2
G2RL PCB Power Relay
G
2
R
L
■Characteristics
Note. Values in the above table are the initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
*3. 1,800 operations per hour.
■Engineering Data
Classification General-purpose Models High-capacity Models
Item Number of poles 1-pole 2-pole 1-pole
Contact resistance *1 100 m
Ω
max.
Operate (set) time 15 ms max.
Release (reset) time 5 ms max.
Max.
operating
frequency
Mechanical 18,000 operation/hr
Electrical 1,800 operation/hr
Insulation resistance *2 1,000 M
Ω
min.
Dielectric
strength
Between coil and
contacts 5,000 VAC, 50/60 Hz for 1min
Between contacts
of the same
polarity
1,000 VAC, 50/60 Hz for 1min
Between contacts
of different polarity
−
2,500 VAC, 50/60 Hz for 1min
−
Insulation
distance
Between coil and
contacts Clearance: 8 mm, Creepage: 8 mm
Impulse withstand voltage 10 kV (1.2 x 50
μ
s)
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock
resistance
Destruction 1,000 m/s
2
Malfunction Energized: 100 m/s
2
, De-energized: 100 m/s
2
Durability
Mechanical 20,000,000 operations (at 18,000 operations/hr)
Electrical *3
(resistive load)
G2RL-1(A): 50,000 operations at 250 VAC, 12 A
30,000 operations at 24 VDC, 12 A
G2RL-2(A): 30,000 operations at 250 VAC, 8 A
30,000 operations at 30 VDC, 8 A
G2RL-1(A)-E: 30,000 operations at 250 VAC, 16 A
30,000 operations at 24 VDC, 16 A
Ambient operating temperature -40°C to 85°C (with no icing or condensation)
Ambient operating humidity 5% to 85% (with no icing or condersation)
Weight Approx. 12 g
●Maximum Switching Capacity
G2RL-1A, G2RL-1 G2RL-1A-E, G2RL-1-E G2RL-2A, G2RL-2
●Ambient Temperature vs. Maximum
Coil Voltage
●
Ambient Temperature vs. Must
Operate and Must Release Voltages
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 10 20 30 50 100 500
1,000
AC resistive load
DC resistive
load
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.10 5 10 20 30 50 100 500
1,000
AC resistive load
DC resistive
load
Switching current (A)
Switching voltage (V)
50
10
5
1
0.5
0.1
0 5 10 20 30 50 100 500
1,000
AC resistive load
DC resistive
load
Maximum coil voltage (%)
Ambient temperature (°C)
250
200
150
100
50
0 10 20 30 40 50 60 70 80 90 100
180
130
85
100
90
80
70
60
50
40
30
20
10
Ambient temperature (°C)
0604020 80 100 120
Must operate/must release voltage
(percentage of rated voltage) (%)
Must operate voltage
Must release voltage
max.
min.
X
max.
min.
X
Sample:
G2RL-14-E 24 VDC
Number of relays: 5 pcs