PRODUCT DATASHEET TC-HPK110-v1.1
www.frigodynamics.com
info@frigodynamics.com
Copyright © 2013 FrigoDynamics GmbH
All rights reserved
Value
Conditions
Thermal Resistance (Tc)
1.15 ⁰C/W 1, 2
Measured between LED Tc - ambient
Thermal Resistance (Hs)
0.95 C/W 1
Measured between LED mounting base and ambient
Design power
50W 3
Electrical Load
Storage Temperature
-40⁰C to 100⁰C
Air temperature surrounding the unit
Surface finish
Black
Anodized
Weight
310g & 300g
Complete unit: variation 1 & variation 2
Regulatory Compliance
RoHS
No further compliance necessary for passive devices
1 Thermal resistance is measured in free air without airflow obstructions and in a horizontal orientation.
2 This value is impacted by the thermal interface material used, especially with smaller heat sources.
3 Design power is based on 50 ⁰C temperature difference (ΔT) between maximum Tc point on LED module to ambient temperature.
Passive, no CO2 emissions
Light weight
Compact
Zero noise levels
No operating cost
No lifetime issues
Easy installation
The TC HPK-Fin™ solution is a 2-phase heat exchanger allowing high levels of
power dissipation with zero power consumption. This design trades the low
profile of the OC version for a shorter length. Ideal for recessed downlights
with constrained space in horizontal direction.
Please Note:
Registered German Utility Model
DBGM protected
PCT Patent Application pending
Specifications
PRODUCT DATASHEET TC-HPK110-v1.1
www.frigodynamics.com
info@frigodynamics.com
Copyright © 2013 FrigoDynamics GmbH
All rights reserved
Part Number
Description
Specifics
TC 0800 HPK01-110AN
Blank Surface
Variation 1
TC 0500 HPK01-110AN
Blank Surface
Variation 2
TC 0801 HPK01-110AN
Philips/Tridonic® mounting pattern
Variation 1 for Fortimo DLM/ STARK DLE
Variation 2 for XLM
Variation 2 for all BXRA, VERO™ 13, 18, 29
Variation 2 for Soleriq/SLM/SLE/WU-M
TC 0502 HPK01-110AN
Xicato mounting pattern
TC 0503 HPK01-110AN
Bridgelux® mounting pattern
TC 0505 HPK01-110AN
Philips/VS/Osram/Tridonic pattern
TC 0506 HPK01-110AN
Xicato® mounting pattern
Variation 2 for XSM™
TC 0508 HPK01-110AN
Citizen® mounting pattern
Variation 2 for CLL032, CLL042, CLL052
Design
Variation 1
Design
Variation 2
Design
Variation 1
Design
Variation 1
Please contact us, should you have specific requirements not covered in the data sheets.
3D envelope CAD file available upon request and
endorsement of FrigoDynamics NDA
Disclaimer
Information given by FrigoDynamics is believed to be accurate and reliable. However, since every potential application and the
environment our solutions operate in cannot be anticipated, FrigoDynamics does not guarantee suitability in all circumstances. Thermal
performance may vary depending on the enclosure, the operating orientation and natural airflow. FrigoDynamics shall not be liable for
incidental or consequential damages of any kind.
Dimensions (~ mm)
Product Guide