Correct Use
IDC Connectors
•For best results, use only the XG5 IDC
To o l .
•Contact your OMRON representative for
details on the XG5 IDC Tool.
•Check the Contact size (No. 1 or No 2)
and wire size before connecting.
•OMRON has a IDC Tool Reference Man-
ual. Contact your OMRON representative
to request a copy.
Mounting the Cover
•The cover is used to protect the connec-
tion position and prevent shorting out.
Mounting the Semi-cover
•See the above diagram.
1. Insert part A of the Semi-cover into part
B of the Socket.
2. Push the claws on both sides of the
Semi-cover onto the Socket.
3. Make sure the claws are firmly inserted
in the slots.
4. To protect the wires, use cable ties to
bind wires that may be subject to ten-
sion even when a Semi-cover is used.
Mounting the Hood Cover
Vertical Hood Cover
•See the above diagram.
1. Insert the claws of part A of the Hood
Cover into the slots.
2. Insert claws B on the Hood cover into
part C on the other part of the Hood
Cover.
3. Wrap the wires with a cable tie.
Horizontal Hood Cover
•Follow the mounting procedure for the
vertical cover.
•The left and right parts of the cover are
different. Assemble carefully.
XG5M-N Double-row Socket Contact
Numbers
XG4M Contact Numbers
•The Contact numbers on the Double-row
Assembled Socket match the numbers on
the XG4M Flat Cable MIL Socket. (See
the above diagrams.)
•When making IDC connections on the
Double-row Assembled Connector, use
the polarity guide to distinguish the front
and back. (Note: The 10-contact Connec-
tor does not have a guide.)
Applicable Plugs
•XG4A, XG4C and XG8 are recom-
mended.
•XG4C and XG8 Plugs do not have locks.
To p r event accidental removal, use a Lock
Lever (XG4Z-0002, XG5Z-0002). (Lock
Levers cannot be used with XG8W
Straight Terminal Connectors.)
•When mounting the XG8 Original Plug
(with right-angle terminals) to a circuit
board, be sure that the cover is positioned
off the board as shown below.