2) Output side
Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. When the load current is less than the rated minimum load current, please refer to “Cautions for Use”.
3. Characteristics (Measurement condition: at 20°C 68°F, input ripple: 1% or less)
REFERENCE DATA
(1) AQ-J Solid State Relays
1. Load current vs. ambient temperature Use load current within range specified in the figure below
Part No.
Item
AQJ112VY
AQJ119VY
AQJ116VY
AQJ412VY
AQJ419VY
AQJ416VY
AQJ112VW
AQJ119VW
AQJ116VW
AQJ412VW
AQJ419VW
AQJ416VW
Output arrangement 1a 1a × 2
Max. load current*110A 20A 10A 15A
Load voltage 75 to 264V AC
Frequency 45Hz to 65Hz
Non-repetitive surge current*2100A 250A 100A 250A
“OFF-state” leakage current Max. 5mA
“ON-state” voltage drop Max. 1.6V
Min. load current*350mA
Item Characteristics Remarks
Operate time Max. 1/2 cycle of voltage sine wave + 1ms
Release time Max. 1/2 cycle of voltage sine wave + 1ms
Insulation resistance Min. 100MΩ between input, output and case at 500 V DC
Breakdown voltage 3,000 Vrms between input and output for 1min.
2,500 Vrms between input, output and case
Vibration resistance SSR stand-alone: 10 to 55Hz, double amplitude of 1.5mm
Slim heat sink combined type: 10 to 55Hz, double amplitude of 0.75mm X, Y, Z axes
Shock resistance SSR stand-alone: Min. 980m/s2
Slim heat sink combined type: Min. 197m/s2X, Y, Z axes
Ambient temperature –30 to +80°C –22 to +176°FNon-condensing at low temperatures
Storage temperature –30 to +100°C –22 to +212°F
Operational method Zero-cross (Turn ON and Turn OFF)
Tested condition:
1) If attached to a heat sink, use a heat
conductive compound of similar coating to
improve cooling
2) Without external heat sink
If the mounting surface is not metallic and a
heat sink is not used, expose the bottom
surface and plate surface to improve heat
dissipation.
3) The current value is per 1a.
(1) 10 A type (when using heat sink or iron
plate)
(2)-1. 15 A type (when using iron plate)
(A) slim heat sink AQP-HS-SJ20A
(B) slim heat sink AQP-HS-SJ10A
(C) standard heat sink AQP-HS-J10A
(D) DIN rail mounting plate AQP-DPJ
(E) standard heat sink AQP-HS-J25A 100806040200
2
4
6
8
12
10
0
When a single unit is mounted on an (A) slim heat sink
When a single unit is mounted
on an (B) slim heat sink
When two units are mounted
on an (A) slim heat sink
When a single unit is mounted
on an (C) standard heat sink
When two units are mounted
on an (B) slim heat sink
When using 100×100×t1.6 mm iron plate
When using as stand-alone
When using an (D) DIN rail mounting plate
Ambient temperature, °C
Load current, A
6
12
9
3
18
15
00-20 20 40 60 80
Ambient temperature, °C
Load current, A
When using 200 × 200 × t2 mm iron plate
When using
100 × 100 × t1.6 mm
iron plate
When using
150 × 150 × t1.6 mm
iron plate
(2)-2. 15 A type (when using a heat sink) (3)-1. 25 A type (when using iron plate) (3)-2. 25 A type (when using a heat sink)
100806040200
5
10
15
20
0
When a single unit
is mounted on an
(A) slim heat sink
When a single unit is mounted
on an (C) standard heat sink
When a single unit is mounted
on an (B) slim heat sink
When two units are mounted
on an (B) slim heat sink
When two units are mounted
on an (A) slim heat sink
When using as stand-alone
When using an (D) DIN rail mounting plate
Ambient temperature, °C
Load current, A
0-20 20 40 60 80
5
10
15
20
25
30
0
Ambient temperature, °C
Load current, A
When using 300 × 300 × t2 mm iron plate
When using 150 × 150 × t1.6 mm
iron plate
When using 100 × 100 × t1.6 mm
iron plate
When using 250 × 250 × t2 mm
iron plate When using
200 × 200 × t2 mm
iron plate
100806040200
5
10
15
20
30
25
0
When two units
are mounted on an
(B) slim heat sink
When a single
unit is mounted on an
(B) slim heat sink
When two units are
mounted on an (A)
slim heat sink
When a single unit is mounted
on an (C) standard heat sink
When a single unit is
mounted on an (A)
slim heat sink
When using as stand-alone
When using an (D) DIN rail mounting plate
When a single unit is
mounted on an (E)
standard heat sink
Ambient temperature, °C