7-969
Specifications CD4066BMS
Control Input High
Voltage (See Figure 2) VIHC10 VDD = 10V, VIS = VDD or GND 2 +25oC, +125oC,
-55oC7-V
Propagation Delay
Signal Input to
Signal Output
TPLH
TPHL VDD = 10V 1, 2, 3 +25oC - 20 ns
VDD = 15V 1, 2, 3 +25oC - 15 ns
Propagation Delay
Turn-On, Turn-Off TPHZ/ZH
TPLZ/ZL VDD = 10V 1, 2, 3 +25oC - 40 ns
VDD = 15V 1, 2, 3 +25oC - 30 ns
Input Capacitance CIN Any Input 1, 2 +25oC - 7.5 pF
NOTES:
1. All voltages referenced to device GND.
2. The parameters listed on Table 3 are controlled via design or process and are not directly tested. These parameters are characterized
on initial design release and upon design changes which would affect these characteristics.
3. CL = 50pF, RL = 200K, Input TR, TF < 20ns.
TABLE 4. POST IRRADIATION ELECTRICAL PERFORMANCE CHARACTERISTICS
PARAMETER SYMBOL CONDITIONS NOTES TEMPERATURE
LIMITS
UNITSMIN MAX
Supply Current IDD VDD = 20V, VIN = VDD or GND 1, 4 +25oC-25µA
N Threshold Voltage VNTH VDD = 10V, ISS = -10µA 1, 4 +25oC -2.8 -0.2 V
N Threshold Voltage
Delta ∆VTN VDD = 10V, ISS = -10µA 1, 4 +25oC-±1V
P Threshold Voltage VTP VSS = 0V, IDD = 10µA 1, 4 +25oC 0.2 2.8 V
P Threshold Voltage
Delta ∆VTP VSS = 0V, IDD = 10µA 1, 4 +25oC-±1V
Functional F VDD = 18V, VIN = VDD or GND 1 +25oC VOH >
VDD/2 VOL <
VDD/2 V
VDD = 3V, VIN = VDD or GND
Propagation Delay Time TPHL
TPLH VDD = 5V 1, 2, 3, 4 +25oC - 1.35 x
+25oC
Limit
ns
NOTES: 1. All voltages referenced to device GND.
2. CL = 50pF, RL = 200K, Input TR, TF < 20ns. 3. See Table 2 for +25oC limit.
4. Read and Record
TABLE 5. BURN-IN AND LIFE TEST DELTA PARAMETERS +25OC
PARAMETER SYMBOL DELTA LIMIT
Supply Current - SSI IDD ±0.1µA
ON Resistance RONDEL10 ± 20% x Pre-Test Reading
TABLE 6. APPLICABLE SUBGROUPS
CONFORMANCE GROUP MIL-STD-883
METHOD GROUP A SUBGROUPS READ AND RECORD
Initial Test (Pre Burn-In) 100% 5004 1, 7, 9 IDD, IOL5, IOH5A, RONDEL10
Interim Test 1 (Post Burn-In) 100% 5004 1, 7, 9 IDD, IOL5, IOH5A, RONDEL10
Interim Test 2 (Post Burn-In) 100% 5004 1, 7, 9 IDD, IOL5, IOH5A, RONDEL10
PDA (Note 1) 100% 5004 1, 7, 9, Deltas
Interim Test 3 (Post Burn-In) 100% 5004 1, 7, 9 IDD, IOL5, IOH5A, RONDEL10
PDA (Note 1) 100% 5004 1, 7, 9, Deltas
TABLE 3. ELECTRICAL PERFORMANCE CHARACTERISTICS (Continued)
PARAMETER SYMBOL CONDITIONS NOTES TEMPERATURE
LIMITS
UNITSMIN MAX