56) PCB mounting minimizes space and provides economical installation Excellent filtering characteristics for high frequencies Earth coil standard Operating temperature: -25C to +85C (including temperature rise, see graph on page 29) Applications Circuit Diagram 3 1 CY L1 CX E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY 2 4 L2 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BHS-010-3-11 60-BHS-010-3-4 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 20% 0.50mA 3300pF 20% 60-BHS-010-5-4 0.35mA 250VAC 2200pF 20% 0.50mA 3300pF 20% 60-BHS-020-5-4 18.3uH 30C 2.4mH 18.3uH 30C 1.2mH 18.3uH 30C .53mH 18.3uH 45C 0.1uF 20% 0.1uF 20% .047uF 20% 60-BHS-030-3-11 0.35mA 250VAC 2200pF 20% 0.1uF 20% .047uF 20% 3A 60-BHS-030-5-11 0.50mA 3300pF 20% 60-BHS-030-5-4 0.1uF 20% .047uF 20% 60-BHS-060-3-11 60-BHS-060-3-4 6mH 0.1uF 20% .047uF 20% 2A 60-BHS-020-5-11 60-BHS-030-3-4 Temperature Rise (Max.) .047uF 20% 60-BHS-020-3-11 60-BHS-020-3-4 Inductance (L1) (L2) 0.1uF 20% .047uF 20% 1A 60-BHS-010-5-11 CX 0.35mA 250VAC 2200pF 20% 6A 60-BHS-060-5-11 60-BHS-060-5-4 0.1uF 20% .047uF 20% 0.50mA 3300pF 20% 0.1uF 20% .047uF 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 28 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Power Entry Modules High Frequency Attenuation 60-BHS Series .098 (2.5) 1.967 (50) 1.573 (40) 120 .885 (22.5) 100 Current (%) 1.534 (39) 1.389 (35.3) Power Entry Modules Temperature Characteristics 1.180 (30) 2- .142 (3.6) 80 1.180 (30) .031 (.8) .5 R4 .865 (22) 60 40 2- .142 (3.6) 1.573 (40) .779 1.180 (19.8) (30) Panel cutout dimensions mounts from backside 20 0 20 30 40 50 60 70 Ambient Temperature (C) 80 Dimensions in inches (mm) 90 Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50 90 1 3 Filter 2 4 50 Level Meter 50 Oscillator 50 60-BHS-XXX-X-11 90 50 50 Level Meter 50 60-BHS-XXX-3-11 80 80 Insertion Loss (dB) Insertion Loss (dB) 60-BHS-010-X-11 70 60-BHS-020-X-11 60 50 40 60-BHS-030-X-11 30 60-BHS-060-X-11 70 60-BHS-010-3-11 60 50 60-BHS-020-3-11 40 60-BHS-030-3-11 30 60-BHS-060-3-11 20 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 90 60-BHS-XXX-X-4 90 5 10 20 50 60-BHS-XXX-3-4 80 60-BHS-010-X-4 70 Insertion Loss (dB) Insertion Loss (dB) 80 60-BHS-020-X-4 60 50 40 60-BHS-030-X-4 30 60-BHS-060-X-4 70 60-BHS-010-3-4 60 50 60-BHS-020-3-4 40 60-BHS-030-3-4 30 60-BHS-060-3-4 20 20 10 10 0 0.1 2 Frequency (MHz) Frequency (MHz) 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 29 Power Entry Modules Bolt-in Rear Terminals For General Purpose Applications 10-BPF Series Features Power Entry Modules Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Operating temperature: -25C to +70C Compact configuration Circuit Diagram CX CY Applications CY L1 1 Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CX CY L1 CX CY 2 CX CX L1 CY CY 3 Specifications Model Rated Rated Voltage Current (@ 50/60Hz) 10-BPF-001-5-A Leakage Current (Max.) 1A 120/250VAC 1.5mH 0.50mA 10-BPF-006-5-A 6A 4700pF 10A 10-BPF-010-5-D Temperature Rise (Max.) C A C 2 B A 0.5mH 1 3300pF & 0.01uF 1.5mH 2 B 3300pF 0.01uF 0.5mH 1 A 3300pF & 0.01uF 3300pF & 0.01uF 1.5mH 3 B 3300pF 3300pF & 0.01uF 10-BPF-006-5-D 0.01uF Figure A 3.0mH 1 3A 10-BPF-003-5-C 10-BPF-010-5-A Inductance Circuit (L1) Diagram 3300pF 10-BPF-003-5-A 10-BPF-006-5-C CX 2200pF 10-BPF-001-5-C 10-BPF-003-5-D Capacitance CY 30C C Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 30 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Power Entry Modules Bolt-in Rear Terminals Figure B M3 (2X) For General Purpose Applications 1.6 (40) M3 (2X) 2.0 (52) 2.0 (52) 1.1 (28.5) +.01 -0.0 1.6 (40) .007 1.4 (37) 2.8 (72) 1.25 (32) Figure A Figure C .80 (20.5) +.01 -0.0 1.4 (3.5) (2X) 2.3 (62) 1.9 1.6 1.2 (50) (40) (30) .62 (16) .82 (21) .25 (6.5) 1.8 (46) .13 (3.5 (2X) 1.1 (28) 1.5 (37.5) 1.6 (40) 2.0 (51) 1.9 (50) 1.1 (27) Power Entry Modules 10-BPF Series .07 (2) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50 1 3 Filter 2 4 50 Level Meter 50 Oscillator 50 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 10-BPF-001-5-A 10-BPF-001-5-C 50 40 10-BPF-003-5-A 30 10-BPF-003-5-C 20 60 10-BPF-001-5-A 50 10-BPF-001-5-C 40 30 10-BPF-003-5-A 20 10-BPF-003-5-C 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 5 10 50 80 10-BPF-006-5-D 70 70 Insertion Loss (dB) 60 10-BPF-006-5-A 10-BPF-006-5-C 40 30 20 10-BPF-006-5-D 60 50 40 10-BPF-010-5-A 10-BPF-010-5-D 30 10-BPF-006-5-A 20 10-BPF-006-5-C 10-BPF-010-5-A 10 10 0 0.1 20 10-BPF-006;-010 10-BPF-006;-010 80 Insertion Loss (dB) 2 Frequency (MHz) Frequency (MHz) 50 50 Level Meter 50 10-BPF-001;-003 10-BPF-001;-003 80 60 50 10-BPF-010-5-D 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 31 Power Entry Modules Bolt-in Rear Terminals For Medical Purpose Applications 10-BPF Series Features Power Entry Modules Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Operating temperature: -25C to +70C Compact configuration Low leakage current Circuit Diagram 3 1 Applications L1 Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CX E E 2 4 Specifications Model Rated Rated Voltage Current (@ 50/60Hz) 10-BPF-001-2-A 10-BPF-003-2-A 120/250VAC 10-BPF-006-2-A 1A Leakage Current (Max.) Capacitance CX 5uA 0.01uF Inductance (L1) Circuit Diagram Figure Temperature Rise (Max.) 1 A 30C 3.0mH 10A 1.5mH 0.5mH Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 32 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Power Entry Modules Bolt-in Rear Terminals For Medical Purpose Applications Power Entry Modules 10-BPF Series M3 (2X) 1.1 (28.5) +.01 -0.0 1.6 (40) .007 .80 (20.5) +.01 -0.0 1.4 (3.5) (2X) 0.807 (20.5) 1.9 1.6 1.2 (50) (40) (30) Dimensions in inches (mm) 1.1 (28) 1.5 (37.5) .63 (16) Common Mode Normal Mode 1 3 Filter 2 4 1 3 Filter 2 4 Oscillator 50 50 Level Meter 50 Oscillator 50 50 50 Level Meter 50 10-BPF-001;-003;-006 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 10-BPF-001;-003;-006 80 60 2.0 (51) .25 (6.5) .82 (21) 10-BPF-001-2-A 50 10-BPF-003-2-A 40 30 20 60 50 40 30 10-BPF-006-2-A 10-BPF-001-2-A 20 10-BPF-006-2-A 10 0 0.1 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 10-BPF-003-2-A 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 33 Power Entry Modules Snap-in with Wire Leads 60-SPL Series Features Power Entry Modules Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Snap-in style saves labor and hardware inventory Wire output minimizes space and provides economical installation Operating temperature: -25C to +85C (including temperature rise, see graph on page 35) Applications Circuit Diagram 3 1 CY L1 CX E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY 2 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-SPL-010-3-2 60-SPL-010-3-3 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 20% 0.50mA 3300pF 20% 60-SPL-010-5-3 0.35mA 250VAC 2200pF 20% 0.50mA 3300pF 20% 60-SPL-020-5-3 30C 2.4mH 30C 1.2mH 30C 0.53mH 45C 22nF 20% 22nF 20% 33nF 20% 60-SPL-030-3-2 0.35mA 250VAC 2200pF 20% .022uF 20% 3300pF 20% 3A 60-SPL-030-5-2 0.50mA 60-SPL-030-5-3 2200pF 20% .033uF 20% 3300pF 20% 60-SPL-060-3-2 60-SPL-060-3-3 6.0mH 22nF 20% 33nF 20% 2A 60-SPL-020-5-2 60-SPL-030-3-3 Temperature Rise (Max.) 33nF 20% 60-SPL-020-3-2 60-SPL-020-3-3 Inductance (L1) 22nF 20% 33nF 20% 1A 60-SPL-010-5-2 CX 0.35mA 250VAC 2200pF 20% 6A 60-SPL-060-5-2 60-SPL-060-5-3 22nF 20% 33nF 20% 0.50mA 3300pF 20% 22nF 20% 33nF 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 34 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Power Entry Modules Snap-in with Wire Leads 60-SPL Series .963 (24.5) * General tolerance .012 (.3) 120 .853 (21.7) .838 (21.3) Panel cutout dimensions 100 Current (%) R2 * Metal case Tin Plated 80 W T W .039 (1.0) 1.270 (32.3) .047 (1.2) 1.274 (32.4) .059 (1.5) 1.285 (32.5) T :Panel Thickness 1.612 (41) 4.719 (120)* .252 (6.4) 1.172 (29.8) .236 (6) 60 Blue UL 1015 AWG #18 1.397 (35.5) 40 Green/Yellow Brown 20 PVC Insulated wire * Custom lengths available upon request. 0 20 30 40 50 60 70 Ambient Temperature (C) 80 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 Oscillator 50 1 3 Filter 2 4 50 Level Meter 50 Oscillator 50 60-SPL-010-X-4 60-SPL-020-5-X 70 60-SPL-010-X-2 Insertion Loss (dB) 60-SPL-010-5-X 50 60-SPL-010-3-X 40 30 20 60 50 60-SPL-020-X-4 40 30 60-SPL-020-X-2 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 5 10 20 50 60-SPL-030;-060 60-SPL-030;-060 80 80 60-SPL-030-X-4 60-SPL-030-5-X 70 70 60-SPL-030-3-X Insertion Loss (dB) 60 50 40 60-SPL-060-5-X 30 60-SPL-060-3-X 60 60-SPL-030-X-2 50 40 60-SPL-060-X-4 30 20 20 10 10 0 0.1 2 Frequency (MHz) Frequency (MHz) Insertion Loss (dB) 50 Level Meter 50 80 60-SPL-020-3-X Insertion Loss (dB) 50 60-SPL-010;-020 60-SPL-010;-020 80 70 UL1617 AWG #22 90 Common Mode 60 Power Entry Modules Temperature Characteristics 60-SPL-060-X-2 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 35 Power Entry Modules Bolt-in with Wire Leads 60-BPL Series Features Ideally suited for products that must conform to FCC part 15 regulations Metal case filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Wire output for minimizing space use and economical installation Operating temperature: -25C to +85C (including temperature rise, see graph on page 37) Power Entry Modules Tested and found to be IAW VDE 0565 Part 3. Circuit Diagram 3 1 Applications CY L1 CX E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY 2 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BPL-010-3-2 60-BPL-010-3-3 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 20% 0.50mA 3300pF 20% 60-BPL-010-5-3 0.35mA 250VAC 2200pF 20% 0.50mA 3300pF 20% 60-BPL-020-5-3 30C 2.4mH 30C 1.2mH 30C 0.53mH 45C 22nF 20% 22nF 20% 33nF 20% 60-BPL-030-3-2 0.35mA 250VAC 2200pF 20% .022uF 20% 3300pF 20% 3A 60-BPL-030-5-2 0.50mA 60-BPL-030-5-3 2200pF 20% .033uF 20% 3300pF 20% 60-BPL-060-3-2 60-BPL-060-3-3 6.0mH 22nF 20% 33nF 20% 2A 60-BPL-020-5-2 60-BPL-030-3-3 Temperature Rise (Max.) 33nF 20% 60-BPL-020-3-2 60-BPL-020-3-3 Inductance (L1) 22nF 20% 33nF 20% 1A 60-BPL-010-5-2 CX 0.35mA 250VAC 2200pF 20% 33nF 20% 6A 60-BPL-060-5-2 60-BPL-060-5-3 22nF 20% 0.50mA 3300pF 20% 22nF 20% 33nF 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 36 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Power Entry Modules Bolt-in with Wire Leads 60-BPL Series .5 .5 R4 .865 (22) 120 1.180 (30) 1.573 (40) Current (%) 100 1.573 (40) 1.612 (41) .830 (21.1) 1.172 (29.8) 1.967 (50) 20 30 40 50 60 70 Ambient Temperature (C) 80 GREEN/YELLOW BROWN 90 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 1 3 Filter 2 4 Oscillator 50 50 Level Meter 50 Oscillator 50 50 50 Level Meter 50 60-BPL-010;-020 60-BPL-010;-020 80 80 60-BPL-020-5-X 60-BPL-010-X-4 70 70 60-BPL-010-X-2 60 50 60-BPL-010-5-X 40 60-BPL-010-3-X 30 20 Insertion Loss (dB) 60-BPL-020-3-X 60 50 60-BPL-020-X-4 40 30 60-BPL-020-X-2 20 10 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) Frequency (MHz) 60-BPL-030;-060 60-BPL-030;-060 80 80 60-BPL-030-X-4 60-BPL-030-5-X 70 70 60-BPL-030-3-X Insertion Loss (dB) 60 50 40 60-BPL-060-5-X 30 60-BPL-060-3-X 20 60 60-BPL-030-X-2 50 40 60-BPL-060-X-2 30 20 60-BPL-060-X-4 10 10 0 0.1 * General tolerance .012 (0.3) PVC Insulated wire UL1617 AWG #22 * Custom lengths available upon request. Common Mode 0 0.1 .236 (6) UL1015 AWG # 18 BLUE 1.160 (29.5) 1.573 (40) 0 Insertion Loss (dB) 4.719 (120)* .252 (6.4) 60 40 1.239 (31.5) Panel cutout dimensions mounts from front side .944 (24) 2- .142 (3.6) 20 Insertion Loss (dB) 2- .118 (M3) 2- .130 (3.3) Panel cutout dimensions mounts from back side 80 R3 .885 (22.5) .837 (21.3) Power Entry Modules Temperature Characteristics 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 37 Power Entry Modules Bolt-in with Wire Leads 10-BPL Series Features Ideally suited for products that must conform to FCC part 15 regulations Metal case filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Wire output for minimizing space use and economical installation Operating temperature: -25C to +70C Compact configuration Power Entry Modules Circuit Diagram Applications 3 1 CY L1 CX E E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY 2 4 Specifications Model Rated Rated Leakage Voltage Current Current (@ 50/60Hz) (Max.) 10-BPL-006-5-B CX 3300pF 0.01uF 1A 10-BPL-001-5-B 10-BPL-003-5-B Capacitance CY 250VAC 3A Inductance Circuit Diagram (L1) Figure Temperature Rise (Max.) A 30C 3.0mH 0.50mA 6A 1.5mH 1 0.5mH Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 38 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Power Entry Modules Bolt-in with Wire Leads 10-BPL Series Figure A Power Entry Modules M3 (2X) 1.1 (28.5) +.01 -0.0 1.6 (40) .007 .80 (20.5) +.01 -0.0 1.4 (3.5) (2X) 1.9 1.6 1.2 (50) (40) (30) 1.1 (28) 1.5 (37.5) .63 (16) 2.0 (51) .25 (6.5) .82 (21) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 1 3 Filter 2 4 Oscillator 50 50 Level Meter 50 Oscillator 50 80 10-BPL-001-5-B 70 70 10-BPL-003-5-B 10-BPL-001-5-B Insertion Loss (dB) Insertion Loss (dB) 50 Level Meter 50 10-BPL-001;-003;-006 10-BPL-001;-003;-006 80 60 50 50 40 30 10-BPL-006-5-B 20 60 50 40 10-BPL-003-5-B 30 20 10-BPL-006-5-B 10 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 39 Power Entry Modules Snap-in Mount 60-SPR & SPS Series Features Power Entry Modules Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Snap-in style saves labor and hardware inventory Solder lug and fast-on tab terminations available Operating temperature: -25C to +85C (including temperature rise, see graph on page 41) UL approved low leakage version also available 3 1 CY L1 CX Applications Circuit Diagram E E CY Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units 2 4 Specifications Model* Rated Voltage (@ 50/60Hz) Rated Current 60-XXX-010-3-2 60-XXX-010-3-4 250VAC Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 20% 0.50mA 3300pF 20% 60-XXX-010-5-4 0.35mA 250VAC 2200pF 20% 30C 2.4mH 30C 1.2mH 30C 0.53mH 45C .022uF 20% 0.26mH 45C .01uF 20% 0.15mH 45C .022uF 20% .022uF 20% .047uF 20% 2A 60-XXX-020-5-2 0.50mA 3300pF 20% 60-XXX-020-5-4 .022uF 20% .047uF 20% 60-XXX-030-3-2 60-XXX-030-3-4 6.0mH .022uF 20% .047uF 20% 60-XXX-020-3-2 60-XXX-020-3-4 Temperature Rise (Max.) .047uF 20% 1A 60-XXX-010-5-2 Inductance (L1) CX 0.35mA 250VAC .022uF 20% 2200pF 20% .047uF 20% 3A 60-XXX-030-5-2 0.50mA .022uF 20% 3300pF 20% 60-XXX-030-5-4 .047uF 20% 60-XXX-060-3-2 60-XXX-060-3-4 0.35mA 250VAC 2200pF 20% .047uF 20% 6A 60-XXX-060-5-2 0.50mA 3300pF 20% 0.35mA 2200pF 20% 0.50mA 3300pF 20% 0.35mA 2200pF 20% 60-XXX-060-5-4 60-XXX-100-3-2 250VAC 10A 250VAC 15A Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 40 .022uF 20% .047uF 20% 60-XXX-100-5-2 60-SPR-150-3-11 .022uF 20% * Substitute SPR or SPS for XXX 60-SPR - Fast-on terminals 60-SPS - Solder lug terminals SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Power Entry Modules Snap-in Mount 60-SPR & SPS Series .837 (21.3) .963 (24.5) 120 .853 (21.7) Panel cutout dimensions Current (%) 100 80 T: Panel Thickness T W .039 (1.0) 1.270 (32.3) .047 (1.2) 1.274 (32.4) .059 (1.5) 1.285 (32.5) 1.418 (35.9) .157 (4) 1.395 (35.5) * Standard terminal Fast-on tab #250 available as SPR series 2.096 (53.3) 20 30 40 50 60 70 Ambient Temperature (C) 80 90 Solder lugs shown. Also available in fast-ons. Common Mode Oscillator 50 1 3 Filter 2 4 50 Level Meter 50 Oscillator 50 60-SPX-010;-020;-030 50 50 Level Meter 50 60-SPX-010;-020;-030 80 80 70 70 60-SPX-010-5-X 60-SPX-010-X-4 Insertion Loss (dB) 60 50 40 60-SPX-020-5-X 30 60-SPX-030-5-X 20 10 60 50 60-SPX-020-X-4 40 60-SPX-030-X-4 30 20 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) Frequency (MHz) 60-SPX-060;-100 60-SPX-060;-100 80 80 70 70 Insertion Loss (dB) 60 60-SPX-60-5-X 50 40 30 60-SPX-100-5-X 20 10 0 0.1 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 0 0.1 1.172 (29.8) * General tolerance .012 (0.3) 0 Insertion Loss (dB) Solder Lug 2 X 3 hole 40 20 Insertion Loss (dB) 1.805 (45.9) .252 (6.4) 60 W Panel cutout dimensions for 1.0t chassis 2.033 (51.7) Power Entry Modules R2 Temperature Characteristics 60-SPX-060-X-4 60 50 60-SPX-060-X-2 40 60-SPX-100-X-2 30 20 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 41 Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BFF/64-65-BFS Series Features Fused Filtered Power Entry Modules Tested and found to be IAW VDE 0565 Part 3. North American and Metric fuse holders available Fuse holder provides effective EMI suppression of common and differential mode Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Fast-on terminals or solder lug terminals Metal case provides effective EMI shielding Operating temperature: -25C to +85C (including temperature rise, see graph on page 43) L L L1 E R CY E CX CY Applications Circuit Diagram N N Computers and peripheral equipment Electronic equipment Digital equipment Measuring and testing instruments Telecommunications equipment Specifications Model* 64-XXX-020-3-11 64-XXX-020-5-11 64-XXX-020-3-12 64-XXX-020-5-12 64-XXX-040-3-11 64-XXX-040-5-11 64-XXX-040-3-12 64-XXX-040-5-12 64-XXX-060-3-11 64-XXX-060-5-11 64-XXX-060-3-12 64-XXX-060-5-12 65-XXX-020-3-11 65-XXX-020-5-11 65-XXX-020-3-12 65-XXX-020-5-12 65-XXX-040-3-11 65-XXX-040-5-11 65-XXX-040-3-12 65-XXX-040-5-12 65-XXX-060-3-11 65-XXX-060-5-11 65-XXX-060-3-12 65-XXX-060-5-12 Rated Voltage (@ 50/60Hz) 250VAC 250VAC 250VAC 125VAC 125VAC 125VAC Rated Current 2A 4A 6A 2A 4A 6A Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 M min. at 500VDC F(S) = Fast-on or (Solder lug terminals) 42 Leakage Current (Max.) 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA Capacitance CY 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF CX 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% Voltage Drop: 1V max. at rated current Weight: 78g Inlet: Compatible with IEC-320 Inductance (L1) Temperature Rise (Max.) 6.5mH 40C 4.2mH 45C 1.6mH 45C 6.5mH 40C 4.2mH 45C 1.6mH 45C 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF * Substitute BFF or BFS for XXX BFF - Fast-on terminals BFS - Solder lug terminals SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BFF/64-65-BFS Series Dimensions Temperature Characteristics 1.738 (44.2) 100 Current (%) 2.32 (59) .098 (2.5) 1.101 (28) Fuse cover 1.376 (35) 80 1.298 (33) 1.29 (32.8) 2 - .13 +.008 -.004 (2 - 3.3+0.2 -0.1) Hole 60 1.416.008 (360.2) 0.252 (6.4) 1.14 (29) 1.616 (41.1) * Alternate Terminal for 64/65-BFS-Solder Lug Terminal 40 Fast-on tab#250 t= .031 (0.8) 20 0.158 (4.0) 0 20 30 40 50 60 70 Ambient Temperature (C) 80 Fused Filtered Power Entry Modules 64/65-BFF Series 120 * General Tolerance: .020 (0.5) * Metal Case 90 2.249 (L:57.2) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50 1 3 Filter 2 4 50 Level Meter 50 Oscillator 50 0.50 mA Leakage Versions 50 50 Level Meter 50 0.50 mA Leakage Versions 90 90 80 80 2 Amp 70 2 Amp Insertion Loss (dB) Insertion Loss (dB) 70 60 50 40 6 Amp 30 20 60 50 6 Amp 40 4 Amp 30 20 4 Amp 10 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 0 0.1 50 0.35 mA Leakage Versions 90 90 80 80 2 Amp Insertion Loss (dB) Insertion Loss (dB) 0.5 1 2 5 Frequency (MHz) 10 20 50 10 20 50 0.35 mA Leakage Versions 70 70 60 50 40 6 Amp 30 2 Amp 60 50 40 6 Amp 30 4 Amp 20 20 4 Amp 10 10 0 0.1 0.2 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 43 Fused Filtered Power Entry Modules For Medical or General Purpose Applications Medical equipment Electronic equipment Digital equipment Industrial equipment Telecommunications equipment Measuring and testing instruments Personal computers and peripherals Circuit Diagrams 66/67-BFF(S)-XXX-0-X and 66/67-BFF(S)-XXX-4-X Filters 66/67-BFF(S)-XXX-1-X Filter L L L L L1 R L1 CX E E R CY CX E E CY N N N N Specifications Model* 66-XXX-020-1-11 66-XXX-020-1-12 66-XXX-020-0-11 66-XXX-020-4-11 66-XXX-020-0-12 66-XXX-020-4-12 66-XXX-040-1-11 66-XXX-040-1-12 66-XXX-040-0-11 66-XXX-040-4-11 66-XXX-040-0-12 66-XXX-040-4-12 66-XXX-060-1-11 66-XXX-060-1-12 66-XXX-060-0-11 66-XXX-060-4-11 66-XXX-060-0-12 66-XXX-060-4-12 67-XXX-020-1-11 67-XXX-020-1-12 67-XXX-020-0-11 67-XXX-020-4-11 67-XXX-020-0-12 67-XXX-020-4-12 67-XXX-040-1-11 67-XXX-040-1-12 67-XXX-040-0-11 67-XXX-040-4-11 67-XXX-040-0-12 67-XXX-040-4-12 67-XXX-060-1-11 67-XXX-060-1-12 67-XXX-060-0-11 67-XXX-060-4-11 67-XXX-060-0-12 67-XXX-060-4-12 Rated Voltage (@ 50/60Hz) Rated Current 0.01mA 250VAC 2A 0.075mA 0.1mA 0.075mA 0.1mA 0.01mA 250VAC 4A 0.075mA 0.1mA 0.075mA 0.1mA 0.01mA 250VAC 6A 0.075mA 0.1mA 0.075mA 0.1mA 0.005mA 125VAC 2A 0.035mA 0.05mA 0.035mA 0.05mA 0.005mA 125VAC 4A 0.035mA 0.05mA 0.035mA 0.05mA 0.005mA 125VAC 6A Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 M min. at 500VDC F(S) = Fast-on or (Solder lug terminals) 44 Leakage Current (Max.) 0.035mA 0.05mA 0.035mA 0.05mA Capacitance CY none 330pF 470pF 330pF 470pF 20% 20% 20% 20% none 330pF 470pF 330pF 470pF 20% 20% 20% 20% none 330pF 470pF 330pF 470pF 20% 20% 20% 20% none 330pF 470pF 330pF 470pF 20% 20% 20% 20% none 330pF 470pF 330pF 470pF 20% 20% 20% 20% none 330pF 470pF 330pF 470pF 20% 20% 20% 20% Voltage Drop: 1V max. at rated current Weight: 78g Inlet: Compatible with IEC-320 CX 0.1uF 0.22uF 0.1uF Inductance (L1) Temperature Rise (Max.) 6.5mH 40C 4.2mH 45C 1.6mH 45C 6.5mH 40C 4.2mH 45C 1.6mH 45C 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF * Substitute BFF or BFS for XXX BFF - Fast-on terminals BFS - Solder lug terminals SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 LOAD Applications LINE Tested and found to be IAW VDE 0565 Part 3. Metric and North American fuse holders available Fuse holder provides effective EMI suppression of common and differential mode Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Fast-on terminations or solder lug terminations Metal case provides effective EMI shielding Provides susceptibility protection without the leakage current associated with line-to-ground capacitance Reduces the line to ground capacitance in order to meet patient care requirements Operating temperature: -25C to +85C (including temperature rise, see graph on page 45) LOAD Fused Filtered Power Entry Modules LINE 66-67-BFF/66-67-BFS Series Features Fused Filtered Power Entry Modules For Medical or General Purpose Applications 66-67-BFF/66-67-BFS Series Dimensions Temperature Characteristics 1.738 (44.2) 2.32 (59) .098 (2.5) 1.101 (28) 100 Current (%) Fuse cover 1.376 (35) 80 1.298 (33) 60 1.416.008 (360.2) 40 1.29 (32.8) 2 - .13 +.008 -.004 (2 - 3.3+0.2 -0.1) Hole 0.252 (6.4) 1.14 (29) 1.616 (41.1) * Alternate Terminal for 66/67-BFS-Solder Lug Terminal Fast-on tab#250 t= .031 (0.8) 20 0.158 (4.0) 0 20 30 40 50 60 70 Ambient Temperature (C) 80 2.249 (L:57.2) Oscillator 50 1 3 Filter 2 4 50 Level Meter 50 Oscillator 50 90 90 80 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 50 60 2 Amp 40 30 60 2 Amp 50 30 0 0.1 0.2 0.5 10 1 2 5 Frequency (MHz) 10 20 0 0.1 50 80 80 70 70 Insertion Loss (dB) 90 60 2 Amp 50 0.2 0.5 1 2 5 Frequency (MHz) 40 30 10 0.2 0.5 20 50 60 50 2 Amp 40 30 4 Amp 20 20 6 Amp 6 Amp 4 Amp 10 0.075 and 0.1 mA Leakage Current 0.075 and 0.1 mA Leakage Current 90 0 0.1 6 Amp 6 Amp 4 Amp 4 Amp 40 20 20 10 50 Level Meter 50 0.01 mA Leakage Current 0.01 mA Leakage Current Insertion Loss (dB) Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 50 * General Tolerance: .020 (0.5) * Metal Case 90 Common Mode Fused Filtered Power Entry Modules 66-67-BFF/66-67-BFS Series 120 10 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 45 Switched and Fused Filtered Power Entry Modules Switched and Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BSF/64-65-SSF Series Features Tested and found to be IAW VDE 0565 Part 3. North American and Metric fuse holders available Fuse holder and double pole power ON/OFF switch provided in a convenient/compact package Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Metal case provides effective EMI shielding Easy access fuse drawer with space for spare fuse Flange-mounted or snap-in styles available for quick mounting Operating temperature: -25C to +85C (including temperature rise, see graph on page 47) Applications Computers and peripheral equipment Electronic equipment Digital equipment Measuring and testing instruments Telecommunications equipment Circuit Diagram L L CY CX E CX E R CY N N Specifications Model* Rated Voltage (@ 50/60Hz) Rated Current 64-XXX-020-3-12 64-XXX-020-3-04 64-XXX-020-3-14 64-XXX-020-3-06 250VAC 2A 64-XXX-020-5-12 64-XXX-020-5-04 64-XXX-020-5-14 64-XXX-020-5-06 64-XXX-040-3-12 64-XXX-040-3-04 64-XXX-040-3-14 64-XXX-040-3-06 250VAC 4A 64-XXX-040-5-12 64-XXX-040-5-04 64-XXX-040-5-14 64-XXX-040-5-06 64-XXX-060-3-12 64-XXX-060-3-04 64-XXX-060-3-14 64-XXX-060-3-06 250VAC 6A 64-XXX-060-5-12 64-XXX-060-5-04 64-XXX-060-5-14 64-XXX-060-5-06 65-XXX-020-3-12 65-XXX-020-3-04 65-XXX-020-3-14 65-XXX-020-3-06 125VAC 2A 65-XXX-020-5-12 65-XXX-020-5-04 65-XXX-020-5-14 65-XXX-020-5-06 65-XXX-040-3-12 65-XXX-040-3-04 65-XXX-040-3-14 65-XXX-040-3-06 125VAC 4A 65-XXX-040-5-12 65-XXX-040-5-04 65-XXX-040-5-14 65-XXX-040-5-06 65-XXX-060-3-12 65-XXX-060-3-04 65-XXX-060-3-14 65-XXX-060-3-06 125VAC 6A 65-XXX-060-5-12 65-XXX-060-5-04 65-XXX-060-5-14 65-XXX-060-5-06 Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 M min. at 500VDC B(S) = Bolt-in terminals or (Snap-in terminals) 46 Leakage Current (Max.) CY 0.35mA 2200pF Capacitance CX1 0.22uF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 2200pF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 0.47uF 2200pF 0.22uF 0.50mA 0.47uF 0.22uF 0.35mA 2200pF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 2200pF 0.47uF 0.22uF 0.50mA 3300pF 0.47uF 0.22uF 0.35mA 0.47uF 2200pF 0.22uF 0.50mA 0.47uF Voltage Drop: 1V max. at rated current Weight: 130g Inlet: Compatible with IEC-320 CX2 Inductance (L1) NONE 0.22uF NONE 10.5mH 0.47uF NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 4.2mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 1.6mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 10.5mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 4.2mH NONE 0.22uF NONE 0.47uF NONE 0.22uF NONE 0.47uF 1.6mH NONE 0.22uF NONE 0.47uF * Substitute BSF or SSF for XXX BSF - Bolt-in switched and fused SSF - Snap-in switched and fused Temperature Rise (Max.) 45C 45C 45C 45C 45C 45C SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Temperature Temperature Characteristics Characteristics 120 100 Current (%) Switched and Fused Filtered Power Entry Modules 80 60 40 20 0 Dimensions 30 40 50 60 70 Ambient Temperature (C) 80 90 64/65-SSF Series 64/65-BSF Series 1.947 (49.5) 1.101 (28) 20 1.313 (33.4) 1.101 (28) .248 (6.3) .248 (6.3) 1.133 (28.8) 1.514 (38.8) 1.526 (38.8) Fast-on tab #250 t= .031 (0.8) 2.556 (65) 2.556 (65) 2.340 (59.5) 2.348 (59.7) 2.348 (59.7) 2.340 (59.5) O.142 (3.6) R .079 (2.0) 2 - .142 (3.6) Hole R .059 (1.5) A t= .031 (0.8) Panel cutout dimension mount from back side 1.573 1.16.334 0 (40.0.2) (29.5 0.5) 0 Thickness of Panel .031 (0.8t) .039 (1.0t) .047 (1.2t) .059 (1.5t) .071 (1.8t) .079 (2.0t) 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (400.2) 2.273 (57.8) Dimensions in inches (mm) Panel cutout dimension mount from back side 1.16 +.02 -0 (29.5 +0.5 -0 ) A 2.430 (61.80.1) 2.446 (62.20.1) 2.462 (62.60.1) 2.470 (62.80.1) 2.473 (62.90.1) 2.477 (63.00.1) Switched and Fused Filtered Power Entry Modules For General Purpose Applications * General Tolerance .039 (1.0) * Metal Case 2.399 (61) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50 50 1 3 Filter 2 4 50 Level Meter Oscillator 50 0.35 mA Leakage Versions 100 80 90 70 80 2 Amp Insertion Loss (dB) Insertion Loss (dB) 50 Level Meter 50 64/65-B(S)SF-*-*-02(04,06) 90 60 50 40 4 Amp 30 6 Amp 20 70 60 50 2 Amp 40 4 Amp 30 10 6 Amp 20 0 0.1 0.2 1 0.5 2 5 Frequency (MHz) 10 20 0 0.1 50 0.50 mA Leakage Versions 0.5 1 2 5 Frequency (MHz) 10 20 50 20 50 100 80 90 70 80 Insertion Loss (dB) 2 Amp 60 50 40 4 Amp 30 6 Amp 20 70 60 4 Amp 6 Amp 50 2 Amp 40 30 10 0 0.1 0.2 64/65-B(S)SF-*-*-11(12,14) 90 Insertion Loss (dB) 50 20 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 47 Switched and Fused Filtered Power Entry Modules 66-67-BSF/66-67-SSF Series Features Tested and found to be IAW VDE 0565 Part 3 Metric and North American fuse holders available Fuse holder and a double pole power ON/OFF switch provides a convenient/compact package Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Provides susceptibility protection without the leakage current associated with line-to-ground capacitors Designed to meet requirements for non-patient and patient care equipment Metal case provides effective EMI shielding Easy access fuse drawer - space for spare fuse Flange-mounted or snap-in styles available for quick mounting Operating temperature: -25C to +85C (including temperature rise, see graph on page 49) Applications Medical equipment Industrial equipment Telecommunications equipment Measuring and testing instruments Digital equipment (including switching power supplies) General purpose filter for susceptibility or high frequency "clean up" applications Circuit Diagram L L L1 R CX1 CX2 CY1 E E LOAD Note: CY1 and CY2 capacitors omitted on 66/67 B(S)F-XXX-1-X Filters LINE Switched and Fused Filtered Power Entry Modules For Medical or General Purpose Applications CY2 N N Specifications Model* 66-XXX-020-0-12 66-XXX-020-0-04 66-XXX-020-0-14 66-XXX-020-0-06 66-XXX-020-1-12 66-XXX-020-1-04 66-XXX-020-1-14 66-XXX-020-1-06 66-XXX-020-4-12 66-XXX-020-4-04 66-XXX-020-4-14 66-XXX-020-4-06 66-XXX-040-0-12 66-XXX-040-0-04 66-XXX-040-0-14 66-XXX-040-0-06 66-XXX-040-1-12 66-XXX-040-1-04 66-XXX-040-1-14 66-XXX-040-1-06 66-XXX-040-4-12 66-XXX-040-4-04 66-XXX-040-4-14 66-XXX-040-4-06 66-XXX-060-0-12 66-XXX-060-0-04 66-XXX-060-0-14 66-XXX-060-0-06 66-XXX-060-1-12 66-XXX-060-1-04 66-XXX-060-1-14 66-XXX-060-1-06 66-XXX-060-4-12 66-XXX-060-4-04 66-XXX-060-4-14 66-XXX-060-4-06 Rated Rated Leakage Voltage Current Current Capacitance 50/60Hz (Max.) CY CX1 CX2 0.22uF .075mA 330pF 0.47uF 0.22uF 2A .01mA NONE 0.47uF 0.22uF 0.1mA 470pF 0.47uF 0.22uF .075mA 330pF 0.47uF 250 VAC 0.22uF 4A .01mA NONE 0.47uF 0.22uF .01mA 470pF 0.47uF 0.22uF .075mA 330pF 0.47uF 0.22uF 6A .01mA NONE 0.47uF 0.22uF 0.1mA 470pF 0.47uF Rise (Max.) NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH 40C NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF 45C NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF Note: Test Voltage: 1500VAC one minute, line to ground Insulation Resistance: 300 M min. at 500VDC Voltage Drop: 1V max. at rated current 48 Temp. Induct. (L1) Model* 67-XXX-020-0-12 67-XXX-020-0-04 67-XXX-020-0-14 67-XXX-020-0-06 67-XXX-020-1-12 67-XXX-020-1-04 67-XXX-020-1-14 67-XXX-020-1-06 67-XXX-020-4-12 67-XXX-020-4-04 67-XXX-020-4-14 67-XXX-020-4-06 67-XXX-040-0-12 67-XXX-040-0-04 67-XXX-040-0-14 67-XXX-040-0-06 67-XXX-040-1-12 67-XXX-040-1-04 67-XXX-040-1-14 67-XXX-040-1-06 67-XXX-040-4-12 67-XXX-040-4-04 67-XXX-040-4-14 67-XXX-040-4-06 67-XXX-060-0-12 67-XXX-060-0-04 67-XXX-060-0-14 67-XXX-060-0-06 67-XXX-060-1-12 67-XXX-060-1-04 67-XXX-060-1-14 67-XXX-060-1-06 67-XXX-060-4-12 67-XXX-060-4-04 67-XXX-060-4-14 67-XXX-060-4-06 Rated Rated Leakage Voltage Current Current Capacitance 50/60Hz (Max.) CY CX1 CX2 0.22uF 0.04mA 330pF 0.47uF 0.22uF 2A .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF 0.22uF 0.04mA 330pF 0.47uF 125 VAC 0.22uF 4A .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF 0.22uF 0.04mA 330pF 0.47uF 0.22uF 6A Weight: 130g Inlet: Compatible with IEC-320 B(S) = Bolt-in terminals or (Snap-in terminals) .005mA NONE 0.47uF 0.22uF 0.05mA 470pF 0.47uF Temp. Induct. (L1) Rise (Max.) NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH 40C NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF 45C NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF * Substitute BSF or SSF for XXX BSF - Bolt-In Switched and Fused SSF - Snap-In Switched and Fused SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Temperature Characteristics 120 100 Current (%) Switched and Fused Filtered Power Entry Modules For Medical or General Purpose Applications 80 60 40 20 20 30 40 50 60 70 Ambient Temperature (C) 80 90 Dimensions 66/67-BSF Series 1.947 (49.5) 1.101 (28) 66/67-SSF Series .248 (6.3) 1.313 (33.4) 1.101 (28) 1.526 (38.8) .248 (6.3) 1.133 (28.8) 1.514 (38.8) Fast-on tab #250 2.556 (65) t= .031 (0.8) 2.556 (65) 2.348 (59.7) 2.340 (59.5) O.142 (3.6) 2 - .142 (3.6) Hole R .079 (2.0) 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (400.2) 2.340 (59.5) 2.348 (59.7) R .059 (1.5) A Dimensions in inches (mm) 2.399 (61) Common Mode 1 3 Filter 2 4 50 Level Meter 50 Oscillator 50 80 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 90 60 2 Amp 40 30 20 2 Amp 50 40 30 4 Amp 6 Amp 10 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 0 0.1 50 90 80 80 70 70 Insertion Loss (dB) 90 60 2 Amp 50 40 30 20 1 2 5 Frequency (MHz) 10 20 50 2 Amp 60 50 40 4 Amp 30 6 Amp 10 10 0 0.1 0.5 20 6 Amp 4 Amp 0.2 0.075 and 0.1 mA Leakage Current 0.075 and 0.1 mA Leakage Current Insertion Loss (dB) 50 Level Meter 50 60 20 6 Amp 4 Amp 50 0.01 mA Leakage Current 0.01 mA Leakage Current 90 50 * General Tolerance .039 (1.0) * Metal Case Panel cutout dimension mount from back side 1.16 +.02 -0 (29.5 +0.5 -0 ) A 2.430 (61.80.1) 2.446 (62.20.1) 2.462 (62.60.1) 2.470 (62.80.1) 2.473 (62.90.1) 2.477 (63.00.1) Normal Mode 1 3 Filter 2 4 Oscillator 50 Thickness of Panel .031 (0.8t) .039 (1.0t) .047 (1.2t) .059 (1.5t) .071 (1.8t) .079 (2.0t) t= .031 (0.8) Panel cutout dimension mount from back side 1.573 1.16 +.02 -0 (40.0.2) (29.5 +0.5) -0 2.273 (57.8) Switched and Fused Filtered Power Entry Modules 0 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 49 Switched and Fused Filtered Power Entry Modules Switched and Fused Filtered Power Entry Modules Dual Fuse for European Applications 68-BSF Series Features Dual fuse for European applications Fuse holder and double pole power ON/OFF switch provides a convenient/compact package Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Metal case provides effective EMI shielding IEC connector meets the safety standards of most certifying agencies Easy access fuse drawer Flange-mounted UL, CSA, and SEMKO approved Designed to be in accordance with VDE 0565, part 3 Operating temperature: -25C to +85C (including temperature rise, see graph on page 51) Circuit Diagram FUSE L L L1 E CY1 CX2 CX1 E R1 L2 CY2 N N SW Applications Computers and peripheral equipment Electronic equipment Digital equipment Measuring and testing instruments Telecommunications equipment Specifications Model Rated Voltage (@ 50/60Hz) 68-BSF-020-3-01 Rated Current Leakage Current (Max.) CY1 Capacitance CY2 CX1 2A 68-BSF-020-3-04 68-BSF-040-3-01 250VAC 4A 68-BSF-040-3-04 68-BSF-060-3-01 6A 68-BSF-060-3-04 0.35mA 2200pF 2200pF CX2 0.1uF 0.1uF 0.22uF 0.22uF 0.1uF 0.1uF 0.22uF 0.22uF 0.1uF 0.1uF 0.22uF 0.22uF Inductance (L1) Temperature Rise (Max.) 10.5mH 4.2mH 45C 1.6mH Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 M min. at 500VDC Voltage Drop: 1V max. at rated current Weight: 130g Inlet: Compatible with IEC-320 B(S) = Bolt-in terminals or (Snap-in terminals) 50 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 Switched and Fused Filtered Power Entry Modules Dual Fuse for European Applications Temperature Characteristics 1.947 (49.5) 1.101 (28) .248 (6.3) 1.526 (38.8) 120 2.556 (65) Current (%) 100 80 2.348 (59.7) 60 2 - .142 (3.6) Hole 20 30 40 50 60 70 Ambient Temperature (C) 80 90 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 1 3 Filter 2 4 50 Level Meter 50 Oscillator 50 90 50 50 Level Meter 50 100 90 70 80 Insertion Loss (dB) 80 60 50 40 4 Amp 30 2 Amp 6 Amp 20 70 4 Amp 60 50 2 Amp 40 30 10 0 0.1 t= .031 (0.8) 2.399 (61) Common Mode Oscillator 50 R .059 (1.5) Panel cutout dimension mount from back side 1.573 1.16 +.02 -0 (40.0.2) (29.5 +0.5) -0 0 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (400.2) 40 20 Insertion Loss (dB) 2.340 (59.5) O.142 (3.6) Switched and Fused Filtered Power Entry Modules 68-BSF Series 6 Amp 20 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 SPECTRUM CONTROL INC. * 8031 Avonia Rd. * Fairview, PA 16415 * Phone: 814-474-2207 * Fax: 814-474-2208 * Web site: www.spectrumcontrol.com SPECTRUM CONTROL GmbH * Hansastrasse 6 * 91126 Schwabach, Germany * Phone: (49)-9122-795-0 * Fax: (49)-9122-795-58 51