1
CSM_E2E_DS_E_3_1
Standard Proximity Sensor
E2E
Your Search for Proximity Sensors
Starts with the World-leading
Performance and Quality of the E2E
Standard Sensors for detecting ferrous metals.
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent
mutual interference.
Superior environment resistance with standard cable made of oil-
resistant PVC and sensing surface made of material that resists
cutting oil.
Cable protector provided as a standard feature.
Be sure to read Safety Precautions on
page 28.
*1: No AC/DC 2-wire models or AC 2-wire M8 models are compliant.
*2: Attach three ferrite clamps to the cable of the E2E-X3@@ and
E2E-X8MD@. (Refer to information on TDK catalog number
ZCAT2035-0930A.)
*1, *2
Features
Pre-wired Models with Oil-resistant Reinforced PUR Cables Added
to the Lineup and Easy Differentiation with Orange Head
Lineup includes models with Smartclick pre-wired connectors for fast connection.
2-Wire Models
Oil Resistance
Oil Resistance
Cable Flexibility
Cable Flexibility
Cable Flexibility
Cable Flexibility at
Cable Flexibility at
Low Temperatures
Low Temperatures
Oil Resistance (Insulation service life):
twice or three times
that of oil-resistant vinyl chloride
Cable Flexibility:
approximately twice
that of cinyl chloride cables
More Flexibility at 40°C
Oil Resistance
Cable Flexibility at
Low Temperatures
Differentiation from standard
models: Orange Head
XS5 Smartclick connectors used to
enable checking connector mating
Jacket: Polyester elastomer
Insulation: Oil-resistant grade PUR (polyurethane)
1/8 turn
Insert all
the way.
Click
2
E2E
Lineup includes models with self-diagnostic output to provide notification of failures and
unstable detection conditions, such as coil burnout.
Contributes to preventive maintenance to keep the line from stopping.
Reduced wiring, fewer resources, and low power consumption contribute to
environmentalism.
Wiring work and amount of copper wire used reduced to two thirds of that required for 3-wire models.
Current consumption drastically reduced to less than 10% (when a DC 2-wire model is compared with a DC 3-wire model).
Lineup includes models with small diameter (3 dia., 4 dia., 5.4 dia., M5)
All small-diameter models use sealed construction. Operation is stable even when the Sensor is mounted in a small space or embedded in metal.
Bright indicators enable easily checking the installation condition.
Wide range of ambient operating temperatures: 40°C to 85°C (M8 to M30 models)
Wide range of ambient operating temperatures also for small-diameter models: 25°C to 70°C
Suitable for low-temperature and high-temperature applications, which are troublesome for photoelectric sensors.
Lineup includes models with flexible cable (4-dia. to M30 models)
Reduced risk of disconnection in applications with moving parts.
3-Wire Models
E2E
3
Models Listed by E2E Type
: Standard Models, : Different frequency, @: Self-diagnosis, : Different frequency and self-diagnosis,
---: Not listed
2-Wire Models
Power
supply
Shielding
Size and sensing distance
Polarity
Operation
mode
Oil-resistant
reinforced
PUR cable
Standard cable and flexible cable
(cable material: oil-resistant PVC)/Connector models Page
M12 pre-wired
smartclick
connector models
Pre-wired model
with 2-m
cable
M12 pre-wired
smartclick
connector models
Pre-wired model
with standard
2-m cable
Pre-wired model
with flexible
2-m cable
Pre-wired model
with standard
5-m cable
M12 connector (IEC
pin arrangement)
M12 standard
pre-wired
connector models
M8 connector
M12 connector (old
pin arrangement)
Ordering
Information
Dimensions refer-
ence chart
DC
Shield-
ed
M8
2 m Yes NO ●●● ●●●--- ●●
Refer to
page 7.
Refer to
Models
with Self-
diagnostic
Output on
page 8.
Refer to
Models
with con-
ventional
connector
pin assign-
ments on
page 9.
Refer
to page
30.
NC --- --- ---
M12
3 mm
Yes NO ●●●@■● @---
NC --- --- ●●●---
No NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --- ---
M18
7 mm
Yes NO ●●●@■● @---
NC --- --- ●●●---
No NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
M30
10 mm
Yes NO ●●●@■● @---
NC --- --- --- ---
No NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
Un-
shield-
ed
M8
4 mm
Yes
NO --- --- --- ●●--- ●●
Refer to
page 8.
Refer to
Models
with Self-
diagnostic
Output or
Models
with con-
ventional
connector
pin assign-
ments on
page 9.
NC --- --- --- --- --- ---
M12
8 mm
NO --- --- ●●@■● @---
NC --- --- --- --- --- --- ---
M18
14 mm
NO --- --- ●●@■● @---
NC --- --- --- --- --- ---
M30
20 mm
NO --- --- ●●@■● @---
NC --- --- --- --- --- --- ---
AC
Shield-
ed
M8
1.5 mm
---
NO --- --- --- --- --- --- --- --- ---
Refer
to page
10.
NC --- --- --- --- --- --- --- --- ---
M12
2 mm
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
M18
5 mm
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
M30
10 mm
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
Un-
shield-
ed
M8
2 mm
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
M12
5 mm
NO --- --- --- ●▲ --- ●●--- --- ---
NC --- --- --- --- --- --- --- ---
M18
10 mm
NO --- --- --- ●▲ --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
M30
18 mm
NO --- --- --- ●▲ --- --- --- --- ---
NC --- --- --- --- --- --- --- ---
AC/DC Shield-
ed
M12
2 mm
---
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --- ---
M18
5 mm
NO --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --- ---
M30
10 mm
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- --- ---
4
E2E
: Standard Models, : Different frequency, ---: Not listed
3-Wire Models
Power
supply
Shielding
Size and sensing distance
Polarity
Operation
mode
Oil-resistant
reinforced
PUR cable
Standard cable and flexible cable
(cable material: oil-resistant PVC)/Connector models Page
M12 pre-wired
smartclick
connector models
Pre-wired model
with 2-m cable
M12 pre-wired
smartclick
connector models
Pre-wired model
with standard
2-m cable
Pre-wired model
with flexible
2-m cable
Pre-wired model
with standard
5-m cable
M12 connector (IEC
pin arrangement)
M12 standard pre-
wired
connector models
M8 connector
e-CON pre-wired
connector models
Ordering
Information
Dimensions refer-
ence chart
DC
NPN
Shield-
ed
3 dia.
0.6 mm
Yes
NO --- --- --- --- --- --- --- --- ---
Refer
to page
11.
Refer
to page
30.
NC --- --- --- --- --- --- --- --- ---
4 dia.
0.8 mm
NO --- --- --- ●●--- --- --- ---
NC --- --- --- --- --- --- --- --- ---
M5
1 mm
NO --- --- --- ●●--- --- --- ---
NC --- --- --- --- --- --- --- --- ---
5.4 dia.
1 mm
NO --- --- --- ●●--- --- --- ---
NC --- --- --- --- --- --- --- --- ---
M8
1.5mm
NO --- --- --- ●●--- ---
NC --- --- --- --- --- --- ---
M12
2 mm
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- --- ---
M18
5 mm
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- --- ---
M30
10 mm
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- --- ---
Un-
shield-
ed
M8
2 mm
NO --- --- --- ●●--- --- ---
Refer
to page
12.
NC --- --- --- --- --- --- ---
M12
5 mm
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- --- ---
M18
10 mm
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- --- ---
M30
18 mm
NO --- --- --- ●▲ --- ---
NC --- --- --- --- --- --- --- ---
DC
PNP
Shield-
ed
3 dia.
0.6 mm
Yes
NO --- --- --- --- --- --- --- --- ---
Refer
to page
11.
NC --- --- --- --- --- --- --- --- ---
4 dia.
0.8 mm
NO --- --- --- ●●--- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
M5
1 mm
NO --- --- --- ●●--- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
5.4 dia.
1 mm
NO --- --- --- --- --- --- --- --- ---
NC --- --- --- --- --- --- --- --- ---
M8
1.5mm
NO --- --- --- ●●--- ---
NC --- --- --- --- --- --- ---
M12
2 mm
NO --- --- --- ●▲ --- --- ---
NC --- --- --- --- --- --- --- ---
M18
5 mm
NO --- --- --- ●▲ --- --- ---
NC --- --- --- --- --- --- --- ---
M30
10 mm
NO --- --- --- ●●--- --- --- ---
NC --- --- --- --- --- --- --- ---
Un-
shield-
ed
M8
2 mm
NO --- --- --- ●●--- --- ---
Refer
to page
12.
NC --- --- --- --- --- --- ---
M12
5 mm
NO --- --- --- ●●--- --- --- ---
NC --- --- --- --- --- --- --- ---
M18
10 mm
NO --- --- --- ●●--- --- --- ---
NC --- --- --- --- --- --- --- ---
M30
18 mm
NO --- --- --- ●●--- --- --- ---
NC --- --- --- --- --- --- --- ---
E2E
5
E2E Guide to Selection by Purpose
Environment
Maintenance
Reducing troubles Higher oil resistance
Easy replacement
Reducing stocked
models
Wide operating
temperature range
Resists the influence of surrounding metal
Mutual interference
prevention
Miswiring measures
Early discovery
of problems
AC/DC 2-Wire Models
E2E-X@T1
Connector Models
E2E-X@D@-M1(G)
E2E-X@E@-M1
E2E-X@Y@-M1
Pre-wired Connector
Models
E2E-X@D1-M1(G)J-(T)
Smartclick Pre-wired
Connector Models
E2E-X@D@-M1TGJ-(U)
Models with Oil-resistor
reinforced PUR cable
E2E-X@D@-U
Models with a Different
Frequency (NO Models
only)
E2E-X@@15
DC 2-Wire Models
E2E-X@D@
DC 3-Wire Models
E2E-X@E@
DC 2-Wire
No-polarity Models
E2E-X@D1-M1J-T
Diagnostic Models
E2E-X@D1S
40 to 85°C
AC 2-wire: M12 to M30,
DC 3-wire: M8 to M30
25 to 70°C
Models not listed above.
Shielded Models
DC 2-Wire Models
E2E-X@D@
NPN/PNP output
AC/DC
Load short-circuit
protection
No polarity
Mounting to moving
parts Robotics Cable Models
E2E-X@D1-R
E2E-X@E1-R
Robotics cable
Note: Refer to Models Not Listed in this Catalog for Long Body Models, Transmission Couplers, and Power Couplers.
Reinforced
Standard Models with Oil-resistant PVC
cable
6
E2E
E2E Model Number Legend
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.
Models are not available for all combinations of code numbers.
Ask your OMRON representative if you require a customized model.
E2E- ABCDEFG H I - J - K - L-M
No. Classification Code Meaning Remarks
AAppearance C Cylindrical (not threaded)
X Cylindrical (threaded)
BSensing distance
Number Sensing distance (Unit: mm) Example:
R6: 0.6 mm
1R5: 1.5 mm
R Indication of decimal point
CShielding Blank Shielded Models
M Unshielded Models
DPower supply and output
specifications
B DC 3-wire PNP open-collector output
Whether D models have
polarity is defined by num-
ber J.
C DC 3-wire NPN open-collector output
D DC 2-wire polarity/no polarity
E DC 3-wire NPN collector load built-in output
F DC 3-wire PNP collector load built-in output
T AC/DC 2-wire
Y AC 2-wire
EForm of output switching el-
ement
1 Normally open (NO)
2 Normally closed (NC)
FOscillation frequency type Blank Standard frequency Used to prevent mutual in-
terference.
5 Different frequency
GSelf-diagnosis Blank No
5Yes
HConnection method
Blank Pre-wired
M1 M12-size metal connector
M3 M8-size metal connector
IConnector specifications
Blank
Connector Models
DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output,
DC 2-wire with old pin arrangement (polarity)
GConnector Models
DC 2-wire with IEC pin arrangement (polarity)
J
Pre-wired Connector Models
DC 3-wire and AC 2-wire, DC 2-wire with IEC pin arrangement
(polarity), DC 3-wire and AC 2-wire, DC 2-wire with self-diagno-
sis output, DC 2-wire with old pin arrangement (polarity)
GJ Pre-wired Connector Models
DC 2-wire with IEC pin arrangement (polarity)
TJ Pre-wired Smartclick Connector Models
DC 2-wire with IEC pin arrangement (no polarity)
TGJ Pre-wired Smartclick Connector Models
DC 2-wire with IEC pin arrangement (polarity)
JDC 2-wire polarity Blank Polarity
T No polarity
KCable specifications
Blank Standard PVC cable (oil resistant)
R Flexible PVC cable (oil resistant)
U Polyurethane cable (oil resistant and reinforced)
LNew model N New model (Applies only to DC 2-wire pre-wired and shielded
models.)
This is blank if the cable
specification in number K
is R or U.
MCable length Letter M Cable length (Unit: m) (Applicable to Pre-wired Models and Pre-
wired Connector Models.)
Example:
2M
0.3M
E2E
7
Ordering Information
Shielded DC 2-wire Models with No Self-diagnostic Output [Refer to Dimensions on page 30.]
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X3D15-N 2M).
*2. Models with a flexible cable are also available. Add "-R" rather than "-N" to the end of the model number (example: E2E-X2D1-R 2M).
*3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X3D1-N 5M)
*4. Refer to page 24 for details.
*5. The residual voltage for models without polarity is 5 V, so use caution concerning the connection load interface conditions (e.g., PLC ON voltage). Refer to page 29.
*6. The standard cable length is 300 mm. Cables with a length of 500 mm and 1 m can also be manufactured.
2-Wire Models
Appear-
ance Sensing distance Connection
method
Cable
specifications
Polar-
ity
Opera-
tion
mode
Pin
arrangement
Applicable
connector
code *4
Model
M8
M12 Pre-wired Smart-
click Connector Mod-
els (0.3m)
PUR (increased
oil-resistant)
Yes
NO 1: +V, 4: 0 V
H
E2E-X2D1-M1TGJ-U 0.3M
NC 1: +V, 2: 0 V E2E-X2D2-M1TGJ-U 0.3M
PVC (oil-resistant) NO 1: +V, 4: 0 V E2E-X2D1-M1TGJ 0.3M
Pre-wired Models
(2 m)
PUR (increased
oil-resistant)
NO
--- ---
E2E-X2D1-U 2M
NC E2E-X2D2-U 2M
PVC (oil-resistant) NO E2E-X2D1-N 2M *2*3
NC E2E-X2D2-N 2M *3
M12 Connector Mod-
els --- NO 1: +V, 4: 0 V A, B, D E2E-X2D1-M1G
NC 1: +V, 2: 0 V D E2E-X2D2-M1G
M8 Connector Models --- NO 1: +V, 4: 0 V GE2E-X2D1-M3G
NC 1: +V, 2: 0 V E2E-X2D2-M3G
M12
M12 Pre-wired Smart-
click Connector Mod-
els (0.3m)
PUR (increased
oil-resistant)
Yes
NO 1: +V, 4: 0 V
H
E2E-X3D1-M1TGJ-U 0.3M
NC 1: +V, 2: 0 V E2E-X3D2-M1TGJ-U 0.3M
PVC (oil-resistant) NO 1: +V, 4: 0 V E2E-X3D1-M1TGJ 0.3M
Pre-wired Models
(2 m)
PUR (increased
oil-resistant)
NO
--- ---
E2E-X3D1-U 2M
NC E2E-X3D2-U 2M
PVC (oil-resistant) NO E2E-X3D1-N 2M *1*2*3
NC E2E-X3D2-N 2M *3
M12 Connector Mod-
els --- NO 1: +V, 4: 0 V A, B, D E2E-X3D1-M1G *1
NC 1: +V, 2: 0 V D E2E-X3D2-M1G
M12 Standard Pre-
wired Connector Mod-
els (0.3 m) *6
PVC (oil-resistant)
Yes NO 1: +V, 4: 0 V A, B, D E2E-X3D1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X3D2-M1GJ 0.3M
No *5NO (3, 4): (+V, 0 V) A, B, D E2E-X3D1-M1J-T 0.3M
NC (1, 2): (+V, 0 V) D ---
M18
M12 Pre-wired Smart-
click Connector Mod-
els (0.3m)
PUR (increased
oil-resistant)
Yes
NO 1: +V, 4: 0 V
H
E2E-X7D1-M1TGJ-U 0.3M
NC 1: +V, 2: 0 V E2E-X7D2-M1TGJ-U 0.3M
PVC (oil-resistant) NO 1: +V, 4: 0 V E2E-X7D1-M1TGJ 0.3M
Pre-wired Models
(2 m)
PUR (increased
oil-resistant)
NO
--- ---
E2E-X7D1-U 2M
NC E2E-X7D2-U 2M
PVC (oil-resistant) NO E2E-X7D1-N 2M *1*2*3
NC E2E-X7D2-N 2M *3
M12 Connector Mod-
els --- NO 1: +V, 4: 0 V A, B, D E2E-X7D1-M1G *1
NC 1: +V, 2: 0 V D E2E-X7D2-M1G
M12 Standard Pre-
wired Connector Mod-
els (0.3 m) *6
PVC (oil-resistant)
Yes NO 1: +V, 4: 0 V A, B, D E2E-X7D1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X7D2-M1GJ 0.3M
No *5NO (3, 4): (+V, 0 V) A, B, D E2E-X7D1-M1J-T 0.3M
NC (1, 2): (+V, 0 V) D E2E-X7D2-M1J-T 0.3M
M30
M12 Pre-wired Smart-
click Connector Mod-
els (0.3m)
PUR (increased
oil-resistant)
Yes
NO 1: +V, 4: 0 V
H
E2E-X10D1-M1TGJ-U 0.3M
NC 1: +V, 2: 0 V E2E-X10D2-M1TGJ-U 0.3M
PVC (oil-resistant) NO 1: +V, 4: 0 V E2E-X10D1-M1TGJ 0.3M
Pre-wired Models
(2 m)
PUR (increased
oil-resistant)
NO
--- ---
E2E-X10D1-U 2M
NC E2E-X10D2-U 2M
PVC (oil-resistant) NO E2E-X10D1-N 2M *1*2*3
NC E2E-X10D2-N 2M
M12 Connector Mod-
els --- NO 1: +V, 4: 0 V A, B, D E2E-X10D1-M1G *1
NC 1: +V, 2: 0 V D E2E-X10D2-M1G
M12 Standard Pre-
wired Connector Mod-
els (0.3 m) *6
PVC (oil-resistant)
Yes NO 1: +V, 4: 0 V A, B, D E2E-X10D1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X10D2-M1GJ 0.3M
No *5NO (3, 4): (+V, 0 V) A, B, D E2E-X10D1-M1J-T 0.3M
NC (1, 2): (+V, 0 V) D E2E-X10D2-M1J-T 0.3M
2 mm
3 mm
7 mm
10 mm
8
E2E
Unshielded DC 2-Wire Models with No Self-diagnosis Output [Refer to Dimensions on page 30.]
*1. Models with different frequencies are also available. The model number is E2E-X @D15 (example: E2E-X8MD15 2M).
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X4MD1-R 2M).
*3. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X4MD1 5M)
*4. Refer to page 24 for details.
Shielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 30.]
*1. Models with different frequencies are also available. The model number is E2E-X @D15S (example: E2E-X3D15S 2M).
*2. Refer to page 24 for details.
2-Wire Models
Appear-
ance Sensing distance Connection
method
Cable
specifications
Polar-
ity
Opera-
tion
mode
Pin
arrangement
Applicable
connector
code *4
Model
M8
Pre-wired Models (2 m) PVC (oil-resistant)
Yes
NO --- --- E2E-X4MD1 2M *2*3
NC E2E-X4MD2 2M
M12 Connector Models --- NO 1: +V, 4: 0 V A, B, D E2E-X4MD1 2M
NC 1: +V, 2: 0 V D E2E-X4MD2-M1G
M8 Connector Models --- NO 1: +V, 4: 0 V GE2E-X4MD1-M3G
NC 1: +V, 2: 0 V E2E-X4MD2-M3G
M12
12M Pre-wired Smart-
click Connector Models
(0.3m)
PVC (oil-resistant) NO 1: +V, 4: 0 V H E2E-X8MD1-M1TGJ 0.3M
Pre-wired Models (2 m) PVC (oil-resistant) NO --- --- E2E-X8MD1 2M *1*2*3
NC E2E-X8MD2 2M
M12 Connector Models --- NO 1: +V, 4: 0 V A, B, D E2E-X8MD1-M1G *1
NC 1: +V, 2: 0 V D E2E-X8MD2-M1G
M12 Standard Pre-
wired Connector Mod-
els (0.3 m)
PVC (oil-resistant)
NO 1: +V, 4: 0 V A, B, D E2E-X8MD1-M1GJ 0.3M
NC 1: +V, 2: 0 V D ---
M18
12M Pre-wired Smart-
click Connector Models
(0.3m)
PVC (oil-resistant) NO 1: +V, 4: 0 V H E2E-X14MD1-M1TGJ 0.3M
Pre-wired Models (2 m) PVC (oil-resistant) NO --- --- E2E-X14MD1 2M *1*2*3
NC E2E-X14MD2 2M
M12 Connector Models --- NO 1: +V, 4: 0 V A, B, D E2E-X14MD1-M1G *1
NC 1: +V, 2: 0 V D E2E-X14MD2-M1G
M12 Standard Pre-
wired Connector Mod-
els (0.3 m)
PVC (oil-resistant)
NO 1: +V, 4: 0 V A, B, D E2E-X14MD1-M1GJ 0.3M
NC 1: +V, 2: 0 V D E2E-X14MD2-M1GJ 0.3M
M30
12M Pre-wired Smart-
click Connector Models
(0.3m)
PVC (oil-resistant) NO 1: +V, 4: 0 V H E2E-X20MD1-M1TGJ 0.3M
Pre-wired Models (2 m) PVC (oil-resistant) NO --- --- E2E-X20MD1 2M *1*2*3
NC E2E-X20MD2 2M
M12 Connector Models --- NO 1: +V, 4: 0 V A, B, D E2E-X20MD1-M1G *1
NC 1: +V, 2: 0 V D E2E-X20MD2-M1G
M12 Standard Pre-
wired Connector Mod-
els (0.3 m)
PVC (oil-resistant)
NO 1: +V, 4: 0 V A, B, D E2E-X20MD1-M1GJ 0.3M
NC 1: +V, 2: 0 V D ---
4 mm
8 mm
14 mm
20 mm
Appear-
ance Sensing distance Connection
method
Cable
specifications
Polar-
ity
Opera-
tion
mode
Pin
arrangement
Applicable
connector
code *2
Model
M12
Pre-wired Models
(2 m) PVC (oil-resistant)
Yes NO
--- --- E2E-X3D1S 2M *1
M12 Connector
Models ---
2: +V and diagnostic output
3: 0 V
4: +V and control output
DE2E-X3D1S-M1
M18
Pre-wired Models
(2 m) PVC (oil-resistant) --- --- E2E-X7D1S 2M *1
M12 Connector
Models ---
2: +V and diagnostic output
3: 0 V
4: +V and control output
DE2E-X7D1S-M1
M30
Pre-wired Models
(2 m) PVC (oil-resistant) --- --- E2E-X10D1S 2M *1
M12 Connector
Models ---
2: +V and diagnostic output
3: 0 V
4: +V and control output
DE2E-X10D1S-M1
3 mm
7 mm
10 mm
E2E
9
Unshielded DC 2-Wire Models with Self-diagnosis Output [Refer to Dimensions on page 30.]
*1. Models with different frequencies are also available. The model number is E2E-X @MD15S (example: E2E-X8MD15S 2M).
*2. Refer to page 24 for details.
Connector Pin Assignments of DC 2-Wire Models
The connector pin assignments of each New E2E DC 2-Wire Model
conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have
been changed in comparison to the previous models.)
The following models with conventional connector pin assignments
are available as well. (Only NO Models can be used.)
The cable at the right should also be used if the XW3A-P@45-G11
Connector Junction Box is already being used.
Models with conventional connector pin assignments are available as well.
Note: Refer to page 24 for details.
2-Wire Models
Appear-
ance Sensing distance Connection
method
Cable
specifications
Polar-
ity
Opera-
tion
mode
Pin
arrangement
Applicable
connector
code *2
Model
M12
Pre-wired Mod-
els (2 m) PVC (oil-resistant)
Yes NO
--- --- E2E-X8MD1S 2M *
M12 Connector
Models ---
2: +V and diagnostic output
3: 0 V
4: +V and control output
DE2E-X8MD1S-M1
M18
Pre-wired Mod-
els (2 m) PVC (oil-resistant) --- --- E2E-X14MD1S 2M *
M12 Connector
Models ---
2: +V and diagnostic output
3: 0 V
4: +V and control output
DE2E-X14MD1S-M1
M30
Pre-wired Mod-
els (2 m) PVC (oil-resistant) --- --- E2E-X20MD1S 2M *
M12 Connector
Models ---
2: +V and diagnostic output
3: 0 V
4: +V and control output
DE2E-X20MD1S-M1
8 mm
14 mm
20 mm
Cable length Model
500 mm XS2W-D421-BY1
3
4
4
1
Internal Wiring
(Proximity Sensor end) (Wired end)
Appearance Model
NO Applicable connector code *NC Applicable connector code *
M8 E2E-X2D1-M1 CE2E-X2D2-M1 D
M12 E2E-X3D1-M1 CE2E-X3D2-M1 D
M18 E2E-X7D1-M1 CE2E-X7D2-M1 D
M30 E2E-X10D1-M1 CE2E-X10D2-M1 D
M8 E2E-X4MD1-M1 CE2E-X4MD2-M1 D
M12 E2E-X8MD1-M1 CE2E-X8MD2-M1 D
M18 E2E-X14MD1-M1 CE2E-X14MD2-M1 D
M30 E2E-X20MD1-M1 CE2E-X20MD2-M1 D
Shielded
Unshielded
10
E2E
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 30.]
*1. Models with different frequencies are also available. The model number is E2E-X @Y@5 (example: E2E-X5Y15 2M).
*2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2Y1 5M)
*3. Refer to page 24 for details.
Unshielded Models
*1. Models with different frequencies are also available. The model number is E2E-X @MY@5 (example: E2E-X5MY15 2M).
*2. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X5MY1 5M)
*3. Refer to page 24 for details.
AC 2-Wire Models Shielded Models [Refer to Dimensions on page 30.]
(There are no unshielded models.)
Note: Not compliant with CE.
* The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X7T1 5M)
2-Wire Models
Appear-
ance Sensing distance Connection
method
Cable
specifications
Operation
mode
Pin
arrangement
Applicable con-
nector code *3Model
M8 Pre-wired Models
(2 m) PVC (oil-resistant) NO --- --- E2E-X1R5Y1 2M
NC E2E-X1R5Y2 2M
M12
Pre-wired Models
(2 m) PVC (oil-resistant) NO --- --- E2E-X2Y1 2M *1*2
NC E2E-X2Y2 2M
M12 Connector
Models --- NO (3, 4): (AC, AC) E, F E2E-X2Y1-M1
NC (1, 2): (AC, AC) F E2E-X2Y2-M1
M18
Pre-wired Models
(2 m) PVC (oil-resistant) NO --- --- E2E-X5Y1 2M *1*2
NC E2E-X5Y2 2M
M12 Connector
Models --- NO (3, 4): (AC, AC) E, F E2E-X5Y1-M1
NC (1, 2): (AC, AC) F E2E-X5Y2-M1
M30
Pre-wired Models
(2 m) PVC (oil-resistant) NO --- --- E2E-X10Y1 2M *1*2
NC E2E-X10Y2 2M
M12 Connector
Models --- NO (3, 4): (AC, AC) E, F E2E-X10Y1-M1
NC (1, 2): (AC, AC) F E2E-X10Y2-M1
1.5 mm
2 mm
5 mm
10 mm
Appear-
ance Sensing distance Connection
method
Cable
specifications
Operation
mode
Pin
arrangement
Applicable con-
nector code *3Model
M8 Pre-wired Models
(2 m) PVC (oil-resistant) NO --- --- E2E-X2MY1 2M
NC E2E-X2MY2 2M
M12
Pre-wired Models
(2 m) PVC (oil-resistant) NO --- --- E2E-X5MY1 2M *1*2
NC E2E-X5MY2 2M
M12 Connector
Models --- NO (3, 4): (AC, AC) E, F E2E-X5MY1 2M
NC (1, 2): (AC, AC) F E2E-X5MY2-M1
M18
Pre-wired Models
(2 m) PVC (oil-resistant) NO --- --- E2E-X10MY1 2M *1
NC E2E-X10MY2 2M
M12 Connector
Models --- NO (3, 4): (AC, AC) E, F E2E-X10MY1-M1
NC (1, 2): (AC, AC) F E2E-X10MY2-M1
M30
Pre-wired Models
(2 m) PVC (oil-resistant) NO --- --- E2E-X18MY1 2M *1
NC E2E-X18MY2 2M
M12 Connector
Models --- NO (3, 4): (AC, AC) E, F E2E-X18MY1-M1
NC (1, 2): (AC, AC) F E2E-X18MY2-M1
2 mm
5 mm
10 mm
18 mm
Appear-
ance Sensing distance Connection
method
Cable
specifications
Operation
mode
Pin
arrangement
Applicable con-
nector code *3Model
M12 Pre-wired Models
(2 m)
PVC (oil-resis-
tant)
NO
--- --- E2E-X3T1 2M
M18 Pre-wired Models
(2 m)
PVC (oil-resis-
tant) --- --- E2E-X7T1 2M *
M30 Pre-wired Models
(2 m)
PVC (oil-resis-
tant) --- --- E2E-X10T1 2M
3 mm
7 mm
10 mm
E2E
11
Shielded DC 3-Wire Models [Refer to Dimensions on page 30.]
*1. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X2E1 5M)
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X5E1-R 2M).
*3. Models with different frequencies are also available. The model number is E2E-X@@@5 (example: E2E-X5E15 2M).
*4. Models with pre-wired e-CON connectors are also available (cable length: 0.3 m). Add "-ECON 0.3M" to the end of the model number. (Example: E2E-X2E1-ECON
0.3M)
*5. Refer to page 24 for details.
3-Wire Models
Appear-
ance Sensing distance Connection
method
Cable
specifica-
tions
Opera-
tion
mode
Pin
arrangement
Appli-
cable
connec-
tor code
*5
Model
NPN output PNP output
3 dia. Pre-wired Models
(2 m)
PVC (oil-re-
sistant)
NO --- --- E2E-CR6C1 2M E2E-CR6B1 2M
NC E2E-CR6C2 2M E2E-CR6B2 2M
4 dia. Pre-wired Models
(2 m)
PVC (oil-re-
sistant)
NO --- --- E2E-CR8C1 2M *1*2 E2E-CR8B1 2M *2
NC E2E-CR8C2 2M E2E-CR8B2 2M
M5 Pre-wired Models
(2 m)
PVC (oil-re-
sistant)
NO --- --- E2E-X1C1 2M *1*2 E2E-X1B1 2M *2
NC E2E-X1C2 2M E2E-X1B2 2M
5.4 dia. Pre-wired Models
(2 m)
PVC (oil-re-
sistant)
NO --- --- E2E-C1C1 2M *1*2 E2E-C1B1 2M
NC E2E-C1C2 2M E2E-C1B2 2M
M8
Pre-wired Models
(2 m)
PVC (oil-re-
sistant) NO
--- ---
E2E-X1R5E1 2M *1*2 E2E-X1R5F1 2M *1*2
PVC (oil-re-
sistant) NC E2E-X1R5E2 2M E2E-X1R5F2 2M
M12 Connector
Models ---
NO 1: +V, 3: 0 V,
4: Control output B, D E2E-X1R5E1-M1 E2E-X1R5F1-M1
NC 1: +V, 3: 0 V,
2: Control output DE2E-X1R5E2-M1 E2E-X1R5F2-M1
M8 Connector
Models ---
NO 1: +V, 3: 0 V,
4: Control output GE2E-X1R5E1-M3 E2E-X1R5F1-M3
NC 1: +V, 3: 0 V,
2: Control output GE2E-X1R5E2-M3 E2E-X1R5F2-M3
M12
Pre-wired Models
(2 m)
PVC (oil-re-
sistant)
NO --- ---
E2E-X2E1 2M
*1*2*3*4E2E-X2F1 2M *1*2*3
NC E2E-X2E2 2M E2E-X2F2 2M
M12 Connector
Models ---
NO 1: +V, 3: 0 V,
4: Control output B, D E2E-X2E1-M1 E2E-X2F1-M1
NC 1: +V, 3: 0 V,
2: Control output DE2E-X2E2-M1 E2E-X2F2-M1
M18
Pre-wired Models
(2 m)
PVC (oil-re-
sistant)
NO --- ---
E2E-X5E1 2M
*1*2*3*4E2E-X5F1 2M *1*2*3
NC E2E-X5E2 2M E2E-X5F2 2M
M12 Connector
Models ---
NO 1: +V, 3: 0 V,
4: Control output B, D E2E-X5E1-M1 E2E-X5F1-M1
NC 1: +V, 3: 0 V,
2: Control output DE2E-X5E2-M1 E2E-X5F2-M1
M30
Pre-wired Models
(2 m)
PVC (oil-re-
sistant)
NO --- ---
E2E-X10E1 2M
*1*2*3*4E2E-X10F1 2M *2
NC E2E-X10E2 2M E2E-X10F2 2M
M12 Connector
Models ---
NO 1: +V, 3: 0 V,
4: Control output B, D E2E-X10E1-M1 E2E-X10F1-M1
NC 1: +V, 3: 0 V,
2: Control output DE2E-X10E2-M1 E2E-X10F2-M1
0.6 mm
0.8 mm
1 mm
1 mm
1.5 mm
2 mm
5 mm
10 mm
12
E2E
Unshielded DC 3-Wire Models [Refer to Dimensions on page 30.]
*1. The standard stock includes models with a cable length of 5 m. Specify the cable length at the end of the model number. (Example: E2E-X5ME1 5M)
*2. Models with a flexible cable are also available. Add -R to the end of the model number. (example: E2E-X5E1-R 2M).
*3. Models with different frequencies are also available. The model number is E2E-X@M@@5 (example: E2E-X5ME15 2M).
*4. Models with pre-wired e-CON connectors are also available (cable length: 0.3 m). Add "-ECON 0.3M" to the end of the model number. (Example: E2E-X2E1-ECON
0.3M)
*5. Refer to page 24 for details.
3-Wire Models
Appear-
ance Sensing distance Connection
method
Cable
specifications
Opera-
tion
mode
Pin
arrangement
Appli-
cable
connec-
tor code
*5
Model
NPN output PNP output
M8
Pre-wired Models
(2 m)
PVC (oil-resis-
tant)
NO --- --- E2E-X2ME1 2M *2 E2E-X2MF1 2M *2
NC E2E-X2ME2 2M E2E-X2MF2 2M
M12 Connector
Models ---
NO 1: +V, 3: 0 V,
4: Control output B, D E2E-X2ME1-M1 E2E-X2MF1-M1
NC 1: +V, 3: 0 V,
2: Control output DE2E-X2ME2-M1 E2E-X2MF2-M1
M8 Connector
Models ---
NO 1: +V, 3: 0 V,
4: Control output GE2E-X2ME1-M3 E2E-X2MF1-M3
NC 1: +V, 3: 0 V,
2: Control output GE2E-X2ME2-M3 E2E-X2MF2-M3
M12
Pre-wired Models
(2 m)
PVC (oil-resis-
tant)
NO --- --- E2E-X5ME1 2M
*1*2*3*4E2E-X5MF1 2M *2
NC E2E-X5ME2 2M E2E-X5MF2 2M
M12 Connector
Models ---
NO 1: +V, 3: 0 V,
4: Control output B, D E2E-X5ME1-M1 E2E-X5MF1-M1
NC 1: +V, 3: 0 V,
2: Control output DE2E-X5ME2-M1 E2E-X5MF2-M1
M18
Pre-wired Models
(2 m)
PVC (oil-resis-
tant)
NO --- --- E2E-X10ME1 2M
*1*2*3*4E2E-X10MF1 2M *2
NC E2E-X10ME2 2M E2E-X10MF2 2M
M12 Connector
Models ---
NO 1: +V, 3: 0 V,
4: Control output B, D E2E-X10ME1-M1 E2E-X10MF1-M1
NC 1: +V, 3: 0 V,
2: Control output DE2E-X10ME2-M1 E2E-X10MF2-M1
M30
Pre-wired Models
(2 m)
PVC (oil-resis-
tant)
NO --- --- E2E-X18ME1 2M
*1*2*3*4E2E-X18MF1 2M *2
NC E2E-X18ME2 2M E2E-X18MF2 2M
M12 Connector
Models ---
NO 1: +V, 3: 0 V,
4: Control output B, D E2E-X18ME1-M1 E2E-X18MF1-M1
NC 1: +V, 3: 0 V,
2: Control output DE2E-X18ME2-M1 E2E-X18MF2-M1
2 mm
5 mm
10 mm
18 mm
E2E
13
Ratings and Specifications
E2E-X@D@ DC 2-Wire Models
*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 29 for
details.)
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E-X2D@E2E-X4MD@E2E-X3D@E2E-X8MD@E2E-X7D@E2E-X14MD@E2E-X10D@E2E-X20MD@
Sensing distance 2 mm ±10% 4 mm ±10% 3 mm ±10% 8 mm ±10% 7 mm ±10% 14 mm ±10% 10 mm ±10% 20 mm ±10%
Set distance *10 to 1.6 mm 0 to 3.2 mm 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm
Differential travel 15% max. of sensing distance 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.
Standard sensing
object
Iron,
8 × 8 × 1mm
Iron,
20 × 20 × 1 mm
Iron,
12 × 12 × 1 mm
Iron,
30 × 30 × 1 mm
Iron,
18 × 18 × 1 mm Iron, 30 × 30 × 1 mm Iron,
54 × 54 × 1 mm
Response frequency
*21.5 kHz 1 kHz 0.8 kHz 0.5 kHz 0.4 kHz 0.1 kHz
Power supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Control
output
Load
current 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models
Residual
voltage
*3
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)
Indicators D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red)
Operation mode
(with sensing object
approaching)
D1 Models: NO
D2 Models: NC
Diagnostic output
delay 0.3 to 1 s
Protection circuits Surge suppressor, Load short-circuit protection (for control and diagnostic output)
Ambient
temperature range Operating: 25 to 70°C, Storage: 40 to 85°C (with no icing or condensation)
Ambient
humidity range Operating/storage: 35% to 95% (with no condensation)
Temperature
influence
±15% max. of sensing distance
at 23°C in the temperature range
of 25 to 70°C
±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2
10 times each in X, Y, and
Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)
Weight
(pack-
ed
state)
Pre-wired
Models Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g
Pre-wired
Connector
Models
--- Approx. 40 g Approx. 70 g Approx. 110 g
Connector
Models Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
Materi-
als
Case Stainless steel (SUS303) Nickel-plated brass
Sensing sur-
face PBT
Clamping
nuts Nickel-plated brass
Toothed
washer Zinc-plated iron
Accessories Instruction manual
Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.
14
E2E
E2E-X@Y@ AC 2-Wire Models
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least 25°C.
*2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of
5 to 200 mA max.
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E-X1R5Y@E2E-X2MY@E2E-X2Y@E2E-X5MY@E2E-X5Y@E2E-X10MY@E2E-X10Y@E2E-X18MY@
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 19.)
Standard sensing
object
Iron,
8 × 8 × 1mm Iron, 12 × 12 × 1 mm Iron,
15 × 15 × 1 mm
Iron,
18 × 18 × 1 mm Iron, 30 × 30 × 1 mm Iron,
54 × 54 × 1 mm
Response frequency 25 Hz
Power supply voltage
(operating voltage
range)*124 to 240 VAC (20 to 264 VAC), 50/60 Hz
Leakage current 1.7 mA max.
Control
output
Load
current *25 to 100 mA 5 to 200 mA 5 to 300 mA
Residual
voltage Refer to Engineering Data on page 20.
Indicators Operation indicator (red)
Operation mode
(with sensing object
approaching)
Y1 Models: NO
Y2 Models: NC
Protection circuits Surge suppressor
Ambient temperature
range *1*2
Operating/Storage: 25 to 70°C
(with no icing or condensation) Operating/Storage: 40 to 85°C (with no icing or condensation)
Ambient
humidity range Operating/storage: 35% to 95% (with no condensation)
Temperature
influence
±10% max. of sensing distance
at 23°C in the temperature range
of 25 to 70°C
±15% max. of sensing distance at 23°C in the temperature range of 40 to 85°C,
±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2
10 times each in X, Y, and
Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection Pre-wired Models: IEC 60529 IP67, in-house standards: oil-resistant
Connector Models: IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
Pre-
wired
Models
Model
Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g
Connec-
tor
Models
Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
Materials
Case Stainless steel (SUS303) Nickel-plated brass
Sensing
surface PBT
Clamp-
ing nuts Nickel-plated brass
Toothed
washer Zinc-plated iron
Accessories Instruction manual
Refer to the timing charts under I/O Circuit Diagrams on page 23 for details.
E2E
15
E2E-X@T1 AC/DC 2-Wire Models
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. Power Supply Voltage Waveform:
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
Size M12 M18 M30
Shielded Shielded
Item Model E2E-X3T1 E2E-X7T1 E2E-X10T1
Sensing distance 3 mm ±10% 7 mm ±10% 10 mm ±10%
Set distance 0 to 2.4 mm 0 to 5.6 mm 0 to 8 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 18.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response
frequency *1
DC 1 kHz 0.5 kHz 0.4 kHz
AC 25 Hz
Power supply voltage
(operating voltage range) *2
24 to 240 VDC (20 to 264 VDC)
48 to 240 VAC (40 to 264 VAC)
Leakage current DC: 1 mA max.
AC: 2 mA max.
Control
output
Load
current 5 to 100 mA
Residual
voltage
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)
AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)
Indicators Operation indicator (red), Setting indicator (green)
Operation mode
(with sensing object
approaching)
NO (Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.)
Protection circuits Load short-circuit protection (20 to 40 VDC only), Surge suppressor
Ambient temperature range Operating: 25 to 70°C, Storage: 40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 80 g Approx. 140 g Approx. 190 g
Materials
Case Nickel-plated brass
Sensing
surface PBT
Clamping
nuts Nickel-plated brass
Toothed
washer Zinc-plated iron
Accessories Instruction manual
16
E2E
E2E-X@E@/F@ DC 3-Wire Models
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. When using an M8 Model at an ambient temperature between 70 and 85°C, supply 10 to 30 VDC to the Sensor and make sure that the Sensor has a control output
of 100 mA maximum.
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E
-X1R5E@/F@
E2E
-X2ME@/F@
E2E
-X2E@/F@
E2E
-X5ME@/F@
E2E
-X5E@/F@
E2E
-X10ME@/F@
E2E-X10E@/
F@
E2E
-X18ME@/F@
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.)
Standard sensing
object
Iron,
8 × 8 × 1mm Iron, 12 × 12 × 1 mm Iron,
15 ×15 × 1mm
Iron,
18 × 18 × 1 mm Iron, 30 × 30 × 1 mm Iron,
54 × 54 × 1 mm
Response frequency
*12 kHz 0.8 kHz 1.5 kHz 0.4 kHz 0.6 kHz 0.2 kHz 0.4 kHz 0.1 kHz
Power supply voltage
(operating voltage
range) *2
12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max.
Current consumption 13 mA max.
Control
output
Load
current *2200 mA max.
Residual
voltage 2 V max. (Load current: 200 mA, Cable length: 2 m)
Indicators Operation indicator (red)
Operation mode
(with sensing object
approaching)
E1/F1 Models: NO
E2/F2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 21 for details.
Protection circuits Load short-circuit protection, Surge suppressor, Reverse polarity protection
Ambient
temperature range *2Operating/Storage: 40 to 85°C (with no icing or condensation)
Ambient humidity
range Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
±15% max. of sensing distance at 23°C in the temperature range of 40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2
10 times each in X, Y, and
Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection Pre-wired Models : IEC 60529 IP67, in-house standards: oil-resistant
Connector Models : IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
Pre-
wired
Models
Approx. 65 g Approx. 75 g Approx. 150 g Approx. 195 g
Connec-
tor
Models
Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
Materials
Case Stainless steel (SUS303) Nickel-plated brass
Sensing
surface PBT
Clamp-
ing nuts Nickel-plated brass
Toothed
washer Zinc-plated iron
Accessories Instruction manual
E2E
17
E2E-C@C/B@ and E2E-X1C/B@ DC 3-Wire Models
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
Size 3 dia. 4 dia. M5 5.4 dia.
Shielded Shielded
Item Model E2E-CR6C/B@E2E-CR8C/B@E2E-X1C/B@E2E-C1C/B@
Sensing distance 0.6 mm ±15% 0.8 mm ±15% 1 mm ±15%
Set distance 0 to 0.4 mm 0 to 0.5 mm 0 to 0.7 mm
Differential travel 15% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 18 and 19.)
Standard sensing ob-
ject Iron, 3 × 3 × 1 mm Iron, 5 × 5 × 1 mm
Response frequency *2 kHz 3 kHz
Power supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 10 mA max. 17 mA max.
Control
output
Load
current
Open-collector output,
80 mA max. (30 VDC max.) Open-collector output, 100 mA max. (30 VDC max.)
Residual
voltage
1 V max.
(Load current: 80 mA,
Cable length: 2 m)
2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators Operation indicator (red)
Operation mode
(with sensing object
approaching)
C1/B1 Models: NO
C2 Models: NC
Protection circuits Reverse polarity protection, Surge suppressor
Ambient
temperature range Operating/Storage: 25 to 70°C (with no icing or condensation)
Ambient humidity
range Operating/Storage: 35% to 95% (with no condensation)
Temperature influ-
ence ±15% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence
±5% max. of sensing distance at
rated voltage in the rated voltage
±10% range
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP66 IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 60 g
Materials
Case Stainless steel (SUS303) Nickel-plated brass
Sensing
surface Heat-resistant ABS
Clamping
nuts Nickel-plated brass (E2E-X1C/B@ only)
Toothed
washer Zinc-plated iron (E2E-X1C/B@ only)
Accessories Instruction manual
Refer to the timing charts under I/O Circuit Diagrams on page 22 for details.
18
E2E
Engineering Data (Typical)
Sensing Area
Shielded Models E2E-C@C@/-X@C@
E2E-C@B1/-X@B@
E2E-X@D@/-X@T1 E2E-X@E@/-X@Y@/-X@F@
Unshielded Models
E2E-X@MD@E2E-X@ME@/-X@MY@/-X@MF@
Influence of Sensing Object Size and Material
E2E-X2D@E2E-X3D@/-X3T1 E2E-X7D@/-X7T1
E2E-X10D@/-X10T1 E2E-X4MD@E2E-X8MD@
X
Y
E2E-X10
E2E-X7
E2E-X3
E2E-X2
20 15 10 5 0 5 10 15
12
10
8
6
4
2
0
Distance Y (mm)
Distance X (mm)
E2E-X10
E2E
-X1R5
E2E-X5
E2E-X2
X
Y
15 10 5 0 5 10
12
10
8
6
4
2
0
Distance Y (mm)
Distance X (mm)
E2E-X1/E2E-C1
E2E-CR8
E2E-CR6
X
Y
3.0 2.0 1.0 0 1.0 2.0
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
Distance Y (mm)
Distance X (mm)
X
Y
E2E
-X20M
E2E
-X14M
E2E
-X8M
E2E
-X4M
30 20 10 0 10 20
30
25
20
15
10
5
0
Distance Y (mm)
Distance X (mm)
E2E-X18M
E2E-X10M
E2E-X5M
E2E-X2M
X
Y
30 20 10 0 10 20
30
25
20
15
10
5
0
Distance Y (mm)
Distance X (mm)
0 5 10 15 20 25
3.0
2.5
2.0
1.5
1.0
0.5
X
d ×
d t = 1 mm
Side len
g
th of sensin
g
ob
j
ect: d
(
mm
)
Iron
Stainless
steel
(SUS304)
Brass
Aluminum
Copper
Distance X (mm)
0 5 10 15 20 25 30 35 40
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Iron
Stainless
steel
(SUS304)
Brass
Aluminum
Copper
Distance X (mm)
0 10 20 30 40 50
8
7
6
5
4
3
2
1
X
d ×
d
t = 1 mm
Side len
g
th of sensin
g
ob
j
ect: d
(
mm
)
Iron
Stainless
steel
(SUS304)
Brass
Aluminum
Copper
Distance X (mm)
0 10 20 30 40 50 60 70
12
10
8
6
4
2
X
d ×
d t = 1 mm
Side len
g
th of sensin
g
ob
j
ect: d
(
mm
)
Iron
Stainless
steel
(SUS304)
Brass
Aluminum
Copper
Distance X (mm)
0 10 20 30 40 50 60 70
6
5
4
3
2
1
X
d ×
d
t = 1 mm
Brass
Copper
Side length of sensing object: d (mm)
Iron
Stainless
steel
(SUS304)
Aluminum
Distance X (mm)
0 10 15 20 30 40 50 60 70
12
10
8
6
4
2
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Iron
Stainless
steel
(SUS304)
Brass
Aluminum
Copper
Distance X (mm)
E2E
19
E2E-X14MD@E2E-X20MD@E2E-X1R5E@/-X1R5Y@/-X1R5F@
E2E-X2E@/-X2Y@/-X2F@E2E-X5E@/-X5Y@/-X5F@E2E-X10E@/-X10Y@/-X10F@
E2E-X2ME@/-X2MY@/-X2MF@E2E-X5ME@/-X5MY@/-X5MF@E2E-X10ME@/-X10MY@/-X10MF@
E2E-X18ME@/-X18MY@/-X18MF@E2E-CR6@E2E-CR8@
0 10 20 30 40 50 60 70
25
20
15
10
5
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Iron
Stainless
steel
(SUS304)
Brass
Aluminum
Copper
Distance X (mm)
0 10 20 30 40 50 60 70 80 90 100
25
20
15
10
5
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Iron
Stainless
steel
(SUS304)
Brass
Aluminum
Copper
Distance X (mm)
0 5 10 15 20 25
2.5
2.0
1.5
1.0
0.5
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Iron
Stainless steel
(SUS304)
Brass
Aluminum
Distance X (mm)
0 5 10 15 20 25
2.5
2.0
1.5
1.0
0.5
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Iron
Stainless steel
(SUS304)
Brass
Aluminum
Distance X (mm)
0 10 20 30 40 50
7
6
5
4
3
2
1
X
d ×
d t = 1 mm
Side length of sensing object: d (mm
)
Stainless steel
(SUS304)
Iron
Brass
Aluminum
Distance X (mm)
0 10 20 30 40 50 60
12
10
8
6
4
2
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Stainless steel (SUS304)
Iron
Brass
Aluminum
Distance X (mm)
0 5 10 15 20 25 30
2.5
2.0
1.5
1.0
0.5
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Iron
Stainless steel
(SUS304)
Brass
Aluminum
Copper
Distance X (mm)
0 10 20 30 40 50
7
6
5
4
3
2
1
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Stainless steel
(SUS304)
Iron
Brass
Aluminum
Distance X (mm)
0 10 20 30 40 50 60
12
10
8
6
4
2
X
Side length of sensing object: d (mm)
Stainless steel (SUS304)
Iron
Brass
Aluminum
d ×
d t = 1 mm
Distance X (mm)
0 20 40 60 80 100
25
20
15
10
5
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Stainless steel (SUS304)
Iron
Brass
Aluminum
Distance X (mm)
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0 5 10 15 20
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Stainless steel (SUS304)
Iron
Brass
Aluminum
Distance X (mm)
0 5 10 15 20 25 30
1.2
1.0
0.8
0.6
0.4
0.2
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Stainless steel (SUS304)
Iron
Brass
Aluminum
Copper
Distance X (mm)
20
E2E
E2E-X1@/-C1@
Leakage Current
E2E-X@D@E2E-X@Y@E2E-X@T1
Residual Output Voltage
E2E-X@D@E2E-X@T1
E2E-X@Y@ at 24 VAC E2E-X@Y@ at 100 VAC E2E-X@Y@ at 200 VAC
0 5 10 15 20 25
1.2
1.0
0.8
0.6
0.4
0.2
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Stainless steel
(SUS304)
Iron
Brass
Aluminum
Distance X (mm)
0 5 10 15 20 25 30
1.0
0.8
0.6
0.4
0.2
E2E-X2D1-N
E2E-X7D1-N
E2E-X3D1-N
E2E-X10D1-N
Power supply voltage (V)
Leakage current (mA)
V
0 50 100 150 200 250 300
1.4
1.2
1.0
0.8
0.6
0.4
0.2
~
mA
~
Power supply voltage (V)
AC
power
Protective
resistance
Proximity
Sensor (OFF)
Leakage current (mA)
0 50 100 150 200 250 300
1.4
1.2
1.0
0.8
0.6
0.4
0.2
Power supply voltage (V)
AC power
DC power
Leakage current (mA)
5
4
3
2
1
01 3 5 10 30 50 100
E2E-X@D@
E2E-X@D1-M1J-T
Load current (mA)
Residual output voltage (V)
6
5
4
3
2
1 3 5 10 30 50 100
24 VDC
100 VAC
200 VAC
Load current (mA)
Residual output voltage (V)
V
30
25
20
15
10
5
01 3 5 10 30 50 100 300 500
V
L
~
~
A24 VAC
OFF
ON
Load voltage VL (V)
Load current (mA)
Residual load
voltage
Residual output voltage V
120
100
80
60
40
20
01 3 5 10 30 50 100 300 500
100 VAC
V
L
~
~
A
OFF
ON
Load current (mA)
Residual output voltage
Residual load
voltage
Load voltage VL (V)
V
200 VAC
V
L
~
A
240
200
160
120
80
40
0
~
ON
1 3 5 10 30 50 100 300
500
OFF
Load current (mA)
Residual output voltage
Residual
load voltage
Load voltage VL (V)
E2E
21
I/O Circuit Diagrams
E2E-X@D@ DC 2-Wire Models
Operation
mode Model Timing Chart Output circuit
Without
self-
diagnostic
output:
NO
E2E-X@D1-N
E2E-X@D1-M1G(J)
E2E-X@D1-(M1TGJ)-U
E2E-X@D1-M3G
E2E-X@D1-M1J-T
Without
self-
diagnostic
output:
NC
E2E-X@D2-N
E2E-X@D2-M1G
E2E-X@D2-(M1TGJ)-U
E2E-X@D2-M3G
With self-
diagnostic
output:
NO
E2E-X@D1S
E2E-X@D1S-M1
(%) 80 0100
Sensing
object
Rated
sensing
distance
Stable sensing area
Non-sensing
area
Unstable
sensing
area
Set position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
Setting indicator
(green)
Operation
indicator (red)
Control output
0 V
+V
4
1
Load
Brown
Blue
Polarity: Yes
Note: The load can be connected to either the
+V or 0 V side.
Prox-
imity
Sensor
main
circuit
0 V
(+V)
+V
(0 V)
3
4
Load
Prox-
imity
Sensor
main
circuit
Polarity: None
Note 1. The load can be connected to either the +V or
0 V side.
2. The E2E-X@D1-M1J-T has no polarity.
Therefore, terminals 3 and 4 have no polarity.
0
(%) 100
Sensing
object
Rated
sensing
distance
Sensing area
Non-sensing
area
Proximity Sensor
ON
OFF
ON
OFF
Operation
indicator (red)
Control output
0 V
+V
2
1
Load
Brown
Blue
Note: The load can be connected to either the +V
or 0 V side.
Prox-
imity
Sensor
main
circuit
(%) 80 0100
Sensing
object
Rated
sensing
distance
Stable sensing area
Non-sensing
area
Unstable
sensing
area
Set position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Setting indicator
(green)
Operation
indicator (red)
Control output
Diagnostic output*
* The diagnostic output is ON when there is a coil
burnout or the sensing object is located in the
unstable sensing area for 0.3 s or longer.
+V
+V
0
Load
Load
Brown (4)
Orange (2)
(diagnostic
output)
Blue (3)
Note: Connect both the loads to the +V side of
the control output and diagnostic output.
Prox-
imity
Sensor
main
circuit
22
E2E
DC 3-Wire Models
Operation
mode
Output
specifica-
tions
Model Timing Chart Output circuit
NO
NPN output
E2E-X@E@
E2E-X@E@-M1
E2E-X@E@-M3
NC
NO
PNP output
E2E-X@F@
E2E-X@F@-M1
E2E-X@F@-M3
NC
NO
NPN open-
collector
output
E2E-C/X@C@
NC
NO
PNP open-
collector
output
E2E-C/X@B@
NC
Present
Not present
ON
OFF
ON
OFF
High
Low
Operation
indicator (red)
Sensing
object
Control output
(between brown
and black leads)
Output voltage
(between black
and blue leads)
+V
Tr
0 V
100
3
4
1
Load
Brown
Black
*Constant current output is 1.5 to 3 mA.
Blue
Constant
current*
Proximity
Sensor
main
circuit
Note: For Connector Models, the
connection between pins 1, 4 and 3
uses an NO contact, and the
connection between pins 1, 2 and 3
uses an NC contact.
2
Present
Not present
ON
OFF
ON
OFF
High
Low
Operation indicator
(red)
Sensing object
Control output
(between brown and
black leads)
Output voltage
(between black and
blue leads)
Present
Not present
ON
OFF
ON
OFF
High
Low
Operation indicator
(red)
Sensing object
Control output
(Between blue and
black leads)
Output voltage
(between brown
and black leads)
100
Tr
+V
*
Load
Brown
Black
*When a transistor is connected
Blue
Proximity
Sensor
main
circuit
Note: For Connector Models, the
connection between pins 1, 4 and 3
uses an NO contact, and the
connection between pins 1, 2 and 3
uses an NC contact.
0 V
3
4
1
2
Present
Not present
ON
OFF
ON
OFF
High
Low
Operation indicator
(red)
Sensing object
Control output
(Between blue and
black leads)
Output voltage
(between brown
and black leads)
Present
Not present
ON
OFF
ON
OFF
Operation
indicator (red)
Sensing
object
Control output
+V
100 *
0 V
Load
Brown
Black
Blue
Proximity
Sensor
main
circuit
*The E2E-CR6@ does not have 100- resistance.
Present
Not present
ON
OFF
ON
OFF
Operation
indicator (red)
Sensing
object
Control
output
Present
Not present
ON
OFF
ON
OFF
Operation
indicator (red)
Sensing
object
Control output
0 V
+V
100 *
Load
Brown
Black
Blue
Proximity
Sensor
main
circuit
*The E2E-CR6@ does not have 100- resistance.
Present
Not present
ON
OFF
ON
OFF
Operation
indicator (red)
Sensing
object
Control output
E2E
23
AC 2-Wire Models
AC/DC 2-Wire Models
Operation
mode Model Timing Chart Output circuit
NO
E2E-X@Y@
E2E-X@Y@-M1
NC
Operation
mode Model Timing Chart Output circuit
NO E2E-X@T1
Present
Not present
ON
OFF
Operate
Reset
Operation
indicator (red)
Sensing
object
Control output
Load
Brown 3 (or 1)
Blue 4 (or 2)
Proximity
Sensor
main
circuit
Note: For Connector Models, the connection
between pins 3 and 4 uses an NO
contact, and the connection between
pins 1 and 2 uses an NC contact.
Present
Not present
ON
OFF
Operate
Reset
Operation
indicator (red)
Sensing
object
Control
output
80100 0
(%)
Sensing
object
Rated
sensing
distance
Stable sensing area
Non-sensing
area
Unstable
sensing
area
Set position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
Setting indicator
(green)
Operation
indicator (red)
Control output
24 to 240 VDC
48 to 240 VAC
Load
Brown
Blue
Proximity
Sensor
main
circuit
Power
supply
Note: The load can be connected to either the +V or
0 V side.
There is no need to be concerned about the
polarity (brown/blue) of the Proximity Sensor.
24
E2E
Sensor I/O Connectors
Connector Applicable
connector code
Connector model
number
Applicable Proximity Sensor
model number
Connection
diagram No. *1
Screw Appearance Cable
length
M12
2 m
AXS2F-D421-DA0-A E2E-X@D1-M1G 1
E2E-X@D1-M1GJ
BXS2F-D421-DC0-A E2E-X@D1-M1J-T 3
E2E-X@E1/F1-M1 9
CXS2F-D421-DD0 E2E-X@D1-M1 2
DXS2F-D421-D80-A
E2E-X@D2-M1 7
E2E-X@D2-M1(G) 6
E2E-X@D1S-M1 5
E2E-X@E@/F@-M1 10, 11
EXS2F-A421-DB0-A E2E-X@Y1-M1 14
FXS2F-A421-D90-A E2E-X@Y2-M1 15
5 m
AXS2F-D421-GA0-A E2E-X@D1-M1G 1
E2E-X@D1-M1GJ
BXS2F-D421-GC0-A E2E-X@D1-M1J-T 3
E2E-X@E1/F1-M1 9
CXS2F-D421-GD0 E2E-X@D1-M1 2
DXS2F-D421-G80-A
E2E-X@D2-M1 7
E2E-X@D2-M1(G) 6
E2E-X@D1S-M1 5
E2E-X@E@/F@-M1 10, 11
EXS2F-A421-GB0-A E2E-X@Y1-M1 14
FXS2F-A421-G90-A E2E-X@Y2-M1 15
2 m
AXS2F-D422-DA0-A E2E-X@D1-M1G 1
E2E-X@D1-M1GJ
BXS2F-D422-DC0-A E2E-X@D1-M1J-T 3
E2E-X@E1/F1-M1 9
CXS2F-D422-DD0 E2E-X@D1-M1 2
DXS2F-D422-D80-A
E2E-X@D2-M1 7
E2E-X@D2-M1(G) 6
E2E-X@D1S-M1 5
E2E-X@E@/F@-M1 10, 11
EXS2F-A422-DB0-A E2E-X@Y1-M1 14
5 m
AXS2F-D422-GA0-A E2E-X@D1-M1G 1
E2E-X@D1-M1GJ
BXS2F-D422-GC0-A E2E-X@D1-M1J-T 3
E2E-X@E1/F1-M1 9
CXS2F-D422-GD0 E2E-X@D1-M1 2
DXS2F-D422-G80-A
E2E-X@D2-M1 7
E2E-X@D2-M1(G) 6
E2E-X@D1S-M1 5
E2E-X@E@/F@-M1 10, 11
EXS2F-A422-GB0-A E2E-X@Y1-M1 14
2 m
H
XS5F-D421-D80-P
E2E-X@D@-M1TGJ-U 16, 17
5 m XS5F-D421-G80-P
Straight
L-shape
Smartclick Connector,
Straight
E2E
25
*1. Refer to Connection Diagrams on page 26 for information on Proximity Sensor and I/O Connector connections.
*2. Refer to Introduction to Sensor I/O Connectors for details and for information on Robotics Cables.
M8
*2
2 m
G
XS3F-M421-402-R
E2E-X@D1-M3G 4
E2E-X@D2-M3G 8
E2E-X@E@/F@-M3 12, 13
5 m XS3F-M421-405-R
E2E-X@D1-M3G 4
E2E-X@D2-M3G 8
E2E-X@E@/F@-M3 12, 13
2 m XS3F-M422-402-R
E2E-X@D1-M3G 4
E2E-X@D2-M3G 8
E2E-X@E@/F@-M3 12, 13
5 m XS3F-M422-405-R
E2E-X@D1-M3G 4
E2E-X@D2-M3G 8
E2E-X@E@/F@-M3 12, 13
Connector Applicable
connector code
Connector model
number
Applicable Proximity Sensor
model number
Connection
diagram No. *1
Screw Appearance Cable
length
Straight
L-shape
26
E2E
Connections for Sensor I/O Connectors
* Different from Proximity Sensor wire colors.
Connection
diagram No.
Proximity Sensor Sensor I/O Connector
model number Connections
Type Operation
mode Model
1DC 2-wire
(IEC pin wiring)
NO
E2E-X@D1-M1G(J)
2
DC 2-wire
(previous pin
wiring)
E2E-X@D1-M1
3DC 2-wire
(no polarity) E2E-X@D1-M1J-T
4DC 2-wire
(M8 connector) E2E-X@D1-M3G
5
DC 2-wire
(diagnostic
type)
E2E-X@D1S-M1
6DC 2-wire
(IEC pin wiring)
NC
E2E-X@D2-M1G
7
DC 2-wire
(previous pin
wiring)
E2E-X@D2-M1
8DC 2-wire
(M8 connector) E2E-X@D2-M3G
XS2F-D42@-@A0-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
4
3
2
1
4
3
2
1
XS2FE2E
Main
circuit
Brown (+)
Blue ()
XS2F-D42@-@D0
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
2
4
3
2
1
4
3
1
XS2FE2E
Blue ()
Brown (+)
Main
circuit
XS2F-D42@-@C0-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
*
XS2F
4
3
2
1
4
3
2
1
E2E
Brown (not connected)
Black () (+)
Main
circuit
Blue (+) ()
XS3F-M42@-40@-R
1: Straight
2: L-shape
2: 2-m cable
5: 5-m cable
*
XS3F
4
3
2
1
4
3
2
1
E2E
Brown (+)
White (not connected)
Blue (not connected)
Black ()
Main
circuit
XS2F-D42@-@80-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
*
XS2F
4
3
2
1
4
3
2
1
E2E
Brown (not connected)
White (diagnostic output) (+)
Blue (0 V)
Black (control output) (+)
Main
circuit
XS2F-D42@-@80-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
*
XS2F
4
3
2
1
4
3
2
1
E2E
White ()
Blue (not connected)
Brown (+)
Black (not connected)
Main
circuit
XS2F-D42@-@80-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
*
XS2F
4
3
2
1
4
3
2
1
E2E
White (+)
Blue ()
Brown (not connected)
Black (not connected)
Main
circuit
XS3F-M42@-40@-R
1: Straight
2: L-shape
2: 2-m cable
5: 5-m cable
*
XS3F
4
3
2
1
4
3
2
1
E2E
White ()
Blue (not connected)
Brown (+)
Black (not connected)
Main
circuit
E2E
27
* Different from Proximity Sensor wire colors.
Connection
diagram No.
Proximity Sensor Sensor I/O Connector
model number Connections
Type Operation
mode Model
9
DC 3-wire
NO
E2E-X@E/F1-M1
10 E2E-X@E1/F1-M1
11 NC E2E-X@E2/F2-M1
12
DC 3-wire
(M8 connector)
NO E2E-X@E1/F1-M3
13 NC E2E-X@E2/F2-M3
14
AC 2-wire
NO E2E-X@Y1-M1
15 NC E2E-X@Y2-M1
16
DC 2-wire
(Smartclick
connector)
NO E2E-X@D1-
M1TGJ-U
17
DC 2-wire
(Smartclick
connector)
NC E2E-X@D2-
M1TGJ-U
Refer to Introduction to Sensor I/O Connectors for details.
XS2F-D42@-@C0-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
XS2F
4
3
2
1
4
3
2
1
E2E
Brown (+V)
Blue (0 V)
Black (output)
Main
circuit
XS2F-D42@-@80-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
XS2F
4
3
2
1
4
3
2
1
E2E
Brown (+V)
White (output)
Blue (0 V)
Black (not connected)
Main
circuit
XS2F-D42@-@80-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
XS3F
4
3
2
1
4
3
2
1
E2E
Brown (+V)
White (not connected)
Blue (0 V)
Black (output)
Main
XS3F-M42@-40@-R
1: Straight
2: L-shape
2: 2-m cable
5: 5-m cable
XS3F
4
3
2
1
4
3
2
1
E2E
Brown (+V)
White (not connected)
Blue (0 V)
Black (output)
Main
circuit
XS3F-M42@-40@-R
1: Straight
2: L-shape
2: 2-m cable
5: 5-m cable
XS3F
4
3
2
1
4
3
2
1
E2E
Brown (+V)
White (output)
Blue (0 V)
Black (not connected)
Main
circuit
XS2F-A42@-@B0-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
XS2F
4
3
2
1
4
3
2
1
E2E
Brown
Blue
Main
circuit
XS2F-A421-@90-A
D: 2-m cable
G: 5-m cable
*
XS2F
4
3
2
1
4
3
2
1
E2E
Blue (not connected)
Black (not connected)
Brown
White
Main
circuit
XS5F-D421-@80-P
D: 2-m cable
G: 5-m cable
XS5F
4
3
2
1
4
3
2
1
E2E-X@-M1TGJ
Blue (not connected)
Black ()
Brown (+)
White (not connected)
Main
circuit
XS5F-D421-@80-P
D: 2-m cable
G: 5-m cable
XS5F
4
3
2
1
4
3
2
1
E2E-X@-M1TGJ
Blue (not connected)
Black (not connected)
Brown (+)
White ()
Main
circuit
28
E2E
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use this product under ambient conditions that exceed the
ratings.
Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that the
clearances given in the following table are maintained. Failure to
maintain these distances may cause deterioration in the performance
of the Sensor.
WARNING
CAUTION
Do not short the load. Explosion or burning may
result.
Do not supply power to the Sensor with no load,
otherwise Sensor may be damaged.
Applicable Models
E2E-CR6@
E2E-CR8@
E2E-X1@
E2E-C1@
Precautions for Correct Use
l
m
n
m
D
d dia.
l
Influence of Surrounding Metal (Unit: mm)
Model Item M8 M12 M18 M30
DC 2-Wire Models
E2E-X@D@
AC/DC 2-Wire Models
E2E-X@T1
Shielded
l0
d 8 12 18 30
D0
m 4.5 82040
n 12182745
Unshielded
l 12152230
d 24407090
D 12152230
m 8 20 40 70
n 24407090
DC 3-Wire Models
E2E-X@E@
E2E-X@F@
AC 2-Wire Models
E2E-X@Y@
Shielded
l0
d 8 12 18 30
D0
m 4.5 82040
n 12182745
Unshielded
l 6 15 22 30
d 24405590
D 6 15 22 30
m 8 20 40 70
n 24365490
Model Item 3 dia. 4 dia. M5 5.4 dia.
DC 3-Wire Models
E2E-X@C/B@
E2E-C@C/B@
Shielded
l0
d 3455.4
D0
m22.43
n6 8
Relationship between Sizes and
Models
Model Model
3 dia.
Shielded
E2E-CR6C/B
4 dia. E2E-CR8C@
E2E-CR8B@
M5 E2E-X1C@
E2E-X1B@
5.4
dia.
E2E-C1C@
E2E-C1B@
M8
Shielded
E2E-X2D@
E2E-X1R5E@
E2E-X1R5F@
E2E-X1R5Y@
Unshielded
E2E-X4MD@
E2E-X2ME@
E2E-X2MF@
E2E-X2MY@
M12
Shielded
E2E-X3D@
E2E-X2E@
E2E-X2F@
E2E-X2Y@
E2E-X3T1
Unshielded
E2E-X8MD@
E2E-X5ME@
E2E-X5MF@
E2E-X5MY@
M18
Shielded
E2E-X7D@
E2E-X5E@
E2E-X5F@
E2E-X5Y@
E2E-X7T1
Unshielded
E2E-X14MD@
E2E-X10ME@
E2E-X10MF@
E2E-X10MY@
M30
Shielded
E2E-X10D@
E2E-X10E@
E2E-X10F@
E2E-X10Y@
E2E-X10T1
Unshielded
E2E-X20MD@
E2E-X18ME@
E2E-X18MF@
E2E-X18MY@
E2E
29
Loads with Large Surge Currents (E2E-X@T@)
If a load with a large surge current is connected, such as a relay, lamp, or motor, the surge current may cause the load short-circuit protection
circuit to operate, resulting in operating errors.
Mounting
Tightening Force
Do not tighten the nut with excessive force.
A washer must be used with the nut.
Note: 1. The allowable tightening strength depends on the distance from the
edge of the head, as shown in the following table. (A is the distance
from the edge of the head. B includes the nut on the head side. If the
edge of the nut is in part A, the tightening torque for part A applies
instead.)
2. The following strengths assume washers are being used.
Refer to the following to mount the E2E-CR6, E2E-CR8 and E2E-C1
Unthreaded Cylindrical Models.
When using a set screw, tighten it to a torque of 0.2 N·m max.
(E2E-C1: 0.4 N·m max.)
Connecting a DC 2-Wire Proximity Sensor to a PLC (Programmable Controller)
Required Conditions
Connection to a PLC is possible if the specifications of the PLC and the Proximity Sensor satisfy the following
conditions. (The meanings of the symbols are given at the right.)
1. The ON voltage of the PLC and the residual voltage of the Proximity Sensor must satisfy the following.
VON VCC VR
2. The OFF current of the PLC and the leakage current of the Proximity Sensor must satisfy the following.
IOFF Ileak
(If the OFF current is not listed in the PLC’s input specifications, take it to be 1.3 mA.)
3. The ON current of the PLC and the control output of the Proximity Sensor must satisfy the following.
IOUT (min.) ION IOUT (max.)
The ON current of the PLC will vary, however, with the power supply voltage and the input impedance, as
shown in the following equation.
ION = (VCC VR VPC)/RIN
Example
In this example, the above conditions are checked when the PLC Unit is the C200H-ID212, the Proximity
Sensor is the E2E-X7D1-N, and the power supply voltage is 24 V.
1. VON (14.4 V) VCc (20.4 V) VR (3 V) = 17.4 V:OK
2. IOFF (1.3 mA) Ileak (0.8 mA): OK
3. ION = [VCC (20.4 V) VR (3 V) VPLC (4 V)]/RIN (3 k) = Approx. 4.5 mA
Therefore, IOUT (min.) (3 mA) ION (4.5 mA): OK
Connection is thus possible.
Mutual Inter
f
erence (Unit: mm)
Note: Values in parentheses apply to Sensors operating at different frequencies.
Model Item M8 M12 M18 M30
DC 2-Wire Models
E2E-X@D@
AC/DC 2-Wire Models
E2E-X@T1
Shielded A 20 30 (20) 50 (30) 100 (50)
B 15 20 (12) 35 (18) 70 (35)
Unshielded A 80 120 (60) 200 (100) 300 (100)
B 60 100 (50) 110 (60) 200 (100)
DC 3-Wire Models
E2E-X@E@/X@F@
AC 2-Wire Models
E2E-X@Y@
Shielded A 20 30 (20) 50 (30) 100 (50)
B 15 20 (12) 35 (18) 70 (35)
Unshielded A 80 120 (60) 200 (100) 300 (100)
B 60 100 (50) 110 (60) 200 (100)
Model Item 3 dia. 4 dia. M5 5.4 dia.
DC 3-Wire Models
E2E-X@C/B@
E2E-C@C/B@
Shielded A20
B15
Mutual Interference
When installing Sensors face-to-face or
side-by-side, ensure that the minimum
distances given in the following table are
maintained.
A
B
Model Part A Part B
Dimension Torque Torque
M5 1 N·m
M8 Shielded 9 9 N·m 12 N·m
Unshielded 3
M12 30 N·m
M18 70 N·m
M30 180 N·m
Part B Part A Part B Part A
Shielded Models Unshielded Models 8 to 21 mm
9 to 21 mm
E2E-CR8, E2E-C1
E2E-CR6
Dimpled end of
set screw (M3)
(No screws are provided
with the E2E-CR8 or
E2E-C1.)
VON:ON voltage of PLC (14.4 V)
ION: ON current of PLC (typically 7 mA)
IOFF: OFF current of PLC (1.3 mA)
RIN: Input impedance of PLC (3 k)
VPC: Internal residual voltage of PLC (4 V)
VR: Output residual voltage of Proximity Sensor
(3 V)
Ileak: Leakage current of Proximity Sensor
(0.8 mA)
IOUT Control output of Proximity Sensor (3 to
100 mA)
VCC: Power supply voltage (PLC: 20.4 to 26.4 V)
Values in parentheses apply to the following PLC
model and Proximity Sensor model.
PLC: C200H-ID212
Sensor: E2E-X7D1-N
30
E2E
Dimensions
Main Units
Model Number-Dimensions Drawing Number Lookup Table
Note 1. Two clamping nuts and one toothed washer are provided with M8 to M30 Models.
2. The model numbers of M8 to M30 Pre-wired Models are laser-marked on the milled section and cable section. This does not apply, however, to models that
end in -U.
Model DC 2-Wire Models DC 3-Wire Models AC 2-Wire Models AC/DC 2-Wire Models
Model Shielded Model No. Model No. Model No. Model No.
Pre-wired Models
Shielded
3 dia.
---
E2E-CR6@1
--- ---
4 dia. E2E-CR8@2
M5 E2E-X1@4
5.4 dia. E2E-C1@3
M8 E2E-X2D@5 E2E-X1R5E@/F@5 E2E-X1R5Y@7
M12 E2E-X3D@9 E2E-X2E@/F@9 E2E-X2Y@11 E2E-X3T1 13
M18 E2E-X7D@14 E2E-X5E@/F@14 E2E-X5Y@14 E2E-X7T1 14
M30 E2E-X10D@16 E2E-X10E@/F@16 E2E-X10Y@16 E2E-X10T1 16
Unshielded
M8 E2E-X4MD@6 E2E-X2ME@/F@6 E2E-X2MY@8
---
M12 E2E-X8MD@10 E2E-X5ME@/F@10 E2E-X5MY@12
M18 E2E-X14MD@15 E2E-X10ME@/F@15 E2E-X10MY@15
M30 E2E-X20MD@17 E2E-X18ME@/F@17 E2E-X18MY@17
Connector
Models
(M12)
Shielded
M8 E2E-X2D@-M1(G) 18 E2E-X1R5E/F@-M1 18 ---
---
M12 E2E-X3D@-M1(G) 20 E2E-X2E/F@-M1 20 E2E-X2Y@-M1 22
M18 E2E-X7D@-M1(G) 24 E2E-X5E/F@-M1 24 E2E-X5Y@-M1 24
M30 E2E-X10D@-M1(G) 26 E2E-X10E/F@-M1 26 E2E-X10Y@-M1 26
Unshielded
M8 E2E-X4MD@-M1(G) 19 E2E-X2ME/F@-M1 19 ---
---
M12 E2E-X8MD@-M1(G) 21 E2E-X5ME/F@-M1 21 E2E-X5MY@-M1 23
M18 E2E-X14MD@-M1(G) 25 E2E-X10ME/F@-M1 25 E2E-X10MY@-M1 25
M30 E2E-X20MD@-M1(G) 27 E2E-X18ME/F@-M1 27 E2E-X18MY@-M1 27
Connector
Models
(M8)
Shielded
M8
E2E-X2D@-M3G 28 E2E-X1R5E/F@-M3 28
--- ---
Unshielded E2E-X4MD@-M3G 29 E2E-X2ME/F@-M3 29
Pre-wired
Connector
Models
Shielded
M8 E2E-X2D@-M1(T)GJ(-U) 30
--- --- ---
M12 E2E-X3D@-M1(T)GJ(-U) 31
M18 E2E-X7D@-M1(T)GJ(-U) 33
M30 E2E-X10D@-M1(T)GJ(-U) 35
Unshielded
M12 E2E-X8MD1-M1(T)GJ 32
--- --- ---
M18 E2E-X14MD1-M1(T)GJ 34
M30 E2E-X20MD1-M1(T)GJ 36
Pre-wired
Connector
Models
(no polarity)
Shielded
M12 E2E-X3D1-M1J-T 31
--- --- ---
M18 E2E-X7D@-M1J-T 33
M30 E2E-X10D@-M1J-T 35
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Pre-wired Models (Shielded)
3 dia.
Operation indicator (red)
±0.1
*
17
27
*2.4-dia. (7/0.127 dia.) vinyl-insulated round cable with 3 conductors,
Standard length: 2 m
Diagram 1 E2E-CR6B@/CR6C@Diagram 3 E2E-C1B@/C1C@
17.5
25
5.4 dia.
*
Operation indicator (red)
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
0.15 mm2, Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
Diagram 2 E2E-CR8B@/CR8C@
17.5
25
4 dia.
*
Operation indicator (red)
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section:
0.15 mm2, Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
Mounting Hole Dimensions
F
Dimension 3 dia. 4 dia. 5.4 dia.
F (mm) 3.3 dia. 4.2 dia. 5.7 dia.
+0.3
0+0.5
0+0.5
0
E2E
31
Pre-wired Models
(Shielded)
F
Mounting Hole Dimensions
Dimension M5 M8 M12
F (mm) 5.5 dia. 8.5 dia. 12.5 dia.
+0.5
0+0.5
0+0.5
0
9.7 dia. 17.5
25
15
8
M5 × 0.5 4
*
Operation indicator (red)
Two clamping nuts
Two toothed washers
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.15 mm2, Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
Diagram 4 E2E-X1B@/X1C@Pre-wired Models (Unshielded)
30 7
8
26
3
M8 × 1
13
15 dia.
*1
Indicators *2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3
mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m
Models with Highly Oil-resistant Cables:
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
Diagram 5 E2E-X2D@
E2E-X1R5E@/F@
30 7
8
26
13 63
15 dia.
M8 × 1
6.1 dia.
*1
Indicators *2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3
mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27
mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27
mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
Diagram 6 E2E-X4MD@
E2E-X2ME@/F@
Diagram 7 E2E-X1R5Y@
15 dia.
3
13
36
8
7
40
M8 × 1
*
Toothed
washer
Two clamping nuts
Operation indicator (red)
4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.3 mm2, Insulator
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
Diagram 8 E2E-X2MY@
40 7
8
36
13 63
15 dia.
M8 × 1
6.1 dia.
*
Operation indicator (red)
Two clamping nuts
Toothed
washer
4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
38 9
10
33
17 4
21 dia.
*1
M12 × 1
Indicators * 2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
2
, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
2
, Insulator diameter: 1.3
mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
2
, Insulator diameter: 1.27
mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
2
, Insulator diameter: 1.27
mm), Standard length: 2 m
Models with Highly Oil-resistant Cables:
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
2
, Insulator
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the
diagnostic output.
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
15.6
5.9
4
3
2
15
1
Pre-wired e-CON Connector Models
Connector: Product code
37104-3163-000FL (Sumitomo 3M)
Diagram 9 E2E-X3D@
E2E-X2E@/F@
Diagram 10 E2E-X8MD@
E2E-X5ME@/F@
38 9
10
33
17 74
9 dia.
21 dia.
M12 × 1
*1
Indicators *2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3
mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27
mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.27
mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for the
diagnostic output.
*2. D1 Models: Operation indicator (red) and setting indicator (green), D2/E/F Models: Operation indicator (red)
15.6
5.9
4
3
2
15
1
Pre-wired e-CON Connector Models
Connector: Product code
37104-3163-000FL (Sumitomo 3M)
32
E2E
Diagram 11 E2E-X2Y@
43 9
10
38
17 4
21 dia.
M12 × 1
*
Operation indicator (red)
Two clamping nuts
Toothed
washer
4-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
Diagram 12 E2E-X5MY@
43 9
10
38
17 74
21 dia.
M12 × 1
9 dia.
*
Operation indicator (red)
Two clamping nuts
Toothed
washer
4-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
Mounting Hole Dimensions
Pre-wired Models (Shielded)
F
Dimension M8 M12 M18 M30
F (mm) 8.5 dia. 12.5 dia. 18.5 dia. 30.5 dia.
+0.5
0+0.5
0+0.5
0+0.5
0
60 9
10
55
17
21 dia.
4
M12 × 1
*1
Indicators *2
Two clamping nuts
Toothed
washer
*1 4-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
*2 Operation indicator (red), Setting indicator (green)
Diagram 13 E2E-X3T1 Pre-wired Models (Unshielded)
43 12
10
38
4
24
29 dia.
*1
M18 × 1
Indicators *2
Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
Models with Highly Oil-resistant Cables:
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.5
mm2, Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output and
up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
5.9
4
3
2
15
1
15.6
Pre-wired e-CON
Connector Models
Connector: Product code
37104-2206-000FL
(Sumitomo 3M)
Diagram 14 E2E-X7D@/E2E-X5E@/F@
E2E-X5Y@/E2E-X7T1
10
43 12
10
38
4
24
29 dia.
M18 × 1
14.8 dia.
*1
*1
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
Indicators *2
Two clamping nuts
Toothed washer
Diagram 15 E2E-X14MD@/E2E-X10ME@/F@
E2E-X10MY@
5.9
4
3
2
15
1
15.6
Pre-wired e-CON
Connector Models
Connector: Product code
37104-2206-000FL
(Sumitomo 3M)
E2E
33
48 12
10
43
5
36
42 dia.
M30 × 1.5
*1
Indicators *2
Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
Models with Highly Oil-resistant:
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section:
0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
Diagram 16 E2E-X10D
@/
E2E-X10E
@/
F
@
E2E-X10Y@/E2E-X10T1
5.9
4
3
2
15
1
15.6
Pre-wired e-CON
Connector Models
Connector: Product code
37104-2206-000FL
(Sumitomo 3M)
48 12
10
13
43
5
36
42 dia.
M30 × 1.5
26.8 dia.
*1
Indicators *2
Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D1/T Models: Operation indicator (red), Setting indicator (green)
D2/E/F/Y Models: Operation indicator (red)
Diagram 17 E2E-X20MD
@/
E2E-X18ME
@/
F
@
E2E-X18MY@
5.9
4
3
2
15
1
15.6
Pre-wired e-CON
Connector Models
Connector: Product code
37104-2206-000FL
(Sumitomo 3M)
M8 Connector Models
(Shielded)
M8 Connector Models
(Unshielded)
M8 × 1
39
31
8
26
13 3
15 dia.
M8 × 1Indicators*
Toothed washer
Two clamping nuts
* D Models: Operation indicator (red),
Setting indicator (green)
D2/E/F Models: Operation indicator (red)
Diagram 28 E2E-X2D@-M3G/E2E-X1R5E@-M3/X1RF@-M3
M8 × 1
39
31
8
26
13 63
15 dia.
M8 × 1
6.1 dia.
Indicators*
Toothed washer
Two clamping nuts
* D Models: Operation indicator (red),
Setting indicator (green)
D2/E/F Models: Operation indicator (red)
Diagram 29 E2E-X4MD@-M3G/E2E-X2ME@-M3/X2MF@-M3
M12 Connector Models
(Shielded)
M12 Connector Models
(Unshielded)
M12 × 1
43
30
8
26
13 3
15 dia.
M8 × 1Indicators*
Toothed washer
Two clamping nuts
* D1 Models: Operation indicator (red),
Setting indicator (green)
D2/E/F Models: Operation indicator (red)
Diagram 18 E2E-X2D@-M1(G)
E2E-X1R5E@-M1/E2E-X1R5F@-M1
M12 × 1
43
30
8
26
13 63
6.1 dia.
15 dia.
M8 × 1Indicators*
Two clamping nuts
Toothed washer
* D1 Models: Operation indicator (red),
Setting indicator (green)
D2/E/F Models: Operation indicator (red)
Diagram 19 E2E-X4MD@-M1(G)
E2E-X2ME@-M1/E2E-X2MF@-M1
34
E2E
M12 × 1
48
10
33
17 4
21 dia.
M12 × 1Indicators *
Toothed washer
Two clamping nuts
* D1 Models: Operation indicator (red),
Setting indicator (green)
D2/E/F Models: Operation indicator (red)
Diagram 20 E2E-X3D
@
-M1
(G)
E2E-X2E@-M1/E2E-X2F@-M1
M12 × 1
48
10
33
17 74
21 dia.
M12 × 1
9 dia.
Indicators*
Toothed washer
Two clamping nuts
* D1 Models: Operation indicator (red), Setting indicator (green)
D2/E/F Models: Operation indicator (red)
Diagram 21 E2E-X8MD@-M1(G)
E2E-X5ME@-M1/E2E-X5MF@-M1
M12 × 1
53
10
38
17 4
21 dia.
M12 × 1Operation indicator (red)
Toothed washer
Two clamping nuts
Diagram 22 E2E-X2Y@-M1
M12 × 1
53
10
38
17 74
21 dia.
M12 × 1
9 dia.
Operation indicator (red)
Toothed washer
Two clamping nuts
Diagram 23 E2E-X5MY@-M1
M12 × 1
53
10
38
24 4
29 dia.
M18 × 1
Indicators*
Two clamping nuts
Toothed washer
* D1 Models: Operation indicator (red), Setting indicator (green)
D2/E/Y Models: Operation indicator (red)
Diagram 24 E2E-X7D@-M1(G)/E2E-X5E@-M1/X5F@-M1
E2E-X5Y@-M1
M12 × 1
53
10
38
24 10 4
29 dia.
M18 × 1
14.8 dia.
Indicators*
Toothed washer
Two clamping nuts
* D1 Models: Operation indicator (red), Setting indicator (green)
D2/E/Y Models: Operation indicator (red)
Diagram 25 E2E-X14MD@-M1(G)/E2E-X10ME@-M1
X10MF@-M1
E2E-X10MY@-M1
58
10
43
36 5
42 dia.
M30 × 1.5
M12 × 1
Indicators*
Two clamping nuts
Toothed washer
* D1 Models: Operation indicator (red), Setting indicator (green)
D2/E/Y Models: Operation indicator (red)
Diagram 26 E2E-X10D@-M1(G)/E2E-X10E@-M1/X10F@-M1
E2E-X10Y@-M1
58
10
43
36 13 5
42 dia.
M30 × 1.5
26.8 dia.
M12 × 1
Indicators*
Two clamping nuts
Toothed washer
* D1 Models: Operation indicator (red), Setting indicator (green)
D2/E/Y Models: Operation indicator (red)
Diagram 27 E2E-X20MD@-M1(G)/E2E-X18ME@-M1/
X18MF@-M1
E2E-X18MY@-M1
Mounting Hole Dimensions
F
Dimensions M8 M12 M18 M30
F (mm) 8.5 dia. 12.5 dia. 18.5 dia. 30.5 dia.
+0.5
0+0.5
0+0.5
0+0.5
0
E2E
35
Pre-wired Connector Models (Unshielded)
Dimension M12 M18 M30
F (mm) 12.5 dia. 18.5 dia. 30.5 dia.
+0.5
0+0.5
0+0.5
0
Pre-wired
C
onnector Models
(S
hielded
)
Mounting Hole Dimensions
F
7
30
8
26
3
M8 × 1
*1
M12 × 1
Indicators *2
Toothed washer
Two clamping nuts *1. No U suffix: 4-dia. Vinyl-insulated round cable
U suffix: 4-dia. Polyurethane insulated round cable,
Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
15 dia.
13
Diagram 30 E2E-X2D@-M1TGJ-U *3
E2E-X2D1-M1TGJ
Diagram 31 E2E-X3D@-M1GJ
E2E-X3D1-M1J-T
E2E-X3D@-M1TGJ-U *3
E2E-X3D1-M1TGJ
9
38
10
33
4
M12 × 1
*1
M12 × 1
21 dia.
17
Indicators *2
Toothed washer
Two clamping nuts *1. No U suffix: 4-dia. Vinyl-insulated round cable
U suffix: 4-dia. Polyurethane insulated round cable,
Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
Diagram 33 E2E-X7D@-M1GJ
E2E-X7D@-M1J-T
E2E-X7D@-M1TGJ-U *3
E2E-X7D1-M1TGJ
12
43
*1
10
38
4
M18 × 1
M12 × 1
29 dia.
24
Indicators *2
Toothed washer
Two clamping nuts *1. No U suffix: 6-dia. Vinyl-insulated round cable
U suffix: 6-dia. Polyurethane insulated round cable,
Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
Diagram 35 E2E-X10D@-M1GJ
E2E-X10D@-M1J-T
E2E-X10D@-M1TGJ-U *3
E2E-X10D1-M1TGJ
12
48
10
43
36 5
42 dia.
M30 × 1.5
*1
M12 × 1
Indicators *2
Toothed washer
Two clamping nuts
*1. No U suffix: 6-dia. Vinyl-insulated round cable
U suffix: 6-dia. Polyurethane insulated round cable,
Standard length: 300 mm
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
*3. The connectors for M1TGJ models are XS5 Smartclick connectors.
Diagram 32 E2E-X8MD1-M1GJ
E2E-X8MD1-M1TGJ
9
38
10
33
17 74
9 dia.
21 dia.
M12 × 1
*1
M12 × 1
Indicators *2
Toothed washer
Two clamping nuts *1. 4-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
36
E2E
Dimensions for Proximity Sensors with Sensor I/O Connectors
Accessories (Order Separately)
Sensor I/O Connectors
Refer to Introduction to Sensor I/O Connectors for details.
Diagram 34 E2E-X14MD@-M1GJ
E2E-X14MD1-M1TGJ
12
43
10
38
24
10 4
29 dia.
M18 × 1
14.8 dia.
*1
M12 × 1
Indicators*2
Toothed washer
Two clamping nuts *1. 6-dia. vinyl-insulated round cable, Standard
length: 300 mm
*2. D1 Models: Operation indicator (red),
Setting indicator (green)
D2 Models: Operation indicator (red)
Diagram 36 E2E-X20MD1-M1GJ
E2E-X20MD1-M1TGJ
12
48
*1
10
43
36 13 5
26.8 dia.
42 dia.
M30 × 1.5
M12 × 1
Indicators*2
Toothed washer
Two clamping nuts *1. 6-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red),
Setting indicator (green)
L1
L2
L1
L2
Straight Connectors
L-shape Connectors
Straight Connectors
L-shape Connectors
Shielded Models Unshielded Models Dimensions with the X
S
2F
C
onnected (Unit: mm)
* The overall length of the Sensor is different between AC and DC
Models for Sensors with diameters of M12. This will change the
dimension when the I/O Connector is connected.
Dimensions with the XS3F Connected (Unit: mm)
Dimension
Sensor diameter L1 L2
M8 Approx. 75 Approx. 62
M12* DC Approx. 80 Approx. 67
AC Approx. 85 Approx. 72
M18 Approx. 85 Approx. 72
M30 Approx. 90 Approx. 77
Dimension
Sensor diameter L1 L2
M8 Approx. 65 Approx. 54
Mounting Brackets
Protective Covers
Sputter Protective Covers
Refer to Y92
@
for details.
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.