CSM_G2R-_-S_(S)_DS_E_1_6
1
General-purpose Relay
G2R-@-S (S)
Slim and Space-saving Power Plug-in Relay
Reduces wiring work by 60% when combined with the
P2RF-@-PU Push-In Plus Socket
(according to actual OMRON measurements).
Lockable test button models available.
Built-in mechanical operation indicator.
Provided with nameplate.
AC type is equipped with a coil-disconnection self-diagnostic
function (LED type).
High switching power (1-pole: 10 A).
Model Number Structure
Model Number Legend
1. Number of Poles
1: 1 pole
2: 2 poles
2. Terminals
S: Plug-in
3. Classification
Blank: General-purpose
N: LED indicator
D: Diode
ND: LED indicator and diode
NI: LED indicator with test button
NDI: LED indicator and diode with test button
4. Rated Coil Voltage
5. Mechanical operation indicator and Nameplate
(S): Models with mechanical operation indicator and Nameplate
Note: Contact your OMRON representative for Relays with gold-plated contacts.
Ordering Information
List of Models
Note: 1. The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combina-
tions with the P2RF-@-E, P2RF-@-S and P2RF-@-PU. The Relays bear the CE Marking.
2. Refer to Connecting Sockets, below, for applicable Socket models.
3.
LR
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
G2R - -
123 4 5
S (S)
Whenyourorder,specifytheratedvoltage.
Classification Coil ratings Contact form
SPDT DPDT
General-purpose
AC 24, 48, 110, 120, 230, 240
DC 6, 12, 24, 48
G2R-1-S (S) G2R-2-S (S)
LED indicator G2R-1-SN (S) G2R-2-SN (S)
LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S)
Diode
DC 6, 12, 24, 48
G2R-1-SD (S) G2R-2-SD (S)
LED indicator and diode G2R-1-SND (S) G2R-2-SND (S)
LED indicator and diode with test button G2R-1-SNDI (S) G2R-2-SNDI (S)
When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.
Example: G2R-1-S 12 VDC (S)
Rated coil voltage
2
G2R-@-S (S)
Accessories (Order Separately)
Connecting Sockets
* The structure of P2RF-@-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals.
Accessories for Push-In Plus Terminal Block Sockets (P2RF-@-PU)
Short Bars
Note: Use the Short Bars for crossover wiring within one Socket or between Sockets.
* Replace the box (@) in the model number with the code for the covering color.
Labels
Mounting Tracks
*1. When mounting DIN rail, please use End Plate (PFP-M).
*2. Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
Track/surface-mounting Socket Back-mounting Socket
Applicable Relay model Push-In Plus
Terminal Blocks Screw terminals * PCB terminals Solder terminals
No. of poles Model Models Models Model
1 pole G2R-1-S (S) P2RF-05-PU P2RF-05
P2RF-05-E
P2R-05P
P2R-057P P2R-05A
2 poles G2R-2-S (S) P2RF-08-PU P2RF-08
P2RF-08-E
P2R-08P
P2R-087P P2R-08A
Pitch No. of poles Colors Model *Minimum order (quantity)
7.75 mm
2
Red (R)
Blue (S)
Yellow (Y)
PYDN-7.75-020@
10
3PYDN-7.75-030@
4PYDN-7.75-040@
20 PYDN-7.75-200@
15.5 mm 8 PYDN-15.5-080@
Model Minimum order (sheet)
(quantity per sheet)
XW5Z-P4.0LB1 5
1 sheet (60 pieces)
Applicable Socket Description Model Minimum order
(quantity)
Track-connecting Socket
Mounting track
50 cm (l) × 7.3 mm (t): PFP-50N
---
1 m (l) × 7.3 mm (t): PFP-100N
1 m (l) × 16 mm (t): PFP-100N2
End plate *1 PFP-M 10
Spacer PFP-S
Back-connecting Socket Mounting plate *2 P2R-P 1
G2R-@-S (S)
3
Specifications
Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for the AC rated current
and ±10% for the DC coil resistance.
2. The AC coil resistance and inductance values are reference values only (at 60 Hz).
3. Operating characteristics were measured at a coil temperature of 23°C.
4. The maximum voltage is the maximum possible value of the voltage that can be applied to the relay coil.
It is not the maximum voltage that can be applied continuously.
Contact Ratings
Note: P level: λ60 = 0.1 x 10-6/operation
* This value was measured at a switching frequency of 120 operations per minute.
Rated voltage
Rated current* Coil
resistance
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage Power
consumption
(approx.)
50 Hz 60 Hz Armature
OFF
Armature
ON % of rated voltage
AC
24 V 43.5 mA 37.4 mA 253 Ω0.81 1.55
80% max. 30% max. 110% 0.9 VA at 60 Hz
48 V 21.8 mA 18.8 mA 1,040 Ω3.12 6.17
110 V 9.5 mA 8.2 mA 5,566 Ω13.33 26.83
120 V 8.6 mA 7.5 mA 7,286 Ω16.13 32.46
230 V 4.4 mA 3.8 mA 27,172 Ω72.68 143.90
240 V 4.2 mA 3.7 mA 27,800 Ω90.58 182.34
Rated voltage Rated current* Coil
resistance
Coil inductance (H)
(ref. value)
Must
operate
voltage
Must
release
voltage
Max.
voltage Power
consumption
(approx.)
Armature
OFF
Armature
ON % of rated voltage
DC
6 V 87.0 mA 69 Ω0.25 0.48
70% max. 15% min. 110% 0.53 W
12 V 43.2 mA 278 Ω0.98 2.35
24 V 21.6 mA 1,113 Ω3.60 8.25
48 V 11.4 mA 4,220 Ω15.2 29.82
Number of poles 1 pole 2 poles
Load Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Rated load 10 A at 250 VAC;
10 A at 30 VDC
7.5 A at 250 VAC;
5 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 3 A at
30 VDC
Rated carry current 10 A 5 A
Max. switching voltage 440 VAC, 125 VDC 380 VAC, 125 VDC
Max. switching current 10 A 5 A
Max. switching power 2,500 VA,
300 W
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
Failure rate (reference value) * 100 mA at 5 VDC 10 mA at 5 VDC
4
G2R-@-S (S)
Characteristics
Note: Values in the above table are the initial values.
* These values are relay only. Prease refer to the “Products Related to Common Sockets and DIN Tracks Data Sheet” for connecting sockets.
Approved Standards
UL 508 (File No. E41643)
CSA 22.2 No.0, No.14
(File No. LR31928)
IEC/VDE (Certificate No. 40015012 EN 61810-1)
LR
Item 1 pole 2 poles
Contact configration SPDT
Contact structure Single
Contact resistance 100 mΩ max.
Operate (set) time 15 ms max.
Release (reset) time AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
Max. operating
frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength *
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts;
1,000 VAC, 50/60 Hz for 1 min between contacts of
same polarity
5,000 VAC, 50/60 Hz for 1 min between coil and contacts;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Malfunction: 200 m/s2 when energized; 100 m/s2 when not energized
Endurance
Mechanical: AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature Operating: –40°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 20 g
Model Contact
form Coil ratings Contact ratings Opera-
tions
G2R-1-S (S) SPDT
5 to 110 VDC
6 to 240 VAC
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use) 100 × 103
TV-3 (NO contact only) 25 × 103
G2R-2-S (S) DPDT
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use) 100 × 103
TV-3 (NO contact only) 25 × 103
Model Contact
form Coil ratings Contact ratings Opera-
tions
G2R-1-S (S) SPDT
5 to 110 VDC
6 to 240 VAC
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use) 100 × 103
TV-3 (NO contact only) 25 × 103
G2R-2-S (S) DPDT
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use) 100 × 103
TV-3 (NO contact only) 25 × 103
Contact
form Coil ratings Contact ratings Operations
1 pole
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
100 × 103
2 poles
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms) 100 × 103
Number
of poles Coil ratings Contact ratings Operations
1 pole 5 to 110 VDC
6 to 240 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
100 × 103
2 poles 5 to 110 VDC
6 to 240 VDC
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
100 × 103
G2R-@-S (S)
5
Engineering Data
Maximum Switching Power
Endurance
Ambient Temperature vs Maximum Coil Voltage
100
10
1
0.1 1 10 100 1000
100
10
1
0.11 10 100 1000
G2R-1-S (S)
Switching current (A)
Switching voltage (V)
G2R-2-S (S)
Switching voltage (V)
Switching current (A)
AC inductive load
(cosφ = 0.4) AC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
AC inductive load
(cosφ = 0.4) AC resistive
load
DC resistive
load
DC inductive load
(L/R = 7 ms)
5,000
1,000
500
100
50
5,000
1,000
500
100
50
10,000
G2R-1-S (S)
Endurance (x10
3
operations)
Switching current (A)
G2R-2-S (S)
Switching current (A)
30-VDC inductive load (L/R = 7ms)
30-VDC inductive load (L/R = 7ms)
Endurance (x10
3
operations)
250-VAC/30-VDC
resistive load
250-VAC inductive load
(cosφ = 0.4)
250-VAC/30-VDC
resistive load
250-VAC
inductive load
(cosφ = 0.4)
Ambient temperature (°C)
Maximum voltage (%)
DC coil
AC coil
6
G2R-@-S (S)
Dimensions (Unit: mm)
Note: All units are in millimeters unless otherwise indicated.
SPDT Relays
DPDT Relays
G2R-2-S (S), G2R-2-SN (S), G2R-2-SNI (S)
G2R-2-SD (S), G2R-2-SND (S), G2R-2-SNDI (S) Terminal Arrangement/Internal Connections
(Bottom View)
G2R-2-SND (S), G2R-2-SNDI (S) (DC)
G2R-2-S (S) G2R-2-SD (S) (DC)
G2R-2-SN (S), G2R-2-SNI (S) (AC) G2R-2-SN (S), G2R-2-SNI (S) (DC)
20
0.5
55
2.5
2.4
19.4
29 max.
35.5 max.
13 max.
6.2
7.4
8.9
1
8
234
765
234
567
1
8
234
765
1
8
234
765
1
8
1
8
234
765
G2R-@-S (S)
7
Track/Surface Mounting Sockets
Mounting Hole
Dimensions
Releaselever
14
12
11
A1A2
Terminal Arrangement/
Internal Connection Diagram
(Top View)
(5)
(2)
(4)
(3)
(1)
57.5
53.1
28.1
25.6
30.8
43
34.3
25.6
52.1
3.9
15.5
90
(4.2)
(4.2)
27.35
35.3
Two M3 screw
holes or
two 3.5-dia. holes
108
P2RF-05-PU
Note: Pull out the hooks to
mount the Socket
with screws.
Note: The numbers in
parentheses are
traditionally used
terminal numbers.
Mounting Hole
Dimensions
Releaselever
14
22
24
21
12
11
A1A2
Terminal Arrangement/
Internal Connection Diagram
(Top View)
(8)
(2)
(4)
(3)
(7)
(5)
(6)
(1)
57.5
27.35
35.3
53.1
28.1
25.6
30.8
43
34.3
25.6
52.1
3.9
15.5
90
(4.2)
(4.2)
Two M3 screw
holes or
two 3.5-dia. holes
108
P2RF-08-PU
Note: Pull out the hooks to
mount the Socket
with screws.
Note: The numbers in
parentheses are
traditionally used
terminal numbers.
Accessories for P2RF-@-PU
Short Bars
PYDN-7.75-@@ (7.75 mm)
PYDN-15.5-080@ (15.5 mm)
3.90
L
1.572.25
12 18.5
3.90
1.57
2.25
12 18.5
115.85
* Replace the box (@) in the model number with the code for the covering color.
Note: 1. Use the Short Bars for crossover wiring within one Socket or between Sockets.
2. When using short bar to coil terminals of PYF-@@-PU, make sure to use PYDN-31.0-
080@ (31 mm).
When using short bar to coil terminals of P2RF-@@-PU, make sure to use PYDN-15.5-
080@ (15.5 mm).
Application Pitch No. of
poles L (Length) Colors Model *Maximum
carry current
For Contact
terminals
(common)
7.75 mm
215.1
Red (R)
Blue (S)
Yellow (Y)
PYDN-7.75-020@
20 A
3 22.85 PYDN-7.75-030@
430.6 PYDN-7.75-040@
20 154.6 PYDN-7.75-200@
For Coil
terminals 15.5 mm 8 115.85 PYDN-15.5-080@
8
G2R-@-S (S)
39.5±0.1
P2RF-05
P2RF-08
7
4
2
35.5
19.5
30±0.05
7
4
2
35.5
19.5
30±0.05
P2RF-05-E
39.5
35.5
11.5
(11)
(14)
(12)
(A1)
(A2)
1
2
3
4
5
39.5±0.1
21.5
4
2
3
39.5
35.5
11.5
P2RF-08-E
8
6 3
72
54
(A1)
(A2)
(21)
(22)
(24)
(11)
(12)
(14)
1
2
3.2-dia.
hole
Five, M3.5 x 8
19.5 max.
4-dia. holes
30 max.
54 max.
4.2-dia. hole
71.5 max.
19.5 max.
Eight, M3.5 x 8
4-dia. holes
30 max.
54 max.
4.2-dia. hole
3.2-dia.
hole
Five, M3.5´7
85.5 max.
16.0 max.
48 max.
Note: Pin numbers in parentheses apply to DIN standard.
61 max.
Eight, M3´8
3.5-dia. hole
16.0 max.
48.0 max.
61.0
max.
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
M3 or
3.5-dia.
hole
M3 or
3.5-dia.
hole
3.5-dia.
hole
85.5
max.
M3 or 3.2-dia.
hole
M3 or 3.2-dia.
hole
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
Terminal Arrangement
(Top View)
Mounting Holes
(for Surface Mounting)
71.5 max.
4
7±0.2
6+0.2
0.1
G2R-@-S (S)
9
Mounting Height of Relay with Track/Surface Mounting Sockets
Back-connecting Sockets
P2RF-@P2RF-@-E
P2RF-05-PU P2RF-08-PU
G2R-@-S (S)
Relay
G2R-@-S (S)
Relay
P2RF-@-E
Socket
P2RF-@
Socket
66.5 62.0 67.0 70.5
G2R-@-S (S)
Relay
P2RF-05PU
Socket
28.1
63.6
(3.9)
G2R-@-S (S)
Relay
P2RF-08PU
Socket
28.1
63.6
(3.9)
147
6
4.5
15
4
3.5
1.2
1.5
74
4
6
4.5
15
4
7
47
0.3
5
5
20
1
2.8
1.5
7.5
7.5
5
5
20
(4.3)
(5)
P2R-05P (1-pole) 14.5 max.
35.5 max.
Tolerance: ±0.1
Mounting Holes
P2R-08P (2-pole)
36.5 max.
Terminal plate thickness: 0.3
14.5 max.
35.5 max.
Eight, 1.3-dia. holes
Terminal Arrangement
(Bottom View)
Mounting HolesTerminal Arrangement
(Bottom View)
Five,
1.6-dia.
holes
36.5 max.
10
G2R-@-S (S)
Mounting Height of Relay with Back-connecting Sockets
4.5
1.2
0.3
6.7
3.8
16.7 5
6
1.2
0.3
5
5
20
2.8
2.6
7.5
13.6±0.1
30.5±0.2
1.5
7.5
7.56.5
P2R-05A (1-pole)
Panel Cutout
P2R-08A (2-pole)
Five, 3 x 1.8-dia. holes
36.5 max.
Terminal plate thickness: 0.3
14.5 max.
35.5 max.
36.5 max.
Terminal plate thickness: 0.3
14.5 max.
35.5 max.
Eight, 3 x 1.2-dia. holes
Terminal Arrangement
(Bottom View)
Recommended thickness of
the panel is 1.6 to 2.0 mm
P2R-057P (1-pole)
P2R-087P (2-pole)
4.5±0.1 15±0.1
4±0.1
5
4±0.1
6±0.1
7±0.1
7.5
5
5
20
(8.1)
29.6
0.7
8.9
8.7
8.7
29.1
7.5
14 max.
37 max.
14 max.
37 max.
41 max.
Mounting Holes
Terminal Arrangement
(Bottom View)
Mounting Holes
Terminal Arrangement
(Bottom View) Eight,
1.3-dia.
holes
Five,
1.6-dia.
holes
7.4
1
0.3
16.4
110.4 3.5
5
20
8.1
5
16.4
110.4
1
1
7.4
41 max.
3.5
6
15
4
8.75
4.5
38.0
P2R-@7P
G2R-@-S (S) Relay
P2R-@P
Socket P2R-@A
Socket
G2R-@-S (S) Relay
P2R-@7P
Socket
G2R-@-S (S) Relay
P2R-@P P2R-@A
47.5
44.5
G2R-@-S (S)
11
Mounting Tracks
End Plate Spacer
Mounting Plate
P2R-P
Safety Precautions
Be sure to read the Common Precautions for All Relay in the website at the following URL:
http://www.ia.omron.com/.
Refer to Products Related to Common Sockets and DIN Tracks for precautions on the applicable Sockets.
Refer to PYF-
@@
-PU/P2RF-
@@
-PU for precautions on Push-In Plus Terminal Block Sockets.
Warning Indications
Do not use the test button for any purpose other than testing. Be
sure not to touch the test button accidentally as this will turn the
contacts ON. Before using the test button, confirm that circuits, the
load, and any other connected item will operate safely.
Check that the test button is released before turning ON relay cir-
cuits.
If the test button is pulled out too forcefully, it may bypass the mo-
mentary testing position and go straight into the locked position.
Use an insulated tool when you operate the test button.
PFP-100N, PFP-50N PFP-100N2
4.5
15 25 25 25 25
10 10
1,000 (500)
7.3±0.15
35±0.3 27±0.15
1
4.5
15 25 25 25 25 15
10 10
1,000
35±0.3 27 24
16
29.2
1 1.5
15 (5)
It is recommended to use a panel 1.6 to 2.0 mm thick.
PFP-M PFP-S
50
11.5
10
6.2 1.8
1
35.5 35.3
1.8
1.3
4.8
5
16
12
44.3 34.8
10
16.5
M4 x 8 pan
head screw
90 4.5
49 42
±0.1
9
±0.1
9
±0.1
18
±0.15
18
±0.15
18
±0.15
72
±0.2
18
±0.15
R2.25
10-Ellipsehole
13.6
Squarehole
3.4
30.5
t=1.6 mm
CAUTION
Indicates a potentially hazardous
situation which, if not avoided, may result
in minor or moderate injury or in property
damage.
Cation
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omrons exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omrons sole obligation hereunder shall be, at
Omrons election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyers application or use of the Product. At Buyers request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the users programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omrons test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omrons Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omrons representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2019.7
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/ (c)